BMW ME9.2.3 (DTC P1327-U1202)
ME9.2.3 ECM applies to N62 engine.
BMW Fault Code (hex)
0x2E69
BMW Fault Code (dez)
11881
BMW Fault Code Description VS-Text
Knock-sensor signal 2
Component
Knock Sensor
Subcomponent
Sensor 2
Monitoring criteria
RPM > 2000 rpm. Load factor > 25
Fault debouncing
< 3 sec.
Terminal conditions
Engine running
Voltage conditions
9 - 15 V
Temperature conditions
T mot > 40°C
Time conditions
none
System test
none
Signal information
Analog 0.1 - 1 V according to n
Calculated value Y/N
N
Possible Fault Causes
Electrical fault, shorted signal, short to ground, open circuit; - sensor not installed correctly, loose bolts - Knock sensor outside approved tolerance range - Crankshaft sensor fault can produce diagnosis fault
Repair procedures (plant/service)
Check plugs and wires, inspect sensor mounting (torque), otherwise replace sensor
MIL illumination/CC message/emergency program
MIL on
Remarks
No Info
0x2E69
11881
Knock-sensor signal 2
Knock Sensor
Sensor 2
RPM > 1600 rpm Load factor > 25
< 3 sec.
Engine running
9 - 15 V
T mot > 40 °C
none
none
Analog 7.5 - 40 V according to n
N
Excess engine noise from mechanical defect - Knock sensor outside approved tolerance range - Poor fuel below specification < RON 91 - KWG fault can produce diagnosis fault
Check engine for mechanical defects, otherwise replace sensor
MIL on
No Info
0x2E6A
11882
Knock-sensor signal 3
Knock Sensor
Sensor 3
RPM > 2000 rpm Load factor > 25
< 3 sec.
Engine running
9 - 15 V
T mot > 40°C
none
none
Analog 0.1 - 1 V according to n
N
Electrical fault, shorted signal, short to ground, open circuit; - sensor not installed correctly, loose bolts - Knock sensor outside approved tolerance range - Crankshaft sensor fault can produce diagnosis fault
Check plugs and wires, inspect sensor mounting (torque), otherwise replace sensor
MIL on
No Info
0x2E6A
11882
Knock-sensor signal 3
Knock Sensor
Sensor 3
RPM > 1600 rpm Load factor > 25
< 3 sec.
Engine running
9 - 15 V
T mot > 40 °C
none
none
Analog 7.5 - 40 V according to n
N
Excess engine noise from mechanical defect - Knock sensor outside approved tolerance range - Poor fuel below specification < RON 91 - KWG fault can produce diagnosis fault
Check engine for mechanical defects, otherwise replace sensor
MIL on
No Info
0x2E69
11881
Knock-sensor signal 2
Knock Sensor
Sensor 2
RPM > 1520 rpm Load factor > 25
< 3 sec.
Engine running
9 - 15 V
T mot > 40 °C
none
none
none
N
Interference with data communications in KR module
Replace DME
MIL on
No Info
0x2B66
11110
Camshaft sensor, master
No Info
No Info
Fault present in all phases
5 camshaft revolutions
Terminal 15=TRUE
none
none
8 camshaft revolutions after engine start
None
Target: Signals E_P_NGWA1, E_P_NGWA2, E_P_NGWE1, E_P_NGWE2 electrically inverse to mechanical reluctor
N
All camshaft sensors fail and error codes have been logged: Defect in power supply to camshaft sensors
Check voltage supply (T87) + and ground connection for sensor, signal wire to DME; check sensor installation; if OK, replace sensor
Engine Fault! Reduced Power
No remaining NWG is available to assume the role of master. At least one NWG is needed to calculate the engine's current position. If the last remaining NWG fails while the engine is running, it remains possible to calculate the engine's position using the KWG. Once the engine is off, it is not possible to restart it.
0x2E72
11890
Control module, internal fault: knock sensor module
ECM Self-Test
Knock Control
RPM > 1520 rpm Load factor > 25
< 10 sec.
Engine running
9 - 15 V
T mot > 40°C
none
none
none
N
Knock chip defective
Replace DME
MIL on
No Info
0x2E72
11890
Control module, internal fault: knock sensor module
ECM Self-Test
Knock Control
RPM > 1520 rpm Load factor > 25
< 10 sec.
Engine running
9 - 15 V
T mot > 40°C
none
none
IkrmetI > 4.5 V
N
Knock chip defective
Replace DME
MIL on
No Info
0x2E6A
11882
Knock-sensor signal 3
Knock Sensor
Sensor 3
RPM > 1520 rpm Load factor > 25
< 3 sec.
Engine running
9 - 15 V
T mot > 40 °C
none
none
none
N
Interference with data communications in KR module
Replace DME
MIL on
No Info
0x2E72
11890
Control module, internal fault: knock sensor module
ECM Self-Test
Knock Control
RPM > 1520 rpm Load factor > 25
< 10 sec.
Engine running
9 - 15 V
T mot > 40°C
none
none
Igot < 0.2 V/msec
N
Knock chip defective
Replace DME
MIL on
No Info
0x2A17
10775
DMTL, system fault
EVAP System
Pump Current
Additional release conditions: < 2400 m. above sea level; idle time > 30s; vehicle speed above 40 km/h > 10 min.; engine start temp. 6.6°C < as ambient temperature
Minimum travel distance between refueling and severe leak suspicion = 200 m. Fuel level validation lag for leak diagnosis distance debounce = 20 sec.
Terminal 15 off/on
10.95 < U (V) < 14.5
> 4°C < 35°C
< 550 sec. once per DC
P1434
analog
N
Internal component fault
Replace DM-TL
MIL ON
Canister loag 3
0x2A17
10775
DMTL, system fault
EVAP System
Pump Current
Additional release conditions: < 2400 m. above sea level; idle time > 30 s; vehicle speed above 40 km/h > 10 min.; engine start temp. 6.6°C < as ambient temperature
Minimum travel distance between refueling and severe leak suspicion = 200 m. Fuel level validation lag for leak diagnosis distance debounce = 20 sec.
Terminal 15 off/on
10.95 < U (V) < 14.5
> 4°C < 35°C
15 sec. once per driving cycle
P1447
analog
N
Internal component fault
Replace DM-TL
MIL ON
15% < FTL <85% ECM on
0x2A17
10775
DMTL, system fault
EVAP System
Pump Current
Additional release conditions: < 2400 m. above sea level; idle time > 30 s; vehicle speed above 40 km/h > 10 min.; engine start temp. 6.6°C < as ambient temperature
Minimum travel distance between refueling and severe leak suspicion = 200 m. Fuel level validation lag for leak diagnosis distance debounce = 20 sec.
Terminal 15 off/on
10.95 < U (V) < 14.5
> 4°C < 35°C
10 sec. monitoring time once per DC
Can be triggered with DMTL system test; P Code 1448
Pump current < 15 mA
N
Internal component fault
Replace DM-TL
MIL ON
Engine start temp. > 2°C
0x2A17
10775
DMTL, system fault
EVAP System
Pump Current
Additional release conditions: < 2400 m. above sea level; idle time > 30 s; vehicle speed above 40 km/h > 10 min.; engine start temp. 6.6°C < as ambient temperature
Minimum travel distance between refueling and severe leak suspicion = 200 m. Fuel level validation lag for leak diagnosis distance debounce = 20 sec.
Terminal 15 off/on
10.95 < U (V) < 14.5
> 2°C < 37°C
10 sec. monitoring time once per DC
Can be triggered with DMTL system test; P Code 1449
> 40 mA
N
Internal component fault
Replace DM-TL
MIL ON
Engine start temp. > 2°C
0x2F11
12049
Radiator blind, top
No Info
No Info
Active cooling flap control must be initialized.
up to 20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
In the SGBD: 'start_systemcheck_glf'
PWM of 5-90 %
N
- Wire from the DME to the active cooling flap control is shorted to ground.
- No voltage supply to the active cooling flap control. PVE: Ground wire from DME to active cooling flap control.
- Check whether self-diagnosis fault for active cooling flap control or passive cooling flap control is entered in FS. (If yes, start by repairing this.)
- Check wiring from the DME to the active cooling flap control
- Check voltage supply to the active cooling flap control
no external display
New fault location ME9.2.3. No hazard is present provided that the voltage supply to the active cooling flap control is OK. (safety circuit in the active cooling flap control is active: both flaps remain open.)
0x2F11
12049
Radiator blind, top
No Info
No Info
Active cooling flap control must be initialized.
up to 20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
In the SGBD: 'start_systemcheck_glf'
PWM of 5-90 %
N
- Wire from DME to active cooling flap control is shorted to battery voltage. PVE: Connect wire from DME to active cooling flap control to battery voltage.
- Check wire from the DME to the active cooling flap control
no external display
New fault location ME9.2.3. No hazard is present provided that the voltage supply to the active cooling flap control is OK. (safety circuit in the active cooling flap control is active: both flaps remain open.)
0x2F10
12048
Radiator blind, bottom
No Info
No Info
- Passive cooling flap control must be initialized. Operation of lower flap: 3 x open and 3 x closed. Or conduct the system test
up to 20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
In the SGBD: 'start_systemcheck_glf'
PWM of 5-90%
N
- Defect in wire from active cooling flap control to passive cooling flap control (all 3 fault classes)
- Defect in wire from passive cooling flap control to ground (open wire or short to battery voltage)
- Defective retention solenoid (internal short
- Check wire from active cooling flap control PIN 4 to passive cooling flap control (+ terminal)
- Check ground connection on the passive cooling flap control
- Check retainer solenoid (internal short or burned through)
no external display
New fault location ME9.2.3 There is no danger with the passive cooling flap control provided that it does not stop operating in its closed position.
0x2E8B
11915
Intelligent battery sensor, signal
No Info
No Info
IBS: Interference with extended communications on BSD bus
Time
none
none
none
none
N
Monitored data from IBS to DME as serial bus signals through BSD = Synchronous bit data interface. Test possible with 'Uni_Bsd 2001 ' tester from Eyssler.
N
- Brief bus fault
- Other defective BSD component interferes with BSD bus.
- Sporadic short to battery voltage/ground 4. Intermittent contact on BSD wire 5. Defective battery sensor.
- Check BSD wire for sporadic shorts to battery voltage and ground
- Check for intermittent contacts
- Disconnect other BSD components one after the other and replace as indicated
- If fault persists after deletion of stored fault codes from log, replace battery sensor
- If fault code is logged repeatedly, replace battery sensor
No warning lamp or CC status report
No Info
0x2E8B
11915
Intelligent battery sensor, signal
No Info
No Info
IBS: Interference in data communications on BSD bus
Time
none
none
none
none
N
Serial bus signal
N
- BSD wire open
- Other defective BSD component interferes with traffic on BSD bus.
- Intermittent short to battery voltage or ground
- Defective battery sensor.
- Check BSD wire for shorts to battery voltage and ground
- Check for open wires
- Disconnect other BSD components one after the other and replace as indicated
- If fault persists after deletion of stored fault codes from log, replace battery sensor
- If fault code is logged repeatedly, replace battery sensor
No warning lamp or CC status report
No Info
0x2EB8
11960
No BSD message from intelligent battery sensor
No Info
No Info
E65: Application data content defined E6x: Terminal 15
4 sec.
Terminal 15
none
none
10 component requests repeated 10 times before fault is logged
none
if the components fail to respond to request
Yes
BSD component failure. Malfunctions/interference in BSD bus system
Check IBS plug Check BSD wire. Replace defective components as indicated.
none
Revisions to application still pending for E70
0x2EBA
11962
not translated
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
none
none
Fault not active in ME922T$UU/ME92 3
0x2EBB
11963
not translated
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
none
none
Fault not active in ME922T$UU/ME92 3
0x2E8B
11915
Intelligent battery sensor, signal
No Info
No Info
IBS: Implausible SW version
Time
none
none
none
none
N
Serial bus signal
N
Installed sensor incompatible or too old
Install sensor with current part number
No warning lamp or CC status report
No Info
0x2E8C
11916
Intelligent battery sensor, signal transmission
No Info
No Info
Implausible battery temperature measurement
Event-oriented
none
none
none
none
N
Serial bus signal
N
Self-diagnosis has detected potential problem in its temperature measurement
- If fault persists after deletion of stored fault codes from log, replace battery sensor
- If fault code is entered repeatedly, replace battery sensor
No warning lamp or CC status report
No Info
0x2E8C
11916
Intelligent battery sensor, signal transmission
No Info
No Info
Implausible battery voltage measurement
Event-oriented
none
none
none
none
N
Serial bus signal
N
Self-diagnosis has detected possible problem with its voltage measurement
- If fault persists after deletion of stored fault codes from log, replace battery sensor
- If fault code is entered repeatedly, replace battery sensor
No warning lamp or CC status report
No Info
0x2E8C
11916
Intelligent battery sensor, signal transmission
No Info
No Info
Implausible battery current measurement
Event-oriented
none
none
none
none
N
Serial bus signal
N
Self-diagnosis has detected possible problem with its battery current measurement
- Check electrical system/alternator for overvoltage
- If fault remains after deleting stored fault codes from log, replace battery sensor
- If fault is logged repeatedly, replace battery sensor
No warning lamp or CC status report
No Info
0x2B70
11120
Variable intake system, activation
DISA (Differentiated Intake Manifold)
Electrical
Short-circuit current on H bridge >= 8 A
n> 40 rpm, tateist_w <= 10%
Terminal 15=TRUE
9 V < U > 16 V
none
none
No info.
PWM control-activation signal
Yes
Wire fallen off, jumper in circuit, overheating, excess current, driver circuit defect (SPI fault)
Check wiring harness, otherwise replace DME
none
none
0x2B70
11120
Variable intake system, activation
DISA (Differentiated Intake Manifold)
Signal
Short-circuit current on H bridge >= 8 A
n> 40 rpm, tateist_w <= 10 %
Terminal 15=TRUE
9 V < U > 16 V
none
none
No info.
PWM control-activation signal
Yes
Short to ground
Check wiring harness, otherwise replace DME
none
none
0x2B70
11120
Variable intake system, activation
DISA (Differentiated Intake Manifold)
Signal
Short-circuit current on H bridge >= 8 A
n> 40 rpm, tateist_w <= 10 %
Terminal 15=TRUE
9 V < U > 16 V
none
none
No info.
PWM control-activation signal
Yes
Short to positive
Check wiring harness, otherwise replace DME
none
none
0x2F80
12160
System time, plausibility
Engine Off Timer, External
Electrical
Implausible instrument cluster and/or power module signal
Time
Terminal 30
DME operating range 6 V - 16 V
DME operating range - 40 V -128°C
Continuous as soon as CAN bus is on
none
+-80s difference between timers
N
The system time (time pulse) is implausible relative to DME's internal counter
E65: Check power module if no other CAN faults are detected E60: Check instrument cluster if no other CAN faults are detected.
MIL
No CC message Revisions to application still pending for E70
0x29DD
10717
Poor road surface detection
No signal
10 sec.
Terminal 15, engine on
none
none
Continuous
none
none
Yes
Possible failure of wheelspeed sensors on drive axle
Check DSC-SG
none
Plausibility check in DSC-SG, fault entry in DSC-SG? Revisions to application still pending for E70
0x29DD
10717
Poor road surface detection
v>4000 km/h
10 sec.
