Home/Cadillac/SRX/Cadillac SRX II facelift (2012-2016)/Repair manual/Automatic HVAC System/Heating, Ventilation, and Air Conditioning: Specifications
Contents Wiring diagrams Section: Automatic HVAC System All sections

Heating, Ventilation, and Air Conditioning: Specifications Cadillac SRX II facelift

Fastener Tightening Specifications

ApplicationSpecification
MetricEnglish
A/C Compressor Mounting Bolt5843 lb ft
A/C Compressor Mounting Nut2216 lb ft
A/C Line to Frame Rail Bracket Nut980 lb in
Air Conditioning Condenser and Evaporator Hose Bolt at Compressor2216 lb ft
Air Conditioning Condenser and Evaporator Hose Nuts2216 lb ft
Air Conditioning Condenser and Air Conditioning Evaporator Tube Nuts2216 lb ft
Air Conditioning Condenser and Air Conditioning Evaporator Tube Nut at Thermal Expansion Valve1511 lb ft
Air Distribution Duct Screws1.513 lb in
Air Inlet Housing Fasteners2.523 lb in
Blower Motor Mounting Screws1.715 lb in
Condenser Mounting Bolts980 lb in
Heater and A/C Evaporator and Blower Module Fastener1.513 lb in
Heater Core Inlet/Outlet Tube Bracket Bolt/Retaining Screw2.522 lb in
HVAC Module to Cowl Bolt653 lb in
Instrument Panel Outer Air Outlet Fastener2.522 lb in
Receiver Dehydrator Bolt and Bracket Bolt653 lb in
Refrigerant Pressure Sensor544 lb in
TXV Bolts653 lb in
TXV Stud653 lb in
Valve Core653 lb in
Auxiliary Blower Motor Fastener2.522 lb in

Fastener Tightening Specifications

Refrigerant System Specifications

ApplicationSpecification
MetricEnglish
Abrupt Refrigerant Loss60 ml 12.0 oz 1
PAG Oil GM P/N 12378526 for United States PAG Oil GM P/N 88900060 for Canada
Compressor Replacement
NOTE: Compressor failure can occur if the oil removed during refrigerant recovery is not replaced. The service compressor is precharged with one of the following specified amounts of PAG oil. Refer to the instruction sheet included with the service compressor.74 ml 22.5oz 2
41 ml 21.4 oz 2
Condenser Replacement30 ml 21.0 oz 2
Evaporator Replacement90 ml 23.0 oz 2
Any Line Set (Hose/Tube or Tube Assembly) Replacement30 ml 21.0 oz 2
Total System PAG Oil Capacity110.0 ml3.7 oz
R-134a
Refrigerant Charge0.73 kg1.61 lb
1 Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component. 2 If more than the specified amount of PAG oil was drained from a component, add the amount drained.
NOTE
Compressor failure can occur if the oil removed during refrigerant recovery is not replaced.

Refrigerant System Capacities