Self Diagnosis - Diagnostic Trouble Codes - DTC p1327-u1202 (n62) BMW X5 E70

Testing & Diagnostics ~25028 words

BMW ME9.2.3 (DTC P1327-U1202)

ME9.2.3 ECM applies to N62 engine.

BMW Fault Code (hex)

0x2E69

BMW Fault Code (dez)

11881

BMW Fault Code Description VS-Text

Knock-sensor signal 2

Component

Knock Sensor

Subcomponent

Sensor 2

Monitoring criteria

RPM > 2000 rpm. Load factor > 25

Fault debouncing

< 3 sec.

Terminal conditions

Engine running

Voltage conditions

9 - 15 V

Temperature conditions

T mot > 40°C

Time conditions

none

System test

none

Signal information

Analog 0.1 - 1 V according to n

Calculated value Y/N

N

Possible Fault Causes

Electrical fault, shorted signal, short to ground, open circuit; - sensor not installed correctly, loose bolts - Knock sensor outside approved tolerance range - Crankshaft sensor fault can produce diagnosis fault

Repair procedures (plant/service)

Check plugs and wires, inspect sensor mounting (torque), otherwise replace sensor

MIL illumination/CC message/emergency program

MIL on

Remarks

No Info

0x2E69

11881

Knock-sensor signal 2

Knock Sensor

Sensor 2

RPM > 1600 rpm Load factor > 25

< 3 sec.

Engine running

9 - 15 V

T mot > 40 °C

none

none

Analog 7.5 - 40 V according to n

N

Excess engine noise from mechanical defect - Knock sensor outside approved tolerance range - Poor fuel below specification < RON 91 - KWG fault can produce diagnosis fault

Check engine for mechanical defects, otherwise replace sensor

MIL on

No Info

0x2E6A

11882

Knock-sensor signal 3

Knock Sensor

Sensor 3

RPM > 2000 rpm Load factor > 25

< 3 sec.

Engine running

9 - 15 V

T mot > 40°C

none

none

Analog 0.1 - 1 V according to n

N

Electrical fault, shorted signal, short to ground, open circuit; - sensor not installed correctly, loose bolts - Knock sensor outside approved tolerance range - Crankshaft sensor fault can produce diagnosis fault

Check plugs and wires, inspect sensor mounting (torque), otherwise replace sensor

MIL on

No Info

0x2E6A

11882

Knock-sensor signal 3

Knock Sensor

Sensor 3

RPM > 1600 rpm Load factor > 25

< 3 sec.

Engine running

9 - 15 V

T mot > 40 °C

none

none

Analog 7.5 - 40 V according to n

N

Excess engine noise from mechanical defect - Knock sensor outside approved tolerance range - Poor fuel below specification < RON 91 - KWG fault can produce diagnosis fault

Check engine for mechanical defects, otherwise replace sensor

MIL on

No Info

0x2E69

11881

Knock-sensor signal 2

Knock Sensor

Sensor 2

RPM > 1520 rpm Load factor > 25

< 3 sec.

Engine running

9 - 15 V

T mot > 40 °C

none

none

none

N

Interference with data communications in KR module

Replace DME

MIL on

No Info

0x2B66

11110

Camshaft sensor, master

No Info

No Info

Fault present in all phases

5 camshaft revolutions

Terminal 15=TRUE

none

none

8 camshaft revolutions after engine start

None

Target: Signals E_P_NGWA1, E_P_NGWA2, E_P_NGWE1, E_P_NGWE2 electrically inverse to mechanical reluctor

N

All camshaft sensors fail and error codes have been logged: Defect in power supply to camshaft sensors

Check voltage supply (T87) + and ground connection for sensor, signal wire to DME; check sensor installation; if OK, replace sensor

Engine Fault! Reduced Power

No remaining NWG is available to assume the role of master. At least one NWG is needed to calculate the engine's current position. If the last remaining NWG fails while the engine is running, it remains possible to calculate the engine's position using the KWG. Once the engine is off, it is not possible to restart it.

0x2E72

11890

Control module, internal fault: knock sensor module

ECM Self-Test

Knock Control

RPM > 1520 rpm Load factor > 25

< 10 sec.

Engine running

9 - 15 V

T mot > 40°C

none

none

none

N

Knock chip defective

Replace DME

MIL on

No Info

0x2E72

11890

Control module, internal fault: knock sensor module

ECM Self-Test

Knock Control

RPM > 1520 rpm Load factor > 25

< 10 sec.

Engine running

9 - 15 V

T mot > 40°C

none

none

IkrmetI > 4.5 V

N

Knock chip defective

Replace DME

MIL on

No Info

0x2E6A

11882

Knock-sensor signal 3

Knock Sensor

Sensor 3

RPM > 1520 rpm Load factor > 25

< 3 sec.

Engine running

9 - 15 V

T mot > 40 °C

none

none

none

N

Interference with data communications in KR module

Replace DME

MIL on

No Info

0x2E72

11890

Control module, internal fault: knock sensor module

ECM Self-Test

Knock Control

RPM > 1520 rpm Load factor > 25

< 10 sec.

Engine running

9 - 15 V

T mot > 40°C

none

none

Igot < 0.2 V/msec

N

Knock chip defective

Replace DME

MIL on

No Info

0x2A17

10775

DMTL, system fault

EVAP System

Pump Current

Additional release conditions: < 2400 m. above sea level; idle time > 30s; vehicle speed above 40 km/h > 10 min.; engine start temp. 6.6°C < as ambient temperature

Minimum travel distance between refueling and severe leak suspicion = 200 m. Fuel level validation lag for leak diagnosis distance debounce = 20 sec.

Terminal 15 off/on

10.95 < U (V) < 14.5

> 4°C < 35°C

< 550 sec. once per DC

P1434

analog

N

Internal component fault

Replace DM-TL

MIL ON

Canister loag 3

0x2A17

10775

DMTL, system fault

EVAP System

Pump Current

Additional release conditions: < 2400 m. above sea level; idle time > 30 s; vehicle speed above 40 km/h > 10 min.; engine start temp. 6.6°C < as ambient temperature

Minimum travel distance between refueling and severe leak suspicion = 200 m. Fuel level validation lag for leak diagnosis distance debounce = 20 sec.

Terminal 15 off/on

10.95 < U (V) < 14.5

> 4°C < 35°C

15 sec. once per driving cycle

P1447

analog

N

Internal component fault

Replace DM-TL

MIL ON

15% < FTL <85% ECM on

0x2A17

10775

DMTL, system fault

EVAP System

Pump Current

Additional release conditions: < 2400 m. above sea level; idle time > 30 s; vehicle speed above 40 km/h > 10 min.; engine start temp. 6.6°C < as ambient temperature

Minimum travel distance between refueling and severe leak suspicion = 200 m. Fuel level validation lag for leak diagnosis distance debounce = 20 sec.

Terminal 15 off/on

10.95 < U (V) < 14.5

> 4°C < 35°C

10 sec. monitoring time once per DC

Can be triggered with DMTL system test; P Code 1448

Pump current < 15 mA

N

Internal component fault

Replace DM-TL

MIL ON

Engine start temp. > 2°C

0x2A17

10775

DMTL, system fault

EVAP System

Pump Current

Additional release conditions: < 2400 m. above sea level; idle time > 30 s; vehicle speed above 40 km/h > 10 min.; engine start temp. 6.6°C < as ambient temperature

Minimum travel distance between refueling and severe leak suspicion = 200 m. Fuel level validation lag for leak diagnosis distance debounce = 20 sec.

Terminal 15 off/on

10.95 < U (V) < 14.5

> 2°C < 37°C

10 sec. monitoring time once per DC

Can be triggered with DMTL system test; P Code 1449

> 40 mA

N

Internal component fault

Replace DM-TL

MIL ON

Engine start temp. > 2°C

0x2F11

12049

Radiator blind, top

No Info

No Info

Active cooling flap control must be initialized.

up to 20 sec.

Terminal 15 ON

Voltage in onboard electrical system > 10 V

none

none

In the SGBD: 'start_systemcheck_glf'

PWM of 5-90 %

N

  1. Wire from the DME to the active cooling flap control is shorted to ground.
  2. No voltage supply to the active cooling flap control. PVE: Ground wire from DME to active cooling flap control.
  1. Check whether self-diagnosis fault for active cooling flap control or passive cooling flap control is entered in FS. (If yes, start by repairing this.)
  2. Check wiring from the DME to the active cooling flap control
  3. Check voltage supply to the active cooling flap control

no external display

New fault location ME9.2.3. No hazard is present provided that the voltage supply to the active cooling flap control is OK. (safety circuit in the active cooling flap control is active: both flaps remain open.)

0x2F11

12049

Radiator blind, top

No Info

No Info

Active cooling flap control must be initialized.

up to 20 sec.

Terminal 15 ON

Voltage in onboard electrical system > 10 V

none

none

In the SGBD: 'start_systemcheck_glf'

PWM of 5-90 %

N

  1. Wire from DME to active cooling flap control is shorted to battery voltage. PVE: Connect wire from DME to active cooling flap control to battery voltage.
  1. Check wire from the DME to the active cooling flap control

no external display

New fault location ME9.2.3. No hazard is present provided that the voltage supply to the active cooling flap control is OK. (safety circuit in the active cooling flap control is active: both flaps remain open.)

0x2F10

12048

Radiator blind, bottom

No Info

No Info

  1. Passive cooling flap control must be initialized. Operation of lower flap: 3 x open and 3 x closed. Or conduct the system test

up to 20 sec.

Terminal 15 ON

Voltage in onboard electrical system > 10 V

none

none

In the SGBD: 'start_systemcheck_glf'

PWM of 5-90%

N

  1. Defect in wire from active cooling flap control to passive cooling flap control (all 3 fault classes)
  2. Defect in wire from passive cooling flap control to ground (open wire or short to battery voltage)
  3. Defective retention solenoid (internal short
  1. Check wire from active cooling flap control PIN 4 to passive cooling flap control (+ terminal)
  2. Check ground connection on the passive cooling flap control
  3. Check retainer solenoid (internal short or burned through)

no external display

New fault location ME9.2.3 There is no danger with the passive cooling flap control provided that it does not stop operating in its closed position.

0x2E8B

11915

Intelligent battery sensor, signal

No Info

No Info

IBS: Interference with extended communications on BSD bus

Time

none

none

none

none

N

Monitored data from IBS to DME as serial bus signals through BSD = Synchronous bit data interface. Test possible with 'Uni_Bsd 2001 ' tester from Eyssler.

N

  1. Brief bus fault
  2. Other defective BSD component interferes with BSD bus.
  3. Sporadic short to battery voltage/ground 4. Intermittent contact on BSD wire 5. Defective battery sensor.
  1. Check BSD wire for sporadic shorts to battery voltage and ground
  2. Check for intermittent contacts
  3. Disconnect other BSD components one after the other and replace as indicated
  4. If fault persists after deletion of stored fault codes from log, replace battery sensor
  5. If fault code is logged repeatedly, replace battery sensor

No warning lamp or CC status report

No Info

0x2E8B

11915

Intelligent battery sensor, signal

No Info

No Info

IBS: Interference in data communications on BSD bus

Time

none

none

none

none

N

Serial bus signal

N

  1. BSD wire open
  2. Other defective BSD component interferes with traffic on BSD bus.
  3. Intermittent short to battery voltage or ground
  4. Defective battery sensor.
  1. Check BSD wire for shorts to battery voltage and ground
  2. Check for open wires
  3. Disconnect other BSD components one after the other and replace as indicated
  4. If fault persists after deletion of stored fault codes from log, replace battery sensor
  5. If fault code is logged repeatedly, replace battery sensor

No warning lamp or CC status report

No Info

0x2EB8

11960

No BSD message from intelligent battery sensor

No Info

No Info

E65: Application data content defined E6x: Terminal 15

4 sec.

Terminal 15

none

none

10 component requests repeated 10 times before fault is logged

none

if the components fail to respond to request

Yes

BSD component failure. Malfunctions/interference in BSD bus system

Check IBS plug Check BSD wire. Replace defective components as indicated.

none

Revisions to application still pending for E70

0x2EBA

11962

not translated

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

none

none

Fault not active in ME922T$UU/ME92 3

0x2EBB

11963

not translated

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

none

none

Fault not active in ME922T$UU/ME92 3

0x2E8B

11915

Intelligent battery sensor, signal

No Info

No Info

IBS: Implausible SW version

Time

none

none

none

none

N

Serial bus signal

N

Installed sensor incompatible or too old

Install sensor with current part number

No warning lamp or CC status report

No Info

0x2E8C

11916

Intelligent battery sensor, signal transmission

No Info

No Info

Implausible battery temperature measurement

Event-oriented

none

none

none

none

N

Serial bus signal

N

Self-diagnosis has detected potential problem in its temperature measurement

  1. If fault persists after deletion of stored fault codes from log, replace battery sensor
  2. If fault code is entered repeatedly, replace battery sensor

No warning lamp or CC status report

No Info

0x2E8C

11916

Intelligent battery sensor, signal transmission

No Info

No Info

Implausible battery voltage measurement

Event-oriented

none

none

none

none

N

Serial bus signal

N

Self-diagnosis has detected possible problem with its voltage measurement

  1. If fault persists after deletion of stored fault codes from log, replace battery sensor
  2. If fault code is entered repeatedly, replace battery sensor

No warning lamp or CC status report

No Info

0x2E8C

11916

Intelligent battery sensor, signal transmission

No Info

No Info

Implausible battery current measurement

Event-oriented

none

none

none

none

N

Serial bus signal

N

Self-diagnosis has detected possible problem with its battery current measurement

  1. Check electrical system/alternator for overvoltage
  2. If fault remains after deleting stored fault codes from log, replace battery sensor
  3. If fault is logged repeatedly, replace battery sensor

No warning lamp or CC status report

No Info

0x2B70

11120

Variable intake system, activation

DISA (Differentiated Intake Manifold)

Electrical

Short-circuit current on H bridge >= 8 A

n> 40 rpm, tateist_w <= 10%

Terminal 15=TRUE

9 V < U > 16 V

none

none

No info.

PWM control-activation signal

Yes

Wire fallen off, jumper in circuit, overheating, excess current, driver circuit defect (SPI fault)

Check wiring harness, otherwise replace DME

none

none

0x2B70

11120

Variable intake system, activation

DISA (Differentiated Intake Manifold)

Signal

Short-circuit current on H bridge >= 8 A

n> 40 rpm, tateist_w <= 10 %

Terminal 15=TRUE

9 V < U > 16 V

none

none

No info.

PWM control-activation signal

Yes

Short to ground

Check wiring harness, otherwise replace DME

none

none

0x2B70

11120

Variable intake system, activation

DISA (Differentiated Intake Manifold)

Signal

Short-circuit current on H bridge >= 8 A

n> 40 rpm, tateist_w <= 10 %

Terminal 15=TRUE

9 V < U > 16 V

none

none

No info.

PWM control-activation signal

Yes

Short to positive

Check wiring harness, otherwise replace DME

none

none

0x2F80

12160

System time, plausibility

Engine Off Timer, External

Electrical

Implausible instrument cluster and/or power module signal

Time

Terminal 30

DME operating range 6 V - 16 V

DME operating range - 40 V -128°C

Continuous as soon as CAN bus is on

none

+-80s difference between timers

N

The system time (time pulse) is implausible relative to DME's internal counter

E65: Check power module if no other CAN faults are detected E60: Check instrument cluster if no other CAN faults are detected.

MIL

No CC message Revisions to application still pending for E70

0x29DD

10717

Poor road surface detection

No signal

10 sec.

Terminal 15, engine on

none

none

Continuous

none

none

Yes

Possible failure of wheelspeed sensors on drive axle

Check DSC-SG

none

Plausibility check in DSC-SG, fault entry in DSC-SG? Revisions to application still pending for E70

0x29DD

10717

Poor road surface detection

v>4000 km/h

10 sec.

