COOLING SYSTEM SPECIFICATIONS - CARS
| Application | Specification |
| Coolant Replacement Interval |
| Except Metro, Firefly (Canadian) & Prizm | 60 Months Or 150,000 Miles |
| Metro & Firefly (Canadian) | 30 Months Or 30,000 Miles |
| Prizm | 24 Months Or 30,000 Miles |
| Coolant Capacity (1) |
| 1.0L | 3.9 Qts. (4.1L) |
| 1.3L |
| M/T | 4.9 Qts. (4.4L) |
| A/T | 5.0 Qts. (4.7L) |
| 1.8L |
| Prizm |
| A/T | 6.0 Qts. (5.7L) |
| M/T | 6.1 Qts. (5.8L) |
| 1.9L | 7.0 Qts. (6.6L) |
| 2.2L |
| "J" Body | 9.6 Qts. (9.1L) |
| "Z" Body | 7.4 Qts. (7.0L) |
| 2.4L |
| "J" Body | 9.9 Qts. (9.4L) |
| "N" Body | 11.3 Qts. (10.7L) |
| 3.0L |
| Except "Z" Body | 10.0 Qts. (9.5L) |
| "Z" Body | 7.8 Qts. (7.3L) |
| 3.1L |
| "N" Body | 13.1 Qts. (12.4L) |
| "W" Body | 11.0 Qts. (10.4L) |
| 3.4L | 13.6 Qts. (12.9L) |
| 3.5L | 10.0 Qts. (9.5L) |
| 3.8L Except "F", "H" & "W" Bodies | 13.0 Qts. (12.3L) |
| "F" Body |
| A/T | 12.3 Qts. (11.6L) |
| M/T | 12.5 Qts. (11.8L) |
| "H" Body | 10 Qts. (9.5L) |
| "W" Body | 10.1 Qts. (9.6L) |
| 4.0L | 13.0 Qts. (12.3L) |
| 4.6L Except "E" & "K" Body | 10.7 Qts. (10.0L) |
| "E" & "K" Bodies | 12.5 Qts. (11.8L) |
| 5.7L |
| "F" Body |
| A/T | 15.1 Qts. (14.3L) |
| M/T | 15.3 Qts. (14.5L) |
| "Y" Body |
| A/T | 12.3 Qts. (11.6L) |
| M/T | 12.6 Qts. (11.9L) |
| Pressure Cap |
| "F" Body | 18 psi |
| Metro & Firefly (Canadian) | 13 psi |
| Prizm | 13 psi |
| Saturn | 15 psi |
| All Others | (2) 15 psi |
| Thermostat |
| Metro & Firefly (Canadian) |
| Starts To Open | 190-197°F (88-92°C) |
| Fully Opens | 212-221°F (100-105°C) |
| Prizm |
| Starts To Open | 176-183°F (80-84°C) |
| Fully Opens | 203°F (95°C) |
| Saturn |
| Starts To Open | 182-190°F (83-88°C) |
| Fully Open | 212-222°F (100-106°C) |
| All Others |
| Starts To Open | 189°F (87°C) |
| Fully Opens | 207°F (97°C) |
| (1) Specification is approximate and includes heater capacity. (2) Or specification stamped on cap. |
| (1) | Specification is approximate and includes heater capacity. |
| (2) | Or specification stamped on cap. |
COOLING SYSTEM SPECIFICATIONS - CARS
COOLING SYSTEM SPECIFICATIONS - TRUCKS
| Application | Specification |
| Coolant Replacement Interval |
| Except Tracker | 60 Months Or 150,000 Miles |
| Tracker | 30 Months Or 30,000 Miles |
| Pressure Cap |
| Except Tracker | 15 psi |
| Tracker | 13 psi |
| Thermostat Opens |
| Except Tracker |
| Starts | 188°F (87°C) |
| Fully Open | 206°F (97°C) |
| Tracker |
| Starts | 179°F (82°C) |
| Fully Open | 203°F (95°C) |
| Coolant Capacity (1) |
| 1.6L | 6.9 Qts. (6.5L) |
| 2.0L | 5.8 Qts. (5.5L) |
| 2.2L |
| A/T | 9.7 Qts. (9.2L) |
| M/T | 9.9 Qts. (9.4L) |
| 2.5L | 8.5 Qts. (8.0L) |
| 3.4L |
| Standard |
| With Rear Heater | 11.9 Qts. (11.3L) |
| Without Rear Heater | 9.6 Qts. (9.0L) |
| Heavy Duty |
| With Rear Heater | 13.2 Qts. (12.5L) |
| Without Rear Heater | 10.5 Qts. (9.9L) |
| 4.3L |
| "C" & "K" Series |
| A/T | 12.7 Qts. (12.0L) |
| M/T | 13.0 Qts. (12.3L) |
| "G" Series |
| With Rear Heater | 14.0 Qts. (13.2L) |
| Without Rear Heater | 11.0 Qts. (10.5L) |
| "L" & "M" Series |
| With Rear Heater | 16.5 Qts. (15.5L) |
| Without Rear Heater | 14.3 Qts. (12.8L) |
| "S" & "T" Series |
| A/T | 11.7 Qts. (11.1L) |
| M/T | 11.9 Qts. (11.3L) |
| 4.8L |
| A/T | 13.4 Qts. (12.7L) |
| M/T | 13.7 Qts. (13.0L) |
| 5.0L |
| With A/C | 20.0 Qts. (18.9L) |
| Without A/C | 17.0 Qts. (16.0L) |
| 5.3L |
| With A/C | 14.9 Qts. (14.1L) |
| With Rear A/C | 15.8 Qts. (15.0L) |
| Without A/C | 13.4 Qts. (12.7L) |
| 5.7L |
| Standard |
| With A/C | 20.0 Qts. (19.0L) |
| Without A/C | 17.5 Qts. (16.6L) |
| Heavy Duty |
| With A/C | 27.0 Qts. (25.5L) |
| Without A/C | 26.4 Qts. (25.0L) |
| 6.0L |
| A/T |
| With Oil Cooler | 14.4 Qts. (13.6L) |
| Without Oil Cooler | 14.8 Qts. (14.0L) |
| M/T |
| With Oil Cooler | 14.8 Qts. (14.0L) |
| Without Oil Cooler | 15.2 Qts. (14.4L) |
| 6.5L | 27.5 Qts. (26.0L) |
| 6.6L |
| A/T | 20.3 Qts (19.2L) |
| M/T | 20.7 Qts. (19.6L) |
| 7.4L |
| Standard |
| With A/C | 27.5 Qts. (26.0L) |
| Without A/C | 25.0 Qts. (23.7L) |
| Heavy Duty |
| With A/C | 28.5 Qts. (27.0L) |
| Without A/C | 26.4 Qts. (25.0L) |
| 8.1L |
| A/T | 20.7 Qts. (19.6L) |
| M/T | 21.1 Qts. (20.0L) |
| (1) Specification is approximate and includes heater capacity. |
| (1) | Specification is approximate and includes heater capacity. |
COOLING SYSTEM SPECIFICATIONS - TRUCKS