Contents Wiring diagrams Section: Body Electrical All sections

Power Outlets: Removal & Installation Chevrolet Silverado 1500

120 Volt Receptacle Replacement

CAUTIONTo reduce the risk of severe shock and burns, disable the 42 volt (42V) system anytime you perform service work on or around the energy storage box (ESB). The 42V system will still be active after you have disabled the ESB.
CAUTIONTo reduce the risk of severe shock and burns, always disconnect the 42 volt (42V) energy storage box (ESB) before doing any work to the ESB system. To disconnect the ESB, turn the engine off and turn OFF the service disconnect switch, which is located on the passenger side of the ESB.

Removal Procedure

  1. Disconnect the energy storage box (ESB). Refer to «Energy Storage Box (ESB) Service Disconnect/Connect (5.3L Engine w/RPO HP2)»(ref-238198-S14706325592006072400000) .
  2. Remove the receptacle outlet screws (2).
  3. Remove the receptacle outlet (3) from the receptacle box (1).
  4. Disconnect the receptacle electrical connections.

Installation Procedure

  1. Connect the receptacle electrical connections.
  2. Install the receptacle outlet (3) to the receptacle box (1).
  3. Install the receptacle outlet screws (2). Tighten: Tighten the screws to 2 N.m (18 lb in).
  4. Connect the ESB. Refer to «Energy Storage Box (ESB) Service Disconnect/Connect (5.3L Engine w/RPO HP2)»(ref-238198-S14706325592006072400000) .