Terminal 15, engine on

none

none

Continuous

none

none

Yes

One transmitted wheelspeed is too high

Check DSC-SG

none

Plausibility check in DSC-SG, fault entry in DSC-SG? Revisions to application still pending for E70

0x2E8D

11917

Intelligent battery sensor, function

No Info

No Info

Terminal 15-wakeup wire shorted to ground

Event-oriented

If terminal 15/wakup is being controlled by IBS and charge state is critical

none

none

none

N

Serial bus signal

N

  1. Terminal 15/wake-up wire shorted to ground
  2. Defective driver circuit in battery sensor
  1. With battery sensor disconnected, check Terminal 15/wake-up wire for shorts to ground
  2. Check for non-approved connection of supplementary electr. equipment to Terminal 15/wake-up wire
  3. If fault code is stored, replace battery sensor

No warning lamp or CC status report

No Info

0x2E8D

11917

Intelligent battery sensor, function

No Info

No Info

Terminal 15-Wakeup wire signal level implausible

Event-oriented

at each Terminal 15 switch, meaning rising or falling

none

none

none

N

Serial bus signal

N

  1. Terminal 15/wake-up wire open
  2. Intermittent open in Terminal 15/wake-up wire
  3. Terminal 15/wake-up wire shorted to ground or battery voltage
  4. Defective driver circuit in battery sensor
  1. Check Terminal 15/wakeup wire for opens and intermittent contacts
  2. With battery sensor removed and Terminal 15 off, check Terminal 15/wakeup wire for short to battery voltage -> Repair wire and/or check Terminal 15, control module wakeup
  3. With battery sensor removed and Terminal 15 on, check Terminal 15/wakeup wire for short to ground
  4. With battery sensor connected and Terminal 15 off, check Terminal 15/wakeup wire for shorts to battery voltage -> Replace battery sensor
  5. With battery sensor connected and Terminal 15 on, check Terminal 15/wakeup wire for shorts to ground -> Replace battery sensor

No warning lamp or CC status report

No Info

0x2E8D

11917

Intelligent battery sensor, function

No Info

No Info

IBS system fault

Event-oriented

none

none

none

none

N

Serial bus signal

N

Self-diagnosis has detected internal control-module fault

Replace battery sensor

No warning lamp or CC status report

No Info

0x2F4E

12110

Vehicle speed, signal

Communication

Vehicle Speed Sensor

none

none

none

none

none

none

none

none

none

none

none

none

Fault code inactive (data content defined) Application adjustments pending on E70

0x2EA0

11936

Oil condition sensor

Engine Oil Quality Sensor

Communication

BSD communications between oil condition sensor/DME

60 sec.

Terminal 15 ON

none

none

none

none

BSD communications

Yes

QLT communications fault

Check BSD wire, voltage supply, and oil level sensor ground for open circuits, if OK replace oil level sensor

none

No oil level measurement possible

0x2EBC

11964

No BSD message from oil condition sensor

Engine Oil Quality Sensor

Communication

E65: Application data content defined E6x: Terminal 15

4 sec.

Terminal 15

none

none

10 component requests repeated 10 times before fault is logged

none

if the components fail to respond to request

Yes

BSD component failure. Malfunctions/interference in BSD bus system.

Check QLT/OZ plug. Check BSD wire. Replace defective components as indicated.

none

Revisions to application still pending for E70

0x2F4F

12111

Vehicle speed, plausibility

Vehicle Speed Sensor

Plausibility

none

none

none

none

none

none

none

none

none

none

none

none

Fault code inactive (data content defined) Application adjustments pending on E70

0x2F4F

12111

Vehicle speed, plausibility

Vehicle Speed Sensor

Plausibility

Engine speed 960 - 2000 rpm. Vehicle speed > 10 km/h. Overrun active.

3 sec.

Engine on

9 - 15 V

none

none

none

none

N

Vehicle speed low relative to reference speed. Possible incorrect DSC signal.

Check DSC

MIL on

Revisions to application still pending for E70

0x2B71

11121

Variable intake system

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU

Fault location is from the N62 with infinitely variable-geometry induction system. This fault cannot occur in the N62 T$UU

none

0x2B71

11121

Variable intake system

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU

Fault location is from the N62 with infinitely variable-geometry induction system. This fault cannot occur in the N62 T$UU

none

0x2B71

11121

Variable intake system

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU

Fault location is from the N62 with infinitely variable-geometry induction system. This fault cannot occur in the N62 T$UU

none

0x2B71

11121

Variable intake system

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU

Fault location is from the N62 with infinitely variable-geometry induction system. This fault cannot occur in the N62 T$UU

none

0x2B73

11123

Variable intake system, plausibility

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU

Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU

none

0x2B72

11122

Variable intake system, temperature warning threshold

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault location stems from the N62 with infinitely-adjustable control of induction system. Fault redundant in N62 T$UU.

Fault location stems from the N62 with infinitely-adjustable control of induction system. Fault redundant in N62 T$UU.

none

0x2B73

11123

Variable intake system, plausibility

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU

Fault location stems from the N62 with infinitely-adjustable control of induction system. This fault cannot occur in the N62 T$UU

none

0x2F80

12160

System time, plausibility

Engine Off Timer, External

Electrical

CAN signal failure

Event-oriented

Terminal 30

DME operating range 6 V - 16 V

DME operating range - 40V -128 °C

Continuous as soon as CAN bus is on

none

Failure of CAN signal from power module or instrument cluster

N

CAN bus communications failure

  1. Check CAN bus
  2. Check instrument cluster/power module/CAN signals

MIL

No CC message. Revisions to application still pending for E70.

0x2B82

11138

not translated

Idle Speed Control

Cold Start RPM

Idle speed deviation during catalyst heating (150 rpm below lower limit)

8 sec.

Engine after starting with catalyst heating

none

none

Fault detection to max. 20 sec. after engine start with catalyst heating

none

Engine speed below OK sector by 150 rpm

RPM deviation: Yes

DVE disabled

Replace DVE

none

New fault location ME9.2.3

0x2B82

11138

not translated

Idle Speed Control

Cold Start RPM

Idle speed deviation during catalyst heating (400 rpm above upper limit)

8 sec.

Engine after starting with catalyst heating

none

none

Fault detection to max. 20 sec. after engine start with catalyst heating

none

RPM above OK sector by more than 400 rpm

RPM deviation: Yes

DVE disabled, vacuum leak in connection with LR adaptation fault

Replace DVE only if no LR adaptation fault has been entered (vacuum leak)

none

New fault location ME9.2.3

0x2F50

12112

No message from instrument cluster

No Info

No Info

No suspension of bus activity, no active DSC intervention, brake pedal not depressed, accelerator not depressed

0.5 sec

800 ms after Terminal 15

battery voltage >10 V

none

none

none

CAN signal for vehicle speed in instrument-cluster speedometer is invalid

Yes

Instrument cluster transmits invalidity signal

Check instrument cluster ECU Check PT-CAN

FGR/ACC is deactivated

FGR/ACC is deactivated Revisions to application still pending for E70

0x2F50

12112

No message from instrument cluster

No Info

No Info

No suspension of bus activity, no active DSC intervention, brake pedal not depressed, accelerator not depressed

0.5 sec

800 ms after Terminal 15

battery voltage >10 V

none

none

none

Speed signal transmitted by instrument cluster (rear wheel, filtered) deviates from DSC speed signal (front wheel) by more than 30 km/h.

Yes

Speed signal transmitted by instrument cluster displays excessive deviation from DSC speed signal. In rare cases this fault can be stored in response to extremely dynamic operation on loose surfaces.

Check instrument cluster ECU. Check DSC-SG. Check PT-CAN. No hardware replacement if frequency of fault is low and test of indicated ECU is OK.

FGR/ACC is deactivated

FGR/ACC is deactivated Revisions to application still pending for E70

0x2EA0

11936

Oil condition sensor

Engine Oil Quality Sensor

Temperature

Oil temperature difference >100° within 1 sec.

none

Terminal 15 ON

none

none

none

none

QLT temperature measurement

Yes

QLT temperature measurement fault

Replace oil level sensor

none

none

0x2EA0

11936

Oil condition sensor

Engine Oil Quality Sensor

Level

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault not active in ME922T$UU/ME923

Fault not active in ME922T$UU/ME923

none

Fault not active in ME922T$UU/ME92 3

0x2EA0

11936

Oil condition sensor

Engine Oil Quality Sensor

Permeability

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Fault not active in ME922T$UU/ME923

Fault not active in ME922T$UU/ME923

none

Fault not active in ME922T$UU/ME92 3

0x2D6E

11630

Control module, internal fault: monitoring of actual torque

ECM Self-Test

Torque Monitoring

Torque monitor

none

Engine running

none

none

none

none

Charge (HFM) implausible relative to calculated torque

Yes

HFM DME

Perform test measurements on wire to HFM, check HFM for contamination/replace, replace DME

Fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2DEC

11756

Power management, battery

Powermanagement

Electrical

Battery deep discharge, battery voltage low, as measured by IBS below 9.5 volts for min. 10 sec.

none

Terminal 30

DME operating range

DME operating range

After starting - IBS communications

N

IBS signal, battery voltage<9,5 Volt

IBS signal -> N

Voltage has been below 9 V for 1 min., in contrast with undervoltage fault this is also detected in vehicles in passive standby state

Check standby current draw, check and recharge battery

No warning lamp or CC status report

Fault deleted in E65 data entry

0x2DEC

11756

Power management, battery

Powermanagement

Electrical

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

none

none

Fault code not active (data loaded)

0x2DEB

11755

Power management, vehicle electrical system

Powermanagement

Electrical

Below battery voltage measured by IBS, below 16 volts for at least 10 sec.

none

Terminal 15 with engine running

DME operating range

DME operating range

No time specified, with engine running

N

IBS signal, battery voltage>16 volts

IBS signal -> N

Alternator voltage >16 V Jump-start with 24-volt battery

Has vehicle been jump-started? Fault counter =1 and fault not currently present, then delete stored fault codes from log. Otherwise check electrical system voltage, if voltage >16 V replace alternator

No warning lamp or CC status report

Fault deleted in E65 data entry

0x2DEB

11755

Power management, vehicle electrical system

Powermanagement

Electrical

Below battery voltage measured by IBS, below 9 volts for at least 10 sec.

none

Terminal 15 with engine running

DME operating range

DME operating range

No time specified, with engine running

N

IBS signal, battery voltage < 9 Volt

IBS signal -> N

Alternator, voltage < 9 V

Check electrical system voltage if < 9 V Stecker, Leitungen Generator pr$uUfen wenn I.O. Generator Tauschen

No warning lamp or CC status report

Fault deleted in E65 data entry

0x2DEB

11755

Power management, vehicle electrical system

Powermanagement

Electrical

Battery voltage measured by IBS above 18 volts or below 8.5 volts exceeded for at least 200 ms

none

Terminal 15 with engine running

DME operating range

DME operating range

No time specified, with engine running

N

IBS signal, 8.5 volts

IBS signal -> N

Battery not correctly connected.

Check threaded connections on battery terminals

CC message ""Check battery terminals""

Fault is activated in E65

0x2DED

11757

Power management, closed-circuit current violation

Powermanagement

Electrical

IBS: Detects higher standby current draw in parked phase

none

Terminal R

DME operating range

DME operating range

After starting - IBS communications

N

Calculated value from IBS

N

Standby current violation: Standby current draw exceeds the tolerated limit. Standby current is calculated only when ISD-BSD communications are not present - vehicle in sleep mode.

Conduct energy diagnosis

CC message 'High battery discharge when parked'

Increased energy consumption when parked/fault resolved by data definitions in E65

0x2DBF

11711

No message from ACC

Communication

ACC

ACC vehicle

100 ms

800 ms after Terminal 15

battery voltage >10 V

none

No new CAN messages for 40 ms, corresponds to 2 messages

none

CAN message torque demand_ACC

Yes

ECU failure (ACC) - Bus system failure - Defective bus controller (ACC)

Check ACC fuse - Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated

none

If this fault occurs when ACC is not installed, the DME has been incorrectly initialized for the ACC version. =>Check versions

0x2D00

11520

Throttle-valve actuator, spring test of closing spring

Throttle Actuator

Spring Test

Fault diagnosed only during throttle valve's adaptation phase

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

Throttle valve angle

Yes

Not possible to move DVE from emergency air position (UMA):; - Plate binding; DVE electrical activation defective

Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE

MIL on in 2nd driving cycle + EPCL

none

0x2D02

11522

Throttle-valve actuator, emergency air point

Throttle Actuator

Adaptation

Check on throttle valve's emergency default position as determined during throttle valve adaptation

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

Throttle valve angle

Yes

Failure to reach emergency air position with DVE switched off.

Replace DVE

MIL on in 2nd driving cycle

The emergency backup angle for the throttle valve calculated from the adapted data is not in sector 1.6 %-18%DK

0x2D00

11520

Throttle-valve actuator, spring test of closing spring

Throttle Actuator

Adaptation

Fault diagnosed only during throttle valve's adaptation phase

none

Terminal 15=TRUE

battery voltage>7 V

none

none

none

Throttle valve angle

Yes

Failure to reach emergency air position from open plate: - Plate binding - Defective return spring - DVE electrical activation defective

Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE

MIL on in 2nd driving cycle + EPCL

none

0x2D04

11524

Throttle-valve actuator, test of lower limit position

Throttle Actuator

Adaptation

No throttle valve adaptation conducted yet, fuel-supply safety shutdown until adaptation is successful

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

Throttle valve adaptation

Yes

Failure to reach lower mechanical travel limit:; - Travel stop contamination, foreign object; defective DVE

Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE

none

none

0x2CF1

11505

Throttle-valve actuator, position monitoring

Throttle Actuator

Position Control

Comparison of throttle valve's actual to its specified angle is greater than 0.2 sec. and less than 0.5 sec greater than a value calculated from rpm and temperature

none

Terminal 15=TRUE

battery voltage>7 V

none

0.2 sec

none

Compare actual with specified throttle valve angle

Yes

Binding, seizure, contamination on DVE - Wiring to servo motor control open - Shorted winding in servo motor

Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE

MIL on in 2nd driving cycle

none

0x2CF0

11504

Throttle-valve actuator, control range

Throttle Actuator

Throttle Stuck

Despite control signal to throttle valve> no position change detected in > 0.6 sec.

none

Terminal 15=TRUE

battery voltage>7 V

none

0.6 sec

none

none

none

Binding, seizure, contamination on DVE - Wiring to servo motor control open - Shorted winding in servo motor

Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE

MIL on in 2nd driving cycle

none

0x2CF0

11504

Throttle-valve actuator, control range

Throttle Actuator

Throttle Stuck

Despite control signal to throttle valve> No position change visible in > 5 sec.

none

Terminal 15=TRUE

battery voltage>7 V

none

5 sec.

none

none

none

Binding, seizure, contamination on DVE - Wiring to servo motor control open - Shorted winding in servo motor

Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE

MIL on in 2nd driving cycle

none

0x2B9D

11165

Control module, internal fault: overvoltage

Voltage Monitoring Control Module

Voltage

DME selftest

none

none

none

none

none

none

none

none

Internal fault in computer or internal fault in control modules

Replace DME

EPCL + various warning lamps from other ECUs, as DME is not transmitting messages to the bus

Even if the fault condition is not currently present the DME should be replaced to ensure safety

0x2B9D

11165

Control module, internal fault: overvoltage

Voltage Monitoring Control Module

Voltage

DME selftest

none

none

none

none

none

none

none

none

Internal fault in computer or internal fault in control modules

Replace DME

EPCL + various warning lamps from other ECUs, as DME is not transmitting messages to the bus

Even if the fault condition is not currently present the DME should be replaced to ensure safety

0x2B9D

11165

Control module, internal fault: overvoltage

Communication

Voltage Monitoring Control Module

DME selftest

none

none

none

none

none

none

none

none

Internal fault in computer or internal fault in control modules

Replace DME

EPCL + various warning lamps from other ECUs, as DME is not transmitting messages to the bus

Even if the fault condition is not currently present the DME should be replaced to ensure safety

0x2D03

11523

Throttle-valve actuator, cancel adaptation due to environmental conditions

No Info

No Info

Environmental conditions for throttle valve adaptation were not present

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

none

none

Adaptation aborted owing to failure to satisfy conditions. Previous adaptation valid. Fault code entry for information only

No action required

none

none

0x2D03

11523

Throttle-valve actuator, cancel adaptation due to environmental conditions

No Info

No Info

Environmental conditions for throttle valve adaptation were not present

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

none

none

Adaptation aborted owing to failure to satisfy conditions. Previous adaptation valid. Fault code entry for information only

No action required

none

none

0x2CFF

11519

Throttle-valve actuator, amplifier calibration

No Info

No Info

Fault diagnosed only during throttle valve's adaptation phase

none

Terminal 15 = TRUE + engine running

battery voltage>7 V

none

none

none

Throttle valve potentiometer 1 amplifier calibration

Yes

Fault during amplifier calibration leads to operation with unamplified signal from potentiometer 1.

