Ordering Replacement Coding Plug
The coding plugs are received pre-coded and installing them automatically codes the cluster.
The first digits of the 5-digit code is changed on coding plugs when they are replaced.
| E32 | E34 | |
|---|---|---|
| ORIGINAL NUMBER | 1 1101 | 2 0101 |
| REPLACEMENT NUMBER | 5 1101 | 4 0101 |
ORDERING REPLACEMENT CODING PLUG
Note. It is not possible to input the mileage reading, the service interval status and the chassis number into the replacement coding plug.
When is EPROM Replacement and/or Programming Necessary?
The program and or data of an engine or transmission control module only needs to be updated or replaced if
- The control module is replaced with a non programmed/basic module.
- A Service Action, Recall or customer concerns have resulted in the release of a new/updated program or revised operational data.
The programming procedure of the diagnostic equipment will identify if
- a DME EPROM needs to be replaced or can be updated
- a control module (DME or Transmission) can still be programmed or needs to be replaced if the reprogramming limit of 13 times has been reached
Installation
The Installation tap is selected when updates need to be installed either by a way of a new CIP DVD or checking for new online updates (Automatically or Manually). The updates that can be installed pertain to the Progman application as well as updated vehicle data files for utilization by CIP.
The table provides an overview of the software program and version currently installed.
The selection/activation of Automatic online updates via the BMW server is selected from this screen.
"DVD update" can be selected whenever a new CIP DVD needs to be installed.
"Online update" allows a manual check for online updates to be initiated.
Scheme 19
Note. It is recommended that the Automatic Online Update feature be activated to insure that needed Program and Coding updates are received in a timely manner. When new updates are made available they are downloaded and installed after the normal operating times of the workshop as specified under "Operating Times".
"Display status" provides information pertaining to the installation of the latest update.
Information pertaining to an erroneous installation of an update is displayed in the messages section.
Note. If frequent error messages are displayed contact your service provider for assistance and have available a copy of the error messages that have been received.