Terminal 15, engine on
none
none
Continuous
none
none
Yes
One transmitted wheelspeed is too high
Check DSC-SG
none
Plausibility check in DSC-SG, fault entry in DSC-SG? Revisions to application still pending for E70
0x2E8D
11917
Intelligent battery sensor, function
No Info
No Info
Terminal 15-wakeup wire shorted to ground
Event-oriented
If terminal 15/wakup is being controlled by IBS and charge state is critical
none
none
none
N
Serial bus signal
N
- Terminal 15/wake-up wire shorted to ground
- Defective driver circuit in battery sensor
- With battery sensor disconnected, check Terminal 15/wake-up wire for shorts to ground
- Check for non-approved connection of supplementary electr. equipment to Terminal 15/wake-up wire
- If fault code is stored, replace battery sensor
No warning lamp or CC status report
No Info
0x2E8D
11917
Intelligent battery sensor, function
No Info
No Info
Terminal 15-Wakeup wire signal level implausible
Event-oriented
at each Terminal 15 switch, meaning rising or falling
none
none
none
N
Serial bus signal
N
- Terminal 15/wake-up wire open
- Intermittent open in Terminal 15/wake-up wire
- Terminal 15/wake-up wire shorted to ground or battery voltage
- Defective driver circuit in battery sensor
- Check Terminal 15/wakeup wire for opens and intermittent contacts
- With battery sensor removed and Terminal 15 off, check Terminal 15/wakeup wire for short to battery voltage -> Repair wire and/or check Terminal 15, control module wakeup
- With battery sensor removed and Terminal 15 on, check Terminal 15/wakeup wire for short to ground
- With battery sensor connected and Terminal 15 off, check Terminal 15/wakeup wire for shorts to battery voltage -> Replace battery sensor
- With battery sensor connected and Terminal 15 on, check Terminal 15/wakeup wire for shorts to ground -> Replace battery sensor
No warning lamp or CC status report
No Info
0x2E8D
11917
Intelligent battery sensor, function
No Info
No Info
IBS system fault
Event-oriented
none
none
none
none
N
Serial bus signal
N
Self-diagnosis has detected internal control-module fault
Replace battery sensor
No warning lamp or CC status report
No Info
0x2F4E
12110
Vehicle speed, signal
Communication
Vehicle Speed Sensor
none
none
none
none
none
none
none
none
none
none
none
none
Fault code inactive (data content defined) Application adjustments pending on E70
0x2EA0
11936
Oil condition sensor
Engine Oil Quality Sensor
Communication
BSD communications between oil condition sensor/DME
60 sec.
Terminal 15 ON
none
none
none
none
BSD communications
Yes
QLT communications fault
Check BSD wire, voltage supply, and oil level sensor ground for open circuits, if OK replace oil level sensor
none
No oil level measurement possible
0x2EBC
11964
No BSD message from oil condition sensor
Engine Oil Quality Sensor
Communication
E65: Application data content defined E6x: Terminal 15
4 sec.
Terminal 15
none
none
10 component requests repeated 10 times before fault is logged
none
if the components fail to respond to request
Yes
BSD component failure. Malfunctions/interference in BSD bus system.
Check QLT/OZ plug. Check BSD wire. Replace defective components as indicated.
none
Revisions to application still pending for E70
0x2F4F
12111
Vehicle speed, plausibility
Vehicle Speed Sensor
Plausibility
none
none
none
none
none
none
none
none
none
none
none
none
Fault code inactive (data content defined) Application adjustments pending on E70
0x2F4F
12111
Vehicle speed, plausibility
Vehicle Speed Sensor
Plausibility
Engine speed 960 - 2000 rpm. Vehicle speed > 10 km/h. Overrun active.
3 sec.
Engine on
9 - 15 V
none
none
none
none
N
Vehicle speed low relative to reference speed. Possible incorrect DSC signal.
Check DSC
MIL on
Revisions to application still pending for E70
0x2B71
11121
Variable intake system
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU
Fault location is from the N62 with infinitely variable-geometry induction system. This fault cannot occur in the N62 T$UU
none
0x2B71
11121
Variable intake system
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU
Fault location is from the N62 with infinitely variable-geometry induction system. This fault cannot occur in the N62 T$UU
none
0x2B71
11121
Variable intake system
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU
Fault location is from the N62 with infinitely variable-geometry induction system. This fault cannot occur in the N62 T$UU
none
0x2B71
11121
Variable intake system
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU
Fault location is from the N62 with infinitely variable-geometry induction system. This fault cannot occur in the N62 T$UU
none
0x2B73
11123
Variable intake system, plausibility
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU
Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU
none
0x2B72
11122
Variable intake system, temperature warning threshold
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault location stems from the N62 with infinitely-adjustable control of induction system. Fault redundant in N62 T$UU.
Fault location stems from the N62 with infinitely-adjustable control of induction system. Fault redundant in N62 T$UU.
none
0x2B73
11123
Variable intake system, plausibility
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU
Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU
none
0x2F80
12160
System time, plausibility
Engine Off Timer, External
Electrical
CAN signal failure
Event-oriented
Terminal 30
DME operating range 6 V - 16 V
DME operating range - 40V -128 °C
Continuous as soon as CAN bus is on
none
Failure of CAN signal from power module or instrument cluster
N
CAN bus communications failure
- Check CAN bus
- Check instrument cluster/power module/CAN signals
MIL
No CC message. Revisions to application still pending for E70.
0x2B82
11138
not translated
Idle Speed Control
Cold Start RPM
Idle speed deviation during catalyst heating (150 rpm below lower limit)
8 sec.
Engine after starting with catalyst heating
none
none
Fault detection to max. 20 sec. after engine start with catalyst heating
none
Engine speed below OK sector by 150 rpm
RPM deviation: Yes
DVE disabled
Replace DVE
none
New fault location ME9.2.3
0x2B82
11138
not translated
Idle Speed Control
Cold Start RPM
Idle speed deviation during catalyst heating (400 rpm above upper limit)
8 sec.
Engine after starting with catalyst heating
none
none
Fault detection to max. 20 sec. after engine start with catalyst heating
none
RPM above OK sector by more than 400 rpm
RPM deviation: Yes
DVE disabled, vacuum leak in connection with LR adaptation fault
Replace DVE only if no LR adaptation fault has been entered (vacuum leak)
none
New fault location ME9.2.3
0x2F50
12112
No message from instrument cluster
No Info
No Info
No suspension of bus activity, no active DSC intervention, brake pedal not depressed, accelerator not depressed
0.5 sec
800 ms after Terminal 15
battery voltage >10 V
none
none
none
CAN signal for vehicle speed in instrument-cluster speedometer is invalid
Yes
Instrument cluster transmits invalidity signal
Check instrument cluster ECU Check PT-CAN
FGR/ACC is deactivated
FGR/ACC is deactivated Revisions to application still pending for E70
0x2F50
12112
No message from instrument cluster
No Info
No Info
No suspension of bus activity, no active DSC intervention, brake pedal not depressed, accelerator not depressed
0.5 sec
800 ms after Terminal 15
battery voltage >10 V
none
none
none
Speed signal transmitted by instrument cluster (rear wheel, filtered) deviates from DSC speed signal (front wheel) by more than 30 km/h.
Yes
Speed signal transmitted by instrument cluster displays excessive deviation from DSC speed signal. In rare cases this fault can be stored in response to extremely dynamic operation on loose surfaces.
Check instrument cluster ECU. Check DSC-SG. Check PT-CAN. No hardware replacement if frequency of fault is low and test of indicated ECU is OK.
FGR/ACC is deactivated
FGR/ACC is deactivated Revisions to application still pending for E70
0x2EA0
11936
Oil condition sensor
Engine Oil Quality Sensor
Temperature
Oil temperature difference >100° within 1 sec.
none
Terminal 15 ON
none
none
none
none
QLT temperature measurement
Yes
QLT temperature measurement fault
Replace oil level sensor
none
none
0x2EA0
11936
Oil condition sensor
Engine Oil Quality Sensor
Level
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault not active in ME922T$UU/ME923
Fault not active in ME922T$UU/ME923
none
Fault not active in ME922T$UU/ME92 3
0x2EA0
11936
Oil condition sensor
Engine Oil Quality Sensor
Permeability
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Fault not active in ME922T$UU/ME923
Fault not active in ME922T$UU/ME923
none
Fault not active in ME922T$UU/ME92 3
0x2D6E
11630
Control module, internal fault: monitoring of actual torque
ECM Self-Test
Torque Monitoring
Torque monitor
none
Engine running
none
none
none
none
Charge (HFM) implausible relative to calculated torque
Yes
HFM DME
Perform test measurements on wire to HFM, check HFM for contamination/replace, replace DME
Fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2DEC
11756
Power management, battery
Powermanagement
Electrical
Battery deep discharge, battery voltage low, as measured by IBS below 9.5 volts for min. 10 sec.
none
Terminal 30
DME operating range
DME operating range
After starting - IBS communications
N
IBS signal, battery voltage<9,5 Volt
IBS signal -> N
Voltage has been below 9 V for 1 min., in contrast with undervoltage fault this is also detected in vehicles in passive standby state
Check standby current draw, check and recharge battery
No warning lamp or CC status report
Fault deleted in E65 data entry
0x2DEC
11756
Power management, battery
Powermanagement
Electrical
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
none
none
Fault code not active (data loaded)
0x2DEB
11755
Power management, vehicle electrical system
Powermanagement
Electrical
Below battery voltage measured by IBS, below 16 volts for at least 10 sec.
none
Terminal 15 with engine running
DME operating range
DME operating range
No time specified, with engine running
N
IBS signal, battery voltage>16 volts
IBS signal -> N
Alternator voltage >16 V Jump-start with 24-volt battery
Has vehicle been jump-started? Fault counter =1 and fault not currently present, then delete stored fault codes from log. Otherwise check electrical system voltage, if voltage >16 V replace alternator
No warning lamp or CC status report
Fault deleted in E65 data entry
0x2DEB
11755
Power management, vehicle electrical system
Powermanagement
Electrical
Below battery voltage measured by IBS, below 9 volts for at least 10 sec.
none
Terminal 15 with engine running
DME operating range
DME operating range
No time specified, with engine running
N
IBS signal, battery voltage < 9 Volt
IBS signal -> N
Alternator, voltage < 9 V
Check electrical system voltage if < 9 V Stecker, Leitungen Generator pr$uUfen wenn I.O. Generator Tauschen
No warning lamp or CC status report
Fault deleted in E65 data entry
0x2DEB
11755
Power management, vehicle electrical system
Powermanagement
Electrical
Battery voltage measured by IBS above 18 volts or below 8.5 volts exceeded for at least 200 ms
none
Terminal 15 with engine running
DME operating range
DME operating range
No time specified, with engine running
N
IBS signal, 8.5 volts
IBS signal -> N
Battery not correctly connected.
Check threaded connections on battery terminals
CC message ""Check battery terminals""
Fault is activated in E65
0x2DED
11757
Power management, closed-circuit current violation
Powermanagement
Electrical
IBS: Detects higher standby current draw in parked phase
none
Terminal R
DME operating range
DME operating range
After starting - IBS communications
N
Calculated value from IBS
N
Standby current violation: Standby current draw exceeds the tolerated limit. Standby current is calculated only when ISD-BSD communications are not present - vehicle in sleep mode.
Conduct energy diagnosis
CC message 'High battery discharge when parked'
Increased energy consumption when parked/fault resolved by data definitions in E65
0x2DBF
11711
No message from ACC
Communication
ACC
ACC vehicle
100 ms
800 ms after Terminal 15
battery voltage >10 V
none
No new CAN messages for 40 ms, corresponds to 2 messages
none
CAN message torque demand_ACC
Yes
ECU failure (ACC) - Bus system failure - Defective bus controller (ACC)
Check ACC fuse - Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated
none
If this fault occurs when ACC is not installed, the DME has been incorrectly initialized for the ACC version. =>Check versions
0x2D00
11520
Throttle-valve actuator, spring test of closing spring
Throttle Actuator
Spring Test
Fault diagnosed only during throttle valve's adaptation phase
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
Throttle valve angle
Yes
Not possible to move DVE from emergency air position (UMA):; - Plate binding; DVE electrical activation defective
Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE
MIL on in 2nd driving cycle + EPCL
none
0x2D02
11522
Throttle-valve actuator, emergency air point
Throttle Actuator
Adaptation
Check on throttle valve's emergency default position as determined during throttle valve adaptation
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
Throttle valve angle
Yes
Failure to reach emergency air position with DVE switched off.
Replace DVE
MIL on in 2nd driving cycle
The emergency backup angle for the throttle valve calculated from the adapted data is not in sector 1.6 %-18%DK
0x2D00
11520
Throttle-valve actuator, spring test of closing spring
Throttle Actuator
Adaptation
Fault diagnosed only during throttle valve's adaptation phase
none
Terminal 15=TRUE
battery voltage>7 V
none
none
none
Throttle valve angle
Yes
Failure to reach emergency air position from open plate: - Plate binding - Defective return spring - DVE electrical activation defective
Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE
MIL on in 2nd driving cycle + EPCL
none
0x2D04
11524
Throttle-valve actuator, test of lower limit position
Throttle Actuator
Adaptation
No throttle valve adaptation conducted yet, fuel-supply safety shutdown until adaptation is successful
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
Throttle valve adaptation
Yes
Failure to reach lower mechanical travel limit:; - Travel stop contamination, foreign object; defective DVE
Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE
none
none
0x2CF1
11505
Throttle-valve actuator, position monitoring
Throttle Actuator
Position Control
Comparison of throttle valve's actual to its specified angle is greater than 0.2 sec. and less than 0.5 sec greater than a value calculated from rpm and temperature
none
Terminal 15=TRUE
battery voltage>7 V
none
0.2 sec
none
Compare actual with specified throttle valve angle
Yes
Binding, seizure, contamination on DVE - Wiring to servo motor control open - Shorted winding in servo motor
Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE
MIL on in 2nd driving cycle
none
0x2CF0
11504
Throttle-valve actuator, control range
Throttle Actuator
Throttle Stuck
Despite control signal to throttle valve> no position change detected in > 0.6 sec.
none
Terminal 15=TRUE
battery voltage>7 V
none
0.6 sec
none
none
none
Binding, seizure, contamination on DVE - Wiring to servo motor control open - Shorted winding in servo motor
Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE
MIL on in 2nd driving cycle
none
0x2CF0
11504
Throttle-valve actuator, control range
Throttle Actuator
Throttle Stuck
Despite control signal to throttle valve> No position change visible in > 5 sec.
none
Terminal 15=TRUE
battery voltage>7 V
none
5 sec.
none
none
none
Binding, seizure, contamination on DVE - Wiring to servo motor control open - Shorted winding in servo motor
Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE
MIL on in 2nd driving cycle
none
0x2B9D
11165
Control module, internal fault: overvoltage
Voltage Monitoring Control Module
Voltage
DME selftest
none
none
none
none
none
none
none
none
Internal fault in computer or internal fault in control modules
Replace DME
EPCL + various warning lamps from other ECUs, as DME is not transmitting messages to the bus
Even if the fault condition is not currently present the DME should be replaced to ensure safety
0x2B9D
11165
Control module, internal fault: overvoltage
Voltage Monitoring Control Module
Voltage
DME selftest
none
none
none
none
none
none
none
none
Internal fault in computer or internal fault in control modules
Replace DME
EPCL + various warning lamps from other ECUs, as DME is not transmitting messages to the bus
Even if the fault condition is not currently present the DME should be replaced to ensure safety
0x2B9D
11165
Control module, internal fault: overvoltage
Communication
Voltage Monitoring Control Module
DME selftest
none
none
none
none
none
none
none
none
Internal fault in computer or internal fault in control modules
Replace DME
EPCL + various warning lamps from other ECUs, as DME is not transmitting messages to the bus
Even if the fault condition is not currently present the DME should be replaced to ensure safety
0x2D03
11523
Throttle-valve actuator, cancel adaptation due to environmental conditions
No Info
No Info
Environmental conditions for throttle valve adaptation were not present
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
none
none
Adaptation aborted owing to failure to satisfy conditions. Previous adaptation valid. Fault code entry for information only
No action required
none
none
0x2D03
11523
Throttle-valve actuator, cancel adaptation due to environmental conditions
No Info
No Info
Environmental conditions for throttle valve adaptation were not present
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
none
none
Adaptation aborted owing to failure to satisfy conditions. Previous adaptation valid. Fault code entry for information only
No action required
none
none
0x2CFF
11519
Throttle-valve actuator, amplifier calibration
No Info
No Info
Fault diagnosed only during throttle valve's adaptation phase
none
Terminal 15 = TRUE + engine running
battery voltage>7 V
none
none
none
Throttle valve potentiometer 1 amplifier calibration
Yes
Fault during amplifier calibration leads to operation with unamplified signal from potentiometer 1.
