BMW MSV80
MSV80 engine operating system applies to N54 engine. DTC P1214 - DTC U1168.
BMW Fault Code (hex)
0x2AAE
BMW Fault Code (dez)
10926
BMW Fault Code Description VS-Text
Fuel pump
Component
No Info
Subcomponent
No Info
Monitoring criteria
Self-diagnosis from EKP module fault memory entry via CAN
Fault debouncing
none
Terminal conditions
none
Voltage conditions
none
Temperature conditions
none
Time conditions
none
System test
none
Signal information
none
Calculated value Y/N
none
Possible Fault Causes
none
Repair procedures (plant/service)
none
MIL illumination/CC message/emergency program
none
Remarks
none
0x2AAE
10926
Fuel pump
No Info
No Info
Self-diagnosis from EKP module fault memory entry via CAN
none
none
none
none
none
none
none
none
none
none
none
none
0x2AAE
10926
Fuel pump
Fuel Regulators/Valves/Sensors
Fuel Pump
Self-diagnosis from EKP module fault memory entry via CAN.
none
none
none
none
none
none
none
none
none
none
none
none
0x2AAE
10926
Fuel pump
No Info
No Info
Self-diagnosis from EKP module fault memory entry via CAN
none
none
none
none
none
none
none
none
none
none
none
none
0x2F94
12180
Fuel-pump relay, activation
No Info
No Info
SIG
none
none
none
none
none
none
none
none
none
none
none
Data content defined
0x2F94
12180
Fuel-pump relay, activation
No Info
No Info
min
none
none
none
none
none
none
none
none
none
none
none
Data content defined
0x2F94
12180
Fuel-pump relay, activation
No Info
No Info
MAX
none
none
none
none
none
none
none
none
none
none
none
Data content defined
0x2AAD
10925
Fuel pump, emergency shutoff
Fuel Regulators/Valves/Sensors
Fuel Pump
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2AA2
10914
Camshaft sensor, inlet, gap loss
Camshaft Position Sensor
Intake Signal
NWE synchronous
On every camshaft flank if the flank ratio is not in tolerance.
Terminal 15 on
none
none
none
none
none
Y
Interference on the sensor signal
- Check signal wire for short to positive, ground, opens and interference pulses
- Replace camshaft exhaust side sensor
MIL 2nd DC, CAM operates in emergency default mode
Signal interference
0x2E18
11800
Firing, cylinder 1
No Info
No Info
Engine on, start phase completed, crankshaft absolves 48 revolutions after start (corresponding to approximately 5 sec. at idle), dual ignition off, secondary sparks off
Segment synchronization
Terminal 15 ON
Voltage in onboard electrical system > 11 V
Outside temperature > -9.8°C
t >5 sec.
none
none
N
Voltage supply and ground connection for ignition system spark plugs ignition coil.
Check wiring harness, ground connection and plug-in contacts. Visual inspection of spark plug, ignition coil (replace if damaged). After excluding all of these faults from consideration replace the control module.
none
none
0x2E19
11801
Firing, cylinder 2
No Info
No Info
Engine on, start phase completed, crankshaft absolves 48 revolutions after start (corresponding to approximately 5 sec. at idle), dual ignition off, secondary sparks off
Segment synchronization
Terminal 15 ON
Voltage in onboard electrical system > 11 V
Outside temperature > -9.8°C
t > 5 sec.
none
none
N
Voltage supply and ground connection for ignition system spark plugs ignition coil
Check wiring harness, ground connection and plug-in contacts. Visual inspection of spark plug, ignition coil (replace if damaged). After excluding all of these faults from consideration replace the control module.
none
none
0x2E1A
11802
Firing, cylinder 3
No Info
No Info
Engine on, start phase completed, crankshaft absolves 48 revolutions after start (corresponding to approximately 5 sec. at idle), dual ignition off, secondary sparks off
Segment synchronization
Terminal 15 ON
Voltage in onboard electrical system > 11 V
Outside temperature > -9.8°C
t >5 sec.
none
none
N
Voltage supply and ground connection for ignition system spark plugs ignition coil.
Check wiring harness, ground connection and plug-in contacts. Visual inspection of spark plug, ignition coil (replace if damaged). After excluding all of these faults from consideration replace the control module.
none
none
0x2E1B
11803
Firing, cylinder 4
No Info
No Info
Engine on, start phase completed, crankshaft absolves 48 revolutions after start (corresponding to approximately 5 sec. at idle), dual ignition off, secondary sparks off
Segment synchronization
Terminal 15 ON
Voltage in onboard electrical system > 11 V
Outside temperature > -9.8°C
t > 5 sec.
none
none
N
Voltage supply and ground connection for ignition system spark plugs ignition coil
Check wiring harness, ground connection and plug-in contacts. Visual inspection of spark plug, ignition coil (replace if damaged). After excluding all of these faults from consideration replace the control module.
none
none
0x2E1C
11804
Firing, cylinder 5
No Info
No Info
Engine on, start phase completed, crankshaft absolves 48 revolutions after start (corresponding to approximately 5 sec. at idle), dual ignition off, secondary sparks off
Segment synchronization
Terminal 15 ON
Voltage in onboard electrical system > 11 V
Outside temperature > -9.8°C
t > 5 sec.
none
none
N
Voltage supply and ground connection for ignition system spark plugs ignition coil.
Check wiring harness, ground connection and plug-in contacts. Visual inspection of spark plug, ignition coil (replace if damaged). After excluding all of these faults from consideration replace the control module.
none
none
0x2E1D
11805
Firing, cylinder 6
No Info
No Info
Engine on, start phase completed, crankshaft absolves 48 revolutions after start (corresponding to approximately 5 sec. at idle), dual ignition off, secondary sparks off
Segment synchronization
Terminal 15 ON
Voltage in onboard electrical system > 11 V
Outside temperature > -9.8°C
t > 5 sec.
none
none
N
Voltage supply and ground connection for ignition system spark plugs ignition coil.
Check wiring harness, ground connection and plug-in contacts. Visual inspection of spark plug, ignition coil (replace if damaged). After excluding all of these faults from consideration replace the control module.
none
none
0x2AA3
10915
Camshaft sensor, exhaust, space loss
Camshaft Position Sensor
Exhaust Signal
NWA synchronous
On every camshaft flank if the flank ratio is not in tolerance.
Terminal 15 on
none
none
none
none
none
Y
Interference on the sensor signal
- Check signal wire for short to positive, ground, opens and interference pulses
- Replace camshaft exhaust side sensor
MIL 2nd DC, CAM operates in emergency default mode
Signal interference
0x2E69
11881
Knock-sensor signal 2
Knock Sensor
Sensor 2
Knock sensor signal monitor. Vehicle road operation at > 2800 1 RPM (current data status, tends toward > 2560 RPM) and air mass > 180 mg/unit. It is not possible to clear fault by switching ignition terminals. Compliance with the activation conditions and absence of malfunction extending over several seconds are required before fault code can be cleared.
Yes, by event counter. Knock signal sensor must lie below threshold (differential knock signal < 180 mV < 200 mV) for 1...3 sec., then fault code is registered
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
min 1 sec., max 3 sec.
none
none
N
Knock sensor signal too high. Threaded sensor connection is loose or wire connecting knock sensor 2 to the engine-management ECU is shorted to positive
- Check knock sensor connection to verify that it is tight.
- Check wire connecting knock sensor 1 and engine-management control module
- Check for connection between knock sensor 1 and ground or positive
- Replace knock sensor
No warning message. (No closed-loop knock control available. Power loss, as engine reverts to operation in safe range.)
none
0x2E69
11881
Knock-sensor signal 2
Knock Sensor
Sensor 2
Knock sensor signal monitor. Vehicle road operation at >2800 1 RPM (current data status, tends toward > 2560 RPM) and air mass > 180 mg/unit. It is not possible to clear fault by switching ignition terminals. Compliance with the activation conditions and absence of malfunction extending over several seconds are required before fault code can be cleared.
Yes, by event counter. If knock sensor signal remains below threshold (differential knock signal > 4.8 V) for 1...3 sec. fault code is stored.
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
min 1 sec., max 3 sec.
none
none
N
Knock sensor signal too low. Threaded sensor connection is loose or wire connecting knock sensor 1 to engine-management ECU is open.
- Check knock sensor connection to verify that it is tight.
