Home/Chevrolet/Captiva/Chevrolet Captiva I facelift (2011-2013)/Repair manual/Automatic HVAC System/Heating, Ventilation, and Air Conditioning: Specifications
Contents Wiring diagrams Section: Automatic HVAC System All sections

Heating, Ventilation, and Air Conditioning: Specifications Chevrolet Captiva I facelift

Fastener Tightening Specifications

ApplicationSpecification
MetricEnglish
Blower Motor Resistor Screws6 N.m53 lb in
Blower Motor Screws6 N.m53 lb in
Clutch Plate and Hub Assembly Retaining Nut13.5 N.m10 lb ft
Compressor Hose Bracket-to-Vehicle Bolt9 N.m80 lb in
Compressor Hose-to-Compressor Nut22 N.m16 lb ft
Compressor Hose-to-Condenser Bolt22 N.m16 lb ft
Discharge Hose Connecting Block-to-Compressor Retaining Nut22 N.m16 lb ft
Discharge Hose Connecting Block-to-Condenser Retaining Nut22 N.m16 lb ft
ECM Bracket Mounting Nuts15 N.m11 lb ft
Evaporator Outlet Hose Clip-to-Vehicle Nut16 N.m12 lb ft
Evaporator Outlet Hose-to-Compressor Hose Nut22 N.m16 lb ft
Evaporator Outlet Hose-to-Thermal Expansion Valve Nut22 N.m16 lb ft
Front Compressor-to-Bracket Mounting Bolts23 N.m17 lb ft
HVAC Module Screws8 N.m71 lb in
HVAC Module-to-Cowl Nuts8 N.m71 lb in
I/P Center Air Outlet Fasteners2 N.m18 lb ft
Liquid Line Clip-to-Vehicle Nuts16 N.m12 lb ft
Liquid Line-to-Condenser Bolt22 N.m16 lb ft
Liquid Line-to-Thermal Expansion Valve Nut22 N.m16 lb ft
Pressure Relief Valve16 N.m12 lb ft
Pressure Transducer7 N.m62 lb in
Rear Compressor Bracket Mounting Bolts23 N.m17 lb ft
Rear Compressor-to-Bracket Mounting Bolts20 N.m15 lb ft
Thermal Expansion Valve Bolts10 N.m89 lb in
Upper Condenser Mount Bolts4 N.m35 lb in

Fastener Tightening Specifications

Refrigerant System Specifications

ApplicationSpecification
MetricEnglish
PAG Oil P/N 22695048
Abrupt Refrigerant Loss74 ml 12.5 oz 1
Compressor Replacement
The Denso service compressor is precharged with the specified amount of PAG oil.74 ml 12.5 oz 1
Condenser Replacement30 ml 21 oz 2
Evaporator Replacement30 ml 21 oz 2
Thermal Expansion Valve Replacement20 ml 20.75 oz 2
Total System PAG Oil Capacity - LF1120 ml4.00 oz
Total System PAG Oil Capacity - LAF (10SE18)160 ml5.30 oz
R-134a
Refrigerant Charge0.62 kg1.37 lb
1 Abrupt refrigerant loss due to a large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component. 2 If more than the specified amount of PAG oil was drained from a component, add the equal amount of oil drained.

Refrigerant System Capacities