Delete stored fault codes from log, delete adaptation data
EPCL
none
0x2D05
11525
Throttle-valve actuator, cancel with UMA re-learning
Throttle Actuator
Adaptation
Fault diagnosed only during throttle valve's adaptation phase
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
Throttle valve adaptation
Yes
Fault during attempt to repeat initialization; failure to reach lower mechanical travel limit:; - Travel stop contamination, foreign object; defective DVE
Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE
none
none
0x2B99
11161
Control module, internal fault: RAM backup
No Info
No Info
Not possible to read NVRAM
none
Terminal 15
none
none
none
deleted
none
N
Not possible to read from flash memory
Replace DME
none
Not possible to read from ECU flash memory. Probable reason is defective flash chip in ECU.
0x2B99
11161
Control module, internal fault: RAM backup
No Info
No Info
Not possible to write to NVRAM
none
Terminal 15
none
none
none
deleted
none
N
Not possible to write to flash memory
Replace DME
none
Not possible to write to ECU flash memory. Probable reason is defective flash chip in ECU.
0x2F59
12121
Automatic start, start signal
No Info
No Info
E65 only Engine speed > 1200 rpm
none
Terminal 15=TRUE
none
none
5 seconds after end of engine-start phase
None
Target:E_S_START On HIGH during engine starts, otherwise LOW
N
E_S_START input at ECU is present with following rpm => E_S_START shorted to battery voltage; starter engages with engine running; starter relay makes without being triggered
Check E_S_START wire; check starter and starter relay; inspect CAS-SG
No CC
If this fault is entered in an E60, check DME for correct data version/download correct data version
0x2F46
12102
EWS random code saving
No Info
No Info
none
none
Terminal 15
none
none
none
none
none
N
At least 2 failed attempts to read random code memory
Replace DME if fault recurs repeatedly, otherwise ignore.
none
none
0x2F45
12101
Interface EWS-DME
No Info
No Info
Telegram reception
3x (frame or stop bit)
Terminal 15
none
none
none
none
none
N
Defective CAS or major signal interference in the wire
Continue problem diagnosis with CAS
none
none
0x2F45
12101
Interface EWS-DME
No Info
No Info
Starting at T15 ON
none
Terminal 15
none
none
2 sec.
none
none
N
Wiring harness defect, wire D_EWS - Defect in CAS voltage supply - Defective CAS - Defective DME
Check D_EWS wire; measure with oscilloscope to see if digital signal present at DME Trigger CAS with tester, no response from CAS: Continue problem diagnosis with CAS
none
none
0x2F45
12101
Interface EWS-DME
No Info
No Info
Telegram reception
3x (parity bit)
Terminal 15
none
none
none
none
none
N
Parity bit fault (interference)
Continue problem diagnosis with CAS or code or wire from CAS to DME
none
none
0x2F46
12102
EWS random code saving
No Info
No Info
none
none
Terminal 15
none
none
none
none
none
N
At least 2 failed attempts to read random code memory
Replace DME if fault recurs repeatedly, otherwise ignore.
none
none
0x2F46
12102
EWS random code saving
No Info
No Info
none
none
Terminal 15
none
none
none
none
none
N
At lest 2 failed attempts to write WC in memory
Replace DME if fault recurs repeatedly, otherwise ignore.
none
none
0x2F44
12100
EWS preventing manipulation
No Info
No Info
Starting at T15 ON
Four incorrect random code telegrams
Terminal 15
none
none
none
none
none
N
Transmitted random code is outside monitored range:; - CAS receives no rpm signal and suspends WC switching sequence
Conduct start data calibration; start engine, n >2000 rpm for 10 sec.; engine OFF, but Terminal R remains on; restart engine when wait-state phase elapses; if engine fails to start WC in CAS does not proceed with switching sequence: Continue problem diagnosis with CAS
none
none
0x2F44
12100
EWS preventing manipulation
No Info
No Info
Starting at T15 ON
An incorrect start value telegram
Terminal 15
none
none
none
none
none
N
Fault at start value calibration:; - DME does not belong in this vehicle; DME and CAS do not support mutual operation
If DME really belongs to this vehicle, Terminal 15 OFF/ON, repeat start value calibration; => Status feedback after start value calibration has priority over FS
none
none
0x2F44
12100
EWS preventing manipulation
No Info
No Info
Starting at T15 ON
none
Terminal 15
none
none
none
none
none
N
No start value yet programmed.
First, program start value; => Status feedback after start value calibration has priority over FS
none
none
0x2F44
12100
EWS preventing manipulation
No Info
No Info
Starting at T15 ON
none
Terminal 15
none
none
none
none
none
N
Occurs during attempted start value calibration:; - Fault saving STW in the DME
Terminal 15 off/on, repeat start value calibration
none
none
0x2DBF
11711
No message from ACC
No Info
No Info
ACC vehicle
100 ms
800 ms after Terminal 15
battery voltage > 10 V
none
Checksum fault in 4 consecutive messages (80 ms)
none
CAN message torque demand_ACC
Yes
ECU failure (ACC) - Bus system failure - Defective bus controller (ACC)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness. Replace defective ECU as indicated.
none
No Info
0x2DBF
11711
No message from ACC
No Info
No Info
ACC vehicle
100 ms
800 ms after Terminal 15
battery voltage >10 V
none
Alive-counter fault in 6 consecutive messages (120 ms)
none
CAN message torque demand_ACC
Yes
ECU failure (ACC) - Bus system failure - Defective bus controller (ACC)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
No Info
0x2DBF
11711
No message from ACC
No Info
No Info
ACC vehicle
500 ms
800 ms after Terminal 15
battery voltage >10 V
none
ACC fails to retract torque demand although the brakes are applied
none
CAN message torque demand_ACC
Yes
ACC fails to retract torque demand after braking
Check ACC for fault entries => Replace defective ECU as indicated
none
No Info
0x2D70
11632
Control module, internal fault: monitoring of engine functions
Throttle Control Monitor Level 2/3
AD Converter
Torque monitor
none
nmot > 1200 rpm
none
none
none
none
AD converter internal test
N
Internal fault in computer or internal fault in control modules
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2D75
11637
Control module, internal fault: monitoring of engine speed
Throttle Control Monitor Level 2/3
RPM
Torque monitor
none
none
none
none
none
none
RPM sensor internal check
Yes
Fault in rpm plausibility check under current engine operating conditions - Defective RPM sensor - Defective DME
Check whether nmot in the General Test Data test data block is plausible (warm idle at roughly 580 RPM, governor intervention rpm 6500 RPM); if test value is not OK check/repair crankshaft sensor and wiring; if test value is OK and no fault memory entries related to crankshaft/camshaft are stored in fault log: Replace DME
EPCL + fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2D76
11638
Control module, internal fault: monitoring of accelerator pedal module
Throttle Control Monitor Level 2/3
Pedal Position Sensor
Torque monitor
none
none
battery voltage > 7 V
none
none
none
Internal check on accelerator pedal-position sensor voltage
Yes
Fault in accelerator pedal-position sensor plausibility check - Defective DME - Defective PWG
Check ADC test data in test data block. Both values must rise/fall in tandem. Check wiring harness, check data, replace accelerator pedal, check data, replace DME
EPCL + accelerator pedal emergency default mode
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2E73
11891
Control module, internal fault: knock sensor module
ECM
Knock Sensor
RPM > 1520 rpm Load factor > 25
< 10 sec.
Engine running
9 - 15 V
T mot > 40°C
none
none
none
N
Knock chip defective
Replace DME
MIL on
No Info
0x2DD7
11735
No message from DSC
No Info
No Info
No suspension of bus activity
400 ms
800 ms after Terminal 15
battery voltage > 10 V
none
No message for 40 ms
none
Check to determine whether following CAN messages are present: Speed_Wheel, Torque_demand_DSC, Stat_DSC, Speed
Yes
ECU failure (DSC) - Bus system failure - Defective bus controller (DSC)
Check DSC fuse - Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated.
none
Revisions to application still pending for E70
0x2A21
10785
not translated
Fuel Level Sensor
Electrical
No suspension of bus activity
none
Terminal 15
none
none
none
none
Signal fault is already detected in instrument cluster and relayed to the DME
N
No CAN message from instrument cluster (invalidity value)
Check CAN network (ZGM) and instrument cluster. No ZGM on E70, as replaced by JBBF.
none
New fault location ME9.2.3
0x2A21
10785
not translated
Fuel Level Sensor
Electrical
No suspension of bus activity
51 sec.
Terminal 15
none
none
none
none
Signal fault is already detected in instrument cluster and relayed to the DME
N
No CAN message from instrument cluster (invalidity value)
Check CAN network (ZGM) and instrument cluster No ZGM on E70, as replaced by JBBF
none
New fault location ME9.2.3
0x2A21
10785
not translated
Fuel Level Sensor
Electrical
No suspension of bus activity
51 sec.
Terminal 15
none
none
none
none
Signal fault is already detected in instrument cluster and relayed to the DME
N
No CAN message from instrument cluster (invalidity value)
Check CAN network (ZGM) and instrument cluster. No ZGM on E70, as replaced by JBBF.
none
New fault location ME9.2.3
0x2A80
10880
Intake VANOS, activation
Camshaft Position Actuator
Intake
Driver circuit has detected short to ground
500 ms
Terminal 15=TRUE
9.51 < ub < 17, 90
none
none
None
The pulse-duty factor calculated in vse_tv should be issued
N
Bank 1 intake VANOS - Short to ground
VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists
US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.
VANOS intake and exhaust shift to maximum adjustment (offset 60°)
0x2A80
10880
Intake VANOS, activation
Camshaft Position Actuator
Intake
Driver circuit has detected short to battery voltage
500 ms
Terminal 15=TRUE
9.51 < ub < 17, 90
none
none
None
The pulse-duty factor calculated in vse_tv should be issued
N
Bank 1 intake VANOS - Short to battery voltage
VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists.
US: MIL on in 2nd driving cycle ECE: No MIL VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.
VANOS intake and exhaust remains at travel limits (120° offset)
0x2A85
10885
Exhaust VANOS, activation
Camshaft Position Actuator
Exhaust
Driver circuit has detected short to ground
500 ms
Terminal 15=TRUE
9.51 < ub < 17, 90
none
none
None
The pulse-duty factor calculated in vsa_tv should be issued
N
Bank 1 exhaust VANOS - Short to ground
VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists
US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.
VANOS intake and exhaust shift to maximum adjustment (offset 60°)
0x2A85
10885
Exhaust VANOS, activation
Camshaft Position Actuator
Exhaust
Driver circuit has detected short to battery voltage
500 ms
Terminal 15=TRUE
9.51 < ub < 17, 90
none
none
None
The pulse-duty factor calculated in vsa_tv should be issued
N
Bank 1 exhaust VANOS - Short to battery voltage
VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists.
US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.
VANOS intake and exhaust remains at travel limits (120° offset)
0x2A81
10881
Inlet VANOS, activation 2
Camshaft Position Actuator
Intake
Driver circuit has detected short to ground
500 ms
Terminal 15=TRUE
9.51 < ub < 17, 90
none
none
None
The pulse-duty factor calculated in vse2tv should be issued
N
Bank 2 intake VANOS - Short to ground
VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists
US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.
VANOS intake and exhaust shift to maximum adjustment (offset 60°)
0x2A81
10881
Inlet VANOS, activation 2
Camshaft Position Actuator
Intake
Driver circuit has detected short to battery voltage
500 ms
Terminal 15=TRUE
9.51 < ub < 17, 90
none
none
None
The pulse-duty factor calculated in vse2tv should be issued
N
Bank 2 intake VANOS - Short to battery voltage
VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists
US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.
VANOS intake and exhaust remains at travel limits (120° offset)
0x2A86
10886
Exhaust VANOS, activation 2
Camshaft Position Actuator
Exhaust
Driver circuit has detected short to ground
500 ms
Terminal 15=TRUE
9.51 < ub < 17, 90
none
none
None
The pulse-duty factor calculated in vsa2tv should be issued
N
Bank 2 exhaust VANOS - Short to ground
VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists
US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.
VANOS intake and exhaust shift to maximum adjustment (offset 60°)
0x2A86
10886
Exhaust VANOS, activation 2
Camshaft Position Actuator
Exhaust
Driver circuit has detected short to battery voltage
500 ms
Terminal 15=TRUE
9.51 < ub < 17, 90
none
none
None
The pulse-duty factor calculated in vsa2tv should be issued
N
Bank 2 exhaust VANOS - Short to battery voltage
VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists.
US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.
VANOS intake and exhaust remains at travel limits (120° offset)
0x2C31
11313
Oxygen sensor before catalytic converter, trim control
Fuel System
Post Catalyst
Trim control I segment (precision controller with oxygen sensor behind cat.) below delta lambda threshold < -0.03; mixture (with lambda control) too lean
Fault monitoring criterion must remain present over 1 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Coolant temperature > 75°C; Catalyst temp. > 400°C
With trim control I segment active (part-load) lasts approximately 10 min. before fault code is logged
none
Delta lambda value behind cat. (dlahi_w)
Yes
- Oxygen sensor before cat. too rich
- Exhaust system leak adjacent to oxygen sensors
- Wiring harness defect (high-ohmage shunt current or similar)
- Replace LSU
- Repair leak in exhaust system
- Check wiring harness
MIL on (in 2nd driving cycle)
none
0x2C31
11313
Oxygen sensor before catalytic converter, trim control
Fuel System
Post Catalyst
Trim control I segment (precision controller with O2 sensor behind cat.) exceeds delta lambda threshold > 0.03; mixture (with lambda closed-loop control) too rich
Fault monitoring criterion must remain present over 1 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Coolant temperature > 75°C; Catalyst temp. > 400°C
With trim control I segment active (part-load) lasts approximately 10 min. before fault code is logged
none
Delta lambda value behind cat. (dlahi_w)
Yes
- oxygen sensor before cat. too lean
- Exhaust system leak adjacent to oxygen sensors
- Wiring harness defect (high-ohmage shunt current or similar)
- Replace LSU
- Repair leak in exhaust system
- Check wiring harness
MIL on (in 2nd driving cycle)
none
0x2c32
11314
Oxygen sensor before catalytic converter 2, trim control
Fuel system
Post catalyst
Trim control I segment (precision controller with oxygen sensor behind cat.) below delta lambda threshold < -0.03; mixture (with lambda control) too lean
Fault monitoring criterion must remain present over 1 sec.
Engine running
Battery voltage < 11 V oder ubatt > 16 volts
Coolant temperature > 75°C; catalyst temp. > 400°C
With trim control I segment active (part-load) lasts approximately 10 min. Before fault code is logged.