Delete stored fault codes from log, delete adaptation data

EPCL

none

0x2D05

11525

Throttle-valve actuator, cancel with UMA re-learning

Throttle Actuator

Adaptation

Fault diagnosed only during throttle valve's adaptation phase

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

Throttle valve adaptation

Yes

Fault during attempt to repeat initialization; failure to reach lower mechanical travel limit:; - Travel stop contamination, foreign object; defective DVE

Visual inspection of throttle valve for contamination/foreign objects; check on Kb-B; otherwise replace DVE

none

none

0x2B99

11161

Control module, internal fault: RAM backup

No Info

No Info

Not possible to read NVRAM

none

Terminal 15

none

none

none

deleted

none

N

Not possible to read from flash memory

Replace DME

none

Not possible to read from ECU flash memory. Probable reason is defective flash chip in ECU.

0x2B99

11161

Control module, internal fault: RAM backup

No Info

No Info

Not possible to write to NVRAM

none

Terminal 15

none

none

none

deleted

none

N

Not possible to write to flash memory

Replace DME

none

Not possible to write to ECU flash memory. Probable reason is defective flash chip in ECU.

0x2F59

12121

Automatic start, start signal

No Info

No Info

E65 only Engine speed > 1200 rpm

none

Terminal 15=TRUE

none

none

5 seconds after end of engine-start phase

None

Target:E_S_START On HIGH during engine starts, otherwise LOW

N

E_S_START input at ECU is present with following rpm => E_S_START shorted to battery voltage; starter engages with engine running; starter relay makes without being triggered

Check E_S_START wire; check starter and starter relay; inspect CAS-SG

No CC

If this fault is entered in an E60, check DME for correct data version/download correct data version

0x2F46

12102

EWS random code saving

No Info

No Info

none

none

Terminal 15

none

none

none

none

none

N

At least 2 failed attempts to read random code memory

Replace DME if fault recurs repeatedly, otherwise ignore.

none

none

0x2F45

12101

Interface EWS-DME

No Info

No Info

Telegram reception

3x (frame or stop bit)

Terminal 15

none

none

none

none

none

N

Defective CAS or major signal interference in the wire

Continue problem diagnosis with CAS

none

none

0x2F45

12101

Interface EWS-DME

No Info

No Info

Starting at T15 ON

none

Terminal 15

none

none

2 sec.

none

none

N

Wiring harness defect, wire D_EWS - Defect in CAS voltage supply - Defective CAS - Defective DME

Check D_EWS wire; measure with oscilloscope to see if digital signal present at DME Trigger CAS with tester, no response from CAS: Continue problem diagnosis with CAS

none

none

0x2F45

12101

Interface EWS-DME

No Info

No Info

Telegram reception

3x (parity bit)

Terminal 15

none

none

none

none

none

N

Parity bit fault (interference)

Continue problem diagnosis with CAS or code or wire from CAS to DME

none

none

0x2F46

12102

EWS random code saving

No Info

No Info

none

none

Terminal 15

none

none

none

none

none

N

At least 2 failed attempts to read random code memory

Replace DME if fault recurs repeatedly, otherwise ignore.

none

none

0x2F46

12102

EWS random code saving

No Info

No Info

none

none

Terminal 15

none

none

none

none

none

N

At lest 2 failed attempts to write WC in memory

Replace DME if fault recurs repeatedly, otherwise ignore.

none

none

0x2F44

12100

EWS preventing manipulation

No Info

No Info

Starting at T15 ON

Four incorrect random code telegrams

Terminal 15

none

none

none

none

none

N

Transmitted random code is outside monitored range:; - CAS receives no rpm signal and suspends WC switching sequence

Conduct start data calibration; start engine, n >2000 rpm for 10 sec.; engine OFF, but Terminal R remains on; restart engine when wait-state phase elapses; if engine fails to start WC in CAS does not proceed with switching sequence: Continue problem diagnosis with CAS

none

none

0x2F44

12100

EWS preventing manipulation

No Info

No Info

Starting at T15 ON

An incorrect start value telegram

Terminal 15

none

none

none

none

none

N

Fault at start value calibration:; - DME does not belong in this vehicle; DME and CAS do not support mutual operation

If DME really belongs to this vehicle, Terminal 15 OFF/ON, repeat start value calibration; => Status feedback after start value calibration has priority over FS

none

none

0x2F44

12100

EWS preventing manipulation

No Info

No Info

Starting at T15 ON

none

Terminal 15

none

none

none

none

none

N

No start value yet programmed.

First, program start value; => Status feedback after start value calibration has priority over FS

none

none

0x2F44

12100

EWS preventing manipulation

No Info

No Info

Starting at T15 ON

none

Terminal 15

none

none

none

none

none

N

Occurs during attempted start value calibration:; - Fault saving STW in the DME

Terminal 15 off/on, repeat start value calibration

none

none

0x2DBF

11711

No message from ACC

No Info

No Info

ACC vehicle

100 ms

800 ms after Terminal 15

battery voltage > 10 V

none

Checksum fault in 4 consecutive messages (80 ms)

none

CAN message torque demand_ACC

Yes

ECU failure (ACC) - Bus system failure - Defective bus controller (ACC)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness. Replace defective ECU as indicated.

none

No Info

0x2DBF

11711

No message from ACC

No Info

No Info

ACC vehicle

100 ms

800 ms after Terminal 15

battery voltage >10 V

none

Alive-counter fault in 6 consecutive messages (120 ms)

none

CAN message torque demand_ACC

Yes

ECU failure (ACC) - Bus system failure - Defective bus controller (ACC)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

No Info

0x2DBF

11711

No message from ACC

No Info

No Info

ACC vehicle

500 ms

800 ms after Terminal 15

battery voltage >10 V

none

ACC fails to retract torque demand although the brakes are applied

none

CAN message torque demand_ACC

Yes

ACC fails to retract torque demand after braking

Check ACC for fault entries => Replace defective ECU as indicated

none

No Info

0x2D70

11632

Control module, internal fault: monitoring of engine functions

Throttle Control Monitor Level 2/3

AD Converter

Torque monitor

none

nmot > 1200 rpm

none

none

none

none

AD converter internal test

N

Internal fault in computer or internal fault in control modules

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2D75

11637

Control module, internal fault: monitoring of engine speed

Throttle Control Monitor Level 2/3

RPM

Torque monitor

none

none

none

none

none

none

RPM sensor internal check

Yes

Fault in rpm plausibility check under current engine operating conditions - Defective RPM sensor - Defective DME

Check whether nmot in the General Test Data test data block is plausible (warm idle at roughly 580 RPM, governor intervention rpm 6500 RPM); if test value is not OK check/repair crankshaft sensor and wiring; if test value is OK and no fault memory entries related to crankshaft/camshaft are stored in fault log: Replace DME

EPCL + fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2D76

11638

Control module, internal fault: monitoring of accelerator pedal module

Throttle Control Monitor Level 2/3

Pedal Position Sensor

Torque monitor

none

none

battery voltage > 7 V

none

none

none

Internal check on accelerator pedal-position sensor voltage

Yes

Fault in accelerator pedal-position sensor plausibility check - Defective DME - Defective PWG

Check ADC test data in test data block. Both values must rise/fall in tandem. Check wiring harness, check data, replace accelerator pedal, check data, replace DME

EPCL + accelerator pedal emergency default mode

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2E73

11891

Control module, internal fault: knock sensor module

ECM

Knock Sensor

RPM > 1520 rpm Load factor > 25

< 10 sec.

Engine running

9 - 15 V

T mot > 40°C

none

none

none

N

Knock chip defective

Replace DME

MIL on

No Info

0x2DD7

11735

No message from DSC

No Info

No Info

No suspension of bus activity

400 ms

800 ms after Terminal 15

battery voltage > 10 V

none

No message for 40 ms

none

Check to determine whether following CAN messages are present: Speed_Wheel, Torque_demand_DSC, Stat_DSC, Speed

Yes

ECU failure (DSC) - Bus system failure - Defective bus controller (DSC)

Check DSC fuse - Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated.

none

Revisions to application still pending for E70

0x2A21

10785

not translated

Fuel Level Sensor

Electrical

No suspension of bus activity

none

Terminal 15

none

none

none

none

Signal fault is already detected in instrument cluster and relayed to the DME

N

No CAN message from instrument cluster (invalidity value)

Check CAN network (ZGM) and instrument cluster. No ZGM on E70, as replaced by JBBF.

none

New fault location ME9.2.3

0x2A21

10785

not translated

Fuel Level Sensor

Electrical

No suspension of bus activity

51 sec.

Terminal 15

none

none

none

none

Signal fault is already detected in instrument cluster and relayed to the DME

N

No CAN message from instrument cluster (invalidity value)

Check CAN network (ZGM) and instrument cluster No ZGM on E70, as replaced by JBBF

none

New fault location ME9.2.3

0x2A21

10785

not translated

Fuel Level Sensor

Electrical

No suspension of bus activity

51 sec.

Terminal 15

none

none

none

none

Signal fault is already detected in instrument cluster and relayed to the DME

N

No CAN message from instrument cluster (invalidity value)

Check CAN network (ZGM) and instrument cluster. No ZGM on E70, as replaced by JBBF.

none

New fault location ME9.2.3

0x2A80

10880

Intake VANOS, activation

Camshaft Position Actuator

Intake

Driver circuit has detected short to ground

500 ms

Terminal 15=TRUE

9.51 < ub < 17, 90

none

none

None

The pulse-duty factor calculated in vse_tv should be issued

N

Bank 1 intake VANOS - Short to ground

VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists

US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.

VANOS intake and exhaust shift to maximum adjustment (offset 60°)

0x2A80

10880

Intake VANOS, activation

Camshaft Position Actuator

Intake

Driver circuit has detected short to battery voltage

500 ms

Terminal 15=TRUE

9.51 < ub < 17, 90

none

none

None

The pulse-duty factor calculated in vse_tv should be issued

N

Bank 1 intake VANOS - Short to battery voltage

VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists.

US: MIL on in 2nd driving cycle ECE: No MIL VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.

VANOS intake and exhaust remains at travel limits (120° offset)

0x2A85

10885

Exhaust VANOS, activation

Camshaft Position Actuator

Exhaust

Driver circuit has detected short to ground

500 ms

Terminal 15=TRUE

9.51 < ub < 17, 90

none

none

None

The pulse-duty factor calculated in vsa_tv should be issued

N

Bank 1 exhaust VANOS - Short to ground

VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists

US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.

VANOS intake and exhaust shift to maximum adjustment (offset 60°)

0x2A85

10885

Exhaust VANOS, activation

Camshaft Position Actuator

Exhaust

Driver circuit has detected short to battery voltage

500 ms

Terminal 15=TRUE

9.51 < ub < 17, 90

none

none

None

The pulse-duty factor calculated in vsa_tv should be issued

N

Bank 1 exhaust VANOS - Short to battery voltage

VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists.

US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.

VANOS intake and exhaust remains at travel limits (120° offset)

0x2A81

10881

Inlet VANOS, activation 2

Camshaft Position Actuator

Intake

Driver circuit has detected short to ground

500 ms

Terminal 15=TRUE

9.51 < ub < 17, 90

none

none

None

The pulse-duty factor calculated in vse2tv should be issued

N

Bank 2 intake VANOS - Short to ground

VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists

US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.

VANOS intake and exhaust shift to maximum adjustment (offset 60°)

0x2A81

10881

Inlet VANOS, activation 2

Camshaft Position Actuator

Intake

Driver circuit has detected short to battery voltage

500 ms

Terminal 15=TRUE

9.51 < ub < 17, 90

none

none

None

The pulse-duty factor calculated in vse2tv should be issued

N

Bank 2 intake VANOS - Short to battery voltage

VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists

US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.

VANOS intake and exhaust remains at travel limits (120° offset)

0x2A86

10886

Exhaust VANOS, activation 2

Camshaft Position Actuator

Exhaust

Driver circuit has detected short to ground

500 ms

Terminal 15=TRUE

9.51 < ub < 17, 90

none

none

None

The pulse-duty factor calculated in vsa2tv should be issued

N

Bank 2 exhaust VANOS - Short to ground

VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists

US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.

VANOS intake and exhaust shift to maximum adjustment (offset 60°)

0x2A86

10886

Exhaust VANOS, activation 2

Camshaft Position Actuator

Exhaust

Driver circuit has detected short to battery voltage

500 ms

Terminal 15=TRUE

9.51 < ub < 17, 90

none

none

None

The pulse-duty factor calculated in vsa2tv should be issued

N

Bank 2 exhaust VANOS - Short to battery voltage

VANOS plug: Check voltage supply (Terminal 87), DME connection, replace VANOS solenoid valve, then replace DME if problem persists.

US: MIL on in 2nd driving cycle ECE: No MIL. VVT emergency default mode (full stroke) active. VANOS emergency default mode (specification: 120°) active.

VANOS intake and exhaust remains at travel limits (120° offset)

0x2C31

11313

Oxygen sensor before catalytic converter, trim control

Fuel System

Post Catalyst

Trim control I segment (precision controller with oxygen sensor behind cat.) below delta lambda threshold < -0.03; mixture (with lambda control) too lean

Fault monitoring criterion must remain present over 1 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Coolant temperature > 75°C; Catalyst temp. > 400°C

With trim control I segment active (part-load) lasts approximately 10 min. before fault code is logged

none

Delta lambda value behind cat. (dlahi_w)

Yes

  1. Oxygen sensor before cat. too rich
  2. Exhaust system leak adjacent to oxygen sensors
  3. Wiring harness defect (high-ohmage shunt current or similar)
  1. Replace LSU
  2. Repair leak in exhaust system
  3. Check wiring harness

MIL on (in 2nd driving cycle)

none

0x2C31

11313

Oxygen sensor before catalytic converter, trim control

Fuel System

Post Catalyst

Trim control I segment (precision controller with O2 sensor behind cat.) exceeds delta lambda threshold > 0.03; mixture (with lambda closed-loop control) too rich

Fault monitoring criterion must remain present over 1 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Coolant temperature > 75°C; Catalyst temp. > 400°C

With trim control I segment active (part-load) lasts approximately 10 min. before fault code is logged

none

Delta lambda value behind cat. (dlahi_w)

Yes

  1. oxygen sensor before cat. too lean
  2. Exhaust system leak adjacent to oxygen sensors
  3. Wiring harness defect (high-ohmage shunt current or similar)
  1. Replace LSU
  2. Repair leak in exhaust system
  3. Check wiring harness

MIL on (in 2nd driving cycle)

none

0x2c32

11314

Oxygen sensor before catalytic converter 2, trim control

Fuel system

Post catalyst

Trim control I segment (precision controller with oxygen sensor behind cat.) below delta lambda threshold < -0.03; mixture (with lambda control) too lean

Fault monitoring criterion must remain present over 1 sec.

Engine running

Battery voltage < 11 V oder ubatt > 16 volts

Coolant temperature > 75°C; catalyst temp. > 400°C

With trim control I segment active (part-load) lasts approximately 10 min. Before fault code is logged.