- Check wire connecting knock sensor 1 and engine-management control module
- Check for connection between knock sensor 1 and ground or positive
- Replace knock sensor
No warning message. (No closed-loop knock control available. Power loss, as engine reverts to operation in safe range.)
none
0x2E69
11881
Knock-sensor signal 2
Knock Sensor
Sensor 2
Knock sensor signal monitor. Vehicle road operation at > 2800 1 RPM (current data status, tends toward > 2560 RPM) and air mass > 180 mg/unit. It is not possible to clear fault by switching ignition terminals. Compliance with the activation conditions and absence of malfunction extending over several seconds are required before fault code can be cleared.
The debounce time is derived from assessment of statistical diagnosis
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
min 1 sec., max 3 sec.
none
none
N
Knock sensor signal too low. Threaded sensor connection is loose or wire connecting knock sensor 2 to engine-management ECU is open.
- Check knock sensor connection to verify that it is tight.
- Check wire connecting knock sensor 1 and engine-management control module
- Check for connection between knock sensor 1 and ground or positive
- Replace knock sensor
No warning message. (No closed-loop knock control available. Power loss, as engine reverts to operation in safe range.)
none
0x2E77
11895
Firing, voltage supply
No Info
No Info
Start process completed, ignition failure on all cylinders
Fault is detected when all combustion durations = 0 ms
Terminal 15, engine on
6 - 24 V
40°C - 150°C
none
none
none
N
Defect in central voltage supply (voltage supply, ignition wiring loom)
Check voltage supply and ignition wiring loom including interfaces
NO
Ignition failure encompassing all cylinders, fault detected when all combustion durations = 0 ms
0x29DA
10714
Crankshaft sensor, segment adaptation
Crankshaft Position Sensor
Signal
In the adaptation phases with active overrun injection deactivation
Violation of maximum approved adaptation range
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
Always active
none
none
Y
Crankshaft sensor, defective reluctor
Check and replace as indicated: Crankshaft sensor, reluctor
none
none
0x2DE2
11746
Tank fill level, right, signal
Fuel Level Sensor
Signal
Short circuit or open circuit in left-side level sensor, sensor resistance too low/high
90 sec.
Terminal 15, engine on
none
none
none
none
none
N
Sensor value too low/high
Check sensor resistance, determine location of open wire/short circuit (wiring harness, plug, cluster, junction box, tank)
NO
none
0x2DE1
11745
Tank fill level, left, signal
Fuel Level Sensor
Signal
Short circuit or open circuit in left-side level sensor, sensor resistance too low/high
90 sec.
Terminal 15, engine on
none
none
none
none
none
N
Sensor value too low/high
Check sensor resistance, determine location of open wire/short circuit (wiring harness, plug, cluster, junction box, tank)
NO
none
0x2A00
10752
Secondary-air system
Secondary Air System
Flow Check, 1+2
Activation conditions: - Engine start - Secondary air-injection must be active - Ambient temperature >3°C - 3.8°C < Coolant temperature < 50.3°C
40 sec.
Terminal 15, engine start
Vehicle electrical system voltage (battery voltage between 7 & 15 V)
Ambient temperature > 3°C, coolant start temperature between 3.8°C & 50.3°C
none
EOL test of secondary air-injection system (Do not run more than 5 EOL tests in succession; the SA pump can overheat)
none
N
Potential causes - Hose between SA pump and SA valve disconnected/damaged - Defective secondary air-injection pump - Defective secondary air-injection valve - Obstructed passage between secondary air injection valve and the exhaust banks (in engine block)
- Visual inspection from connecting hose between secondary air injection pump (SAP) and secondary air-injection valve (SAV). Replace the hose if it is damaged.
- Determine whether hose is connected. - if not - connect hose. A click must be audible when the hose is connected.
- Conduct EOL test and listen to determine whether SAP is running or not: - if yes - determine whether the pump is producing pressure (hold with hand), it should be possible to feel pressure - of not - check wiring to pump (plug, relay, wiring), conduct EOL test with pump supplied by separate 12 V power source.
MIL
none
0x29DC
10716
Cylinder injection cutout
Injection Deactivation
Low Fuel
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2A03
10755
Secondary-air pump relay, activation
Secondary Air System
Pump
Control activation monitor, in post-start phase when pump is triggered
0.5 sec. with pump active 5 sec. when inactive
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec. with pump active 5 sec. when inactive
Secondary air-injection system check
none
N
Short to ground in relay activation circuit
- Electrical check on wire
- Visual inspection of plug-in connectors (at both component and DME ends)
- Use tester to trigger components
- Relay replacement
MIL ON
Relay triggers secondary air-injection pump, initialization
0x2A03
10755
Secondary-air pump relay, activation
Secondary Air System
Pump
Control activation monitor, in post-start phase when pump is triggered
0.5 sec. with pump active 5 sec. when inactive
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec. with pump active 5 sec. when inactive
Secondary air-injection system check
none
N
Short to positive in relay activation circuit
- Electrical check on wire
- Visual inspection of plug-in connectors (at both component and DME ends)
- Use tester to trigger components
- Relay replacement
MIL ON
Relay triggers secondary air-injection pump, initialization
0x2D06
11526
Air-mass system
Mass Air Flow
General
Mass airflow data monitor 6% < relative charge <120% -20° < induction air temperature < 85°C 560 1 RPM < engine speed < 7200 RPM Time after start > 30 sec. Regardless of whether EVAP is active/inactive
0.2 sec.
Terminal 15, engine on
Voltage in onboard electrical system >= 10 V
Coolant temperature > -10°C
6.2 sec.
none
none
Y
MIN fault (HFM monitored data too low) - HFM signal wire shunt - Vacuum leak induction system/crankcase - for instance, oil filler cap open - for instance, induction system leak - for instance, brake servo leak - HFM sensor fault - Collateral malfunction: DISA positioning - Collateral malfunction: incorrect stroke registration.
- Visual inspection of HFM plug contacts
- Check wiring between HFM and DME
- Check induction system/crankcase for leaks (the positive crankcase ventilation system can allow vacuum leaks with air from the crankcase entering the manifold, for instance, if vacuum line from brake booster to vacuum pump is leaking)
- Check for DISA diagnostic fault code entries and DISA control operation (DISA fault does not prevent HFM plausibility check)
- Carry out VVT travel limit initialization routine
MIL ON
none
0x2D09
11529
THROTTLE
Throttle Control
Air Supply
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2D06
11526
Air-mass system
Mass Air Flow
General
Mass airflow data monitor 6% < relative charge <120% -20° < induction air temperature < 85°C 560 1 RPM < engine speed < 7200 RPM Time after start > 30 sec. Regardless of whether EVAP is active/inactive
0.2 sec.
Terminal 15, engine on
Voltage in onboard electrical system > = 10 V
Coolant temperature > -10°C
6.2 sec.
none
none
Y
MAX fault (HFM monitored data too high) - HFM signal wire shunt - HFM sensor fault - Collateral fault from incorrect DISA positioning - Collateral fault from incorrect stroke measurement
- Visual inspection of HFM plug contacts
- Check wiring between HFM and DME
- Check induction system/crankcase for leaks (the positive crankcase ventilation system can allow vacuum leaks with air from the crankcase entering the manifold, for instance, if vacuum line from brake booster to vacuum pump is leaking)
- Check for DISA diagnostic fault code entries and DISA control operation (DISA fault does not prevent HFM plausibility check)
- Carry out VVT travel limit initialization routine
MIL ON
none
0x2A17
10775
DMTL, system fault
EVAP System
Pump Current
DMTL component monitor
Following completion of DMTL check
Terminal 15 ON
10.95 < vehicle electrical system voltage < 14.5
1.5°C > Ambient temperature > 38°C
Following completion of DMTL check
DMTL Check
none
Y
Valve in DMTL defective
Replace DMTL
MIL ON
Installed in US only (initialization version)
0x2AD9
10969
EAC sensor, coding
Direct Ozone Reduction
Catalyst Temperature Sensor
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME
24 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
N
EAC sensor has been tampered with
Replace EAC sensor
MIL in second driving cycle
none
0x2AD8
10968
EAC sensor, monitoring
Direct Ozone Reduction
Catalyst Temperature Sensor
Coolant temperature > 86°C, Coolant temperature at radiator discharge >40°C --> meaning thermostat is certainly open and the EAC sensor in valid temperature range
At least twice (more often as required). Drive at least 30 sec. as during acceleration from rest in urban traffic.
none
UBatt >10 V
> -7°C
none
none
none
none
Sensor subjected to tampering has been installed, or sensor's installation location not as specified, or sensor is defective.