None
Cat-back delta lambda (dlahi2_w)
Yes
- Oxygen sensor before cat. Too rich
- Exhaust system leak adjacent to oxygen sensors
- Wiring harness defect (high-ohmage shunt current or similar)
- Replace LSU
- Repair leak in exhaust system
- Check wiring harness
Mil on (in 2nd driving cycle)
None
0x2C32
11314
Oxygen sensor before catalytic converter 2, trim control
Fuel System
Post Catalyst
Trim control I segment (precision controller with O2 sensor behind cat.) exceeds delta lambda threshold > 0.03; mixture (with lambda closed-loop control) too rich
Fault monitoring criterion must remain present over 1 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Coolant temperature > 75°C; Catalyst temp. > 400°C
With trim control I segment active (part-load) lasts approximately 10 min. before fault code is logged
none
Cat-back delta lambda (dlahi2_w)
Yes
- oxygen sensor before cat. too lean
- Exhaust system leak adjacent to oxygen sensors
- Wiring harness defect (high-ohmage shunt current or similar)
- Replace LSU
- Repair leak in exhaust system
- Check wiring harness
MIL on (in 2nd driving cycle)
none
0x2CEF
11503
Throttle-valve actuator, activation
Throttle Actuator
Control Motor
Direct fault report from driver circuit chip in the DME
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
none
N
Control signal to throttle valve motor from inside DME
Replace DME
MIL on in 2nd driving cycle + EPCL
none
0x2CEF
11503
Throttle-valve actuator, activation
Throttle Actuator
Control Motor
Direct fault report from driver circuit chip in the DME
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
none
N
Throttle valve motor, excessive current
Check/replace components and wiring
MIL on in 2nd driving cycle + EPCL
none
0x2CEF
11503
Throttle-valve actuator, activation
Throttle Actuator
Control Motor
Direct fault report from driver circuit chip in the DME
none
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
none
N
Throttle valve motor, short circuit between input and output sides
Check/replace components and wiring
MIL on in 2nd driving cycle + EPCL
none
0x2D1A
11546
Accelerator pedal module, pedal-position sensor
Pedal Position Sensor
D Electrical
none
none
none
none
none
none
none
none
none
Fault is logged together with potentiometer fault 1 or 2 --> For problem source see fault code 11547 or 11548
Remove fault 11547 or 11548
none
none
0x2D1B
11547
Accelerator pedal module, pedal-position sensor, signal 1
Pedal Position Sensor
D Electrical
Pedal-position sensor 1 voltage below minimum
0.14 sec
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
Voltage at pedal-position sensor 1
N
Pedal-position sensor 1 voltage below minimum - Wiring to pedal-position sensor - DME
Check whether upwg1_w in test data block ADC test data < 0.566 V ; check wiring harness, replace accelerator pedal, if upwg1_w is still < 0.566V replace DME
EPCL
none
0x2D1B
11547
Accelerator pedal module, pedal-position sensor, signal 1
Pedal Position Sensor
D Electrical
Pedal-position sensor 1 voltage above maximum
0.14 sec
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
Voltage at pedal-position sensor 1
N
Pedal-position sensor 1 voltage above maximum - Wiring to pedal-position sensor - DME
Check whether upwg1_w in test data block ADC test data > 4.805 V ; check wiring harness, replace accelerator pedal, if upwg1_w is still > 4.805 V replace DME
EPCL
none
0x2D1C
11548
Accelerator pedal module, pedal-position sensor, signal 2
Pedal Position Sensor
E Electrical
Pedal-position sensor 2 voltage below maximum
0.14 sec
Terminal 15=TRUE
battery voltage>7 V
none
none
none
Voltage at pedal-position sensor 2
N
Pedal-position sensor 2 voltage below minimum - Wiring to pedal-position sensor - DME
Check whether upwg2_w in test data block ADC test data < 0.21 V; check wiring harness, replace accelerator pedal, if upwg2_w is still < 0.21 V replace DME
EPCL
none
0x2D1C
11548
Accelerator pedal module, pedal-position sensor, signal 2
Pedal Position Sensor
E Electrical
Pedal-position sensor 2 voltage above maximum
0.14 sec
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
Voltage at pedal-position sensor 2
N
Pedal-position sensor 2 voltage above maximum - Wiring to pedal-position sensor - DME
Check whether upwg2_w in test data block. ADC test data > 2.4 V ; check wiring harness, replace accelerator pedal, if upwg2_w is still > 2.4 V replace DME
EPCL
none
0x2D1B
11547
Accelerator pedal module, pedal-position sensor, signal 1
Pedal Position Sensor
D/E Correlation
Implausible relationship between voltages for pedal-position sensors 1 and 2
0.2 sec
Terminal 15=TRUE
battery voltage > 7 V
none
none
none
Voltages for pedal-position sensor 1 and pedal-position sensor 2
N
Compare voltage for pedal-position sensor 1 with twice figure for pedal-position sensor 2
Check ADC test data in test data block. Maximum approved difference is 0.47 V. Check wiring harness, test data, replace accelerator pedal, test data, replace DME
EPCL
none
0x29ED
10733
Fuel mixture adaptation, lower engine speed range
Fuel System
Off Idle
Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too lean. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (Last) > 20% - Mass airflow > 40 kg/h - Temperature conditions met.
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) Multiplicative adaptation factor, lower range (frau_w) Rel. charge (rl_w) Mass airflow (ml_w)
Yes
Mixture too lean (approximately 20% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective
Induction vacuum leak/exhaust air leak (AFR O2 sensor!) Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29EF
10735
Fuel mixture adaptation, sumcheck fault
Fuel System
Off Idle
Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too lean. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (Last) > 20% - Mass airflow > 40 kg/h - Temperature conditions met
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w). Multiplicative adaptation factor, lower range (frau_w) Rel. charge (rl_w) Mass airflow (ml_w)
Yes
Mixture too lean (approximately 20% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective.
Induction vacuum leak/exhaust air leak (AFR O2 sensor!), Low fuel pressure, Check oxygen sensors before cat. Check tank EVAP air discharge (air leak!) Check HFM (contamination, defect)
US MIL on (2nd driving cycle)
Revisions to application still pending for E70
0x29ED
10733
Fuel mixture adaptation, lower engine speed range
Fuel System
Off Idle
Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too rich, Release conditions: - No active tank ventilation - No fault preventing diagnosis is present - Relative charge (load) > 20% - Mass airflow > 40 kg/h - Temperature conditions met
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) Multiplicative adaptation factor, lower range (frau_w) Rel. charge (rl_w) Mass airflow (ml_w)
Yes
Rich mixture (approximately 20% Deviation): Possible causes: - Fuel pressure too high (regulator, return line plugged) - Defective mass airflow meter - Defect in PCV - Oxygen sensors before cat. defective
High fuel pressure, Check positive crankcase ventilation, Check HFM (contamination, defective), Check oxygen sensors before cat.
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29EF
10735
Fuel mixture adaptation, sumcheck fault
Fuel System
Off Idle
Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too rich, Release conditions: - No active tank ventilation - No fault preventing diagnosis is present - Relative charge (load) > 20% - Mass airflow > 40 kg/h - Temperature conditions met
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) Multiplicative adaptation factor, lower range (frau_w) Rel. charge (rl_w) Mass airflow (ml_w)
Y
Rich mixture (approximately 20% Deviation): Possible causes: - Fuel pressure too high (regulator, return line plugged) - Defective mass airflow meter - Defect in PCV - Oxygen sensors before cat. defective
High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.
US MIL on (2nd driving cycle)
Revisions to application still pending for E70
0x29EE
10734
Fuel mixture adaptation 2, lower engine speed range
Fuel System
Off Idle
Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too lean. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (Last) > 20% - Mass airflow > 40 kg/h - Temperature conditions met
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) Multiplicative adaptation value, lower range (frau2_w) Rel. charge (rl_w) Mass airflow (ml_w)
Yes
Mixture too lean (approximately 20% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective
Induction vacuum leak/exhaust air leak (AFR O2 sensor!) - Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29F0
10736
Fuel mixture adaptation 2, sumcheck fault
Fuel System
Off Idle
Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too lean Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (Last) > 20% - Mass airflow > 40 kg/h - Temperature conditions met
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) Multiplicative adaptation value, lower range (frau2_w) Rel. charge (rl_w) Mass airflow (ml_w)
Yes
Mixture too lean (approximately 20% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective
Induction vacuum leak/exhaust air leak (AFR O2 sensor!). Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)
US MIL on (2nd driving cycle)
Revisions to application still pending for E70
0x29EE
10734
Fuel mixture adaptation 2, lower engine speed range
Fuel System
Off Idle
Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too rich. Release conditions: - No active tank ventilation - No fault preventing diagnosis is present - Relative charge (load) > 20% - Mass airflow > 40 kg/h - Temperature conditions met
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) Multiplicative adaptation value, lower range (frau2_w) Rel. charge (rl_w) Mass airflow (ml_w)
Yes
Rich mixture (approximately 20% Deviation): Possible causes: - Fuel pressure too high (regulator, return line plugged) - Defective mass airflow meter - Defect in PCV - Oxygen sensors before cat. defective
High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29F0
10736
Fuel mixture adaptation 2, sumcheck fault
Fuel System
Off Idle
Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too rich - Release conditions: - No active tank ventilation - No fault preventing diagnosis is present - Relative charge (load) > 20% - Mass airflow > 40 kg/h - Temperature conditions met
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) Multiplicative adaptation value, lower range (frau2_w) Rel. charge (rl_w) Mass airflow (ml_w)
Yes
Rich mixture (approximately 20% Deviation): Possible causes: - Fuel pressure too high (regulator, return line plugged) - Defective mass airflow meter - Defect in PCV - Oxygen sensors before cat. defective
High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.
US MIL on (2nd driving cycle)
Revisions to application still pending for E70
0x2EEC
12012
Temperature sensor cooler outlet, plausibility
Engine Coolant Temperature Sensor
2 Plausibility
Stuck check
10 sec.
Engine running
none
tmst < 30°C
none
none
0.1 - 4.9 V
N
Defective sensor, thermostat out of tolerance (opens too late)
Replace sensor, thermostat, plug, wiring harness
MIL on
Revisions to application still pending for E70
0x2EEA
12010
Temperature sensor cooler outlet, signal
Engine Coolant Temperature Sensor
2 Electrical
Short to positive, open wire
10 sec.
Terminal 15 ON
none
none
none
N
Radiator discharge temperature sensor voltage > 4.94 V
N
Wire fallen off/open wire/short to battery voltage
Plug/check wiring harness, if OK replace component
MIL on (US only, in 2nd driving cycle)
No Info
0x2EEA
12010
Temperature sensor cooler outlet, signal
Engine Coolant Temperature Sensor
2 Electrical
Short to ground
10 sec.
Terminal 15 ON
none
none
none
N
Radiator discharge temperature sensor voltage < 0.254 V
N
Input voltage too low/short to ground
Plug/check wiring harness, if OK replace component
MIL on (US only, in 2nd driving cycle)
No Info
0x29E7
10727
Fuel mixture adaptation, idling, per time unit
Fuel System
Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too lean - Release conditions: - No active EVAP purge air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions.
Approximately 10 min.
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) Additive adaptation value, per time unit (rkat_w) Mass airflow ml_w
Yes
Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Injector valve out of tolerance - Valvetronic: Valve travel at idle
Induction vacuum leak/exhaust air leak (AFR O2 sensor !) Low fuel pressure Check oxygen sensors before cat. Check tank EVAP air discharge (air leak !) Check HFM (contamination, defect)
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29EF
10735
Fuel mixture adaptation, sumcheck fault
Fuel System
Idle
Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too lean Release conditions: - No active EVAP purge air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C. Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) Additive adaptation value, per time unit (rkat_w) Mass airflow ml_w
Yes
Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Injector valve out of tolerance - Valvetronic: Valve travel at idle
Induction vacuum leak/exhaust air leak (AFR O2 sensor!). Low fuel pressure Check oxygen sensors before cat. Check tank EVAP air discharge (air leak!) Check HFM (contamination, defect)
US MIL on (2nd driving cycle)
Revisions to application still pending for E70
0x29E7
10727
Fuel mixture adaptation, idling, per time unit
Fuel System
Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too rich. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions
Approximately 10 min.
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) Additive adaptation value, per time unit (rkat_w) Mass airflow ml_w
Yes
Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line) - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Fuel injector valve out of tolerance - Valvetronic: Valve travel too low at idle
Check fuel pressure (regulator, return line). Check oxygen sensors before cat. Check tank EVAP purge air discharge (air leak !) Check HFM (contamination, defect)
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29EF
10735
Fuel mixture adaptation, sumcheck fault
Fuel System
Idle
Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too rich Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions.
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) Additive adaptation value, per time unit (rkat_w) Mass airflow ml_w
Yes
Rich mixture (approximately 23 % Deviation): Possible causes: - High fuel pressure (regulator, return line) - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Fuel injector valve out of tolerance - Valvetronic: Valve travel too low at idle
Check fuel pressure (regulator, return line). Check oxygen sensors before cat. Check tank EVAP purge air discharge (air leak !) Check HFM (contamination, defect)
US MIL on (2nd driving cycle)
Revisions to application still pending for E70
0x29E8
10728
Fuel mixture adaptation 2, idling, per time unit
Fuel System
Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too lean Release conditions: - No active EVAP purge air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions
Approximately 10 min.
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) Additive adaptation value, per time unit (rkat2_w) Mass airflow ml_w
Yes
Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Injector valve out of tolerance - Valvetronic: Valve travel at idle
Induction vacuum leak/exhaust air leak (AFR O2 sensor!) - Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29F0
10736
Fuel mixture adaptation 2, sumcheck fault
Fuel System
Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too lean - Release conditions: - No active EVAP purge air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions
Approximately 10 min.
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) Additive adaptation value, per time unit (rkat2_w) Mass airflow ml_w
Yes
Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Injector valve out of tolerance - Valvetronic: Valve travel at idle
Induction vacuum leak/exhaust air leak (AFR O2 sensor!) Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)
US MIL on (2nd driving cycle)
Revisions to application still pending for E70
0x29E8
10728
Fuel mixture adaptation 2, idling, per time unit
Fuel System
Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too rich - Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions
Approximately 10 min.
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) Additive adaptation value, per time unit (rkat2_w) Mass airflow ml_w
Yes
Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line) - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Fuel injector valve out of tolerance - Valvetronic: Valve travel too low at idle
Check fuel pressure (regulator, return line). Check oxygen sensors before cat. Check tank EVAP purge air discharge (air leak!) Check HFM (contamination, defect)
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29F0
10736
Fuel mixture adaptation 2, sumcheck fault
Fuel System
Idle
Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too rich. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) - Additive adaptation value, per time unit (rkat2_w) - Mass airflow ml_w
Yes
Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line) - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Fuel injector valve out of tolerance - Valvetronic: Valve travel too low at idle
Check fuel pressure (regulator, return line) - Check oxygen sensors before cat. - Check tank EVAP purge air discharge (air leak!) - Check HFM (contamination, defect)
US MIL on (2nd driving cycle)
Revisions to application still pending for E70
0x29E5
10725
Fuel mixture adaptation, upper engine speed range
Fuel System
Higher Load
Fuel-supply system monitored with aid of mixture adaptation data; here upper part-load range (multiplicative adaptation), system too lean Release conditions: - No active EVAP purge-air discharge - No faults that disable diagnosis are present - Relative charge (load) > 55% - Mass airflow > 250 kg/h - Compliance with temperature conditions
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) - Multiplicative adaptation value, upper range (frao_w) - Rel. charge (rl_w) - Mass airflow ml_w
Yes
Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective
Induction vacuum leak/exhaust air leak (AFR O2 sensor!) - Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29E5
10725
Fuel mixture adaptation, upper engine speed range
Fuel System
Higher Load
Fuel-supply system monitored with aid of mixture adaptation data; here upper part-load range (multiplicative adaptation), system too rich Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (load) > 55% - Mass airflow > 250 kg/h - Compliance with temperature conditions
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr_w) Multiplicative adaptation value, upper range (frao_w) Rel. charge (rl_w) Mass airflow ml_w
Yes
Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line obstructed) - Defective mass airflow meter - Defect in positive crankcase ventilation - Defect in O2 sensors
High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29E6
10726
Fuel mixture adaptation 2, upper engine speed range
Fuel System
Higher Load
Fuel-supply system monitored with aid of mixture adaptation data; here upper part-load range (multiplicative adaptation), system too lean Release conditions: - No active EVAP purge-air discharge - No faults that disable diagnosis are present - Relative charge (load) > 55% - Mass airflow > 250 kg/h - Compliance with temperature conditions
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w). Multiplicative adaptation value, upper range (frao2_w) Rel. charge (rl_w) Mass airflow ml_w
Yes
Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective
Induction vacuum leak/exhaust air leak (AFR O2 sensor!) Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x29E6
10726
Fuel mixture adaptation 2, upper engine speed range
Fuel System
Higher Load
Fuel-supply system monitored with aid of mixture adaptation data; here upper part-load range (multiplicative adaptation), system too rich. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (load) > 55% - Mass airflow > 250 kg/h - Compliance with temperature conditions
Approximately 10 min.
