Car Cooling System Specifications

ApplicationSpecification
Coolant Replacement Interval
Except Metro, Firefly (Canadian) & Prizm60 Months Or 150,000 Miles
Metro & Firefly (Canadian)30 Months Or 30,000 Miles
Prizm24 Months Or 30,000 Miles
Coolant Capacity (1)
1.0L4.1 Qts. (3.9L)
1.3L
M/T4.9 Qts. (4.6L)
A/T5.0 Qts. (4.7L)
1.8L
Prizm
A/T6.0 Qts. (5.7L)
M/T6.1 Qts. (5.8L)
1.9L7.0 Qts. (6.6L)
2.2
"J" Body9.6 Qts. (9.1L)
2.4L
"J" Body9.9 Qts. (9.4L)
"N" Body11.3 Qts. (10.7L)
3.0L10.0 Qts. (9.5L)
3.1L
"L" & "N" Bodies13.6 Qts. (12.9L)
"W" Body11.7 Qts. (11.0L)
3.4L13.6 Qts. (12.9L)
3.5L9.8 Qts. (9.3L)
3.8L
Except "F" & "W" Bodies13.0 Qts. (12.3L)
"F" Body
A/T12.3 Qts. (11.6L)
M/T12.5 Qts. (11.8L)
"W" Body10.7 Qts. (10.1L)
4.0L13.0 Qts. (12.3L)
4.6L Except Seville10.7 Qts. (10.1L)
4.6L Seville12.5 Qts. (11.8L)
5.7L
"F" Body
A/T15.1 Qts. (14.3L)
M/T15.3 Qts. (14.5L)
"Y" Body
A/T12.3 Qts. (11.6L)
M/T12.6 Qts. (11.9L)
Pressure Cap
"F" Body18 psi
Metro & Firefly (Canadian)13 psi
Prizm13 psi
Saturn15 psi
All Others(2) 15 psi
Thermostat
Prizm
Starts To Open176-183°F (80-84°C)
Fully Opens203°F (95°C)
Metro & Firefly (Canadian)
Starts To Open190-197°F (88-92°C)
Fully Opens212-221°F (100-105°C)
Saturn
Starts To Open182-190°F (83-88°C)
Fully Open212-222°F (100-106°C)
All Others
Starts To Open189°F (87°C)
Fully Opens207°F (97°C)
(1) Specification is approximate and includes heater capacity. (2) Or specification stamped on cap.
(1)Specification is approximate and includes heater capacity.
(2)Or specification stamped on cap.

COOLING SYSTEM SPECIFICATIONS - CARS

Truck Cooling System Specifications

ApplicationSpecification
Coolant Replacement Interval
Except Tracker60 Months Or 150,000 Miles
Tracker30 Months Or 30,000 Miles
Pressure Cap
Except Tracker15 psi
Tracker13 psi
Thermostat Opens
Except Tracker
Starts188°F (87°C)
Fully Open206°F (97°C)
Tracker
Starts179°F (82°C)
Fully Open203°F (95°C)
Coolant Capacity (1)
1.6L
Tracker6.9 Qts. (6.5L)
2.0L
Tracker5.8 Qts. (5.5L)
2.2L11.6 Qts. (11.0L)
3.4L
With Rear Heater12.4 Qts. (11.75L)
Without Rear Heater11.8 Qts. (11.25L)
4.3L
"C" & "K" Series
A/T12.7 Qts. (12.0L)
M/T13.0 Qts. (12.3L)
"G" & "P" Series
With Rear Heater14.0 Qts. (13.2L)
Without Rear Heater11.0 Qts. (10.5L)
"L" & "M" Series
With Rear Heater16.5 Qts. (15.5L)
Without Rear Heater13.5 Qts. (12.8L)
"P" Series13.0 Qts. (12.3L)
"S" & "T" Series
A/T11.7 Qts. (11.1L)
M/T11.9 Qts. (11.3L)
4.8L
A/T13.4 Qts. (12.7L)
M/T13.7 Qts. (13.0L)
5.0L
With A/C18.0 Qts. (17.0L)
Without A/C17.5 Qts. (16.6L)
5.3L
With A/C14.9 Qts. (14.1L)
Without A/C13.4 Qts. (12.7L)
5.7L
Standard
With A/C20.0 Qts. (19.0L)
Without A/C17.5 Qts. (16.6L)
Heavy Duty
With A/C27.0 Qts. (25.5L)
Without A/C26.4 Qts. (25.0L)
6.0L
A/T
With Oil Cooler14.4 Qts. (13.6L)
Without Oil Cooler14.8 Qts. (14.0L)
M/T
With Oil Cooler14.8 Qts. (14.0L)
Without Oil Cooler15.2 Qts. (14.4L)
6.5L25.0 Qts. (23.7L)
7.4L
Standard
With A/C27.5 Qts. (26.0L)
Without A/C25.0 Qts. (23.7L)
Heavy Duty
With A/C28.5 Qts. (27.0L)
Without A/C26.4 Qts. (25.0L)
(1) Specification is approximate and includes heater capacity.
(1)Specification is approximate and includes heater capacity.

COOLING SYSTEM SPECIFICATIONS - TRUCKS