Check temperature gradient (Service Test); install new sensor as indicated
MIL in 2nd DC
none
0x2AD8
10968
EAC sensor, monitoring
Direct Ozone Reduction
Catalyst Temperature Sensor
Coolant temperature > 86°C, Coolant temperature at radiator discharge > 40°C --> meaning thermostat is certainly open and the EAC sensor in valid temperature range
At least twice (more often as required). Drive at least 30 sec. as during acceleration from rest in urban traffic.
none
UBatt >10 V
>-7°C
none
none
none
none
Sensor subjected to tampering has been installed, or sensor's installation location not as specified, or sensor is defective
Check temperature gradient (Service Test); install new sensor as indicated
MIL in 2nd DC
none
0x2A17
10775
DMTL, system fault
EVAP System
Pump Current
DMTL component monitor
After DMTL check is triggered 2 times
Terminal 15 ON
10.95 < vehicle electrical system voltage < 14.5
1.5°C > Ambient temperature > 38°C
After DMTL check is triggered 2 times
DMTL Check
none
Y
Moisture in the DMTL/DMTL heater defective
Replace DMTL
MIL ON
Installed in US only (initialization version)
0x2A17
10775
DMTL, system fault
EVAP System
Pump Current
DMTL component monitor
Roughly 1 minute after DMTL check is triggered
Terminal 15 ON
10.95< vehicle electrical system voltage<14.5
1.5°C > Ambient temperature > 38°C
Roughly 1 minute after DMTL check is triggered
DMTL Check
none
Y
Pump motor current too low, pump defective
Replace DMTL
MIL ON
Installed in US only (initialization version)
0x2A17
10775
DMTL, system fault
EVAP System
Pump Current
DMTL component monitor
Roughly 1 minute after DMTL check is triggered
Terminal 15 ON
10.95 < vehicle electrical system voltage < 14.5
1.5°C > Ambient temperature > 38°C
Roughly 1 minute after DMTL check is triggered
DMTL Check
none
Y
Pump motor current too high, pump resistance, locks up
Replace DMTL
MIL ON
Installed in US only (initialization version)
0x2A03
10755
Secondary-air pump relay, activation
Secondary Air System
Pump
Control activation monitor, in post-start phase when pump is triggered
0.5 sec. with pump active 5 sec. when inactive
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec. with pump active 5 sec. when inactive
Secondary air-injection system check
none
N
Interruption of relay activation current
- Electrical check on wire
- Visual inspection of plug-in connectors (at both component and DME ends)
- Use tester to trigger components
- Relay replacement
MIL ON
Relay triggers secondary air-injection pump, initialization
0x2EFF
12031
Electric fan, self-diagnosis
No Info
No Info
PWM > 10%
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
Ambient temperature > -20°C
Appears twice for 6 sec. each time; At ecfpwm (=pulse-duty factor?) > 10%. Roughly 115 sec. may elapse before fault code is registered in fault memory!
none
none
N
Fault in fan's electronic control circuit. Binding in fan blade assembly. Fan blade assembly seized.
- Disconnect plug from fan assembly. (otherwise there is an injury hazard)
- The fan moves freely Check and remove any foreign objects. --> Fan is mechanically seized: Replace fan --> Fan blades turn freely: Reconnect plug and use tester to activate fan at least 15%. --> Fan should start. --> Fan fails to start running: Replace fan assembly
no external display
An inoperative E fan can also cause the engine to overheat.
0x2F0F
12047
Radiator blind, self-diagnosis
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2AAB
10923
Variable intake system, self-diagnosis
No Info
No Info
Monitoring of DISA controller (large valve) Engine speed > 500 RPM
Valve must lock up mechanically 10 times in succession. (5x open and 5x closed)
Terminal 15 ON
Voltage in onboard electrical system > 10 V
Ambient temperature > -20°C
none
none
PWM between 15% and 70%
N
Fault in electronic valve control. Physical seizure of valve; Valve binding.
Replace large DISA valve
none
Reduced power in various rpm ranges; downward shift in torque curve
0x2AAC
10924
Variable intake system 2, self-diagnosis
No Info
No Info
Monitoring of DISA controller (no valve) Engine speed > 500 rpm
Valve must lock up mechanically 10 times in succession. (5x open and 5x closed)
Terminal 15 ON
Voltage in onboard electrical system > 10 V
Ambient temperature > -20°C
none
none
PWM between 15% and 70%
N
Fault in electronic valve control. Physical seizure of valve; Valve binding
Replace small DISA valve
none
Reduced power in various rpm ranges; downward shift in torque curve
0x2F11
12049
Radiator blind, top
No Info
No Info
- AKKS must be initialized. Operation of lower flap: 3 x open and 3 x closed or conduct the system test.
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
In the SGBD
PWM of 5-90%
N
Mech. defect in valve. Possibly from ice cover in winter, or valve mechanism is defective (also: internal fault) PVE: Hold valve on clamp
- Check AKKS for sticking and seizure. (may be iced up in winter)
- Use the tester to trigger the valve repeatedly. If OK Clear fault memory, conduct system test --> No fault code entry. If not OK: Replace AKKS and conduct test for GLF --> No fault code entry
no external display
There is no danger with the AKKS provided the malfunction did not arise while it was closed.
0x2F11
12049
Radiator blind, top
No Info
No Info
- AKKS must be initialized. Operation of lower flap: 3 x open and 3 x closed or conduct the system test.
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
In the SGBD
PWM of 5-90%
N
Electrical defect in valve actuator. PVE: Not possible without destroying the controller.
- Replace AKKS
no external display
There is no danger with the AKKS provided the malfunction did not arise while it was closed.
0x2F10
12048
Radiator blind, bottom
No Info
No Info
- PKKS must be initialized. Operation of lower flap: 3 x open and 3 x closed or conduct the system test
up to 20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
In the SGBD
PWM of 5-90%
N
- Fault in wire from AKKS to PKKS (all 3 fault classes)
- Fault in wire from PKKS to ground (open wire or short to UBatt)
- Retention solenoid defective (internal short or burned through)
- Check wire from AKKS PIN 4 to PKKS (connection +)
- Check ground connection to the PKKS
- Check retention solenoid (internal short or burned through)
no external display
There is no danger with the PKKS provided the malfunction did not arise while it was closed.
0x2E8B
11915
Intelligent battery sensor, signal
No Info
No Info
IBS: Interference with extended communications on BSD bus
10 sec.
none
none
none
none
none
none
N
- Brief bus fault
- Other defective BSD component interferes with BSD bus.
- Intermittent short to positive or ground
- Intermittent contact in BSD wire
- Defective battery sensor.
- Check BSD wire for sporadic shorts to battery voltage and ground
- Check for intermittent contacts
- Systematically disconnect other BSD components one after the other and replace as indicated
- If fault persists after clearing fault memory, replace battery sensor
- If fault memory entry is logged repeatedly, replace battery sensor
No warning lamp or CC status report
none
0x2E8B
11915
Intelligent battery sensor, signal
No Info
No Info
IBS: Interference in data communications on BSD bus
10 sec.
none
none
none
none
none
none
N
- BSD wire open
- Other defective BSD component interferes with traffic on BSD bus.
- Intermittent short to positive or ground
- Defective battery sensor.
- Check BSD wire for shorts to battery voltage and ground
- Check for open wires
- Disconnect other BSD components one after the other and replace as indicated
- If fault persists after clearing fault memory, replace battery sensor
- If fault memory entry is logged repeatedly, replace battery sensor
No warning lamp or CC status report
none
0x2E8E
11918
Intelligent battery sensor, communication
No Info
No Info
IBS communications monitor
10 sec.
Terminal 15 ON
Terminal 87 > 10.0 V
none
approximately 10 sec.
none
none
N
- Battery sensor not installed on battery, as optional equipment
- Open circuit in wire (BSD_BUS) between battery sensor and DME.
- Defective battery sensor.
- Determine whether battery sensor is installed. If not, use SGBD to delete all adaptation data and then switch ignition off/on.
- Check continuity in wire connecting DME to battery sensor (BSD_BUS)
- Ensure correct fit of battery sensor on battery ground terminal and check seating of all plugs
- Replace battery sensor.