Engine running
battery voltage < 11 volts or battery voltage > 16 volts
Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C
Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)
none
Lambda control factor (fr2_w) Multiplicative adaptation value, upper range (frao2_w) Rel. charge (rl_w) Mass airflow ml_w
Yes
Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line obstructed) - Defective mass airflow meter - Defect in positive crankcase ventilation - Defect in O2 sensors
High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.
ECE MIL on (2nd cycle)
Revisions to application still pending for E70
0x2C49
11337
Oxygen sensor before catalytic converter, plausibility
Oxygen Sensor, Front
Signal Check
Comparison of oxygen sensor before/behind cat. signals: Sensor before cat. lean and sensor behind cat. rich. Diagnosis conditions: - Active lambda control before cat. - Sensor behind cat. ready for operation and checked - Partial trim control (with sensor behind cat. active) active.
If fault conditions are present, integrate exhaust system mass flow rate until threshold value is reached. Fault criterion: Lambda > 1.1 (lean) and U_Cat-back sensor > 0.75 V (rich)
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Coolant temperature > 75°C
Approximately 50 sec. once sensor before/behind cat. reaches operational standby status
none
Monitored lambda value on sensor before cat.(lamsoni_w). Sensor voltage on sensor behind cat. (ushk_w)
lamsoni_w: J ushk_w: N
- LSU response curve shift toward lean side
- Exhaust system leak adjacent to oxygen sensor before/behind cat
- Wiring harness defect on O2 sensor wires (high-resistance shunt)
- LSU-replace O2 sensor
- Repair exhaust system leak
- Check wiring harness
MIL on (in 2nd driving cycle)
Revisions to application still pending for E70
0x2C49
11337
Oxygen sensor before catalytic converter, plausibility
Oxygen Sensor, Front
Signal Check
Comparison of before cat./behind cat. O2 sensor signals: Sensor before cat. rich and sensor behind cat. lean. Diagnosis conditions: - Active lambda control before cat. - Sensor behind cat. ready for operation and checked - Partial trim control (with sensor behind cat. active) active
If exhaust system mass airflow integration fault conditions are present, until threshold value is reached Fault criterion: Lambda < 0.90 (rich) and U_cat-back sensor < 0.15 V (lean)
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Coolant temperature > 75°C
Approximately 50 sec. once sensor before/behind cat. reaches operational standby status
none
Monitored lambda value on sensor before cat.(lamsoni_w). Sensor voltage on sensor behind cat. (ushk_w).
lamsoni_w: J ushk_w: N
- LSU response curve shift toward rich side
- Exhaust system leak adjacent to oxygen sensor before/behind cat.
- Wiring harness defect on O2 sensor wires (high-resistance shunt)
- LSU-replace O2 sensor
- Repair exhaust system leak
- Check wiring harness
MIL on (in 2nd driving cycle)
Revisions to application still pending for E70
0x2C4A
11338
Oxygen sensor before catalytic converter 2, plausibility
Oxygen Sensor, Front
Signal Check
Comparison of oxygen sensor before/behind cat. signals: Sensor before cat. lean and sensor behind cat. rich. Diagnosis conditions: - Active lambda control before cat. - Sensor behind cat. ready for operation and checked - Partial trim control (with sensor behind cat. active) active.
If exhaust system mass airflow integration fault conditions are present, until threshold value is reached. Fault criterion: Lambda > 1.1 and U_Oxygen sensor behind cat. > 0.75 V
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Coolant temperature > 75°C
Approximately 50 sec. once sensor before/behind cat. reaches operational standby status
none
Monitored lambda value on sensor before cat. (lamsoni2_w). Sensor voltage on sensor behind cat. (ushk2_w)
lamsoni_w: J ushk_w: N
- LSU response curve shift toward lean side
- Exhaust system leak adjacent to oxygen sensor before/behind cat
- Wiring harness defect on O2 sensor wires (high-resistance shunt)
- Replace LSU O2 sensor
- Repair leak in exhaust system
- Check wiring harness
MIL on (in 2nd driving cycle)
Revisions to application still pending for E70
0x2C4A
11338
Oxygen sensor before catalytic converter 2, plausibility
Oxygen Sensor, Front
Signal Check
Comparison of before cat./behind cat. O2 sensor signals: Sensor before cat. rich and sensor behind cat. lean. Diagnosis conditions: - Active lambda control before cat. - Sensor behind cat. ready for operation and checked - Partial trim control (with sensor behind cat. active) active.
If exhaust system mass airflow integration fault conditions are present, until threshold value is reached. Fault criterion: Lambda < 0.90 (rich) and U_cat-back sensor < 0.15 V (lean)
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Coolant temperature > 75°C
Approximately 50 sec. once sensor before/behind cat. reaches operational standby status
none
Monitored lambda value on sensor before cat. (lamsoni2_w). Sensor voltage on sensor behind cat. (ushk2_w)
lamsoni_w: J ushk_w: N
- LSU response curve shift toward rich side
- Exhaust system leak adjacent to oxygen sensor before/behind cat.
- Wiring harness defect on O2 sensor wires (high-resistance shunt)
- Replace LSU O2 sensor
- Repair leak in exhaust system
- Check wiring harness
MIL on (in 2nd driving cycle)
Revisions to application still pending for E70
0x2F78
12152
Control module, internal fault: ambient-pressure sensor
Ambient Pressure Sensor
Electrical
Internal voltage measurement in ambient pressure sensor U > 4.7998
1 sec.
Terminal 15=TRUE
9 V < U > 16 V
none
none
none
Analog V
N
Short to ground
Replace DME
MIL on in 2nd DC, US version only
none
0x2F78
12152
Control module, internal fault: ambient-pressure sensor
Ambient Pressure Sensor
Electrical
Internal voltage measurement in ambient pressure sensor U > 4.7998
1 sec.
Terminal 15=TRUE
9 V < U > 16 V
none
none
none
Analog V
N
Short to battery voltage
Replace DME
MIL on in 2nd DC, US version only
none
0x2C37
11319
Oxygen sensor before catalytic converter, heater coupling
Oxygen Sensor, Front
Heater
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
none
none
Fault code not active (data loaded)
0x2C38
11320
Oxygen sensor before catalytic converter 2, heater coupling
Oxygen Sensor, Front
Heater
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
none
none
Fault code not active (data loaded)
0x2C4D
11341
Oxygen sensor before catalytic converter, pump current cable
Oxygen Sensor, Front
Positive Current
Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Lambda specification outside 3% relative to lambda = 1 - Voltage at CJ125 at 1.5 V (1.49?.1.51 V) - Closed-loop lambda control active.
Fault monitoring criterion must remain present over 2 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
2 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo_w) (1.5 volts = Lambda = 1). Closed-loop control factor (fr2_w)
Yes
Open pump current wire
Check plugs/wiring harness, otherwise replace sensor
MIL on (in 2nd driving cycle)
none
0x2C4E
11342
Oxygen sensor before catalytic converter 2, pump current cable
Oxygen Sensor, Front
Positive Current
Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Lambda specification outside 3% relative to lambda = 1 - Voltage at CJ125 at 1.5 V (1.49?.1.51 V) - Closed-loop lambda control active.
Fault monitoring criterion must remain present over 2 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
2 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) (1.5 volts = Lambda = 1). Closed-loop control factor (fr2_w)
Yes
Open pump current wire
Check plugs/wiring harness, otherwise replace sensor
MIL on (in 2nd driving cycle)
none
0x2C51
11345
Oxygen sensor before catalytic converter, Nernst cable
Oxygen Sensor, Front
Reference Voltage
Monitoring on missing Nernst voltage wire (UN); Diagnosis conditions: - No fault recognized on O2 sensor heater driver circuit - O2 sensor voltage in implausible range (Ua < 0.2 V or > 4.7 V
Fault monitoring criterion must remain present over 1 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
1 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo_w)
Yes
Implausible Nernst cell internal resistance, too high, and UA output signal after deactivation of 3kHz-Ri test frequency either high or low; Nernst wire or virtual ground missing
Check plug/wiring harness/O2 wiring, otherwise replace O2 sensor
MIL on (in 2nd driving cycle)
none
0x2C52
11346
Oxygen sensor before catalytic converter 2, Nernst cable
Oxygen Sensor, Front
Reference Voltage
Monitoring on missing Nernst voltage wire (UN); Diagnosis conditions: - No fault recognized on O2 sensor heater driver circuit - O2 sensor voltage in implausible range (Ua < 0.2 V or > 4.7 V
Fault monitoring criterion must remain present over 1 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
1 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo_w)
Yes
Implausible Nernst cell internal resistance, too high, and UA output signal after deactivation of 3kHz-Ri test frequency either high or low; Nernst wire or virtual ground missing
Check plug / wiring harness / O2 wiring, otherwise replace O2 sensor
MIL on (in 2nd driving cycle)
none
0x2C53
11347
Oxygen sensor before catalytic converter, virtual ground
Oxygen Sensor, Front
Negative Current
Monitoring for disconnected virtual ground wire (VM); Diagnosis conditions: - Overrun cutoff not active - O2 sensor voltage is in 1.5 V range f. open wire - No other faults are present for the LSU O2 sensor - Fault detected through measured high internal resistance (rinlsu2_w>1800 ohms)
Fault monitoring criterion must remain present over 5 sec.
Engine running
battery voltage < 11V oder Ubatt > 16 volts
none
5 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo_w). Internal resistance of LSU from CJ125 (rinlsu_w).
Yes
- Open wire on O2 sensor
- Open circuit at plug/wiring harness/control module
Check plug/wiring harness/O2 wiring, otherwise replace O2 sensor
MIL on (in 2nd driving cycle)
none
0x2C54
11348
Oxygen sensor before catalytic converter 2, virtual ground
Oxygen Sensor, Front
Negative Current
Monitoring for disconnected virtual ground wire (VM); Diagnosis conditions: - Overrun cutoff not active - O2 sensor voltage is in 1.5 V range f. open wire - No other faults are present for the LSU O2 sensor - Fault detected through measured high internal resistance (rinlsu2_w>1800 ohms)
Fault monitoring criterion must remain present over 5 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
5 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) Internal resistance of LSU from CJ125 (rinlsu2_w)
Yes
- Open wire on O2 sensor
- Open circuit at plug/wiring harness/control module
Check plug/wiring harness/O2 wiring, otherwise replace O2 sensor
MIL on (in 2nd driving cycle)
none
0x2C6D
11373
Oxygen sensor behind catalytic converter, ageing
Oxygen Sensor, Rear
Signal Check
Cat-back sensor heated to adequate level
Time 120 sec./continuous
Terminal 15 on Engine running
Battery voltage 11V < battery voltage < 16V
none
400 sec. after drive at 80 km/h
Oxygen sensor behind cat. voltage U < 0.65 V
Signal from O2 sensor -> N
Fault in oscillation test: Signal stuck on lean
Replace LSH
MIL on
Vehicle must be moved (80 km/h). Revisions to application still pending for E70.
0x2C6D
11373
Oxygen sensor behind catalytic converter, ageing
Oxygen Sensor, Rear
Signal Check
Cat-back sensor heated to adequate level
Time 120 sec./continuous
Terminal 15 on Engine running
Battery voltage 11 V < battery voltage < 16 V
none
400 sec. after drive at 80 km/h
Oxygen sensor behind cat. voltage U > 0.65 V
Signal from O2 sensor -> N
Fault in oscillation test: Signal stuck on rich
Replace LSH
MIL on
Vehicle must be moved (80 km/h). Revisions to application still pending for E70.
0x2C6E
11374
Oxygen sensor behind catalytic converter 2, ageing
Oxygen Sensor, Rear
Signal Check
Cat-back sensor heated to adequate level
Time 120 sec./continuous
Terminal 15 on Engine running
Battery voltage 11 V < battery voltage < 16 V
none
400 sec. after drive at 80 km/h
Oxygen sensor behind cat. voltage U < 0.65 V
Signal from O2 sensor -> N
Fault in oscillation test: Signal stuck on lean.
Replace LSH
MIL on
Vehicle must be moved (80 km/h) Revisions to application still pending for E70
0x2C6E
11374
Oxygen sensor behind catalytic converter 2, ageing
Oxygen Sensor, Rear
Signal Check
Cat-back sensor heated to adequate level
Time 120 sec./continuous
Terminal 15 on Engine running
Battery voltage 11 V < battery voltage < 16 V
none
400 sec. after drive at 80 km/h
Oxygen sensor behind cat. voltage U > 0.65 V
Signal from O2 sensor -> N
Fault in oscillation test: Signal stuck on rich
Replace LSH
MIL on
Vehicle must be moved (80 km/h). Revisions to application still pending for E70.
0x2A13
10771
DMTL leak diagnosis pump, activation
EVAP System
Pump
Open circuit
none
Terminal 15 ON
9.5 < U (V) < 17
none
standing/continuous
P2400
analog
N
Driver circuit has detected open wire
Check plug/wiring harness, otherwise replace pump motor
MIL on in 2nd DC
OBD I fault
0x2A13
10771
DMTL leak diagnosis pump, activation
EVAP System
Pump
Short to ground
none
Terminal 15 ON
9.5 < U (V) < 17
none
standing/continuous
P2401
analog
N
Driver circuit has detected short to ground
Check plugs/check wiring harness, otherwise replace DM-TL
MIL on in 2nd DC
OBD I fault
0x2A13
10771
DMTL leak diagnosis pump, activation
EVAP System
Pump
Short to positive
none
Terminal 15 ON
9.5 < U (V) < 17
none
standing/continuous
P2402
analog
N
Driver circuit has detected short to battery voltage
Check plugs/check wiring harness, otherwise replace DM-TL
MIL on in 2nd DC
OBD I fault
0x2A18
10776
DMTL, heater: activation
EVAP System
DMTL Heater
Open circuit
none
Terminal 15 off/on
9.5 < U (V) < 17
> 4°C < 35°C
At control-activation system test or start of OBD II diagnosis
P1429
analog
N
Driver circuit has detected open wire
Check wiring harness, otherwise replace DME
MIL ON
N
0x2A18
10776
DMTL, heater: activation
EVAP System
DMTL Heater
Short to ground
none
Terminal 15 off/on
9.5 < U (V) < 17
> 4°C < 35°C
At control-activation system test or start of OBD II diagnosis
P1430
analog
N
Driver circuit has detected short to ground
Check wiring harness, otherwise replace DME
MIL ON
N
0x2A18
10776
DMTL, heater: activation
EVAP System
DMTL Heater
Short to positive
none
Terminal 15 off/on
9.5 < U (V) < 17
> 4°C < 35°C
At control-activation system test or start of OBD II diagnosis
P1431
analog
N
Driver circuit has detected short to battery voltage
Check wiring harness, otherwise replace DME
MIL ON
N
0x2C3B
11323
Oxygen sensor before catalytic converter, not connected
Oxygen Sensor, Front
Exhaust Sample Error
Diagnosis recognizes one O2 sensor connected to wiring harness, but not connected to exhaust system. Diagnosis activation conditions: - Overrun cutoff cannot be active ! - No other O2 sensor faults - Sensor must be adequately heated
Fault monitoring criterion must be present longer than 10 sec. (with tank empty: 610 sec.)