None

Cat-back delta lambda (dlahi2_w)

Yes

  1. Oxygen sensor before cat. Too rich
  2. Exhaust system leak adjacent to oxygen sensors
  3. Wiring harness defect (high-ohmage shunt current or similar)
  1. Replace LSU
  2. Repair leak in exhaust system
  3. Check wiring harness

Mil on (in 2nd driving cycle)

None

0x2C32

11314

Oxygen sensor before catalytic converter 2, trim control

Fuel System

Post Catalyst

Trim control I segment (precision controller with O2 sensor behind cat.) exceeds delta lambda threshold > 0.03; mixture (with lambda closed-loop control) too rich

Fault monitoring criterion must remain present over 1 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Coolant temperature > 75°C; Catalyst temp. > 400°C

With trim control I segment active (part-load) lasts approximately 10 min. before fault code is logged

none

Cat-back delta lambda (dlahi2_w)

Yes

  1. oxygen sensor before cat. too lean
  2. Exhaust system leak adjacent to oxygen sensors
  3. Wiring harness defect (high-ohmage shunt current or similar)
  1. Replace LSU
  2. Repair leak in exhaust system
  3. Check wiring harness

MIL on (in 2nd driving cycle)

none

0x2CEF

11503

Throttle-valve actuator, activation

Throttle Actuator

Control Motor

Direct fault report from driver circuit chip in the DME

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

none

N

Control signal to throttle valve motor from inside DME

Replace DME

MIL on in 2nd driving cycle + EPCL

none

0x2CEF

11503

Throttle-valve actuator, activation

Throttle Actuator

Control Motor

Direct fault report from driver circuit chip in the DME

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

none

N

Throttle valve motor, excessive current

Check/replace components and wiring

MIL on in 2nd driving cycle + EPCL

none

0x2CEF

11503

Throttle-valve actuator, activation

Throttle Actuator

Control Motor

Direct fault report from driver circuit chip in the DME

none

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

none

N

Throttle valve motor, short circuit between input and output sides

Check/replace components and wiring

MIL on in 2nd driving cycle + EPCL

none

0x2D1A

11546

Accelerator pedal module, pedal-position sensor

Pedal Position Sensor

D Electrical

none

none

none

none

none

none

none

none

none

Fault is logged together with potentiometer fault 1 or 2 --> For problem source see fault code 11547 or 11548

Remove fault 11547 or 11548

none

none

0x2D1B

11547

Accelerator pedal module, pedal-position sensor, signal 1

Pedal Position Sensor

D Electrical

Pedal-position sensor 1 voltage below minimum

0.14 sec

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

Voltage at pedal-position sensor 1

N

Pedal-position sensor 1 voltage below minimum - Wiring to pedal-position sensor - DME

Check whether upwg1_w in test data block ADC test data < 0.566 V ; check wiring harness, replace accelerator pedal, if upwg1_w is still < 0.566V replace DME

EPCL

none

0x2D1B

11547

Accelerator pedal module, pedal-position sensor, signal 1

Pedal Position Sensor

D Electrical

Pedal-position sensor 1 voltage above maximum

0.14 sec

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

Voltage at pedal-position sensor 1

N

Pedal-position sensor 1 voltage above maximum - Wiring to pedal-position sensor - DME

Check whether upwg1_w in test data block ADC test data > 4.805 V ; check wiring harness, replace accelerator pedal, if upwg1_w is still > 4.805 V replace DME

EPCL

none

0x2D1C

11548

Accelerator pedal module, pedal-position sensor, signal 2

Pedal Position Sensor

E Electrical

Pedal-position sensor 2 voltage below maximum

0.14 sec

Terminal 15=TRUE

battery voltage>7 V

none

none

none

Voltage at pedal-position sensor 2

N

Pedal-position sensor 2 voltage below minimum - Wiring to pedal-position sensor - DME

Check whether upwg2_w in test data block ADC test data < 0.21 V; check wiring harness, replace accelerator pedal, if upwg2_w is still < 0.21 V replace DME

EPCL

none

0x2D1C

11548

Accelerator pedal module, pedal-position sensor, signal 2

Pedal Position Sensor

E Electrical

Pedal-position sensor 2 voltage above maximum

0.14 sec

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

Voltage at pedal-position sensor 2

N

Pedal-position sensor 2 voltage above maximum - Wiring to pedal-position sensor - DME

Check whether upwg2_w in test data block. ADC test data > 2.4 V ; check wiring harness, replace accelerator pedal, if upwg2_w is still > 2.4 V replace DME

EPCL

none

0x2D1B

11547

Accelerator pedal module, pedal-position sensor, signal 1

Pedal Position Sensor

D/E Correlation

Implausible relationship between voltages for pedal-position sensors 1 and 2

0.2 sec

Terminal 15=TRUE

battery voltage > 7 V

none

none

none

Voltages for pedal-position sensor 1 and pedal-position sensor 2

N

Compare voltage for pedal-position sensor 1 with twice figure for pedal-position sensor 2

Check ADC test data in test data block. Maximum approved difference is 0.47 V. Check wiring harness, test data, replace accelerator pedal, test data, replace DME

EPCL

none

0x29ED

10733

Fuel mixture adaptation, lower engine speed range

Fuel System

Off Idle

Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too lean. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (Last) > 20% - Mass airflow > 40 kg/h - Temperature conditions met.

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) Multiplicative adaptation factor, lower range (frau_w) Rel. charge (rl_w) Mass airflow (ml_w)

Yes

Mixture too lean (approximately 20% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective

Induction vacuum leak/exhaust air leak (AFR O2 sensor!) Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29EF

10735

Fuel mixture adaptation, sumcheck fault

Fuel System

Off Idle

Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too lean. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (Last) > 20% - Mass airflow > 40 kg/h - Temperature conditions met

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w). Multiplicative adaptation factor, lower range (frau_w) Rel. charge (rl_w) Mass airflow (ml_w)

Yes

Mixture too lean (approximately 20% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective.

Induction vacuum leak/exhaust air leak (AFR O2 sensor!), Low fuel pressure, Check oxygen sensors before cat. Check tank EVAP air discharge (air leak!) Check HFM (contamination, defect)

US MIL on (2nd driving cycle)

Revisions to application still pending for E70

0x29ED

10733

Fuel mixture adaptation, lower engine speed range

Fuel System

Off Idle

Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too rich, Release conditions: - No active tank ventilation - No fault preventing diagnosis is present - Relative charge (load) > 20% - Mass airflow > 40 kg/h - Temperature conditions met

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) Multiplicative adaptation factor, lower range (frau_w) Rel. charge (rl_w) Mass airflow (ml_w)

Yes

Rich mixture (approximately 20% Deviation): Possible causes: - Fuel pressure too high (regulator, return line plugged) - Defective mass airflow meter - Defect in PCV - Oxygen sensors before cat. defective

High fuel pressure, Check positive crankcase ventilation, Check HFM (contamination, defective), Check oxygen sensors before cat.

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29EF

10735

Fuel mixture adaptation, sumcheck fault

Fuel System

Off Idle

Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too rich, Release conditions: - No active tank ventilation - No fault preventing diagnosis is present - Relative charge (load) > 20% - Mass airflow > 40 kg/h - Temperature conditions met

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) Multiplicative adaptation factor, lower range (frau_w) Rel. charge (rl_w) Mass airflow (ml_w)

Y

Rich mixture (approximately 20% Deviation): Possible causes: - Fuel pressure too high (regulator, return line plugged) - Defective mass airflow meter - Defect in PCV - Oxygen sensors before cat. defective

High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.

US MIL on (2nd driving cycle)

Revisions to application still pending for E70

0x29EE

10734

Fuel mixture adaptation 2, lower engine speed range

Fuel System

Off Idle

Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too lean. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (Last) > 20% - Mass airflow > 40 kg/h - Temperature conditions met

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) Multiplicative adaptation value, lower range (frau2_w) Rel. charge (rl_w) Mass airflow (ml_w)

Yes

Mixture too lean (approximately 20% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective

Induction vacuum leak/exhaust air leak (AFR O2 sensor!) - Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29F0

10736

Fuel mixture adaptation 2, sumcheck fault

Fuel System

Off Idle

Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too lean Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (Last) > 20% - Mass airflow > 40 kg/h - Temperature conditions met

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) Multiplicative adaptation value, lower range (frau2_w) Rel. charge (rl_w) Mass airflow (ml_w)

Yes

Mixture too lean (approximately 20% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective

Induction vacuum leak/exhaust air leak (AFR O2 sensor!). Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)

US MIL on (2nd driving cycle)

Revisions to application still pending for E70

0x29EE

10734

Fuel mixture adaptation 2, lower engine speed range

Fuel System

Off Idle

Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too rich. Release conditions: - No active tank ventilation - No fault preventing diagnosis is present - Relative charge (load) > 20% - Mass airflow > 40 kg/h - Temperature conditions met

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) Multiplicative adaptation value, lower range (frau2_w) Rel. charge (rl_w) Mass airflow (ml_w)

Yes

Rich mixture (approximately 20% Deviation): Possible causes: - Fuel pressure too high (regulator, return line plugged) - Defective mass airflow meter - Defect in PCV - Oxygen sensors before cat. defective

High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29F0

10736

Fuel mixture adaptation 2, sumcheck fault

Fuel System

Off Idle

Fuel-supply system monitored with aid of mixture adaptation data; here lower part-load range (multiplicative adaptation), system too rich - Release conditions: - No active tank ventilation - No fault preventing diagnosis is present - Relative charge (load) > 20% - Mass airflow > 40 kg/h - Temperature conditions met

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) Multiplicative adaptation value, lower range (frau2_w) Rel. charge (rl_w) Mass airflow (ml_w)

Yes

Rich mixture (approximately 20% Deviation): Possible causes: - Fuel pressure too high (regulator, return line plugged) - Defective mass airflow meter - Defect in PCV - Oxygen sensors before cat. defective

High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.

US MIL on (2nd driving cycle)

Revisions to application still pending for E70

0x2EEC

12012

Temperature sensor cooler outlet, plausibility

Engine Coolant Temperature Sensor

2 Plausibility

Stuck check

10 sec.

Engine running

none

tmst < 30°C

none

none

0.1 - 4.9 V

N

Defective sensor, thermostat out of tolerance (opens too late)

Replace sensor, thermostat, plug, wiring harness

MIL on

Revisions to application still pending for E70

0x2EEA

12010

Temperature sensor cooler outlet, signal

Engine Coolant Temperature Sensor

2 Electrical

Short to positive, open wire

10 sec.

Terminal 15 ON

none

none

none

N

Radiator discharge temperature sensor voltage > 4.94 V

N

Wire fallen off/open wire/short to battery voltage

Plug/check wiring harness, if OK replace component

MIL on (US only, in 2nd driving cycle)

No Info

0x2EEA

12010

Temperature sensor cooler outlet, signal

Engine Coolant Temperature Sensor

2 Electrical

Short to ground

10 sec.

Terminal 15 ON

none

none

none

N

Radiator discharge temperature sensor voltage < 0.254 V

N

Input voltage too low/short to ground

Plug/check wiring harness, if OK replace component

MIL on (US only, in 2nd driving cycle)

No Info

0x29E7

10727

Fuel mixture adaptation, idling, per time unit

Fuel System

Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too lean - Release conditions: - No active EVAP purge air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions.

Approximately 10 min.

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) Additive adaptation value, per time unit (rkat_w) Mass airflow ml_w

Yes

Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Injector valve out of tolerance - Valvetronic: Valve travel at idle

Induction vacuum leak/exhaust air leak (AFR O2 sensor !) Low fuel pressure Check oxygen sensors before cat. Check tank EVAP air discharge (air leak !) Check HFM (contamination, defect)

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29EF

10735

Fuel mixture adaptation, sumcheck fault

Fuel System

Idle

Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too lean Release conditions: - No active EVAP purge air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C. Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) Additive adaptation value, per time unit (rkat_w) Mass airflow ml_w

Yes

Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Injector valve out of tolerance - Valvetronic: Valve travel at idle

Induction vacuum leak/exhaust air leak (AFR O2 sensor!). Low fuel pressure Check oxygen sensors before cat. Check tank EVAP air discharge (air leak!) Check HFM (contamination, defect)

US MIL on (2nd driving cycle)

Revisions to application still pending for E70

0x29E7

10727

Fuel mixture adaptation, idling, per time unit

Fuel System

Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too rich. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions

Approximately 10 min.

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) Additive adaptation value, per time unit (rkat_w) Mass airflow ml_w

Yes

Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line) - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Fuel injector valve out of tolerance - Valvetronic: Valve travel too low at idle

Check fuel pressure (regulator, return line). Check oxygen sensors before cat. Check tank EVAP purge air discharge (air leak !) Check HFM (contamination, defect)

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29EF

10735

Fuel mixture adaptation, sumcheck fault

Fuel System

Idle

Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too rich Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions.

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) Additive adaptation value, per time unit (rkat_w) Mass airflow ml_w

Yes

Rich mixture (approximately 23 % Deviation): Possible causes: - High fuel pressure (regulator, return line) - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Fuel injector valve out of tolerance - Valvetronic: Valve travel too low at idle

Check fuel pressure (regulator, return line). Check oxygen sensors before cat. Check tank EVAP purge air discharge (air leak !) Check HFM (contamination, defect)

US MIL on (2nd driving cycle)

Revisions to application still pending for E70

0x29E8

10728

Fuel mixture adaptation 2, idling, per time unit

Fuel System

Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too lean Release conditions: - No active EVAP purge air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions

Approximately 10 min.

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) Additive adaptation value, per time unit (rkat2_w) Mass airflow ml_w

Yes

Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Injector valve out of tolerance - Valvetronic: Valve travel at idle

Induction vacuum leak/exhaust air leak (AFR O2 sensor!) - Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29F0

10736

Fuel mixture adaptation 2, sumcheck fault

Fuel System

Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too lean - Release conditions: - No active EVAP purge air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions

Approximately 10 min.

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) Additive adaptation value, per time unit (rkat2_w) Mass airflow ml_w

Yes

Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Injector valve out of tolerance - Valvetronic: Valve travel at idle

Induction vacuum leak/exhaust air leak (AFR O2 sensor!) Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)

US MIL on (2nd driving cycle)

Revisions to application still pending for E70

0x29E8

10728

Fuel mixture adaptation 2, idling, per time unit

Fuel System

Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too rich - Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions

Approximately 10 min.

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) Additive adaptation value, per time unit (rkat2_w) Mass airflow ml_w

Yes

Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line) - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Fuel injector valve out of tolerance - Valvetronic: Valve travel too low at idle

Check fuel pressure (regulator, return line). Check oxygen sensors before cat. Check tank EVAP purge air discharge (air leak!) Check HFM (contamination, defect)

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29F0

10736

Fuel mixture adaptation 2, sumcheck fault

Fuel System

Idle

Fuel-supply system monitored with aid of mixture adaptation data; here idle range (additive adaptation), system too rich. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Mass airflow < 34 kg/h - Compliance with temperature conditions

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) - Additive adaptation value, per time unit (rkat2_w) - Mass airflow ml_w

Yes

Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line) - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective - Fuel injector valve out of tolerance - Valvetronic: Valve travel too low at idle

Check fuel pressure (regulator, return line) - Check oxygen sensors before cat. - Check tank EVAP purge air discharge (air leak!) - Check HFM (contamination, defect)

US MIL on (2nd driving cycle)

Revisions to application still pending for E70

0x29E5

10725

Fuel mixture adaptation, upper engine speed range

Fuel System

Higher Load

Fuel-supply system monitored with aid of mixture adaptation data; here upper part-load range (multiplicative adaptation), system too lean Release conditions: - No active EVAP purge-air discharge - No faults that disable diagnosis are present - Relative charge (load) > 55% - Mass airflow > 250 kg/h - Compliance with temperature conditions

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) - Multiplicative adaptation value, upper range (frao_w) - Rel. charge (rl_w) - Mass airflow ml_w

Yes

Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective

Induction vacuum leak/exhaust air leak (AFR O2 sensor!) - Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29E5

10725

Fuel mixture adaptation, upper engine speed range

Fuel System

Higher Load

Fuel-supply system monitored with aid of mixture adaptation data; here upper part-load range (multiplicative adaptation), system too rich Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (load) > 55% - Mass airflow > 250 kg/h - Compliance with temperature conditions

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr_w) Multiplicative adaptation value, upper range (frao_w) Rel. charge (rl_w) Mass airflow ml_w

Yes

Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line obstructed) - Defective mass airflow meter - Defect in positive crankcase ventilation - Defect in O2 sensors

High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29E6

10726

Fuel mixture adaptation 2, upper engine speed range

Fuel System

Higher Load

Fuel-supply system monitored with aid of mixture adaptation data; here upper part-load range (multiplicative adaptation), system too lean Release conditions: - No active EVAP purge-air discharge - No faults that disable diagnosis are present - Relative charge (load) > 55% - Mass airflow > 250 kg/h - Compliance with temperature conditions

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w). Multiplicative adaptation value, upper range (frao2_w) Rel. charge (rl_w) Mass airflow ml_w

Yes

Mixture too lean (approximately 23% deviation): Possible causes: - Low fuel pressure - Vacuum leak in induction tract - Air leak in exhaust system - Defective mass airflow meter - Defect in positive crankcase ventilation - Oxygen sensors before cat. defective

Induction vacuum leak/exhaust air leak (AFR O2 sensor!) Low fuel pressure - Check oxygen sensors before cat. - Check tank EVAP air discharge (air leak!) - Check HFM (contamination, defect)

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x29E6

10726

Fuel mixture adaptation 2, upper engine speed range

Fuel System

Higher Load

Fuel-supply system monitored with aid of mixture adaptation data; here upper part-load range (multiplicative adaptation), system too rich. Release conditions: - No active EVAP air discharge - No faults that disable diagnosis are present - Relative charge (load) > 55% - Mass airflow > 250 kg/h - Compliance with temperature conditions

Approximately 10 min.

