Contents Wiring diagrams Section: Removal & Installation All sections

Removal (Cpi) Chevrolet Astro I

Disconnect IAC valve harness connector. Remove IAC valve retaining screws and remove IAC valve from upper intake manifold assembly.

Installation

  1. Inspect "O" ring for damage. Replace if necessary. If reusing IAC valve, DO NOT push or pull on pintle. Threads on worm gear will be damaged.
  2. If replacing IAC valve, measure distance between tip of new IAC valve pintle and mounting flange. Distance should not exceed 1 1/8" (28 mm). If distance is greater than specified, use finger pressure to slowly retract pintle. Lubricate "O" ring with clean engine oil.
  3. Apply thread locking compound (Loctite 262) to IAC valve retaining screw threads. Install IAC valve to throttle body. Tighten IAC valve retaining screws to 27 INCH lbs. (3 N.m). Connect IAC valve harness connector.
  4. To reset IAC valve pintle position, turn ignition on for 5 seconds. Turn ignition off for 10 seconds. Start engine and check for proper idle operation. Repeat IAC valve resetting procedure if proper idle operation cannot be obtained.