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
Approximately 15--125 sec. after start; with tank empty: 600 sec. longer
none
Voltage. CJ125 chip (ua10mo_w)
Yes
O2 sensor is outside the exhaust system, but still connected to the wiring harness
Install O2 sensor with connected plug in exhaust system
MIL on (in 2nd driving cycle)
Revisions to application still pending for E70
0x2C3C
11324
Oxygen sensor before catalytic converter 2, not connected
Oxygen Sensor, Front
Exhaust Sample Error
Diagnosis recognizes one O2 sensor connected to wiring harness, but not connect to exhaust system. Diagnosis activation conditions: - Overrun cutoff cannot be active! - No other O2 sensor faults - Sensor must be adequately heated
Fault monitoring criterion must be present longer than 10 sec. (with tank empty: 610 sec.)
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
Approximately 15--125 sec. after start; with tank empty: 600 sec. longer
none
Voltage. CJ125 chip (ua10mo2_w)
Yes
O2 sensor is outside the exhaust system, but still connected to the wiring harness
Install O2 sensor with connected plug in exhaust system
MIL on (in 2nd driving cycle)
Revisions to application still pending for E70
0x2A12
10770
DMTL solenoid valve, activation
EVAP System
Switching Valve
Open circuit
none
Terminal 15 ON
9.5 < U (V) < 17
none
standing/continuous
P2418
analog
N
Driver circuit has detected open wire
Check wiring harness, otherwise replace DME
MIL on in 2nd DC
OBD I fault
0x2A12
10770
DMTL solenoid valve, activation
EVAP System
Switching Valve
Short to negative
none
Terminal 15 ON
9.5 < U (V) < 17
none
standing/continuous
P2419
analog
N
Driver circuit has detected short to ground
Check plugs/check wiring harness, otherwise replace DM-TL
MIL on in 2nd DC
OBD I fault
0x2A12
10770
DMTL solenoid valve, activation
EVAP System
Switching Valve
Short to positive
none
Terminal 15 ON
9.5 < U (V) < 17
none
standing/continuous
P2420
analog
N
Driver circuit has detected short to battery voltage
Check plugs/check wiring harness, otherwise replace DM-TL
MIL on in 2nd DC
OBD I fault
0x2F9E
12190
Thermal oil-level sensor
Engine Oil Level Sensor
Electrical
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
none
none
Cannot occur on N62T$UU!
0x2F9E
12190
Thermal oil-level sensor
Engine Oil Level Sensor
Plausibility
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
none
none
Cannot occur on N62T$UU!
0x2F9E
12190
Thermal oil-level sensor
Engine Oil Level
Level
Oil sensor has detected low oil level
Oil level has been measured
Engine running
none
none
none
none
Oil sensor, oil level
Yes
Low engine oil level
Top up engine oil
Oil warning lamp
none
0x2C4F
11343
Oxygen sensor before catalytic converter, calibration cable
Oxygen Sensor, Front
Pumping Current
Monitoring on disconnected calibration wire (IA); Diagnosis conditions: - Trailing-throttle overrun abort present for at least 2 sec. - Voltage at CJ125 > 4.8 V - O2 sensor heated to adequate temperature - Exhaust-gas temp. (model) before cat. < 750°C
Fault monitoring criterion must remain present over 1 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Exhaust-gas temperature (model) < 750°C
1 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo_w) (voltage at air = 4.2 V) Overrun cutoff condition (B_sa=1)
Yes
Calibration wire (wire for sensor calibration resistor in sensor plug) disconnected
Check plug / wiring harness / O2 wiring, otherwise replace O2 sensor
MIL on (in 2nd driving cycle)
none
0x2C50
11344
Oxygen sensor before catalytic converter 2, calibration cable
Oxygen Sensor, Front
Pumping Current
Monitoring on disconnected calibration wire (IA); Diagnosis conditions: - Trailing-throttle overrun abort present for at least 2 sec. - Voltage at CJ125 > 4.8 V - O2 sensor heated to adequate temperature - Exhaust-gas temp. (model) before cat. < 750°C
Fault monitoring criterion must remain present over 1 sec.
Engine running
battery voltage <11 V oder Ubatt > 16 volts
Exhaust-gas temperature (model) < 750°C
1 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) (voltage at air = 4.2 V) Overrun cutoff condition (B_sa=1)
Yes
Calibration wire (wire for sensor calibration resistor in sensor plug) disconnected
Check plug/wiring harness/O2 wiring, otherwise replace O2 sensor
MIL on (in 2nd driving cycle)
none
0x2F0D
12045
Radiator blind, activation, (GLF)
No Info
No Info
Current at Pin 4--31 I > 1.9 A
n> 40 rpm
Terminal 15=TRUE
9.5 V < U < 17.9 V
none
after 500 ms
steuern_glf
Low Side control signal
Yes
Driver circuit has detected short to battery voltage
Check wiring harness, otherwise replace DME
MIL ON in 2nd DC
none
0x2F0D
12045
Radiator blind, activation, (GLF)
No Info
No Info
Current at Pin 4--31 I > 1.9 A
n> 40 rpm
Terminal 15=TRUE
9.5 V < U < 17.9 V
none
after 500 ms
steuern_glf
Low Side control signal
Yes
Driver circuit has detected short to ground
Check wiring harness, otherwise replace DME
MIL ON in 2nd DC
none
0x2F0D
12045
Radiator blind, activation, (GLF)
No Info
No Info
Current at Pin 4--31 I > 1.9 A
n> 40 rpm
Terminal 15=TRUE
9.5 V < U < 17.9 V
none
after 500 ms
steuern_glf
Low Side control signal
Yes
Driver circuit has detected open wire
Check wiring harness, otherwise replace DME
MIL ON in 2nd DC
none
0x2C4B
11339
Control module, internal fault: oxygen sensor module
Oxygen Sensor, Front
ECM Self-Test
Monitor for voltage adaptation value electr. calibration of CJ125 IC Calibration runs after engine start and in idle phases
Fault criterion: Calibration adaptation value > 0.1 volts Fault entry after 10 sec.
Terminal 15 ON
battery voltage<11V oder Ubatt > 16 volts
none
10 sec.
none
Correction value for standard response curve (v=17): kusvk_w Correction value for rich response curve (v=8): kusvkft_w
Y
Offset correction value is above the maximum approved threshold value
- Check wiring harness
- Replace control module
MIL on (in 2nd driving cycle)
none
0x2C4C
11340
Control module, internal fault: oxygen sensor module 2
Oxygen Sensor, Front
ECM Self-Test
Monitor for voltage adaptation value electr. calibration of CJ125 IC Calibration runs after engine start and in idle phases
Fault criterion: Calibration adaptation value > 0.1 volts Fault entry after 10 sec.
Terminal 15 ON
battery voltage<11V oder Ubatt > 16 volts
none
10 sec.
none
Correction figure of standard response curve (v=17): kusvk2_w Correction figure for rich response curve (v=8): kusvkft2_w
Yes
Offset correction value is above the maximum approved threshold value
- Check wiring harness
- Replace control module
MIL on (in 2nd driving cycle)
none
0x2C4B
11339
Control module, internal fault: oxygen sensor module
Oxygen Sensor, Front
ECM Self-Test
Monitor for CJ125 chip power supply; voltage too low
Fault monitoring criterion must remain present over 2 sec.
Terminal 15 ON
battery voltage < 11V oder Ubatt > 16 volts
none
2 sec.
none
Internal diagnosis in CJ125 chip
none
Internal HW fault in control module
Replace control module
MIL on (in 2nd driving cycle)
none
0x2C4C
11340
Control module, internal fault: oxygen sensor module 2
Oxygen Sensor, Front
ECM Self-Test
Monitor for CJ125 chip power supply; voltage too low
Fault monitoring criterion must remain present over 2 sec.
Terminal 15 ON
battery voltage < 11 V oder Ubatt > 16 volts
10 sec./continuous
2 sec.
none
Internal diagnosis in CJ125 chip
none
none
Replace control module
MIL on (in 2nd driving cycle)
none
0x2CA0
11424
Oxygen sensor heating before catalytic converter
Oxygen Sensor, Front
ECM Self-Test
Calibration resistance in CJ 125 chip monitored for LSU heater control (Specified calibration resistance in control module: 300 ohms) Fault status recognized when adapted correction value (krivk_w) > 45 ohms
25 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
Diagnosis begins at start if 11 V < battery voltage < 16 V
none
Adapted correction value (krivk_w) > 45 ohms
Yes
Difference between nominal value of calibration resistance and measured calibration resistance exceeds 45 ohms
Replace control module
MIL on (in 2nd driving cycle)
Internal HW fault in ECU; resets O2 sensor operational standby status Application adjustments pending for E70
0x2CA1
11425
Oxygen sensor heating before catalytic converter 2
Oxygen Sensor, Front
ECM Self-Test
Calibration resistance in CJ 125 chip monitored for LSU heater control (Specified calibration resistance in control module: 300 ohms) Fault status recognized when adapted correction value (krivk_w) > 45 ohms
25 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
none
Diagnosis begins at start if 11 V < battery voltage < 16 V
none
Adaptive correction value (krivk2_w) > 45 ohms
Yes
Difference between nominal value of calibration resistance and measured calibration resistance exceeds 45 ohms
Replace control module
MIL on (in 2nd driving cycle)
Internal HW fault in ECU; resets O2 sensor operational standby status Application adjustments pending for E70
0x2C4D
11341
Oxygen sensor before catalytic converter, pump current cable
Oxygen Sensor, Front
Positive Current
Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Closed-loop lambda control active and control deviation > 10% - Voltage at CJ125 at 1.5 V (1.49?.1.51V) - Forced amplitude active
Fault monitoring criterion must remain present over 3 sec.
Engine operation, part load
battery voltage < 11 V oder Ubatt > 16 volts
none
3 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo_w) (1.5 volts = Lambda = 1) Closed-loop control factor (fr2_w)
Yes
Open pump current wire
Check plugs/wiring harness, otherwise replace sensor
MIL on (in 2nd driving cycle)
none
0x2C4E
11342
Oxygen sensor before catalytic converter 2, pump current cable
Oxygen Sensor, Front
Positive Current
Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Closed-loop lambda control active and control deviation > 10% - Voltage at CJ125 at 1.5 V (1.49?.1.51 V) - Forced amplitude active
Fault monitoring criterion must remain present over 3 sec.
Engine operation, part load
battery voltage < 11 V oder Ubatt > 16 volts
none
3 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) (1.5 volts = Lambda = 1) Closed-loop control factor (fr2_w)
Yes
Open pump current wire
Check plugs/wiring harness, otherwise replace sensor
MIL on (in 2nd driving cycle)
none
0x2C4D
11341
Oxygen sensor before catalytic converter, pump current cable
Oxygen Sensor, Front
Positive Current
Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Overrun cutoff present for at least 3 min. - Voltage on CJ125 < 1.7 V - Sensor heated adequately
Fault monitoring criterion must remain present over 2 sec.
Engine running
battery voltage < 11V oder Ubatt > 16 volts
none
2 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo_w) (1.5 volts = Lambda = 1) Overrun cutoff condition (B_sa=1)
Yes
Open pump current wire
Check plugs/wiring harness, otherwise replace sensor
MIL on (in 2nd driving cycle)
none
0x2C4E
11342
Oxygen sensor before catalytic converter 2, pump current cable
Oxygen Sensor, Front
Positive Current
Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Overrun cutoff present for at least 3 min. - Voltage on CJ125 < 1.7 V - Sensor heated adequately
Fault monitoring criterion must remain present over 2 sec.
Engine running
battery voltage < 11V oder Ubatt > 16 volts
none
2 sec.
none
Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) (1.5 volts = Lambda = 1) Overrun cutoff condition (B_sa=1)
Yes
Open pump current wire
Check plugs/wiring harness, otherwise replace sensor
MIL on (in 2nd driving cycle)
none
0x2C4B
11339
Control module, internal fault: oxygen sensor module
Oxygen Sensor, Front
ECM Self-Test
Communications fault between ECU and CJ125 chip (SPI bus)
Fault monitoring criterion must remain present over 2 sec.
Terminal 15 ON
battery voltage < 11V oder Ubatt > 16 volts
none
2 sec.
none
Internal diagnosis in CJ125 chip
none
Internal fault in control module
Replace control module
MIL on (in 2nd driving cycle)
none
0x2C4C
11340
Control module, internal fault: oxygen sensor module 2
Oxygen Sensor, Front
ECM Self-Test
Communications fault between ECU and CJ125 chip (SPI bus)
Fault monitoring criterion must remain present over 2 sec.
Terminal 15 ON
battery voltage < 11 V oder Ubatt > 16 volts
none
2 sec.
none
Internal diagnosis in CJ125 chip
none
Internal fault in control module
Replace control module
MIL on (in 2nd driving cycle)
none
0x2C4B
11339
Control module, internal fault: oxygen sensor module
Oxygen Sensor, Front
ECM Self-Test
Communications fault between ECU and CJ125 chip (initialization register)
Fault monitoring criterion must remain present over 2 sec.
Terminal 15 ON
battery voltage<11V oder Ubatt > 16 volts
none
2 sec.
none
Internal diagnosis in CJ125 chip
none
Internal fault in control module
Replace control module
MIL on (in 2nd driving cycle)
none
0x2C4C
11340
Control module, internal fault: oxygen sensor module 2
Oxygen Sensor, Front
ECM Self-Test
Communications fault between ECU and CJ125 chip (initialization register)
Fault monitoring criterion must remain present over 2 sec.
Terminal 15 ON
battery voltage < 11 V oder Ubatt > 16 volts
none
2 sec.
none
Internal diagnosis in CJ125 chip
none
Internal fault in control module
Replace control module
MIL on (in 2nd driving cycle)
none
0x2CA0
11424
Oxygen sensor heating before catalytic converter
Oxygen Sensor, Front
Monitoring of sensor ceramic temperature and control signal pulse-duty factor detects reduced heater performance at oxygen sensor before cat. (no defect in heater wiring) Diagnosis conditions: - No overrun cutoff - Exhaust-gas temperature > 400°C - No other O2 sensor faults
40 sec.
40 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Exhaust-gas temp. (model) > 400°C Ceramic temperature < 720°C
Approximately 60 sec. after engine start under test conditions (see commentary)
none
Exhaust-gas temp. (tavso_w) > 400°C Ceramic temperature (tkerlsu_w) < 720°C Control signal pulse-duty factor at heater driver circuit > 97%
Yes
Impossible to control sensor's ceramic temperature to spec. even with maximum control signal pulse-duty factor applied for extended period
Check plug, replace sensor
MIL on (in 2nd driving cycle)
Test conditions: Run through FTP 75 cycle at ambient temperature of approximately 20°C E70 application adjustments pending
0x2CA1
11425
Oxygen sensor heating before catalytic converter 2
Oxygen Sensor, Front
Monitoring of sensor ceramic temperature and control signal pulse-duty factor detects reduced heater performance at oxygen sensor before cat. (no defect in heater wiring) Diagnosis conditions: - No overrun cutoff - Exhaust-gas temperature > 400°C - No other O2 sensor faults
40 sec.