Engine running

battery voltage < 11 volts or battery voltage > 16 volts

Engine temperature (tmot) > 63°C Intake temperature (tans) < 80°C

Approximately 10 - 20 min. (depending on driving profile, period parked, engine and ambient temperature)

none

Lambda control factor (fr2_w) Multiplicative adaptation value, upper range (frao2_w) Rel. charge (rl_w) Mass airflow ml_w

Yes

Rich mixture (approximately 23% Deviation): Possible causes: - High fuel pressure (regulator, return line obstructed) - Defective mass airflow meter - Defect in positive crankcase ventilation - Defect in O2 sensors

High fuel pressure - Check positive crankcase ventilation - Check HFM (contamination, defective) - Check oxygen sensors before cat.

ECE MIL on (2nd cycle)

Revisions to application still pending for E70

0x2C49

11337

Oxygen sensor before catalytic converter, plausibility

Oxygen Sensor, Front

Signal Check

Comparison of oxygen sensor before/behind cat. signals: Sensor before cat. lean and sensor behind cat. rich. Diagnosis conditions: - Active lambda control before cat. - Sensor behind cat. ready for operation and checked - Partial trim control (with sensor behind cat. active) active.

If fault conditions are present, integrate exhaust system mass flow rate until threshold value is reached. Fault criterion: Lambda > 1.1 (lean) and U_Cat-back sensor > 0.75 V (rich)

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Coolant temperature > 75°C

Approximately 50 sec. once sensor before/behind cat. reaches operational standby status

none

Monitored lambda value on sensor before cat.(lamsoni_w). Sensor voltage on sensor behind cat. (ushk_w)

lamsoni_w: J ushk_w: N

  1. LSU response curve shift toward lean side
  2. Exhaust system leak adjacent to oxygen sensor before/behind cat
  3. Wiring harness defect on O2 sensor wires (high-resistance shunt)
  1. LSU-replace O2 sensor
  2. Repair exhaust system leak
  3. Check wiring harness

MIL on (in 2nd driving cycle)

Revisions to application still pending for E70

0x2C49

11337

Oxygen sensor before catalytic converter, plausibility

Oxygen Sensor, Front

Signal Check

Comparison of before cat./behind cat. O2 sensor signals: Sensor before cat. rich and sensor behind cat. lean. Diagnosis conditions: - Active lambda control before cat. - Sensor behind cat. ready for operation and checked - Partial trim control (with sensor behind cat. active) active

If exhaust system mass airflow integration fault conditions are present, until threshold value is reached Fault criterion: Lambda < 0.90 (rich) and U_cat-back sensor < 0.15 V (lean)

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Coolant temperature > 75°C

Approximately 50 sec. once sensor before/behind cat. reaches operational standby status

none

Monitored lambda value on sensor before cat.(lamsoni_w). Sensor voltage on sensor behind cat. (ushk_w).

lamsoni_w: J ushk_w: N

  1. LSU response curve shift toward rich side
  2. Exhaust system leak adjacent to oxygen sensor before/behind cat.
  3. Wiring harness defect on O2 sensor wires (high-resistance shunt)
  1. LSU-replace O2 sensor
  2. Repair exhaust system leak
  3. Check wiring harness

MIL on (in 2nd driving cycle)

Revisions to application still pending for E70

0x2C4A

11338

Oxygen sensor before catalytic converter 2, plausibility

Oxygen Sensor, Front

Signal Check

Comparison of oxygen sensor before/behind cat. signals: Sensor before cat. lean and sensor behind cat. rich. Diagnosis conditions: - Active lambda control before cat. - Sensor behind cat. ready for operation and checked - Partial trim control (with sensor behind cat. active) active.

If exhaust system mass airflow integration fault conditions are present, until threshold value is reached. Fault criterion: Lambda > 1.1 and U_Oxygen sensor behind cat. > 0.75 V

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Coolant temperature > 75°C

Approximately 50 sec. once sensor before/behind cat. reaches operational standby status

none

Monitored lambda value on sensor before cat. (lamsoni2_w). Sensor voltage on sensor behind cat. (ushk2_w)

lamsoni_w: J ushk_w: N

  1. LSU response curve shift toward lean side
  2. Exhaust system leak adjacent to oxygen sensor before/behind cat
  3. Wiring harness defect on O2 sensor wires (high-resistance shunt)
  1. Replace LSU O2 sensor
  2. Repair leak in exhaust system
  3. Check wiring harness

MIL on (in 2nd driving cycle)

Revisions to application still pending for E70

0x2C4A

11338

Oxygen sensor before catalytic converter 2, plausibility

Oxygen Sensor, Front

Signal Check

Comparison of before cat./behind cat. O2 sensor signals: Sensor before cat. rich and sensor behind cat. lean. Diagnosis conditions: - Active lambda control before cat. - Sensor behind cat. ready for operation and checked - Partial trim control (with sensor behind cat. active) active.

If exhaust system mass airflow integration fault conditions are present, until threshold value is reached. Fault criterion: Lambda < 0.90 (rich) and U_cat-back sensor < 0.15 V (lean)

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Coolant temperature > 75°C

Approximately 50 sec. once sensor before/behind cat. reaches operational standby status

none

Monitored lambda value on sensor before cat. (lamsoni2_w). Sensor voltage on sensor behind cat. (ushk2_w)

lamsoni_w: J ushk_w: N

  1. LSU response curve shift toward rich side
  2. Exhaust system leak adjacent to oxygen sensor before/behind cat.
  3. Wiring harness defect on O2 sensor wires (high-resistance shunt)
  1. Replace LSU O2 sensor
  2. Repair leak in exhaust system
  3. Check wiring harness

MIL on (in 2nd driving cycle)

Revisions to application still pending for E70

0x2F78

12152

Control module, internal fault: ambient-pressure sensor

Ambient Pressure Sensor

Electrical

Internal voltage measurement in ambient pressure sensor U > 4.7998

1 sec.

Terminal 15=TRUE

9 V < U > 16 V

none

none

none

Analog V

N

Short to ground

Replace DME

MIL on in 2nd DC, US version only

none

0x2F78

12152

Control module, internal fault: ambient-pressure sensor

Ambient Pressure Sensor

Electrical

Internal voltage measurement in ambient pressure sensor U > 4.7998

1 sec.

Terminal 15=TRUE

9 V < U > 16 V

none

none

none

Analog V

N

Short to battery voltage

Replace DME

MIL on in 2nd DC, US version only

none

0x2C37

11319

Oxygen sensor before catalytic converter, heater coupling

Oxygen Sensor, Front

Heater

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

none

none

Fault code not active (data loaded)

0x2C38

11320

Oxygen sensor before catalytic converter 2, heater coupling

Oxygen Sensor, Front

Heater

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

none

none

Fault code not active (data loaded)

0x2C4D

11341

Oxygen sensor before catalytic converter, pump current cable

Oxygen Sensor, Front

Positive Current

Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Lambda specification outside 3% relative to lambda = 1 - Voltage at CJ125 at 1.5 V (1.49?.1.51 V) - Closed-loop lambda control active.

Fault monitoring criterion must remain present over 2 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

2 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo_w) (1.5 volts = Lambda = 1). Closed-loop control factor (fr2_w)

Yes

Open pump current wire

Check plugs/wiring harness, otherwise replace sensor

MIL on (in 2nd driving cycle)

none

0x2C4E

11342

Oxygen sensor before catalytic converter 2, pump current cable

Oxygen Sensor, Front

Positive Current

Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Lambda specification outside 3% relative to lambda = 1 - Voltage at CJ125 at 1.5 V (1.49?.1.51 V) - Closed-loop lambda control active.

Fault monitoring criterion must remain present over 2 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

2 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) (1.5 volts = Lambda = 1). Closed-loop control factor (fr2_w)

Yes

Open pump current wire

Check plugs/wiring harness, otherwise replace sensor

MIL on (in 2nd driving cycle)

none

0x2C51

11345

Oxygen sensor before catalytic converter, Nernst cable

Oxygen Sensor, Front

Reference Voltage

Monitoring on missing Nernst voltage wire (UN); Diagnosis conditions: - No fault recognized on O2 sensor heater driver circuit - O2 sensor voltage in implausible range (Ua < 0.2 V or > 4.7 V

Fault monitoring criterion must remain present over 1 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

1 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo_w)

Yes

Implausible Nernst cell internal resistance, too high, and UA output signal after deactivation of 3kHz-Ri test frequency either high or low; Nernst wire or virtual ground missing

Check plug/wiring harness/O2 wiring, otherwise replace O2 sensor

MIL on (in 2nd driving cycle)

none

0x2C52

11346

Oxygen sensor before catalytic converter 2, Nernst cable

Oxygen Sensor, Front

Reference Voltage

Monitoring on missing Nernst voltage wire (UN); Diagnosis conditions: - No fault recognized on O2 sensor heater driver circuit - O2 sensor voltage in implausible range (Ua < 0.2 V or > 4.7 V

Fault monitoring criterion must remain present over 1 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

1 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo_w)

Yes

Implausible Nernst cell internal resistance, too high, and UA output signal after deactivation of 3kHz-Ri test frequency either high or low; Nernst wire or virtual ground missing

Check plug / wiring harness / O2 wiring, otherwise replace O2 sensor

MIL on (in 2nd driving cycle)

none

0x2C53

11347

Oxygen sensor before catalytic converter, virtual ground

Oxygen Sensor, Front

Negative Current

Monitoring for disconnected virtual ground wire (VM); Diagnosis conditions: - Overrun cutoff not active - O2 sensor voltage is in 1.5 V range f. open wire - No other faults are present for the LSU O2 sensor - Fault detected through measured high internal resistance (rinlsu2_w>1800 ohms)

Fault monitoring criterion must remain present over 5 sec.

Engine running

battery voltage < 11V oder Ubatt > 16 volts

none

5 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo_w). Internal resistance of LSU from CJ125 (rinlsu_w).

Yes

  1. Open wire on O2 sensor
  2. Open circuit at plug/wiring harness/control module

Check plug/wiring harness/O2 wiring, otherwise replace O2 sensor

MIL on (in 2nd driving cycle)

none

0x2C54

11348

Oxygen sensor before catalytic converter 2, virtual ground

Oxygen Sensor, Front

Negative Current

Monitoring for disconnected virtual ground wire (VM); Diagnosis conditions: - Overrun cutoff not active - O2 sensor voltage is in 1.5 V range f. open wire - No other faults are present for the LSU O2 sensor - Fault detected through measured high internal resistance (rinlsu2_w>1800 ohms)

Fault monitoring criterion must remain present over 5 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

5 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) Internal resistance of LSU from CJ125 (rinlsu2_w)

Yes

  1. Open wire on O2 sensor
  2. Open circuit at plug/wiring harness/control module

Check plug/wiring harness/O2 wiring, otherwise replace O2 sensor

MIL on (in 2nd driving cycle)

none

0x2C6D

11373

Oxygen sensor behind catalytic converter, ageing

Oxygen Sensor, Rear

Signal Check

Cat-back sensor heated to adequate level

Time 120 sec./continuous

Terminal 15 on Engine running

Battery voltage 11V < battery voltage < 16V

none

400 sec. after drive at 80 km/h

Oxygen sensor behind cat. voltage U < 0.65 V

Signal from O2 sensor -> N

Fault in oscillation test: Signal stuck on lean

Replace LSH

MIL on

Vehicle must be moved (80 km/h). Revisions to application still pending for E70.

0x2C6D

11373

Oxygen sensor behind catalytic converter, ageing

Oxygen Sensor, Rear

Signal Check

Cat-back sensor heated to adequate level

Time 120 sec./continuous

Terminal 15 on Engine running

Battery voltage 11 V < battery voltage < 16 V

none

400 sec. after drive at 80 km/h

Oxygen sensor behind cat. voltage U > 0.65 V

Signal from O2 sensor -> N

Fault in oscillation test: Signal stuck on rich

Replace LSH

MIL on

Vehicle must be moved (80 km/h). Revisions to application still pending for E70.

0x2C6E

11374

Oxygen sensor behind catalytic converter 2, ageing

Oxygen Sensor, Rear

Signal Check

Cat-back sensor heated to adequate level

Time 120 sec./continuous

Terminal 15 on Engine running

Battery voltage 11 V < battery voltage < 16 V

none

400 sec. after drive at 80 km/h

Oxygen sensor behind cat. voltage U < 0.65 V

Signal from O2 sensor -> N

Fault in oscillation test: Signal stuck on lean.

Replace LSH

MIL on

Vehicle must be moved (80 km/h) Revisions to application still pending for E70

0x2C6E

11374

Oxygen sensor behind catalytic converter 2, ageing

Oxygen Sensor, Rear

Signal Check

Cat-back sensor heated to adequate level

Time 120 sec./continuous

Terminal 15 on Engine running

Battery voltage 11 V < battery voltage < 16 V

none

400 sec. after drive at 80 km/h

Oxygen sensor behind cat. voltage U > 0.65 V

Signal from O2 sensor -> N

Fault in oscillation test: Signal stuck on rich

Replace LSH

MIL on

Vehicle must be moved (80 km/h). Revisions to application still pending for E70.

0x2A13

10771

DMTL leak diagnosis pump, activation

EVAP System

Pump

Open circuit

none

Terminal 15 ON

9.5 < U (V) < 17

none

standing/continuous

P2400

analog

N

Driver circuit has detected open wire

Check plug/wiring harness, otherwise replace pump motor

MIL on in 2nd DC

OBD I fault

0x2A13

10771

DMTL leak diagnosis pump, activation

EVAP System

Pump

Short to ground

none

Terminal 15 ON

9.5 < U (V) < 17

none

standing/continuous

P2401

analog

N

Driver circuit has detected short to ground

Check plugs/check wiring harness, otherwise replace DM-TL

MIL on in 2nd DC

OBD I fault

0x2A13

10771

DMTL leak diagnosis pump, activation

EVAP System

Pump

Short to positive

none

Terminal 15 ON

9.5 < U (V) < 17

none

standing/continuous

P2402

analog

N

Driver circuit has detected short to battery voltage

Check plugs/check wiring harness, otherwise replace DM-TL

MIL on in 2nd DC

OBD I fault

0x2A18

10776

DMTL, heater: activation

EVAP System

DMTL Heater

Open circuit

none

Terminal 15 off/on

9.5 < U (V) < 17

> 4°C < 35°C

At control-activation system test or start of OBD II diagnosis

P1429

analog

N

Driver circuit has detected open wire

Check wiring harness, otherwise replace DME

MIL ON

N

0x2A18

10776

DMTL, heater: activation

EVAP System

DMTL Heater

Short to ground

none

Terminal 15 off/on

9.5 < U (V) < 17

> 4°C < 35°C

At control-activation system test or start of OBD II diagnosis

P1430

analog

N

Driver circuit has detected short to ground

Check wiring harness, otherwise replace DME

MIL ON

N

0x2A18

10776

DMTL, heater: activation

EVAP System

DMTL Heater

Short to positive

none

Terminal 15 off/on

9.5 < U (V) < 17

> 4°C < 35°C

At control-activation system test or start of OBD II diagnosis

P1431

analog

N

Driver circuit has detected short to battery voltage

Check wiring harness, otherwise replace DME

MIL ON

N

0x2C3B

11323

Oxygen sensor before catalytic converter, not connected

Oxygen Sensor, Front

Exhaust Sample Error

Diagnosis recognizes one O2 sensor connected to wiring harness, but not connected to exhaust system. Diagnosis activation conditions: - Overrun cutoff cannot be active ! - No other O2 sensor faults - Sensor must be adequately heated

Fault monitoring criterion must be present longer than 10 sec. (with tank empty: 610 sec.)