No warning message. The alternator responds to loss of the BSD_BUS signal by charging at a constant 14.4 V battery.
none
0x2E8B
11915
Intelligent battery sensor, signal
No Info
No Info
IBS: Implausible SW version
10 sec.
none
none
none
none
none
none
N
Installed sensor incompatible or too old
Install sensor with current part number
No warning lamp or CC status report
none
0x2E8C
11916
Intelligent battery sensor, signal transmission
No Info
No Info
Implausible battery temperature measurement
10 sec.
none
none
none
none
none
none
N
Self-diagnosis has detected potential problem in its temperature measurement
- If fault persists after deletion of stored fault codes from log, replace battery sensor.
- If fault code is entered repeatedly, replace battery sensor.
No warning lamp or CC status report
none
0x2E8C
11916
Intelligent battery sensor, signal transmission
No Info
No Info
Implausible battery voltage measurement
10 sec.
none
none
none
none
none
none
N
Self-diagnosis has detected possible problem with its voltage measurement
- If fault persists after deletion of stored fault codes from log, replace battery sensor
- If fault code is entered repeatedly, replace battery sensor
No warning lamp or CC status report
none
0x2E8C
11916
Intelligent battery sensor, signal transmission
No Info
No Info
Implausible battery current measurement
10 sec.
none
none
none
none
none
none
N
Self-diagnosis has detected possible problem with its battery current measurement
- Check electrical system/alternator for overvoltage
- If fault remains after deleting stored fault codes from log, replace battery sensor
- If fault is logged repeatedly, replace battery sensor
No warning lamp or CC status report
none
0x2AAA
10922
Variable intake system, plausibility
No Info
No Info
6% < Relative charge <120% 560 RPM < Engine speed < 7200 RPM. Time after start > 30s. Regardless of whether EVAP is active/inactive = High load demand. Additional induction air restriction Induction air temperature = +60°C maximum. Induction air temperature = +0°C minimum.
none
Terminal 15, engine on
Voltage in onboard electrical system >= 10 V
Coolant temperature > - 10°C 0 < Induction air temperature < 60°C
1.1 sec.
none
none
Y
No pressure pulses in intake manifold prior to low switching speed (approximately 3200 1 rpm) or pulsation present after low switching speed. Valves fail to close completely or leak.
Remove DISA valves (both, as individual assessment of DISA 1/2 is not possible) and inspect - valves present? - Are seals and gaskets present? - Are seals and gaskets OK? - Does valve open/close completely?
none
Data content defined
0x2AAA
10922
Variable intake system, plausibility
No Info
No Info
6% < Relative charge <120% 560 rpm < Engine speed < 7200 rpm. Time after start > 30s Regardless of whether EVAP is active/inactive = High load demand. Additional induction air restriction. Induction air temperature = +60°C maximum. Induction air temperature = +0°C minimum.
none
Terminal 15, engine on
Voltage in onboard electrical system >= 10 V
Coolant temperature > - 10°C 0 < Induction air temperature < 60°C
1.1 sec.
none
none
Y
No pressure pulses in intake manifold prior to high switching speed (approximately 4400 1 rpm) or pulsation present after high switching speed. Valves fail to close completely or leak.
Remove DISA valves (both, as individual assessment of DISA 1/2 is not possible) and inspect - valves present? - Are seals and gaskets present? - Are seals and gaskets OK? - Does valve open/close completely?
none
Data content defined
0x2AA8
10920
Variable intake system, servomotor: activation
DISA (Differentiated Intake Manifold)
Electrical
Monitoring of DISA controller. Engine speed > 500 rpm.
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
none
N
Open circuit
- Check voltage supply to valve. (If positive power to the valve is missing or intermittent this fault code will be stored.)
- Check wiring. Repair if defective. If wiring is OK, proceed to check component.
none
Not in B30UL_US reduced power in various engine speed ranges; low torque curve.
0x2AA9
10921
Variable intake system, servomotor 2: activation
DISA (Differentiated Intake Manifold)
Electrical
Monitoring of DISA controller 2 actuator. Engine speed > 500 rpm.
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
none
N
Open circuit
- Check voltage supply to valve. (If positive power to the valve is missing or intermittent this fault code will be stored.)
- Check wiring. Repair if defective. If wiring is OK, proceed to check component
none
Not in B25UL and B30UL_US reduced power in various engine speed ranges; low torque curve
0x2AA8
10920
Variable intake system, servomotor: activation
DISA (Differentiated Intake Manifold)
Signal
Monitoring of DISA controller. Engine speed > 500 rpm.
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
5.5 sec.
none
none
N
Short circuit to ground in wire or component.
Check wiring. Repair if defective. If wiring is OK, proceed to check component.
none
Not in B30UL_US reduced power in various engine speed ranges; low torque curve
0x2AA9
10921
Variable intake system, servomotor 2: activation
DISA (Differentiated Intake Manifold)
Signal
Monitoring of DISA controller 2 actuator Engine speed > 500 rpm
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
5.5 sec.
none
none
N
Short circuit to ground in wire or component.
Check wiring. Repair if defective. If wiring is OK, proceed to check component.
none
Not in B25UL and B30UL_US reduced power in various engine speed ranges; low torque curve
0x2AA8
10920
Variable intake system, servomotor: activation
DISA (Differentiated Intake Manifold)
Signal
Monitoring of DISA controller Engine speed > 500 rpm
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
none
N
Wire is shorted to positive, or a short to positive is present in the component
Check wiring. Repair if defective. If wiring is OK, proceed to check component
none
Not in B30UL_US reduced power in various engine speed ranges; low torque curve
0x2AA9
10921
Variable intake system, servomotor 2: activation
DISA (Differentiated Intake Manifold)
Signal
Monitoring of DISA controller 2 actuator. Engine speed > 500 RPM
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
none
N
Wire is shorted to positive, or a short to positive is present in the component
Check wiring. Repair if defective. If wiring is OK, proceed to check component
none
Not in B25UL and B30UL_US reduced power in various engine speed ranges; low torque curve
0x2F80
12160
System time, plausibility
Engine Off Timer, External
Electrical
Terminal 15 on Engine running
2 Min
Terminal 15 on
Battery voltage > 10 V
Engine shutdown temperature > 85°C
Engine off time < 12 min or > 10 h
none
none
Y
Defective engine temperature sensor. Timer in instrument cluster is defective
Check engine temperature sensor. Check instrument cluster.
Mil in 2nd driving cycle
US only
0x2E8D
11917
Intelligent battery sensor, function
No Info
No Info
During Terminal 15/wakeup request from IBS and critical charge status. Short to ground in Terminal 15 wakeup wire.
10 sec.
none
none
none
none
none
none
N
- Terminal 15/wake-up wire shorted to ground
- Defective driver circuit in battery sensor
- With battery sensor disconnected, check Terminal 15/wake-up wire for shorts to ground
- Check for non-approved connection of supplementary electr. equipment to Terminal 15/wake-up wire
- If fault code is stored, replace battery sensor
No warning lamp or CC status report
none
0x2E8D
11917
Intelligent battery sensor, function
No Info
No Info
Terminal 15-Wakeup wire signal level implausible
10 sec.
With each change in terminal-15 status, i.e., off or on
none
none
none
none
none
N
- Terminal 15/wake-up wire open
- Intermittent open in Terminal 15/wake-up wire
- Terminal 15/wake-up wire shorted to ground or battery voltage
- Defective driver circuit in battery sensor
- Check Terminal 15/wakeup wire for opens and intermittent contacts
- With battery sensor removed and Terminal 15 off, check Terminal 15/wakeup wire for short to battery voltage -> Repair wire and/or check Terminal 15, control module wakeup
- With battery sensor removed and Terminal 15 on, check Terminal 15/wakeup wire for short to ground
- With battery sensor connected and Terminal 15 off, check Terminal 15/wakeup wire for shorts to battery voltage - > Replace battery sensor
- With battery sensor connected and Terminal 15 on, check Terminal 15/wakeup wire for shorts to ground -> Replace battery sensor
No warning lamp or CC status report
none
0x2E8D
11917
Intelligent battery sensor, function
No Info
No Info
IBS system fault
10 sec.
none
none
none
none
none
none
N
Self-diagnosis utility has detected internal IBS fault
Replace battery sensor
No warning lamp or CC status report
none
0x2E9F
11935
Oil condition sensor
Engine Oil Quality Sensor
Communication
The sensor fails to respond
30 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9 V
none
10 sec.