40 sec.
Engine running
battery voltage < 11 V oder Ubatt > 16 volts
Exhaust-gas temp. (model) > 400°C Ceramic temperature < 720°C
Approximately 60 sec. after engine start under test conditions (see commentary)
none
Exhaust-gas temp. (tavso2_w) > 400°C Ceramic temperature (tkerlsu2_w) < 720°C Control signal pulse-duty factor at heater output circuit > 97%
Yes
Impossible to control sensor's ceramic temperature to spec. even with maximum control signal pulse-duty factor applied for extended period
Check plug, replace sensor
MIL on (in 2nd driving cycle)
Test conditions: Run through FTP 75 cycle at ambient temperature of approximately 20°C E70 application adjustments pending
0x2CA0
11424
Oxygen sensor heating before catalytic converter
Oxygen Sensor, Front
Heater Activity
none
none
none
none
none
none
none
none
none
none
none
none
Fault code inactive (data content defined) Application adjustments pending on E70
0x2CA1
11425
Oxygen sensor heating before catalytic converter 2
Oxygen Sensor, Front
Heater Activity
Fault path not active !
none
none
none
none
none
none
none
none
none
none
none
Data content defined Application adjustments still pending for E70
0x2EEC
12012
Temperature sensor cooler outlet, plausibility
Radiator Coolant
Temperature
tka>tmot
10 sec.
Engine running
none
none
none
none
0.1 - 4.9 V
N
Shunt in sensor or through plug-in connection
Replace sensor, replace plug, replace wiring harness
MIL on
Revisions to application still pending for E70
0xCD87
52615
PT-CAN communication fault
Communication
Powertrain
No suspension of bus activity
200 ms
800 ms after Terminal 15
battery voltage >10 V
none
none
none
Internal CAN fault counter has reached warning threshold but is still ready to transmit and receive
Yes
SG continues to transmit at low priority
Continuation of this status is very unlikely - No passive fault should occur => Generally leads to a plausibility fault
MIL (2nd driving cycle)
none
0xCD87
52615
PT-CAN communication fault
Communication
Powertrain
DPRAM defect
none
Terminal 15
none
none
none
none
Internal CAN fault counter has reached warning threshold and designates a hardware fault during initialization
Yes
Hardware (DPRAM) defect
Replace DME
MIL (2nd driving cycle)
none
0xCD87
52615
PT-CAN communication fault
Communication
Powertrain
No suspension of bus activity
10 ms
800 ms after Terminal 15
battery voltage >10 V
none
none
none
Internal CAN fault counter has reached fault limit, no more CAN signals are being received
Yes
SG receives no signals from PT CAN
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness
MIL (2nd driving cycle)
none
0xCD8B
52619
PT CAN bus communication fault
Communication
Local
No suspension of bus activity
200 ms
800 ms after Terminal 15
battery voltage >10 V
none
none
none
Internal CAN fault counter has reached warning threshold but is still ready to transmit and receive
Yes
SG continues to transmit at low priority
Continuation of this status is very unlikely - No passive fault should occur => Generally leads to a plausibility fault
MIL (2nd driving cycle)
none
0xCD8B
52619
PT CAN bus communication fault
Communication
Local
DPRAM defect
none
Terminal 15
none
none
none
none
Internal CAN fault counter has reached warning threshold and designates a hardware fault during initialization
Yes
Hardware (DPRAM) defect
Replace DME
MIL (2nd driving cycle)
none
0xCD97
52631
Message (torque request AFS, B9)
No Info
No Info
No suspension of bus activity
500 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Steering torque demand, B1
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCD97
52631
Message (torque request AFS, B9)
No Info
No Info
No suspension of bus activity
500 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Steering torque demand, B1
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCD8B
52619
PT CAN bus communication fault
Communication
Local
No suspension of bus activity
10 ms
800 ms after Terminal 15
battery voltage >10 V
none
none
none
Internal CAN fault counter has reached fault limit, no more CAN signals are being received
Yes
SG receives no signals from VVT
Check VVT-SG for CAN fault - Measure resistance on bus (local CAN) - Check wiring harness (local CAN)
MIL (2nd driving cycle)
none
0x2DD9
11737
No message from ARS
No Info
No Info
Vehicle with ARS No suspension of bus activity
400 ms
800 ms after Terminal 15
battery voltage >10 V
none
Alive counter fault on message
none
Check alive counter for Status_ARS message
Yes
ECU failure (ARS) - Bus system failure - Defective bus controller (ARS)
Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated
none
No Info
0x2DD9
11737
No message from ARS
No Info
No Info
Vehicle with ARS No suspension of bus activity
360 ms
800 ms after Terminal 15
battery voltage >10 V
none
No message for 40 ms
none
Check whether following CAN messages are present: Status_ARS
Yes
ECU failure (ARS) - Bus system failure - Defective bus controller (ARS)
Check ARS fuse - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated
none
No Info
0x2DD9
11737
No message from ARS
No Info
No Info
Vehicle with ARS No suspension of bus activity
500 ms
800 ms after Terminal 15
battery voltage >10 V
none
none
none
Plausibility check on torque demand from ARS with model figures calculated from lateral acceleration and speed
Yes
ECU failure (ARS) - Bus system failure - Defective bus controller (ARS)
Check DSC + ARS - Measure resistance on bus - Check wiring harness => Replace affected ECU as indicated
none
To avoid FSP entries the limits for the plausibility check are extended during the ARS service test
0x2DD7
11735
No message from DSC
No Info
No Info
No suspension of bus activity
420 ms
800 ms after Terminal 15
battery voltage > 10 V
none
Incorrect checksum in one of the messages
none
Check of checksum in DSC messages
Yes
ECU failure (DSC) - Bus system failure - Defective bus controller (DSC)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
Revisions to application still pending for E70
0x2DD7
11735
No message from DSC
No Info
No Info
No suspension of bus activity
360 ms
800 ms after Terminal 15
battery voltage > 10 V
none
Fault in alive counter for one of the messages
none
Check alive counter for messages
Yes
ECU failure (DSC) - Bus system failure - Defective bus controller (DSC)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
Revisions to application still pending for E70
0x2DDA
11738
No message from CAS
No Info
No Info
No suspension of bus activity
500 ms
800 ms after Terminal 15
battery voltage >10 V
none
Fault in alive counter or checksum for terminal status message for at least 5 messages
none
Check alive counter and terminal status message checksum
Yes
Starting time longer when message fails - Failure in operation => ' 'Engine off ' ' => extended starting time - Bus system failure - Defective bus controller (CAS)
Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated
none
No Info
0x2DDB
11739
No message from IHKA
No Info
No Info
No suspension of bus activity
3 sec.
800 ms after Terminal 15
battery voltage >10 V
none
No message for 2 sec. (2 messages)
none
Check whether following CAN message is present: Heat flow_AC
Y
ECU failure (IHKA) - Bus system failure - Defective bus controller (IHKA) - Backup default response (engine fan on); possible high idle
Check IHKA fuse - Check bus and climate control ECU - Measure resistance on bus - Check wiring harness => Replace ECU as indicated
none
No Info
0x2DCF
11727
No message from instrument cluster
Communication
Instrument Pack
Vehicles with MIL only (such as US) No suspension of bus activity
15 sec.
800 ms after Terminal 15
battery voltage >10 V
none
MIL status variation inside DME / cluster message
none
Determine whether MIL status at cluster and DME are identical
Yes
ECU failure (cluster) - Bus system failure - Defective bus controller (cluster) - Not possible to trigger MIL ON readout
Measure resistance on bus - Check instrument cluster ECU - Check ZGM - Check K-CAN - Check wiring harness => Replace ECU as indicated
US MIL
No Info
0x2DDC
11740
No message from SZL
No Info
No Info
No suspension of bus activity
400 ms
800 ms after Terminal 15
battery voltage >10 V
none
Alive counter fault on message
none
Cruise control operation message alive counter check
Yes
ECU failure (SZL or ZGM) - Bus system failure - Defective bus controller (SZL or ZGM)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
No Info
0x2F77
12151
Ambient-pressure sensor, plausibility
Ambient Pressure Sensor
Pressure
Ambient pressure > 1150 hPa
5 sec.
Terminal 15=TRUE
9 V < U > 16 V
none
none
none
Analog V
N
Defective ambient pressure sensor
Replace DME
MIL on in 2nd DC, US version only
none
0x2F77
12151
Ambient-pressure sensor, plausibility
Ambient Pressure Sensor
Pressure
Ambient pressure > 1150 hPa
5 sec.
Terminal 15=TRUE
9 V < U > 16 V
none
none
none
Analog V
N
Defective ambient pressure sensor
Replace DME
MIL on in 2nd DC, US version only
none
0x2DDC
11740
No message from SZL
No Info
No Info
No suspension of bus activity
1 sec.
800 ms after Terminal 15
battery voltage >10 V
none
No message for 240 ms (2 messages)
none
Check whether following CAN messages are present: Operation_Cruise control
Yes
ECU failure (SZL or ZGM) - Bus system failure - Defective bus controller (SZL or ZGM)
Check SZL-SG - Measure resistance on bus - Check wiring harness => Replace ECU as indicated
none
No Info
0x2DDC
11740
No message from SZL
No Info
No Info
No suspension of bus activity
400 ms (2 messages)
800 ms after Terminal 15
battery voltage >10 V
none
Checksum fault for 640 ms (3 messages)
none
Checksum check on cruise control_operation message
Yes
ECU failure (SZL or ZGM) - Bus system failure - Defective bus controller (SZL or ZGM)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
No Info
0x2ED1
11985
Generator, mechanical
No Info
No Info
Commercial vehicle >350 rpm, No communications fault
25 sec.
Terminal 15 ON, no BSD fault
Voltage in onboard electrical system > 10 V
none
none
none
none
N
Alternator fails to turn; bearing defect, belt slips or ruptures
Check alternator for turning resistance (binding), replace belt
Charge indicator lamp
New fault location ME9.2.3 Sometimes occurs with outside power supply during service
0x2E97
11927
Generator
No Info
No Info
Commercial vehicle >350 rpm, No communications faults at BSD interface
25 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
None
none
N
Alternator physically obstructed - Torn, loose, oil-soaked belt
Check alternator for easy rotation - Check belt
Charge indicator lamp Terminal 61
Can occur during vehicle servicing when external power source is connected, etc.
0x2E97
11927
Generator
No Info
No Info
Commercial vehicle >350 rpm, No communications faults at BSD interface
25 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
None
none
N
Alternator not approved for use in this vehicle installed
Install alternator with approved detail number
none
If detail number is ident to approved number, information through VS to EA
0x2F71
12145
Electronics-box fan, activation
No Info
No Info
Current on Pin 4--19 I > 2.2 A
n> 40 rpm
Terminal 15=TRUE
9.5 V < U < 17.9 V
none
after 800 ms
control_ebl
Low Side control signal
N
Driver circuit has detected short to battery voltage
Check wiring harness, otherwise replace DME
none
none
0x2F71
12145
Electronics-box fan, activation
No Info
No Info
Current on Pin 4--19 I > 2.2 A
n> 40 rpm
Terminal 15=TRUE
9.5 V < U < 17.9 V
none
after 800 ms
control_ebl
Low Side control signal
N
Driver circuit has detected short to ground
Check wiring harness, otherwise replace DME
none
none
0x2F71
12145
Electronics-box fan, activation
No Info
No Info
Current on Pin 4--19 I > 2.2 A
n> 40 rpm
Terminal 15=TRUE
9.5 V < U < 17.9 V
none
after 800 ms
control_ebl
Low Side control signal
N
Driver circuit has detected open wire
Check wiring harness, otherwise replace DME
none
none
0x2F77
12151
Ambient-pressure sensor, plausibility
Ambient Pressure Sensor
Pressure
Ambient pressure > 1150 hPa
5 sec.
Terminal 15=TRUE
9 V < U > 16 V
none
none
none
Analog V
N
Ambient pressure sensor jumps
Replace DME
MIL on in 2nd DC, US version only
none
0x2D70
11632
Control module, internal fault: monitoring of engine functions
ECM Monitoring
Error Response
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Internal fault in computer or internal fault in control modules
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fault is deactivated and cannot be entered
Fault is deactivated and cannot be entered
0x2D70
11632
Control module, internal fault: monitoring of engine functions
ECM Monitoring
Ignition Timing
Torque monitor
none
nmot > 1200 rpm
none
none
none
none
Ignition angle model value is implausible
Yes
Internal fault in computer or internal fault in control modules
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2D70
11632
Control module, internal fault: monitoring of engine functions
ECM Monitoring
Relative Charge
Torque monitor
none
nmot > 1200 rpm
none
none
none
none
Mass airflow model value is implausible relative to fuel injection quantity and lambda
Yes
Internal fault in computer or internal fault in control modules
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2D71
11633
Control module, internal fault: monitoring of input variables
ECM Monitoring
Throttle Valve
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Internal fault in computer or internal fault in control modules
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fault is deactivated and cannot be entered
Fault is deactivated and cannot be entered
0x2D71
11633
Control module, internal fault: monitoring of input variables
ECM Monitoring
Coding
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
Internal fault in computer or internal fault in control modules
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fault is deactivated and cannot be entered
ME9x does not have accelerator pedal code data - > Fault is deactivated and cannot be entered
0x2D71
11633
Control module, internal fault: monitoring of input variables
ECM Monitoring
Injection Time
Torque monitor
4.1 sec.
nmot > 1200 rpm
none
none
none
none
Model value for relative fuel mass
Yes
Internal fault in computer or internal fault in control modules
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2D71
11633
Control module, internal fault: monitoring of input variables
ECM Monitoring
Fuel Correction
Torque monitor
none
nmot > 1200 rpm
none
none
none
none
Model value for mixture correction is implausible
Yes
Internal fault in computer or internal fault in control modules
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2D72
11634
Control module, internal fault: monitoring of hardware
ECM Monitoring
TPU Chip
Torque monitor
none
nmot > 1200 rpm
none
none
none
none
AD converter internal test
Yes
Internal fault in computer or in electronic control modules (check whether all ADC channels have been converted)
If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.
Fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2FC6
12230
Energy-saving mode active
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
0x2FA3
12195
No coding
No Info
No Info
DME on
none
Terminal 15
none
none
none
none
Determine whether tester service code entries have been made
Yes
No code data yet in DME
Enter code data in DME
none
The ECU's code entries can only be reprogrammed in its initial ten hours of operation. The DME is then disabled for redefinitions of code data
0x2F77
12151
Ambient-pressure sensor, plausibility
Ambient Pressure Sensor
Driving Cycle Comparison
Ambient pressure > 1150 hPa
5 sec.
Terminal 15=TRUE
9 V < U > 16 V
none
none
none
Analog V
N
Defective ambient pressure sensor
Replace DME
MIL on in 2nd DC, US version only
none
0x2D78
11640
Air mass flow adjustment
ECM Monitoring
Air Mass Flow
Torque monitor
none
none
none
none
none
none
Internal mass airflow check
Yes
Fault in mass airflow calibration's internal control range monitor
If additional fault codes are stored in the DME, resolve these issues, if the fault still remains as a current problem, check or repair HFM, otherwise replace DME.
Fuel-supply safety shutdown
The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.