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

Approximately 15--125 sec. after start; with tank empty: 600 sec. longer

none

Voltage. CJ125 chip (ua10mo_w)

Yes

O2 sensor is outside the exhaust system, but still connected to the wiring harness

Install O2 sensor with connected plug in exhaust system

MIL on (in 2nd driving cycle)

Revisions to application still pending for E70

0x2C3C

11324

Oxygen sensor before catalytic converter 2, not connected

Oxygen Sensor, Front

Exhaust Sample Error

Diagnosis recognizes one O2 sensor connected to wiring harness, but not connect to exhaust system. Diagnosis activation conditions: - Overrun cutoff cannot be active! - No other O2 sensor faults - Sensor must be adequately heated

Fault monitoring criterion must be present longer than 10 sec. (with tank empty: 610 sec.)

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

Approximately 15--125 sec. after start; with tank empty: 600 sec. longer

none

Voltage. CJ125 chip (ua10mo2_w)

Yes

O2 sensor is outside the exhaust system, but still connected to the wiring harness

Install O2 sensor with connected plug in exhaust system

MIL on (in 2nd driving cycle)

Revisions to application still pending for E70

0x2A12

10770

DMTL solenoid valve, activation

EVAP System

Switching Valve

Open circuit

none

Terminal 15 ON

9.5 < U (V) < 17

none

standing/continuous

P2418

analog

N

Driver circuit has detected open wire

Check wiring harness, otherwise replace DME

MIL on in 2nd DC

OBD I fault

0x2A12

10770

DMTL solenoid valve, activation

EVAP System

Switching Valve

Short to negative

none

Terminal 15 ON

9.5 < U (V) < 17

none

standing/continuous

P2419

analog

N

Driver circuit has detected short to ground

Check plugs/check wiring harness, otherwise replace DM-TL

MIL on in 2nd DC

OBD I fault

0x2A12

10770

DMTL solenoid valve, activation

EVAP System

Switching Valve

Short to positive

none

Terminal 15 ON

9.5 < U (V) < 17

none

standing/continuous

P2420

analog

N

Driver circuit has detected short to battery voltage

Check plugs/check wiring harness, otherwise replace DM-TL

MIL on in 2nd DC

OBD I fault

0x2F9E

12190

Thermal oil-level sensor

Engine Oil Level Sensor

Electrical

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

none

none

Cannot occur on N62T$UU!

0x2F9E

12190

Thermal oil-level sensor

Engine Oil Level Sensor

Plausibility

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

none

none

Cannot occur on N62T$UU!

0x2F9E

12190

Thermal oil-level sensor

Engine Oil Level

Level

Oil sensor has detected low oil level

Oil level has been measured

Engine running

none

none

none

none

Oil sensor, oil level

Yes

Low engine oil level

Top up engine oil

Oil warning lamp

none

0x2C4F

11343

Oxygen sensor before catalytic converter, calibration cable

Oxygen Sensor, Front

Pumping Current

Monitoring on disconnected calibration wire (IA); Diagnosis conditions: - Trailing-throttle overrun abort present for at least 2 sec. - Voltage at CJ125 > 4.8 V - O2 sensor heated to adequate temperature - Exhaust-gas temp. (model) before cat. < 750°C

Fault monitoring criterion must remain present over 1 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Exhaust-gas temperature (model) < 750°C

1 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo_w) (voltage at air = 4.2 V) Overrun cutoff condition (B_sa=1)

Yes

Calibration wire (wire for sensor calibration resistor in sensor plug) disconnected

Check plug / wiring harness / O2 wiring, otherwise replace O2 sensor

MIL on (in 2nd driving cycle)

none

0x2C50

11344

Oxygen sensor before catalytic converter 2, calibration cable

Oxygen Sensor, Front

Pumping Current

Monitoring on disconnected calibration wire (IA); Diagnosis conditions: - Trailing-throttle overrun abort present for at least 2 sec. - Voltage at CJ125 > 4.8 V - O2 sensor heated to adequate temperature - Exhaust-gas temp. (model) before cat. < 750°C

Fault monitoring criterion must remain present over 1 sec.

Engine running

battery voltage <11 V oder Ubatt > 16 volts

Exhaust-gas temperature (model) < 750°C

1 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) (voltage at air = 4.2 V) Overrun cutoff condition (B_sa=1)

Yes

Calibration wire (wire for sensor calibration resistor in sensor plug) disconnected

Check plug/wiring harness/O2 wiring, otherwise replace O2 sensor

MIL on (in 2nd driving cycle)

none

0x2F0D

12045

Radiator blind, activation, (GLF)

No Info

No Info

Current at Pin 4--31 I > 1.9 A

n> 40 rpm

Terminal 15=TRUE

9.5 V < U < 17.9 V

none

after 500 ms

steuern_glf

Low Side control signal

Yes

Driver circuit has detected short to battery voltage

Check wiring harness, otherwise replace DME

MIL ON in 2nd DC

none

0x2F0D

12045

Radiator blind, activation, (GLF)

No Info

No Info

Current at Pin 4--31 I > 1.9 A

n> 40 rpm

Terminal 15=TRUE

9.5 V < U < 17.9 V

none

after 500 ms

steuern_glf

Low Side control signal

Yes

Driver circuit has detected short to ground

Check wiring harness, otherwise replace DME

MIL ON in 2nd DC

none

0x2F0D

12045

Radiator blind, activation, (GLF)

No Info

No Info

Current at Pin 4--31 I > 1.9 A

n> 40 rpm

Terminal 15=TRUE

9.5 V < U < 17.9 V

none

after 500 ms

steuern_glf

Low Side control signal

Yes

Driver circuit has detected open wire

Check wiring harness, otherwise replace DME

MIL ON in 2nd DC

none

0x2C4B

11339

Control module, internal fault: oxygen sensor module

Oxygen Sensor, Front

ECM Self-Test

Monitor for voltage adaptation value electr. calibration of CJ125 IC Calibration runs after engine start and in idle phases

Fault criterion: Calibration adaptation value > 0.1 volts Fault entry after 10 sec.

Terminal 15 ON

battery voltage<11V oder Ubatt > 16 volts

none

10 sec.

none

Correction value for standard response curve (v=17): kusvk_w Correction value for rich response curve (v=8): kusvkft_w

Y

Offset correction value is above the maximum approved threshold value

  1. Check wiring harness
  2. Replace control module

MIL on (in 2nd driving cycle)

none

0x2C4C

11340

Control module, internal fault: oxygen sensor module 2

Oxygen Sensor, Front

ECM Self-Test

Monitor for voltage adaptation value electr. calibration of CJ125 IC Calibration runs after engine start and in idle phases

Fault criterion: Calibration adaptation value > 0.1 volts Fault entry after 10 sec.

Terminal 15 ON

battery voltage<11V oder Ubatt > 16 volts

none

10 sec.

none

Correction figure of standard response curve (v=17): kusvk2_w Correction figure for rich response curve (v=8): kusvkft2_w

Yes

Offset correction value is above the maximum approved threshold value

  1. Check wiring harness
  2. Replace control module

MIL on (in 2nd driving cycle)

none

0x2C4B

11339

Control module, internal fault: oxygen sensor module

Oxygen Sensor, Front

ECM Self-Test

Monitor for CJ125 chip power supply; voltage too low

Fault monitoring criterion must remain present over 2 sec.

Terminal 15 ON

battery voltage < 11V oder Ubatt > 16 volts

none

2 sec.

none

Internal diagnosis in CJ125 chip

none

Internal HW fault in control module

Replace control module

MIL on (in 2nd driving cycle)

none

0x2C4C

11340

Control module, internal fault: oxygen sensor module 2

Oxygen Sensor, Front

ECM Self-Test

Monitor for CJ125 chip power supply; voltage too low

Fault monitoring criterion must remain present over 2 sec.

Terminal 15 ON

battery voltage < 11 V oder Ubatt > 16 volts

10 sec./continuous

2 sec.

none

Internal diagnosis in CJ125 chip

none

none

Replace control module

MIL on (in 2nd driving cycle)

none

0x2CA0

11424

Oxygen sensor heating before catalytic converter

Oxygen Sensor, Front

ECM Self-Test

Calibration resistance in CJ 125 chip monitored for LSU heater control (Specified calibration resistance in control module: 300 ohms) Fault status recognized when adapted correction value (krivk_w) > 45 ohms

25 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

Diagnosis begins at start if 11 V < battery voltage < 16 V

none

Adapted correction value (krivk_w) > 45 ohms

Yes

Difference between nominal value of calibration resistance and measured calibration resistance exceeds 45 ohms

Replace control module

MIL on (in 2nd driving cycle)

Internal HW fault in ECU; resets O2 sensor operational standby status Application adjustments pending for E70

0x2CA1

11425

Oxygen sensor heating before catalytic converter 2

Oxygen Sensor, Front

ECM Self-Test

Calibration resistance in CJ 125 chip monitored for LSU heater control (Specified calibration resistance in control module: 300 ohms) Fault status recognized when adapted correction value (krivk_w) > 45 ohms

25 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

none

Diagnosis begins at start if 11 V < battery voltage < 16 V

none

Adaptive correction value (krivk2_w) > 45 ohms

Yes

Difference between nominal value of calibration resistance and measured calibration resistance exceeds 45 ohms

Replace control module

MIL on (in 2nd driving cycle)

Internal HW fault in ECU; resets O2 sensor operational standby status Application adjustments pending for E70

0x2C4D

11341

Oxygen sensor before catalytic converter, pump current cable

Oxygen Sensor, Front

Positive Current

Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Closed-loop lambda control active and control deviation > 10% - Voltage at CJ125 at 1.5 V (1.49?.1.51V) - Forced amplitude active

Fault monitoring criterion must remain present over 3 sec.

Engine operation, part load

battery voltage < 11 V oder Ubatt > 16 volts

none

3 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo_w) (1.5 volts = Lambda = 1) Closed-loop control factor (fr2_w)

Yes

Open pump current wire

Check plugs/wiring harness, otherwise replace sensor

MIL on (in 2nd driving cycle)

none

0x2C4E

11342

Oxygen sensor before catalytic converter 2, pump current cable

Oxygen Sensor, Front

Positive Current

Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Closed-loop lambda control active and control deviation > 10% - Voltage at CJ125 at 1.5 V (1.49?.1.51 V) - Forced amplitude active

Fault monitoring criterion must remain present over 3 sec.

Engine operation, part load

battery voltage < 11 V oder Ubatt > 16 volts

none

3 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) (1.5 volts = Lambda = 1) Closed-loop control factor (fr2_w)

Yes

Open pump current wire

Check plugs/wiring harness, otherwise replace sensor

MIL on (in 2nd driving cycle)

none

0x2C4D

11341

Oxygen sensor before catalytic converter, pump current cable

Oxygen Sensor, Front

Positive Current

Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Overrun cutoff present for at least 3 min. - Voltage on CJ125 < 1.7 V - Sensor heated adequately

Fault monitoring criterion must remain present over 2 sec.

Engine running

battery voltage < 11V oder Ubatt > 16 volts

none

2 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo_w) (1.5 volts = Lambda = 1) Overrun cutoff condition (B_sa=1)

Yes

Open pump current wire

Check plugs/wiring harness, otherwise replace sensor

MIL on (in 2nd driving cycle)

none

0x2C4E

11342

Oxygen sensor before catalytic converter 2, pump current cable

Oxygen Sensor, Front

Positive Current

Monitoring on disconnected pump current wire (IP); Diagnosis conditions: - Overrun cutoff present for at least 3 min. - Voltage on CJ125 < 1.7 V - Sensor heated adequately

Fault monitoring criterion must remain present over 2 sec.

Engine running

battery voltage < 11V oder Ubatt > 16 volts

none

2 sec.

none

Sensor voltage proportional to O2 in CJ125 (ua10mo2_w) (1.5 volts = Lambda = 1) Overrun cutoff condition (B_sa=1)

Yes

Open pump current wire

Check plugs/wiring harness, otherwise replace sensor

MIL on (in 2nd driving cycle)

none

0x2C4B

11339

Control module, internal fault: oxygen sensor module

Oxygen Sensor, Front

ECM Self-Test

Communications fault between ECU and CJ125 chip (SPI bus)

Fault monitoring criterion must remain present over 2 sec.

Terminal 15 ON

battery voltage < 11V oder Ubatt > 16 volts

none

2 sec.

none

Internal diagnosis in CJ125 chip

none

Internal fault in control module

Replace control module

MIL on (in 2nd driving cycle)

none

0x2C4C

11340

Control module, internal fault: oxygen sensor module 2

Oxygen Sensor, Front

ECM Self-Test

Communications fault between ECU and CJ125 chip (SPI bus)

Fault monitoring criterion must remain present over 2 sec.

Terminal 15 ON

battery voltage < 11 V oder Ubatt > 16 volts

none

2 sec.

none

Internal diagnosis in CJ125 chip

none

Internal fault in control module

Replace control module

MIL on (in 2nd driving cycle)

none

0x2C4B

11339

Control module, internal fault: oxygen sensor module

Oxygen Sensor, Front

ECM Self-Test

Communications fault between ECU and CJ125 chip (initialization register)

Fault monitoring criterion must remain present over 2 sec.

Terminal 15 ON

battery voltage<11V oder Ubatt > 16 volts

none

2 sec.

none

Internal diagnosis in CJ125 chip

none

Internal fault in control module

Replace control module

MIL on (in 2nd driving cycle)

none

0x2C4C

11340

Control module, internal fault: oxygen sensor module 2

Oxygen Sensor, Front

ECM Self-Test

Communications fault between ECU and CJ125 chip (initialization register)

Fault monitoring criterion must remain present over 2 sec.

Terminal 15 ON

battery voltage < 11 V oder Ubatt > 16 volts

none

2 sec.

none

Internal diagnosis in CJ125 chip

none

Internal fault in control module

Replace control module

MIL on (in 2nd driving cycle)

none

0x2CA0

11424

Oxygen sensor heating before catalytic converter

Oxygen Sensor, Front

Monitoring of sensor ceramic temperature and control signal pulse-duty factor detects reduced heater performance at oxygen sensor before cat. (no defect in heater wiring) Diagnosis conditions: - No overrun cutoff - Exhaust-gas temperature > 400°C - No other O2 sensor faults

40 sec.

40 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Exhaust-gas temp. (model) > 400°C Ceramic temperature < 720°C

Approximately 60 sec. after engine start under test conditions (see commentary)

none

Exhaust-gas temp. (tavso_w) > 400°C Ceramic temperature (tkerlsu_w) < 720°C Control signal pulse-duty factor at heater driver circuit > 97%

Yes

Impossible to control sensor's ceramic temperature to spec. even with maximum control signal pulse-duty factor applied for extended period

Check plug, replace sensor

MIL on (in 2nd driving cycle)

Test conditions: Run through FTP 75 cycle at ambient temperature of approximately 20°C E70 application adjustments pending

0x2CA1

11425

Oxygen sensor heating before catalytic converter 2

Oxygen Sensor, Front

Monitoring of sensor ceramic temperature and control signal pulse-duty factor detects reduced heater performance at oxygen sensor before cat. (no defect in heater wiring) Diagnosis conditions: - No overrun cutoff - Exhaust-gas temperature > 400°C - No other O2 sensor faults

40 sec.