none
none
N
Defective oil sensor (no communications)
Wiring harness check/sensor replacement
CC message 182 - suppressed starting with E90 with BN2000
Engine must be between 900 rpm and 5000 rpm
0x2AC6
10950
Button, Dynamic Driving Control (SPORT button), signal
No Info
No Info
SPORT switch monitoring only with CAN-11 network
none
Terminal 15 ON
none
none
500 ms
none
none
N
Sensor wire shorted to positive or open circuit in wire
- Electrical check on switch wire and power wires
- Visual inspection of plug-in connections (on component and DME ends)
- Switch replacement
none
Voltage range diagnosis
0x2AC6
10950
Button, Dynamic Driving Control (SPORT button), signal
No Info
No Info
SPORT switch monitoring only with CAN-11 network
none
Terminal 15 ON
none
none
500 ms
none
none
N
Short to ground in switch wire
- Electrical check on switch wire and power wires
- Visual inspection of plug-in connections (on component and DME ends)
- Switch replacement
none
Voltage range diagnosis
0x2F80
12160
System time, plausibility
Engine Off Timer, External
Electrical
Terminal 15 on Engine running
2 Min
Terminal 15 on
Battery voltage > 10 V
Engine shutdown temperature > 85°C
none
none
none
Yes
CAN signal incorrect or not present
Check CAN signal
Mil in 2nd driving cycle
US only
0x2A99
10905
Crankshaft - exhaust camshaft, correlation
Crankshaft/Camshaft Position Sensor
Exhaust
NWA synchronized, adaptation enabled
On each camshaft tooth flank when the position is out of tolerance.
Terminal 15 on
none
none
none
none
none
Y
Position of NWA relative to crankshaft outside tolerance range.
- Check position (valve timing setting) of camshaft and reluctor
- Check timing chain and tensioner mechanism.
- Check VANOS solenoid for dirt and contamination
- Check torque on crankshaft center bolt
MIL 2nd DC, CAM operates in emergency default mode
Installation fault or mechanical malfunction in camshaft drive
0x2A98
10904
Crankshaft - inlet camshaft, correlation
Crankshaft/Camshaft Position Sensor
Intake
NWE synchronous, adaptation enabled
On each camshaft tooth flank when the position is out of tolerance.
Terminal 15 on
none
none
none
none
none
Y
Position of NWE relative to crankshaft outside tolerance range.
- Check position (valve timing setting) of camshaft and reluctor.
- Check timing chain and tensioner mechanism.
- Check VANOS solenoid for dirt and contamination.
- Check torque on crankshaft center bolt.
MIL 2nd DC, CAM operates in emergency default mode
Installation fault or mechanical malfunction in camshaft drive.
0x2DBE
11710
Active cruise control, blocked for driving cycle
No Info
No Info
Terminal 15 ON, ACC recognized
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
100 ms
none
none
N
Throttle valve fault, accelerator pedal fault, torque demand from ACC despite pressure on brake pedal.
Check fault memory for stored faults related to internal fault sources within DME (see at left). Otherwise check ACC control module.
ACC operation locked out for entire driving cycle
ACC interface deactivated for entire driving cycle
0x2DBE
11710
Active cruise control, blocked for driving cycle
No Info
No Info
Terminal 15 ON, ACC recognized
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
100 ms
none
none
N
Crankshaft fault, clutch switch fault, brakelight switch fault, CAN timeout on DSC, ACC, instrument cluster or EGS.
Check fault memory for stored faults related to internal fault sources within DME (see at left).
ACC operation cancelled while fault is active
Temporary deactivation of ACC interface
0x2DB7
11703
Cruise control, time limit of data transmission reached
No Info
No Info
- CAN 11 vehicle (E46, E85, E83)
- Multifunction steering wheel installed
- Any MF-wheel button pressed
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
1700 ms
none
none
Y
Defective MFL module, open PIN 2--04 wire
- Visual inspection of plug contacts (component and DME ends)
- Electrical check of wiring
- Replace MFL module
Vehicle speed controller deactivated, no warning lamp
No signal received from MFL module
0x2AE0
10976
Idle speed control during cold start, plausibility
Idle Speed Control
Cold Start RPM
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2AE0
10976
Idle speed control during cold start, plausibility
Idle Speed Control
Cold Start RPM
Idle = ON VS = 0 km/h High idle for catalyst heating = On
20 sec.
Engine must be running
none
>-10°C
Roughly 120 seconds, varies according to start temperature
none
none
none
Not possible to maintain idle speed at specified level including offset for catalyst heating
Note any other fault code entries and repair the associated problems! Check all load-responsive servo actuators such as Valvetronic and the throttle valve for stored control module fault memory entries and malfunctions! (check injection and induction system as indicated).
MIL on in 2nd driving cycle
US only
0x2DB6
11702
Cruise control, switch, multifunction steering wheel
No Info
No Info
Simultaneous recognition of pressure on '+' and '-' buttons
- CAN 11 vehicle (E46, E85, E83)
- Multifunction steering wheel present
- MF wheel S/B button or VE pressed
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
800 ms
none
none
N
Internal short circuit between '+' and '-' buttons in MFL module, or mechanical defect allowing simultaneous operation.
- Visual inspection of MFL module (buttons: '+' and '-')
- Replace MFL module
Vehicle speed controller deactivated, no warning lamp
Simultaneous pressure on '+' and '-' buttons detected
0x2DB5
11701
Cruise control, signal
No Info
No Info
Redundancy fault in transmitting cruise control user input
- CAN 11 vehicle (E46, E85, E83)
- Multifunction steering wheel present
- MF-wheel button WA, S/B or OFF is pressed
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
800 ms
none
none
N
Defective MFL module
Replace MFL module
Vehicle speed controller deactivated, no warning lamp
not translated
0x30C2
12482
Oil-pressure control valve, activation
No Info
No Info
Monitored at: 10% PWM < Control activation PWM to oil pump < 94% PWM (idle)
1 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
PWM of 0-100%
N
Wire is shorted to positive, or a short to positive is present in the component
- Check wiring. Repair if defective. If wiring is OK, proceed to check component
none
none
0x30C2
12482
Oil-pressure control valve, activation
No Info
No Info
Monitored at: 10% PWM < Control activation PWM to oil pump < 94% PWM (idle)
1 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
PWM of 0-100%
N
Short circuit to ground in wire or component.
- Check wiring Repair if defective If wiring is OK proceed to check component
none
none
0x30C2
12482
Oil-pressure control valve, activation
No Info
No Info
Monitored at: 10% PWM < Control activation PWM to oil pump < 94% PWM (idle)
1 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
PWM of 0-100%
N
Open circuit
- Check wiring. Repair if defective. If wiring is OK proceed to check component
none
none
0x2E9F
11935
Oil condition sensor
Engine Oil Quality Sensor
Temperature
Incorrect level measurement
30 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9 V
none
10 sec.
none
none
N
Defective oil sensor (temperature sensor)
Sensor replacement
CC message 182 - suppressed starting with E90 with BN2000
Engine must be between 900 RPM and 5000 RPM
0x2E9F
11935
Oil condition sensor
Engine Oil Quality Sensor
Level
Incorrect temperature measurement
30 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9 V
none
10 sec.
none
none
N
Defective oil sensor (level sensor)
Sensor replacement
CC message 182 - suppressed starting with E90 with BN2000
Engine must be between 900 RPM and 5000 RPM
0x2E9F
11935
Oil condition sensor
Engine Oil Quality Sensor
Permeability
Permittivity measurement defective
30 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9 V
none
10 sec.
none
none
N
Defective oil sensor (permittivity sensor)
Sensor replacement
CC message 182 - suppressed starting with E90 with BN2000
Engine must be between 900 rpm and 5000 rpm
0x30C4
12484
Engine-oil-pressure control, mechanical
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x30C4
12484
Engine-oil-pressure control, mechanical
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x30C5
12485
Engine-oil pump, mechanical: engine-oil pressure
No Info
No Info
Commercial vehicle >0 + Stored operating coordinate reached (depends on NKW+Tmot)
0.2
Terminal 15
none
>-10°C
none
Jump in specified pressure, specified pressure ramp
Analogous to oil pressure signal
N
Pump control plunger is seizing
Replace oil pump
NO
Activation only in Prg. Version 500
0x30C6
12486
Engine-oil-pressure sensor, plausibility
No Info
No Info
NKW=0, Terminal 15, the barometric pressure sensor must not be malfunctioning
0.2
Terminal 15
none
none
Minimum deactivation time over Tmot
Jump in specified pressure, specified pressure ramp
Analogous to oil pressure signal
N
Pressure indicated by oil pressure sensor it too high
Replace oil pressure sensor
NO
Implementation on at Prg. Version 500
0x30C6
12486
Engine-oil-pressure sensor, plausibility
No Info
No Info
NKW=0, Terminal 15, the barometric pressure sensor must not be malfunctioning
0.2
Terminal 15
none
none
Minimum deactivation time over Tmot
Jump in specified pressure, specified pressure ramp
Analogous to oil pressure signal
N
Pressure indicated by oil pressure sensor is too low
Replace oil pressure sensor
NO
Implementation on at Prg. Version 500
0x2DC3
11715
Monitoring, terminal 15
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2DC3
11715
Monitoring, terminal 15
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2DC3
11715
Monitoring, terminal 15
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2DC3
11715
Monitoring, terminal 15
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2DEC
11756
Power management, battery
Powermanagement
Electrical
Deep discharge: Battery sensor data recognized under all conditions.