0x2B98
11160
Control module, internal fault: RAM backup, plausibility
No Info
No Info
Counters in NVRAM and in RAM backup not identical
none
Terminal 15
none
none
none
deleted
none
N
Power module switched off Terminal 30 too quickly (possibly without warning) (owing to defective battery)
Check CAN network, replace battery as indicated
none
If the two monitoring counters fail to agree following a hardware power failure, all stored fault codes are deleted from the log and the fault DNVRBUP is entered in response to unreliable RAM backup. E70 application adjustments are pending
0x2ED3
11987
Generator, type incorrect
No Info
No Info
Commercial vehicle >350 rpm, No communications fault
25 sec.
Terminal 15 ON, no BSD fault
Voltage in onboard electrical system > 10 V
none
none
none
none
Yes
Alternator not approved for use in this vehicle installed
Install alternator with approved detail number
none
New fault location ME9.2.3 If detail number identical to approved number info through VS to EA
0x2E7C
11900
Bit-serial data interface, signal
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
none
none
Fault class not present
0x2ED0
11984
Generator, plausibility: temperature
No Info
No Info
Diagnosis not active, specific to application
Never, diagnosis not active
Terminal 15 ON, no BSD fault
none
none
none
none
none
Yes
Alternator airflow obstructed. Thermal overload from unfavorable driving profile possible.
Inspect alternator for unobstructed air current.
none
New fault location ME9.2.3
0x2ED2
11986
Generator, regulator incorrect
No Info
No Info
Implausible alternator regulator type
25 sec.
Terminal 15 ON, no BSD fault
none
none
none
none
none
Yes
Installed regulator was not approved for this vehicle/this alternator
Install regulator with approved detail number
none
New fault location ME9.2.3 If detail number identical to approved number info through VS to EA
0x2D72
11634
Control module, internal fault: monitoring of hardware
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
0x2ECE
11982
Generator, plausibility: electric
No Info
No Info
Specified alternator voltage > Application threshold 1 AND battery voltage < Application threshold 2; no electrical, mechanical or overheating faults, no active excitation current
Never, diagnosis not active
Terminal 15 ON
none
none
none
none
none
Yes
B+- Wire: Open or high contact resistance; Alternator defect Battery defect
Repair B+ wire Check alternator, repair as indicated Check battery, repair as indicated
Charge indicator lamp
New fault location ME9.2.3
0x2E6E
11886
not translated
Cylinder Deactivation System
General
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
New fault location ME9.2.3
0x2E6F
11887
not translated
Cylinder Deactivation System
General
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
New fault location ME9.2.3
0x2DCA
11722
No message from EGS
Communication
TCM
EGS vehicle
360 ms
800 ms after Terminal 15
battery voltage > 10 V
none
No message from EGS
none
Check to determine whether following CAN messages are present: EGS torque demand, transmission data
Yes
ECU failure (EGS) - Bus system failure - Defective bus controller (EGS)
Check EGS fuse - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated
US MIL
No Info
0x2DCB
11723
No message from SSG
Communication
TCM
E65: Data content defined E6x with SSG, no suspension of bus activity
400 ms
800 ms after Terminal 15
battery voltage > 10 V
none
none
none
Check to determine whether following CAN messages are present: SSG torque demand, transmission data
Yes
ECU failure (SMG) - Bus system failure - Defective bus controller (SMG)
Check SSG fuse - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated
US MIL
If this fault occurs on the E65 respond by downloading the correct data set. If this fault appears on the E6x without SMG, delete version Fault is not diagnosed after tester suspends bus activity (flash-programming ECU)
0xCDF9
52729
not translated
No Info
No Info
No suspension of bus activity
60 ms
60 ms after Terminal 15
battery voltage > 10 V
none
none
none
CAN message: (Status EMF, 201)
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCDFA
52730
not translated
No Info
No Info
No suspension of bus activity
600 ms
600 ms after Terminal 15
battery voltage > 10 V
none
none
none
CAN message (EMF positioning command, 1A7)
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCDEF
52719
No message (status, trailer, 2E4)
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
Check DME for correct data/program version
none
Diagnosis data content defined, fault can not be entered
0xCDF9
52729
not translated
No Info
No Info
No suspension of bus activity
60 ms
60 ms after Terminal 15
battery voltage >10 V
none
none
none
CAN message: (Status EMF, 201)
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCDFA
52730
not translated
No Info
No Info
No suspension of bus activity
600 ms
600 ms after Terminal 15
battery voltage > 10 V
none
none
none
CAN message (EMF positioning command, 1A7)
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
New fault location ME9.2.3
0x2DCF
11727
No message from instrument cluster
Communication
Instrument Pack
No suspension of bus activity
Separate message debounce: A_Temp_Relative time 4 sec., Milage 40 sec., Stat cluster 0.4 sec.
800 ms after Terminal 15
battery voltage >10 V
none
No message A_Temp_Relative time for 1200 ms or No millage message for 12 sec. or No Stat_Cluster message for 200 ms
none
Check to determine whether following CAN messages are present: A_Temp_Relative time, Mileage, Stat_Cluster
Yes
ECU failure (cluster) - Bus system failure - Defective bus controller (cluster)
Measure resistance on bus - Check instrument cluster ECU - Check ZGM - Check K-CAN - Check wiring harness => Replace ECU as indicated
US MIL
No Info
0xCDB7
52663
not translated
Communication
Instrument Pack
No suspension of bus activity
21 sec.
Terminal 15
battery voltage > 10 V
none
none
none
CAN message: OBD sensor diagnosis status, 5E0
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
MIL (2nd driving cycle)
New fault location ME9.2.3
0xCD97
52631
Message (torque request AFS, B9)
No Info
No Info
No suspension of bus activity
500 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Steering torque demand, B1
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCDB3
52659
Message (torque request, steering, B1h)
No Info
No Info
No suspension of bus activity
500 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Steering torque demand, B9
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCD97
52631
Message (torque request AFS, B9)
No Info
No Info
No suspension of bus activity
400 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Steering torque demand, B1
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCDB3
52659
Message (torque request, steering, B1h)
No Info
No Info
No suspension of bus activity
400 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Steering torque demand, B9
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCD9B
52635
Message (vehicle mode, 315)
No Info
No Info
E65 Data content defined E6x with Sport switch No suspension of bus activity
No supplementary debounce
E65 none E6x 800 ms after Terminal 15
battery voltage > 10 V
none
No message for 25.5 sec. (2 messages)
none
Check whether following CAN messages are present: Vehicle mode
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated
none
If this fault is entered in an E60, check DME for correct data version/download correct data version
0xCD9B
52635
Message (vehicle mode, 315)
No Info
No Info
E65 Data content defined E6x with Sport switch No suspension of bus activity
E6x No supplementary debounce
800 ms after Terminal 15
battery voltage > 10 V
none
Checksum fault for 50 sec. (5 messages)
none
Checksum test on vehicle mode message
Yes
ECU failure (SZM) - Bus system failure - Defective bus controller (SZM)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
No Info
0xCDA1
52641
Message (steering wheel angle, C4)
No Info
No Info
No suspension of bus activity
400 ms
800 ms after Terminal 15
battery voltage >10 V
none
No message for 40 ms (2 messages)
none
Check whether following CAN message is present: Steering-wheel angle
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
No Info
0xCDA2
52642
Message (power management, battery voltage, 3B4)
Communication
Powermanagement
E60 Data content defined E65 no suspension of bus activity
E60 none E65 No supplementary debounce
800 ms after Terminal 15
battery voltage >10 V
none
No message for 25 sec. (5 messages)
none
E65: Check whether following CAN message is present: Powermanagement_Battery voltage
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
If this fault is entered in an E60, check DME for correct data version/download correct data version
0xCDA3
52643
Message (power management, charging voltage, 334)
No Info
No Info
E60 Data content defined E65 no suspension of bus activity
E60 none E65 No supplementary debounce
800 ms after Terminal 15
battery voltage >10 V
none
No message for 5 sec. (5 messages)
none
E65: Check whether following CAN message is present: Powermanagement_Charge voltage
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
If this fault is entered in an E60, check DME for correct data version/download correct data version
0xCDA7
52647
Message (status, reverse gear, 3B0)
No Info
No Info
E65 data content defined E6x Manual transmission only
E6x Manual transmission: 4 sec.
800 ms after Terminal 15
battery voltage >10 V
none
No message for 1.2 sec. (1 message)
none
Check whether following CAN message is present: Status_Gear_Reverse
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
If this fault code is entered on an E65 or E6x Aut/SMG, check DME for correct data version/download correct data version
0x2DCF
11727
No message from instrument cluster
Communication
Instrument Pack
No suspension of bus activity
300 ms
800 ms after Terminal 15
battery voltage > 10 V
none
Alive counter fault in 6 consecutive messages (600 ms)
none
Check alive counter for message Stat_Cluster
Yes
ECU failure (cluster) - Bus system failure - Defective bus controller (cluster)
Measure resistance on bus - Check instrument cluster ECU - Check ZGM - Check K-CAN - Check wiring harness => Replace ECU as indicated
US MIL
No Info
0xCDAA
52650
Message (status, crash deactivation, el. fuel pump, 135)
No Info
No Info
E65 data content defined
50 sec.
800 ms after Terminal 15
battery voltage >10 V
none
No message for 12 sec. (1 message)
none
Check whether following CAN message is present: Status_Crash deactivation
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
If this fault is entered in an E60, check DME for correct data version/download correct data version
0x2F11
12049
Radiator blind, top
No Info
No Info
Active cooling flap control must be initialized.
up to 20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
In the SGBD: 'start_systemcheck_glf'
PWM of 5-90%
N
- Wire from DME to active cooling flap control is open. PVE: Interrupt wire from DME to active cooling flap control.
- Check wire from the DME to the active cooling flap control
no external display
New fault location ME9.2.3 No hazard is present provided that the voltage supply to the active cooling flap control is OK. (safety circuit in the active cooling flap control is active: both flaps remain open.)
0x2DDA
11738
No message from CAS
No Info
No Info
No suspension of bus activity
400 ms
800 ms after Terminal 15
battery voltage >10 V
none
No message for 40 ms (4 messages)
none
Check whether following CAN messages are present: Terminal status
Yes
ECU failure (CAS) - Bus system failure - Defective bus controller (CAS)
Check CAS fuse - Measure resistance on bus - Check wiring harness => Replace affected ECU as indicated
none
No Info
0x2ECC
11980
Generator, communication
No Info
No Info
Commercial vehicle >350 rpm, No communications fault
25 sec.
Terminal 15 ON, no BSD fault
Voltage in onboard electrical system > 10 V
none
none
none
none
N
- Alternator (BSD-BUS) not connected
- Open wire (BSD
- Check wire (BSD_BUS) BUS) between connecting alternator and alternator and DME. DME
- Check plug-in connection
- Alternator at alternator. defect
- Replace alternator.
none
New fault location ME9.2.3
No Info
0x2E7C
11900
Bit-serial data interface, signal
No Cell
No Cell
DME active
2 sec.
DME active
none
none
No signal for 2000 ms
none
Check to determine whether communications to a BSD component are possible
Yes
Faults in BSD bus system
Check BSD wire
none
none
0x2EBD
11965
No BSD message from generator
No Info
No Info
E65: Application data content defined E6x: Terminal 15
4 sec.
Terminal 15
none
none
10 component requests repeated 10 times before fault is logged
none
if the components fail to respond to request
Yes
BSD component failure Malfunctions/interference in BSD bus system
Check plug on alternator Inspect BSD wire Replace defective components as indicated
none
Revisions to application still pending for E70
0x2EBE
11966
No BSD message from generator 2
No Info
No Info
Alternator installed (E67 only)
4 sec.
Terminal 15
none
none
10 component requests repeated 10 times before fault is logged
none
if the components fail to respond to request
Yes
BSD component failure Malfunctions/interference in BSD bus system
Check plug on alternator 2 Inspect BSD wire Replace defective components as indicated
none
Revisions to application still pending for E70
0xCDED
52717
No message (request, wheel torque, drivetrain, BF)
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
No Info
0xCDEB
52715
Message (lamp status, 21A)
No Info
No Info
No suspension of bus activity
25 sec.
800 ms after Terminal 15
battery voltage >10 V
none
No message for 6 sec. (1 message)
none
Check whether following CAN message is present: Lamp status
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
No Info
0xCDAC
52652
Message (status, water valve, 3B5)
No Info
No Info
Fault not active in ME922T$UU/ME923
none
none
none
none
none
none
none
none
none
Check DME for correct data/program version
none
Data content defined
0xCDEE
52718
No message (time/date, 2F8)
No Info
No Info
No suspension of bus activity
75 sec.
800 ms after Terminal 15
battery voltage >10 V
none
No message for 18 sec. (1 message)
none
Check whether following CAN message is present: Time/date
Yes
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
No Info
0xCDED
52717
No message (request, wheel torque, drivetrain, BF)
No Info
No Info
Fault not active in ME922T$UU
none
none
none
none
none
none
none
none
none
Check DME for correct data/program version
none
Diagnosis data content defined, fault can not be entered
0xCDB3
52659
Message (torque request, steering, B1h)
No Info
No Info
No suspension of bus activity
500 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Steering torque demand, B9
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCDB3
52659
Message (torque request, steering, B1h)
No Info
No suspension of bus activity
500 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Steering torque demand, B9
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCDB0
52656
Message (display, transmission data)
No suspension of bus activity
200 ms
Terminal 15
battery voltage >10 V
none
none
none
CAN message: Transmission display, 1D2
N
ECU failure - Bus system failure - Defective bus controller
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
none
New fault location ME9.2.3
0xCDED
52717
No message (request, wheel torque, drivetrain, BF)
Fault not active in ME922T$UU
none
none
none
none
none
none
none
none
none
Check DME for correct data/program version
none
Diagnosis data content defined, fault can not be entered
0x2DDD
11741
No message from Valvetronic
Communication
Valvetronic (VVT) Control Module
CAN signals missing (time out)
> 500 ms
DME active
Terminal 87 > 7 V
none
500 ms
none
none
N
Short circuit in CAN wire or open circuit
Check wiring harness and plugs
MIL (2nd driving cycle)
none
0x2DDD
11741
No message from Valvetronic
Communication
Valvetronic (VVT) Control Module
VVT CAN message monitoring - Fault in monitored value
> 500 ms
DME active
Terminal 87 > 7 V
none
500 ms
none
none
N
Short circuit in CAN wire or open circuit
Check wiring harness and plugs
MIL (2nd driving cycle)
none
0x2DCA
11722
No message from EGS
Communication
TCM
EGS vehicle
20 ms
800 ms after Terminal 15
battery voltage >10 V
none
Message present, false checksum in 32 consecutive messages (320 ms)
none
Check on checksum for CAN message EGS torque demand
Yes
ECU failure (EGS) - Bus system failure - Defective bus controller (EGS)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
US MIL
No Info
0x2DCA
11722
No message from EGS
Communication
TCM
EGS vehicle
20 ms
800 ms after Terminal 15
battery voltage > 10 V
none
Message present, alive counter fault in 3 consecutive messages
none
Check on alive counter for CAN message EGS torque demand
Yes
ECU failure (EGS) - Bus system failure - Defective bus controller (EGS)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
US MIL
No Info
0x2DCA
11723
No message from SSG
Communication
TCM
E65: Data content defined E6x with SSG, no suspension of bus activity
200 ms
800 ms after Terminal 15
battery voltage >10 V
none
none
none
Check on CAN messages for Torque demand_SSG, check transmission data for correct checksum/alive counter. Plausibility check on time/quantity of torque demands from SSG
Yes
ECU failure (SMG) - Bus system failure - Defective bus controller (SMG)
Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated
US MIL
This fault cannot occur in E65 Fault is not diagnosed during passive bus state triggered by tester (flash-programming ECU)