40 sec.

Engine running

battery voltage < 11 V oder Ubatt > 16 volts

Exhaust-gas temp. (model) > 400°C Ceramic temperature < 720°C

Approximately 60 sec. after engine start under test conditions (see commentary)

none

Exhaust-gas temp. (tavso2_w) > 400°C Ceramic temperature (tkerlsu2_w) < 720°C Control signal pulse-duty factor at heater output circuit > 97%

Yes

Impossible to control sensor's ceramic temperature to spec. even with maximum control signal pulse-duty factor applied for extended period

Check plug, replace sensor

MIL on (in 2nd driving cycle)

Test conditions: Run through FTP 75 cycle at ambient temperature of approximately 20°C E70 application adjustments pending

0x2CA0

11424

Oxygen sensor heating before catalytic converter

Oxygen Sensor, Front

Heater Activity

none

none

none

none

none

none

none

none

none

none

none

none

Fault code inactive (data content defined) Application adjustments pending on E70

0x2CA1

11425

Oxygen sensor heating before catalytic converter 2

Oxygen Sensor, Front

Heater Activity

Fault path not active !

none

none

none

none

none

none

none

none

none

none

none

Data content defined Application adjustments still pending for E70

0x2EEC

12012

Temperature sensor cooler outlet, plausibility

Radiator Coolant

Temperature

tka>tmot

10 sec.

Engine running

none

none

none

none

0.1 - 4.9 V

N

Shunt in sensor or through plug-in connection

Replace sensor, replace plug, replace wiring harness

MIL on

Revisions to application still pending for E70

0xCD87

52615

PT-CAN communication fault

Communication

Powertrain

No suspension of bus activity

200 ms

800 ms after Terminal 15

battery voltage >10 V

none

none

none

Internal CAN fault counter has reached warning threshold but is still ready to transmit and receive

Yes

SG continues to transmit at low priority

Continuation of this status is very unlikely - No passive fault should occur => Generally leads to a plausibility fault

MIL (2nd driving cycle)

none

0xCD87

52615

PT-CAN communication fault

Communication

Powertrain

DPRAM defect

none

Terminal 15

none

none

none

none

Internal CAN fault counter has reached warning threshold and designates a hardware fault during initialization

Yes

Hardware (DPRAM) defect

Replace DME

MIL (2nd driving cycle)

none

0xCD87

52615

PT-CAN communication fault

Communication

Powertrain

No suspension of bus activity

10 ms

800 ms after Terminal 15

battery voltage >10 V

none

none

none

Internal CAN fault counter has reached fault limit, no more CAN signals are being received

Yes

SG receives no signals from PT CAN

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness

MIL (2nd driving cycle)

none

0xCD8B

52619

PT CAN bus communication fault

Communication

Local

No suspension of bus activity

200 ms

800 ms after Terminal 15

battery voltage >10 V

none

none

none

Internal CAN fault counter has reached warning threshold but is still ready to transmit and receive

Yes

SG continues to transmit at low priority

Continuation of this status is very unlikely - No passive fault should occur => Generally leads to a plausibility fault

MIL (2nd driving cycle)

none

0xCD8B

52619

PT CAN bus communication fault

Communication

Local

DPRAM defect

none

Terminal 15

none

none

none

none

Internal CAN fault counter has reached warning threshold and designates a hardware fault during initialization

Yes

Hardware (DPRAM) defect

Replace DME

MIL (2nd driving cycle)

none

0xCD97

52631

Message (torque request AFS, B9)

No Info

No Info

No suspension of bus activity

500 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Steering torque demand, B1

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCD97

52631

Message (torque request AFS, B9)

No Info

No Info

No suspension of bus activity

500 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Steering torque demand, B1

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCD8B

52619

PT CAN bus communication fault

Communication

Local

No suspension of bus activity

10 ms

800 ms after Terminal 15

battery voltage >10 V

none

none

none

Internal CAN fault counter has reached fault limit, no more CAN signals are being received

Yes

SG receives no signals from VVT

Check VVT-SG for CAN fault - Measure resistance on bus (local CAN) - Check wiring harness (local CAN)

MIL (2nd driving cycle)

none

0x2DD9

11737

No message from ARS

No Info

No Info

Vehicle with ARS No suspension of bus activity

400 ms

800 ms after Terminal 15

battery voltage >10 V

none

Alive counter fault on message

none

Check alive counter for Status_ARS message

Yes

ECU failure (ARS) - Bus system failure - Defective bus controller (ARS)

Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated

none

No Info

0x2DD9

11737

No message from ARS

No Info

No Info

Vehicle with ARS No suspension of bus activity

360 ms

800 ms after Terminal 15

battery voltage >10 V

none

No message for 40 ms

none

Check whether following CAN messages are present: Status_ARS

Yes

ECU failure (ARS) - Bus system failure - Defective bus controller (ARS)

Check ARS fuse - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated

none

No Info

0x2DD9

11737

No message from ARS

No Info

No Info

Vehicle with ARS No suspension of bus activity

500 ms

800 ms after Terminal 15

battery voltage >10 V

none

none

none

Plausibility check on torque demand from ARS with model figures calculated from lateral acceleration and speed

Yes

ECU failure (ARS) - Bus system failure - Defective bus controller (ARS)

Check DSC + ARS - Measure resistance on bus - Check wiring harness => Replace affected ECU as indicated

none

To avoid FSP entries the limits for the plausibility check are extended during the ARS service test

0x2DD7

11735

No message from DSC

No Info

No Info

No suspension of bus activity

420 ms

800 ms after Terminal 15

battery voltage > 10 V

none

Incorrect checksum in one of the messages

none

Check of checksum in DSC messages

Yes

ECU failure (DSC) - Bus system failure - Defective bus controller (DSC)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

Revisions to application still pending for E70

0x2DD7

11735

No message from DSC

No Info

No Info

No suspension of bus activity

360 ms

800 ms after Terminal 15

battery voltage > 10 V

none

Fault in alive counter for one of the messages

none

Check alive counter for messages

Yes

ECU failure (DSC) - Bus system failure - Defective bus controller (DSC)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

Revisions to application still pending for E70

0x2DDA

11738

No message from CAS

No Info

No Info

No suspension of bus activity

500 ms

800 ms after Terminal 15

battery voltage >10 V

none

Fault in alive counter or checksum for terminal status message for at least 5 messages

none

Check alive counter and terminal status message checksum

Yes

Starting time longer when message fails - Failure in operation => ' 'Engine off ' ' => extended starting time - Bus system failure - Defective bus controller (CAS)

Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated

none

No Info

0x2DDB

11739

No message from IHKA

No Info

No Info

No suspension of bus activity

3 sec.

800 ms after Terminal 15

battery voltage >10 V

none

No message for 2 sec. (2 messages)

none

Check whether following CAN message is present: Heat flow_AC

Y

ECU failure (IHKA) - Bus system failure - Defective bus controller (IHKA) - Backup default response (engine fan on); possible high idle

Check IHKA fuse - Check bus and climate control ECU - Measure resistance on bus - Check wiring harness => Replace ECU as indicated

none

No Info

0x2DCF

11727

No message from instrument cluster

Communication

Instrument Pack

Vehicles with MIL only (such as US) No suspension of bus activity

15 sec.

800 ms after Terminal 15

battery voltage >10 V

none

MIL status variation inside DME / cluster message

none

Determine whether MIL status at cluster and DME are identical

Yes

ECU failure (cluster) - Bus system failure - Defective bus controller (cluster) - Not possible to trigger MIL ON readout

Measure resistance on bus - Check instrument cluster ECU - Check ZGM - Check K-CAN - Check wiring harness => Replace ECU as indicated

US MIL

No Info

0x2DDC

11740

No message from SZL

No Info

No Info

No suspension of bus activity

400 ms

800 ms after Terminal 15

battery voltage >10 V

none

Alive counter fault on message

none

Cruise control operation message alive counter check

Yes

ECU failure (SZL or ZGM) - Bus system failure - Defective bus controller (SZL or ZGM)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

No Info

0x2F77

12151

Ambient-pressure sensor, plausibility

Ambient Pressure Sensor

Pressure

Ambient pressure > 1150 hPa

5 sec.

Terminal 15=TRUE

9 V < U > 16 V

none

none

none

Analog V

N

Defective ambient pressure sensor

Replace DME

MIL on in 2nd DC, US version only

none

0x2F77

12151

Ambient-pressure sensor, plausibility

Ambient Pressure Sensor

Pressure

Ambient pressure > 1150 hPa

5 sec.

Terminal 15=TRUE

9 V < U > 16 V

none

none

none

Analog V

N

Defective ambient pressure sensor

Replace DME

MIL on in 2nd DC, US version only

none

0x2DDC

11740

No message from SZL

No Info

No Info

No suspension of bus activity

1 sec.

800 ms after Terminal 15

battery voltage >10 V

none

No message for 240 ms (2 messages)

none

Check whether following CAN messages are present: Operation_Cruise control

Yes

ECU failure (SZL or ZGM) - Bus system failure - Defective bus controller (SZL or ZGM)

Check SZL-SG - Measure resistance on bus - Check wiring harness => Replace ECU as indicated

none

No Info

0x2DDC

11740

No message from SZL

No Info

No Info

No suspension of bus activity

400 ms (2 messages)

800 ms after Terminal 15

battery voltage >10 V

none

Checksum fault for 640 ms (3 messages)

none

Checksum check on cruise control_operation message

Yes

ECU failure (SZL or ZGM) - Bus system failure - Defective bus controller (SZL or ZGM)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

No Info

0x2ED1

11985

Generator, mechanical

No Info

No Info

Commercial vehicle >350 rpm, No communications fault

25 sec.

Terminal 15 ON, no BSD fault

Voltage in onboard electrical system > 10 V

none

none

none

none

N

Alternator fails to turn; bearing defect, belt slips or ruptures

Check alternator for turning resistance (binding), replace belt

Charge indicator lamp

New fault location ME9.2.3 Sometimes occurs with outside power supply during service

0x2E97

11927

Generator

No Info

No Info

Commercial vehicle >350 rpm, No communications faults at BSD interface

25 sec.

Terminal 15 ON

Voltage in onboard electrical system > 10 V

none

none

None

none

N

Alternator physically obstructed - Torn, loose, oil-soaked belt

Check alternator for easy rotation - Check belt

Charge indicator lamp Terminal 61

Can occur during vehicle servicing when external power source is connected, etc.

0x2E97

11927

Generator

No Info

No Info

Commercial vehicle >350 rpm, No communications faults at BSD interface

25 sec.

Terminal 15 ON

Voltage in onboard electrical system > 10 V

none

none

None

none

N

Alternator not approved for use in this vehicle installed

Install alternator with approved detail number

none

If detail number is ident to approved number, information through VS to EA

0x2F71

12145

Electronics-box fan, activation

No Info

No Info

Current on Pin 4--19 I > 2.2 A

n> 40 rpm

Terminal 15=TRUE

9.5 V < U < 17.9 V

none

after 800 ms

control_ebl

Low Side control signal

N

Driver circuit has detected short to battery voltage

Check wiring harness, otherwise replace DME

none

none

0x2F71

12145

Electronics-box fan, activation

No Info

No Info

Current on Pin 4--19 I > 2.2 A

n> 40 rpm

Terminal 15=TRUE

9.5 V < U < 17.9 V

none

after 800 ms

control_ebl

Low Side control signal

N

Driver circuit has detected short to ground

Check wiring harness, otherwise replace DME

none

none

0x2F71

12145

Electronics-box fan, activation

No Info

No Info

Current on Pin 4--19 I > 2.2 A

n> 40 rpm

Terminal 15=TRUE

9.5 V < U < 17.9 V

none

after 800 ms

control_ebl

Low Side control signal

N

Driver circuit has detected open wire

Check wiring harness, otherwise replace DME

none

none

0x2F77

12151

Ambient-pressure sensor, plausibility

Ambient Pressure Sensor

Pressure

Ambient pressure > 1150 hPa

5 sec.

Terminal 15=TRUE

9 V < U > 16 V

none

none

none

Analog V

N

Ambient pressure sensor jumps

Replace DME

MIL on in 2nd DC, US version only

none

0x2D70

11632

Control module, internal fault: monitoring of engine functions

ECM Monitoring

Error Response

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Internal fault in computer or internal fault in control modules

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fault is deactivated and cannot be entered

Fault is deactivated and cannot be entered

0x2D70

11632

Control module, internal fault: monitoring of engine functions

ECM Monitoring

Ignition Timing

Torque monitor

none

nmot > 1200 rpm

none

none

none

none

Ignition angle model value is implausible

Yes

Internal fault in computer or internal fault in control modules

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2D70

11632

Control module, internal fault: monitoring of engine functions

ECM Monitoring

Relative Charge

Torque monitor

none

nmot > 1200 rpm

none

none

none

none

Mass airflow model value is implausible relative to fuel injection quantity and lambda

Yes

Internal fault in computer or internal fault in control modules

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2D71

11633

Control module, internal fault: monitoring of input variables

ECM Monitoring

Throttle Valve

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Internal fault in computer or internal fault in control modules

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fault is deactivated and cannot be entered

Fault is deactivated and cannot be entered

0x2D71

11633

Control module, internal fault: monitoring of input variables

ECM Monitoring

Coding

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

Internal fault in computer or internal fault in control modules

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fault is deactivated and cannot be entered

ME9x does not have accelerator pedal code data - > Fault is deactivated and cannot be entered

0x2D71

11633

Control module, internal fault: monitoring of input variables

ECM Monitoring

Injection Time

Torque monitor

4.1 sec.

nmot > 1200 rpm

none

none

none

none

Model value for relative fuel mass

Yes

Internal fault in computer or internal fault in control modules

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2D71

11633

Control module, internal fault: monitoring of input variables

ECM Monitoring

Fuel Correction

Torque monitor

none

nmot > 1200 rpm

none

none

none

none

Model value for mixture correction is implausible

Yes

Internal fault in computer or internal fault in control modules

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2D72

11634

Control module, internal fault: monitoring of hardware

ECM Monitoring

TPU Chip

Torque monitor

none

nmot > 1200 rpm

none

none

none

none

AD converter internal test

Yes

Internal fault in computer or in electronic control modules (check whether all ADC channels have been converted)

If additional fault codes are entered in the DME, resolve these issues. If fault still remains current, replace DME.

Fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2FC6

12230

Energy-saving mode active

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

0x2FA3

12195

No coding

No Info

No Info

DME on

none

Terminal 15

none

none

none

none

Determine whether tester service code entries have been made

Yes

No code data yet in DME

Enter code data in DME

none

The ECU's code entries can only be reprogrammed in its initial ten hours of operation. The DME is then disabled for redefinitions of code data

0x2F77

12151

Ambient-pressure sensor, plausibility

Ambient Pressure Sensor

Driving Cycle Comparison

Ambient pressure > 1150 hPa

5 sec.

Terminal 15=TRUE

9 V < U > 16 V

none

none

none

Analog V

N

Defective ambient pressure sensor

Replace DME

MIL on in 2nd DC, US version only

none

0x2D78

11640

Air mass flow adjustment

ECM Monitoring

Air Mass Flow

Torque monitor

none

none

none

none

none

none

Internal mass airflow check

Yes

Fault in mass airflow calibration's internal control range monitor

If additional fault codes are stored in the DME, resolve these issues, if the fault still remains as a current problem, check or repair HFM, otherwise replace DME.

Fuel-supply safety shutdown

The torque monitoring feature compares the torque demand (from accelerator pedal, FGR, electrical equipment, transmission) with the torque provided (calculated from HFM, injector valves, ignition angle, throttle valve angle, differential pressure, lambda). Deviations trigger fuel-supply safety shutdown to prevent vehicle from autonomous acceleration.