Deep discharge: 60 seconds below 9.52 V (debounced in SW)
none
Onboard electrical system voltage < 9.52 V
none
60 sec.
none
none
N
High energy consumption in parked vehicle leads to battery damage.
Conduct energy diagnosis: Check control modules for standby current faults. Check battery's suitability for use, recharge or replace as indicated.
No CC message
none
0x2DEC
11756
Power management, battery
Powermanagement
Electrical
is not now used
none
none
none
none
none
none
none
none
none
none
No CC message
none
0x2DEB
11755
Power management, vehicle electrical system
Powermanagement
Electrical
Overvoltage with engine running
Voltage in onboard electrical system > K_OSPGAPP (16 V) for 10 sec. (debounced in SW)
Terminal 15, engine on
Voltage in onboard electrical system > 16 V
none
10 sec.
none
none
N
Defective alternator
Perform alternator diagnosis.
No CC message
none
0x2DEB
11755
Power management, vehicle electrical system
Powermanagement
Electrical
Low voltage while engine is running
Vehicle electrical system voltage < K_USPGAPP (10.5 V) for 10 sec. (debounced in SW)
Terminal 15, engine on
Onboard electrical system voltage < 10.5 V
none
10 sec.
none
none
N
Defective alternator
Perform alternator diagnosis.
No CC message
none
0x2DEB
11755
Power management, vehicle electrical system
Powermanagement
Electrical
Operation without battery with engine running Voltage fluctuations caused by poor battery contacts
Vehicle electrical system voltage < K_USPGAPP (10.5V) for 10 sec. (debounced in SW)
Terminal 15, engine on
Substantial voltage fluctuations (10.5 V -14 V)
none
approximately 200 ms
none
none
Y
Battery not correctly connected.
Check battery terminals
CC message 'Check battery connections'
none
0x2DED
11757
Power management, closed-circuit current violation
Powermanagement
Electrical
Standby current violation: Standby current draw exceeds approved level. Standby current is calculated only when ISD-BSD communications are not present - vehicle in sleep mode.
Vehicle in sleep mode
none
none
none
none
none
none
Y
High energy draw when parked
Conduct energy diagnosis
CC message 'High battery discharge when parked'
none
0x2D5C
11612
DME, internal fault: monitoring, hardware
ECM Self-Test
AD-Converter
AD converter monitor. Comparison of two AD converter results
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault
Replace DME
MIL OFF EML ON CC: Reduced power, engine malfunction RPM limited to 1300 rpm.
AD converter monitor
0x2D1E
11550
Accelerator-pedal module, pedal-position sensor 2, voltage supply
Pedal Position Sensor
E Electrical
Pedal-position sensor monitor
0.02 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
220 ms
none
none
N
Short circuit to ground in voltage supply for Channel 2, defective voltage regulator, main relay activation lag
- Check fault memory for problem with throttle valve and/or main relay, replace main relay as indicated
- Check power-supply wire for short to ground (also measure in PWG)
- Replace DME
CC status report: Reduced engine power! EML ON restricted PW gradient and PW limit via RPM
When relay is defective the fault appears together with throttle valve fault, the symptom being 'short circuit to ground', and fault in voltage supply to pedal-position sensor Channel 2.
0x2CFB
11515
Throttle-valve adaptation value
Throttle Actuator
Adaptation
at time of adaptation request
none
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
Intake air temperature > -10°C or Coolant temperature > - 10°C or Coolant temperature < 142°C
80 ms after Terminal 15 ON
none
none
Y
Violation of adaptation conditions prior to completion of adaptation routine: Terminal 15 off or Electr. system voltage < 10 V or RPM > 32 RPM or Speed > 2 km/h or Throttle valve fault or PWM throttle valve control fault
- Check adaptation conditions, following confirmation proceed to terminal switch
CC status report: Reduction in engine performance!, MIL ON Throttle valve emergency default mode + speed governed to 1300 RPM
Adaptation condition monitor
0x2CFB
11515
Throttle-valve adaptation value
Throttle Actuator
Adaptation
Terminal change and request for adaptation
none
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
Intake air temperature > -10°C or Coolant temperature > -10°C or Coolant temperature < 142°C
none
none
none
Y
Not possible to initialize for emergency air position: Contact resistance in plug-in connection, throttle valve has electrical problem or mechanical seizure.
- Check: Sum of throttle valve voltages must equal 5 V
- Perform electrical check on wires to throttle valve sensors, Visual inspection of plug-in terminals (on components, wiring harness and DME)
- Component defect improbable, replace throttle valve only in emergency
CC status report: Reduced engine performance!, MIL ON EMB + RPM limit 1300 RPM
Emergency air position adaptation monitor
0x2CFC
11516
Throttle valve, start check
Throttle Actuator
Adaptation
Switch terminals
1 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
Intake air temperature > -10°C or Coolant temperature > - 10°C or Coolant temperature < 142°C
none
none
none
Y
System fails spring test: Problem with voltage supply, Throttle valve is physically seizing or throttle valve motor is defective.
- Check engine-management fuses (5-fuse holder in E-Box)
- Perform electrical check on wiring to throttle valve sensors and throttle valve motor
- Visual inspection of plug-in terminals (at components, wiring harness and DME)
- Replace component
CC status report: Reduced engine performance!, MIL ON EMB + RPM limit 1300 RPM
Spring test, actually test to determine whether throttle valve is seizing
0x2CFE
11518
Throttle valve, continuous adaptation
Throttle Actuator
Adaptation
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2CEF
11503
Throttle-valve actuator, activation
Throttle Actuator
Power Stage
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2CEE
11502
Throttle-valve actuator, sluggish movement
Throttle Actuator
Position Control
Throttle valve test. Engine must be running. Throttle valve adaptation must not be in progress. Throttle valve actuator must be under current. No emergency default mode operation.
less than 1 sec.
Terminal 15 ON
none
none
none
none
none
N
Problem with voltage supply, Mechanical binding in throttle valve assembly
- Check engine-management fuses (5-position fuse box in E-module)
- Visual examination of contacts on throttle valve plug
- Check throttle valve for binding and replace component as indicated
CC status report: WAL_1, reduced engine power!, MIL None activation control via lv_err_tps_obd, operation in emergency default mode if trigger point reached otherwise EMB + engine speed governed to 1300 RPM
Control deviation TPS_SP to TPS_AV for longer than 1s in excess of 10°TPS
0x2CEC
11500
Throttle-valve actuator, jamming briefly
Throttle Actuator
Throttle Stuck
Throttle valve test. Engine must be running. Throttle valve adaptation must not be in progress. Throttle valve actuator must be under current. No emergency default mode operation
0.5 sec.
Terminal 15 ON
none
none
none
none
none
N
Problem with voltage supply, throttle valve physically seized
none
none
Pulse-duty factor for control activation of throttle valve motor at least 0.5 sec, but less than 1 sec. over 99%
0x2CED
11501
Throttle-valve actuator, jamming continuously
Throttle Actuator
Throttle Stuck
Throttle valve test. Engine must be running. Throttle valve adaptation must not be in progress. Throttle valve actuator must be under current. No emergency default mode operation
1 sec.
