Filling Procedure
Tools Required
J 23688 Coolant and Battery Fluid Tester. See Special Tools and Equipment .
Note. Refer to FASTENER NOTICE in Cautions and Notices.
- Close the radiator drain cock. Tighten Tighten the radiator drain cock to 2 N.m (18 lb in).
- If the engine block drain plug was removed, perform the following: 2.1. Apply pipe sealer to the drain plug. 2.2. Install the drain plug. Tighten Tighten the drain plug to 22 N.m (16 lb ft).
- Lower the vehicle.
- Open the cooling system bleeder screws. IMPORTANT: Use a 50/50 mixture of DEX-COOL antifreeze and deionized water.
- Slowly fill the cooling system with a 50/50 coolant mixture.
- Close the cooling system bleeder screws.
- Install the coolant pressure cap.
- Start the engine.
- Run the engine at 2,000 - 2,500 RPM until the engine reaches normal operating temperature.
- Allow the engine to idle for 3 minutes.
- Shut the engine off.
- Allow the engine to cool.
- Top off the coolant as necessary.
- Inspect the concentration of the engine coolant. Using the J 23688 .
- Rinse away any excess coolant from the engine and the engine compartment.
- Inspect the cooling system for leaks.