0x2B98

11160

Control module, internal fault: RAM backup, plausibility

No Info

No Info

Counters in NVRAM and in RAM backup not identical

none

Terminal 15

none

none

none

deleted

none

N

Power module switched off Terminal 30 too quickly (possibly without warning) (owing to defective battery)

Check CAN network, replace battery as indicated

none

If the two monitoring counters fail to agree following a hardware power failure, all stored fault codes are deleted from the log and the fault DNVRBUP is entered in response to unreliable RAM backup. E70 application adjustments are pending

0x2ED3

11987

Generator, type incorrect

No Info

No Info

Commercial vehicle >350 rpm, No communications fault

25 sec.

Terminal 15 ON, no BSD fault

Voltage in onboard electrical system > 10 V

none

none

none

none

Yes

Alternator not approved for use in this vehicle installed

Install alternator with approved detail number

none

New fault location ME9.2.3 If detail number identical to approved number info through VS to EA

0x2E7C

11900

Bit-serial data interface, signal

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

none

none

Fault class not present

0x2ED0

11984

Generator, plausibility: temperature

No Info

No Info

Diagnosis not active, specific to application

Never, diagnosis not active

Terminal 15 ON, no BSD fault

none

none

none

none

none

Yes

Alternator airflow obstructed. Thermal overload from unfavorable driving profile possible.

Inspect alternator for unobstructed air current.

none

New fault location ME9.2.3

0x2ED2

11986

Generator, regulator incorrect

No Info

No Info

Implausible alternator regulator type

25 sec.

Terminal 15 ON, no BSD fault

none

none

none

none

none

Yes

Installed regulator was not approved for this vehicle/this alternator

Install regulator with approved detail number

none

New fault location ME9.2.3 If detail number identical to approved number info through VS to EA

0x2D72

11634

Control module, internal fault: monitoring of hardware

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

0x2ECE

11982

Generator, plausibility: electric

No Info

No Info

Specified alternator voltage > Application threshold 1 AND battery voltage < Application threshold 2; no electrical, mechanical or overheating faults, no active excitation current

Never, diagnosis not active

Terminal 15 ON

none

none

none

none

none

Yes

B+- Wire: Open or high contact resistance; Alternator defect Battery defect

Repair B+ wire Check alternator, repair as indicated Check battery, repair as indicated

Charge indicator lamp

New fault location ME9.2.3

0x2E6E

11886

not translated

Cylinder Deactivation System

General

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

New fault location ME9.2.3

0x2E6F

11887

not translated

Cylinder Deactivation System

General

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

New fault location ME9.2.3

0x2DCA

11722

No message from EGS

Communication

TCM

EGS vehicle

360 ms

800 ms after Terminal 15

battery voltage > 10 V

none

No message from EGS

none

Check to determine whether following CAN messages are present: EGS torque demand, transmission data

Yes

ECU failure (EGS) - Bus system failure - Defective bus controller (EGS)

Check EGS fuse - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated

US MIL

No Info

0x2DCB

11723

No message from SSG

Communication

TCM

E65: Data content defined E6x with SSG, no suspension of bus activity

400 ms

800 ms after Terminal 15

battery voltage > 10 V

none

none

none

Check to determine whether following CAN messages are present: SSG torque demand, transmission data

Yes

ECU failure (SMG) - Bus system failure - Defective bus controller (SMG)

Check SSG fuse - Measure resistance on bus - Check wiring harness => Replace defective ECU as indicated

US MIL

If this fault occurs on the E65 respond by downloading the correct data set. If this fault appears on the E6x without SMG, delete version Fault is not diagnosed after tester suspends bus activity (flash-programming ECU)

0xCDF9

52729

not translated

No Info

No Info

No suspension of bus activity

60 ms

60 ms after Terminal 15

battery voltage > 10 V

none

none

none

CAN message: (Status EMF, 201)

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCDFA

52730

not translated

No Info

No Info

No suspension of bus activity

600 ms

600 ms after Terminal 15

battery voltage > 10 V

none

none

none

CAN message (EMF positioning command, 1A7)

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCDEF

52719

No message (status, trailer, 2E4)

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

Check DME for correct data/program version

none

Diagnosis data content defined, fault can not be entered

0xCDF9

52729

not translated

No Info

No Info

No suspension of bus activity

60 ms

60 ms after Terminal 15

battery voltage >10 V

none

none

none

CAN message: (Status EMF, 201)

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCDFA

52730

not translated

No Info

No Info

No suspension of bus activity

600 ms

600 ms after Terminal 15

battery voltage > 10 V

none

none

none

CAN message (EMF positioning command, 1A7)

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

New fault location ME9.2.3

0x2DCF

11727

No message from instrument cluster

Communication

Instrument Pack

No suspension of bus activity

Separate message debounce: A_Temp_Relative time 4 sec., Milage 40 sec., Stat cluster 0.4 sec.

800 ms after Terminal 15

battery voltage >10 V

none

No message A_Temp_Relative time for 1200 ms or No millage message for 12 sec. or No Stat_Cluster message for 200 ms

none

Check to determine whether following CAN messages are present: A_Temp_Relative time, Mileage, Stat_Cluster

Yes

ECU failure (cluster) - Bus system failure - Defective bus controller (cluster)

Measure resistance on bus - Check instrument cluster ECU - Check ZGM - Check K-CAN - Check wiring harness => Replace ECU as indicated

US MIL

No Info

0xCDB7

52663

not translated

Communication

Instrument Pack

No suspension of bus activity

21 sec.

Terminal 15

battery voltage > 10 V

none

none

none

CAN message: OBD sensor diagnosis status, 5E0

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

MIL (2nd driving cycle)

New fault location ME9.2.3

0xCD97

52631

Message (torque request AFS, B9)

No Info

No Info

No suspension of bus activity

500 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Steering torque demand, B1

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCDB3

52659

Message (torque request, steering, B1h)

No Info

No Info

No suspension of bus activity

500 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Steering torque demand, B9

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCD97

52631

Message (torque request AFS, B9)

No Info

No Info

No suspension of bus activity

400 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Steering torque demand, B1

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCDB3

52659

Message (torque request, steering, B1h)

No Info

No Info

No suspension of bus activity

400 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Steering torque demand, B9

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCD9B

52635

Message (vehicle mode, 315)

No Info

No Info

E65 Data content defined E6x with Sport switch No suspension of bus activity

No supplementary debounce

E65 none E6x 800 ms after Terminal 15

battery voltage > 10 V

none

No message for 25.5 sec. (2 messages)

none

Check whether following CAN messages are present: Vehicle mode

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness - Replace defective ECU as indicated

none

If this fault is entered in an E60, check DME for correct data version/download correct data version

0xCD9B

52635

Message (vehicle mode, 315)

No Info

No Info

E65 Data content defined E6x with Sport switch No suspension of bus activity

E6x No supplementary debounce

800 ms after Terminal 15

battery voltage > 10 V

none

Checksum fault for 50 sec. (5 messages)

none

Checksum test on vehicle mode message

Yes

ECU failure (SZM) - Bus system failure - Defective bus controller (SZM)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

No Info

0xCDA1

52641

Message (steering wheel angle, C4)

No Info

No Info

No suspension of bus activity

400 ms

800 ms after Terminal 15

battery voltage >10 V

none

No message for 40 ms (2 messages)

none

Check whether following CAN message is present: Steering-wheel angle

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

No Info

0xCDA2

52642

Message (power management, battery voltage, 3B4)

Communication

Powermanagement

E60 Data content defined E65 no suspension of bus activity

E60 none E65 No supplementary debounce

800 ms after Terminal 15

battery voltage >10 V

none

No message for 25 sec. (5 messages)

none

E65: Check whether following CAN message is present: Powermanagement_Battery voltage

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

If this fault is entered in an E60, check DME for correct data version/download correct data version

0xCDA3

52643

Message (power management, charging voltage, 334)

No Info

No Info

E60 Data content defined E65 no suspension of bus activity

E60 none E65 No supplementary debounce

800 ms after Terminal 15

battery voltage >10 V

none

No message for 5 sec. (5 messages)

none

E65: Check whether following CAN message is present: Powermanagement_Charge voltage

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

If this fault is entered in an E60, check DME for correct data version/download correct data version

0xCDA7

52647

Message (status, reverse gear, 3B0)

No Info

No Info

E65 data content defined E6x Manual transmission only

E6x Manual transmission: 4 sec.

800 ms after Terminal 15

battery voltage >10 V

none

No message for 1.2 sec. (1 message)

none

Check whether following CAN message is present: Status_Gear_Reverse

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

If this fault code is entered on an E65 or E6x Aut/SMG, check DME for correct data version/download correct data version

0x2DCF

11727

No message from instrument cluster

Communication

Instrument Pack

No suspension of bus activity

300 ms

800 ms after Terminal 15

battery voltage > 10 V

none

Alive counter fault in 6 consecutive messages (600 ms)

none

Check alive counter for message Stat_Cluster

Yes

ECU failure (cluster) - Bus system failure - Defective bus controller (cluster)

Measure resistance on bus - Check instrument cluster ECU - Check ZGM - Check K-CAN - Check wiring harness => Replace ECU as indicated

US MIL

No Info

0xCDAA

52650

Message (status, crash deactivation, el. fuel pump, 135)

No Info

No Info

E65 data content defined

50 sec.

800 ms after Terminal 15

battery voltage >10 V

none

No message for 12 sec. (1 message)

none

Check whether following CAN message is present: Status_Crash deactivation

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

If this fault is entered in an E60, check DME for correct data version/download correct data version

0x2F11

12049

Radiator blind, top

No Info

No Info

Active cooling flap control must be initialized.

up to 20 sec.

Terminal 15 ON

Voltage in onboard electrical system > 10 V

none

none

In the SGBD: 'start_systemcheck_glf'

PWM of 5-90%

N

  1. Wire from DME to active cooling flap control is open. PVE: Interrupt wire from DME to active cooling flap control.
  1. Check wire from the DME to the active cooling flap control

no external display

New fault location ME9.2.3 No hazard is present provided that the voltage supply to the active cooling flap control is OK. (safety circuit in the active cooling flap control is active: both flaps remain open.)

0x2DDA

11738

No message from CAS

No Info

No Info

No suspension of bus activity

400 ms

800 ms after Terminal 15

battery voltage >10 V

none

No message for 40 ms (4 messages)

none

Check whether following CAN messages are present: Terminal status

Yes

ECU failure (CAS) - Bus system failure - Defective bus controller (CAS)

Check CAS fuse - Measure resistance on bus - Check wiring harness => Replace affected ECU as indicated

none

No Info

0x2ECC

11980

Generator, communication

No Info

No Info

Commercial vehicle >350 rpm, No communications fault

25 sec.

Terminal 15 ON, no BSD fault

Voltage in onboard electrical system > 10 V

none

none

none

none

N

  1. Alternator (BSD-BUS) not connected
  2. Open wire (BSD
  1. Check wire (BSD_BUS) BUS) between connecting alternator and alternator and DME. DME
  2. Check plug-in connection
  3. Alternator at alternator. defect
  4. Replace alternator.

none

New fault location ME9.2.3

No Info

0x2E7C

11900

Bit-serial data interface, signal

No Cell

No Cell

DME active

2 sec.

DME active

none

none

No signal for 2000 ms

none

Check to determine whether communications to a BSD component are possible

Yes

Faults in BSD bus system

Check BSD wire

none

none

0x2EBD

11965

No BSD message from generator

No Info

No Info

E65: Application data content defined E6x: Terminal 15

4 sec.

Terminal 15

none

none

10 component requests repeated 10 times before fault is logged

none

if the components fail to respond to request

Yes

BSD component failure Malfunctions/interference in BSD bus system

Check plug on alternator Inspect BSD wire Replace defective components as indicated

none

Revisions to application still pending for E70

0x2EBE

11966

No BSD message from generator 2

No Info

No Info

Alternator installed (E67 only)

4 sec.

Terminal 15

none

none

10 component requests repeated 10 times before fault is logged

none

if the components fail to respond to request

Yes

BSD component failure Malfunctions/interference in BSD bus system

Check plug on alternator 2 Inspect BSD wire Replace defective components as indicated

none

Revisions to application still pending for E70

0xCDED

52717

No message (request, wheel torque, drivetrain, BF)

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

No Info

0xCDEB

52715

Message (lamp status, 21A)

No Info

No Info

No suspension of bus activity

25 sec.

800 ms after Terminal 15

battery voltage >10 V

none

No message for 6 sec. (1 message)

none

Check whether following CAN message is present: Lamp status

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

No Info

0xCDAC

52652

Message (status, water valve, 3B5)

No Info

No Info

Fault not active in ME922T$UU/ME923

none

none

none

none

none

none

none

none

none

Check DME for correct data/program version

none

Data content defined

0xCDEE

52718

No message (time/date, 2F8)

No Info

No Info

No suspension of bus activity

75 sec.

800 ms after Terminal 15

battery voltage >10 V

none

No message for 18 sec. (1 message)

none

Check whether following CAN message is present: Time/date

Yes

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

No Info

0xCDED

52717

No message (request, wheel torque, drivetrain, BF)

No Info

No Info

Fault not active in ME922T$UU

none

none

none

none

none

none

none

none

none

Check DME for correct data/program version

none

Diagnosis data content defined, fault can not be entered

0xCDB3

52659

Message (torque request, steering, B1h)

No Info

No Info

No suspension of bus activity

500 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Steering torque demand, B9

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCDB3

52659

Message (torque request, steering, B1h)

No Info

No suspension of bus activity

500 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Steering torque demand, B9

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCDB0

52656

Message (display, transmission data)

No suspension of bus activity

200 ms

Terminal 15

battery voltage >10 V

none

none

none

CAN message: Transmission display, 1D2

N

ECU failure - Bus system failure - Defective bus controller

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

none

New fault location ME9.2.3

0xCDED

52717

No message (request, wheel torque, drivetrain, BF)

Fault not active in ME922T$UU

none

none

none

none

none

none

none

none

none

Check DME for correct data/program version

none

Diagnosis data content defined, fault can not be entered

0x2DDD

11741

No message from Valvetronic

Communication

Valvetronic (VVT) Control Module

CAN signals missing (time out)

> 500 ms

DME active

Terminal 87 > 7 V

none

500 ms

none

none

N

Short circuit in CAN wire or open circuit

Check wiring harness and plugs

MIL (2nd driving cycle)

none

0x2DDD

11741

No message from Valvetronic

Communication

Valvetronic (VVT) Control Module

VVT CAN message monitoring - Fault in monitored value

> 500 ms

DME active

Terminal 87 > 7 V

none

500 ms

none

none

N

Short circuit in CAN wire or open circuit

Check wiring harness and plugs

MIL (2nd driving cycle)

none

0x2DCA

11722

No message from EGS

Communication

TCM

EGS vehicle

20 ms

800 ms after Terminal 15

battery voltage >10 V

none

Message present, false checksum in 32 consecutive messages (320 ms)

none

Check on checksum for CAN message EGS torque demand

Yes

ECU failure (EGS) - Bus system failure - Defective bus controller (EGS)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

US MIL

No Info

0x2DCA

11722

No message from EGS

Communication

TCM

EGS vehicle

20 ms

800 ms after Terminal 15

battery voltage > 10 V

none

Message present, alive counter fault in 3 consecutive messages

none

Check on alive counter for CAN message EGS torque demand

Yes

ECU failure (EGS) - Bus system failure - Defective bus controller (EGS)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

US MIL

No Info

0x2DCA

11723

No message from SSG

Communication

TCM

E65: Data content defined E6x with SSG, no suspension of bus activity

200 ms

800 ms after Terminal 15

battery voltage >10 V

none

none

none

Check on CAN messages for Torque demand_SSG, check transmission data for correct checksum/alive counter. Plausibility check on time/quantity of torque demands from SSG

Yes

ECU failure (SMG) - Bus system failure - Defective bus controller (SMG)

Check other ECUs for CAN fault - Measure resistance on bus - Check wiring harness Replace defective ECU as indicated

US MIL

This fault cannot occur in E65 Fault is not diagnosed during passive bus state triggered by tester (flash-programming ECU)