Terminal 15 ON
none
none
none
none
none
N
Problem with voltage supply, throttle valve physically seized
- Check engine-management fuses (5-fuse holder in E module)
- Visual inspection of throttle valve plug contacts and electrical check on throttle valve motor wires
- Check throttle valve for binding and replace component as indicated
CC status report: WAL_1, reduced engine power!, MIL None activation control via lv_err_tps_obd, operation in emergency default mode if trigger point reached otherwise EMB + engine speed governed to 1300 RPM
Pulse-duty factor for control of throttle valve motor exceeds 1s over 99%
0x2CFB
11515
Throttle-valve adaptation value
Throttle Actuator
Adaptation
Terminal change and request for adaptation
none
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
Intake air temperature > -10°C or Coolant temperature > - 10°C or Coolant temperature < 142°C
none
none
none
Y
System unable to initialize for lower mechanical travel stop position: Contact resistance in plug-in connection. Throttle valve is contaminated, has electrical problem or mechanical seizure
- Check: Sum of throttle valve voltages must equal 5 V
- Perform electrical check on wires to throttle valve sensors, visual inspection of plug-in terminals (at components, wiring harness and DME)
- Check to determine whether objects that could physically prevent the throttle valve from closing are present in the intake manifold or throttle valve
- Replace component
CC status report: Reduced engine performance!, MIL ON EMB + RPM limit 1300 RPM
Lower mechanical travel stop monitor
0x2D1D
11549
Accelerator-pedal module, pedal-position sensor 1, voltage supply
Pedal Position Sensor
D Electrical
Pedal-position sensor monitor
0.02 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
220 ms
none
none
N
Short circuit to ground in voltage supply for Channel 1, defective voltage regulator, main relay activation lag
- Check fault memory for problem with throttle valve and/or main relay, replace main relay as indicated
- Check power-supply wire for short to ground (also measure in PWG)
- Replace DME
CC status report: Reduced engine power! EML ON restricted PW gradient and PW limit via RPM
ATTENTION: This fault can produce throttle valve fault and HFM fault with the symptom 'short to ground' as collateral fault. When relay is defective this fault appears together with throttle valve fault, the symptom being 'short circuit to ground', and fault in voltage supply to pedal-position sensor Channel 2.
0x2F4A
12106
Interface EWS-DME
No Info
No Info
EWS code request
2
Terminal 15 on without running engine
none
none
none
none
CAS bus telegram
N
Signal interference on D_EWS wire.
Problem diagnosis on wire, then DME/DDE problem diagnosis.
none
none
0x2F4A
12106
Interface EWS-DME
No Info
No Info
EWS code request
2
Terminal 15 on without running engine
none
none
none
none
CAS bus telegram
N
Telegram structure not as expected
Continue problem diagnosis with CAS
none
none
0x2F4B
12107
DME, internal fault: immobilizer data
No Info
No Info
Calibration procedure
1
Terminal 15
none
none
none
none
none
N
Storage for EWS calibration not available
Replace DME
none
none
0x2F4B
12107
DME, internal fault: immobilizer data
No Info
No Info
Calibration procedure
1
Terminal 15
none
none
none
none
none
N
Enable code storage defective
Replace DME
none
none
0x2F4B
12107
DME, internal fault: immobilizer data
No Info
No Info
Terminal 15
1
Terminal 15
none
none
none
none
none
N
Fault in checksum for EWS data content
Replace DME, if fault occurs repeatedly
none
none
0x2CA6
11430
Oxygen sensor heating before catalytic converter, function
Oxygen Sensor, Front
ECM Self-Test
Internal control-module fault, attempt to determine O2 sensor temperature failed. No fault memories.
Processor chip monitor, no valid temperature for more than 5 sec.
Terminal 15, engine on
none
none
Roughly 40 sec. after engine start; after approximately 15 sec. in standard operation.
none
none
N
Invalid sensor temperature. Defective processing chip in control module.
Replace DME
none
none
0x2F4A
12106
Interface EWS-DME
No Info
No Info
EWS code request
2
Terminal 15 on without running engine
none
none
none
none
CAS bus telegram
N
Telegram structure not as expected
Continue problem diagnosis with CAS
none
none
0x2F4A
12106
Interface EWS-DME
No Info
No Info
EWS code request
2
Terminal 15 on without running engine
none
none
none
none
CAS bus telegram
N
Wiring harness defect in wire D_EWS; CAS defect; DME/DDE defect
Check D_EWS wire
none
none
0x2F49
12105
EWS preventing manipulation
No Info
No Info
none
1
Terminal 15
none
none
none
none
none
N
No start value yet programmed.
Program start value
none
Start data can only be programmed at the factory
0x2F49
12105
EWS preventing manipulation
No Info
No Info
none
1
Terminal 15
none
none
none
none
none
N
Content of telegram transmitted by CAS is not as expected
Replace CAS/EWS and DME/DDE
none
New control modules can only be calibrated at the factory; the control modules were mutually switched.
0x2F4B
12107
DME, internal fault: immobilizer data
No Info
No Info
Terminal 15
1
Terminal 15
none
none
none
none
none
N
Secret Key storage defective
Replace DME, if fault occurs repeatedly
none
none
0x2D50
11600
DME, internal fault: monitoring, cruise control
No Info
No Info
Control module monitoring. Throttle valve not without current, LDM initialized. Interface fails to detect implausible torque demand.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Unrecognized implausible torque demand, internal control-module fault.
Check CAN, LDM control module If frequency is >=3. Replace DME
MIL OFF EML OFF CC: Vehicle speed control. Vehicle speed controller is rejected.
LDM torque demand monitor
0x2DC0
11712
No message from LDM
No Info
No Info
LDM recognized
none
Terminal 15 ON
none
none
500 ms
none
none
N
LDM fails to deactivate despite pressure on brake pedal
Check LDM and brakelight switch/wiring
none
Breakpoint: Program version '600'
0x2DC0
11712
No message from LDM
No Info
No Info
LDM recognized
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
80 ms
none
none
N
LDM transmits implausible request
Check LDM and replace as indicated
none
Breakpoint: Program version '600'
0x2CA7
11431
Oxygen sensor heating before catalytic converter 2, function
Oxygen Sensor, Front
ECM Self-Test
Internal control-module fault, attempt to determine O2 sensor temperature failed. No fault memories
Processor chip monitor, no valid temperature for more than 5 sec.
Terminal 15, engine on
none
none
Roughly 40 sec. after engine start; after approximately 15 sec. in standard operation
none
none
N
Invalid sensor temperature. Defective processing chip in control module
Replace DME
none
none
0x2CFD
11517
No throttle-valve adaptation value
Throttle Actuator
Adaptation
Switch terminals
1 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
Intake air temperature > -10°C or Coolant temperature > -10°C or Coolant temperature < 142°C
none
none
none
Y
Not possible to initialize for emergency air position: Contact resistance in plug-in connection, throttle valve has electrical problem or mechanical seizure.
- Note collateral issues related to initial adaptation
- Check: The sum of throttle valve voltages must equal 5 V
- Perform electrical check on wiring to throttle valve sensors and throttle valve motor, visual inspection of plug-in contacts (at component, wiring harness and DME)
- Replace component
CC status report: Reduced engine performance!, MIL ON EMB + RPM limit 1300 RPM
Not possible to initialize for emergency air position, leading to demand for basic adaptation
0x2CFB
11515
Throttle-valve adaptation value
Throttle Actuator
Spring Test
Terminal change and request for adaptation
none
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
Intake air temperature > -10°C or Coolant temperature > -10°C or Coolant temperature < 142°C
none
none
none
Y
Emergency air position outside tolerance range or spring test failed: Problem with voltage supply. Contact resistance in plug-in connection. Throttle valve is physically seizing or electrical problem.
- Check engine-management fuses (5-fuse holder in EBOX)
- Check: The sum of throttle valve voltages must equal 5 V
- Perform electrical check on wiring to throttle valve sensors and throttle valve motor
- Visual inspection of plug-in contacts (at component, wiring harness and DME)
- Replace component
CC status report: Reduced engine performance!, MIL ON EMB + RPM limit 1300 RPM
Spring test and check on emergency air position
0x2CFC
11516
Throttle valve, start check
Throttle Actuator
Adaptation
Switch terminals
1 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
Intake air temperature > -10°C or Coolant temperature > - 10°C or Coolant temperature < 142°C
none
none
none
Y
Emergency air position outside approved tolerance range: Contact resistance in plug connector, throttle valve with electrical problem or seizing mechanically.
- Check: Sum of throttle valve voltages must equal 5 V
- Perform electrical check on wires to throttle valve sensors
- Visual inspection of plug-in terminals (at components, wiring harness and DME)
- Component defect is unlikely, replace throttle valve only in an emergency
CC status report: Reduced engine performance!, MIL ON EMB + RPM limit 1300 RPM
Check emergency air position
0x2AB3
10931
DME, internal fault: checksum
ECM/TCM
Checksum
Monitoring of boot software. After system start with ignition on
No debounce. Fault can be reset by clearing fault memory. However, a successful diagnostic cycle must be completed before the fault can be deleted. This can take several minutes.
Terminal 15 ON
none
none
none
none
none
Y
Fault in boot software (program code). Incorrect program version flash-programmed.
Flash program correct program version.
none
Engine operation no longer possible
0x2AB3
10931
DME, internal fault: checksum
ECM/TCM
Checksum
Application software program monitor (development only)
none
none
none
none
none
none
none
Y
Fault in application software (program code). Incorrect program version flash-programmed.
Flash program correct program version.
none
Engine operation no longer possible
0x2AB3
10931
DME, internal fault: checksum
ECM/TCM
Checksum
Application software data monitor (development only)
none
none
none
none
none
none
none
Y
Fault in application data (data file) The wrong data version has been flash-programmed
Flash program correct software revision.
none
Engine operation no longer possible
0x2AB4
10932
DME, internal fault: RAM checksum
ECM/TCM
NVMY
RAM checksum test. This test is executed once, while the control module is booting.
No debounce. Fault can be reset by clearing fault memory.
Immediately after wakeup in dormant control module.
none
none
none
none
none
Y
Defective data sector in DME's internal EEPROM. Poor or loose ground connections for the ignition coils.
Start by checking ground connections on the ignition coils. If these are OK, proceed with the following steps. Check to determine whether the diagnostic fault code is stored again after proceeding through the following routine. If yes: Replace DME.
- Clear fault memory
- Ignition off, allow vehicle to assume complete dormant status
- Ignition on
- Read out stored fault codes from fault memory
none
Possible loss of adaptation data. The following procedure can be used to reprogram the adaptation data
- Delete all adaptation data
- Ignition off and then on
- Brief drive. Adaptation data are reprogrammed automatically.
0x2AB5
10933
DME, internal fault: knock-sensor module
ECM
Knock Sensor
Monitoring of knock sensor chip Engine speed >320 rpm
Yes, by event counter. Fault must occur ten times before a fault memory entry is made.
Terminal 15, engine on
none
none
none
none
none
none
Interference at internal DME data bus (SPI_BUS) for processing chip for the knock sensors.
Determine whether fault is stored again after carrying out the following procedure. If yes: Replace DME.
- Clear fault memory
- Ignition off, allow vehicle to assume complete dormant status
- Ignition on
- Read out stored fault codes from fault memory
none
No warning message. No closed-loop knock control available. Performance loss as engine reverts to operation in safe range.
0x2AB6
10934
DME, internal fault: multiple output-stage module
ECM
Multiple Output Stage
Driver circuit monitor
Yes, by event counter. Fault must occur ten times before a fault memory entry is made.
Terminal 15 ON
none
none
none
none
none
none
Interference at internal DME data bus (SPI_BUS) for activation of driver circuits.
Determine whether fault is stored again after carrying out the following procedure. If yes: Replace DME.
- Clear fault memory
- Ignition off, allow vehicle to assume complete dormant status
- Ignition on
- Read out stored fault codes from fault memory
No warning message. No control activation possible from some DME output terminals.
none
0x2D50
11600
DME, internal fault: monitoring, cruise control
No Info
No Info
Control module monitoring. Throttle valve not without current; Failure to comply with activation conditions for internal vehicle speed controller
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Malfunction symptoms: No deactivation possible; Speed too low, brake activation, main switch operation
Check speed signal, brake light switch, main cruise control switch. If frequency is >=3 Replace DME
MIL OFF EML OFF CC: Vehicle speed control Vehicle speed controller is rejected
Internal cruise control monitor
0x2D51
11601
Monitoring, air path
ECM Self-Test
HFM
Control module monitoring. Throttle valve not without current; Air mass is implausible relative to injected fuel volume
4 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
4 sec.
none
none
Y
HFM fault or fuel path fault not detected by diagnosis utility, internal control-module fault.
Check air and fuel path. If frequency is > 3 Replace DME.
MIL OFF EML ON CC: Reduced power, engine malfunction RPM limited to 1300 RPM.
Mass airflow monitor
0x2D51
11601
Monitoring, air path
ECM Self-Test
Throttle Valve
Control module monitoring. Throttle valve is not without current; Throttle valve sensor fault not detected by standard diagnosis.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Throttle valve sensor fault not detected by diagnosis, internal control-module fault.
Check throttle-valve potentiometer. At frequency > 3. Replace DME.
MIL OFF. EML ON. CC: Reduced power, engine malfunction RPM limited to 1300 RPM.
TPS sensor monitor
0x2D52
11602
DME, internal fault: monitoring, engine speed
ECM Self-Test
RPM
Control module monitor. Modeled RPM from segment time is compared with crankshaft RPM.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault
If frequency >=3. Replace DME.
MIL OFF. EML ON. CC: Reduced power, engine malfunction RPM limited to 1300 rpm.
RPM monitor
0x2D55
11605
DME, internal fault: monitoring, accelerator-pedal module
ECM Self-Test
Pedal Position Sensor
Control module monitor Comparison PWG sensor voltage above threshold
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
PWG fault not detected by diagnosis, internal control-module fault
If frequency >=3, Replace DME
MIL OFF, EML ON, CC: Reduced power, engine malfunction RPM limited to 1300 rpm.
Accelerator pedal module monitor
0x2D56
11606
DME, internal fault: monitoring, idle air control
ECM Self-Test
Idle Speed Control
Control module monitor. Throttle valve not without current. With I component LL controller implausible or specified LL RPM is too high.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault
If frequency >=3 Replace DME
MIL OFF, EML ON, CC: Reduced power, engine malfunction RPM limited to 1300 RPM.
Idle controller I element monitor
0x2D56
11606
DME, internal fault: monitoring, idle air control
ECM Self-Test
Idle Speed Control
Control module monitor. Throttle valve not without current With PD component LL controller implausible or specified LL RPM is too high.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault
If frequency >=3 Replace DME
MIL OFF, EML ON, CC: Reduced power, engine malfunction RPM limited to 1300 rpm.
Idle controller PD element monitor
0x2D57
11607
DME, internal fault: monitoring, external torque request
No Info
No Info
Control module monitor. Throttle valve not without current. Interface fails to detect implausible torque demand.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Unrecognized implausible torque demand, internal control-module fault.
Check CAN, MSR control module If frequency is >= 3, Replace DME.
MIL OFF, EML OFF, CC: ??? DSC cancelled.
MSR demand monitor
0x2D50
11600
DME, internal fault: monitoring, cruise control
No Info
No Info
Control module monitoring. Throttle valve not without current ACC/DCC initialized; Interface fails to detect implausible torque demand.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Unrecognized implausible torque demand, internal control-module fault
Check CAN, ACC/DCC control module. If frequency is >=3 Replace DME
MIL OFF, EML OFF, CC: Vehicle speed control. Vehicle speed controller is rejected.
ACC/DCC torque demand monitor
0x2D57
11607
DME, internal fault: monitoring, external torque request
No Info
No Info
Control module monitor Interface fails to detect implausible torque demand
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Unrecognized implausible torque demand, internal control-module fault.
Check CAN, SMG control module. If frequency is >= 3 Replace DME.
MIL OFF EML OFF CC: ??? SMG cancelled.
SMG demand monitor
0x2D57
11607
DME, internal fault: monitoring, external torque request
No Info
No Info
Control module monitor. Interface fails to detect implausible torque demand
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Unrecognized implausible torque demand, internal control-module fault
Check CAN, EGS control module If frequency is >=3 Replace DME.
MIL OFF EML OFF CC: ??? EGS cancelled.
EGS demand monitor
0x2D58
11608
DME, internal fault: monitoring, nominal torque
ECM Self-Test
Clutch Torque
Control module monitor. Throttle valve not without current. Calculated maximum clutch torque too high
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault
If frequency >=3 Replace DME
MIL OFF, EML ON, CC: Reduced power, engine malfunction RPM limited to 1300 rpm.
Maximum clutch torque monitor
0x2D58
11608
DME, internal fault: monitoring, nominal torque
ECM Self-Test
Clutch Torque
Control module monitor. Throttle valve not without current. Calculated minimum clutch torque too high.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault
If frequency >=3 Replace DME
MIL OFF, EML ON, CC: Reduced power, engine malfunction RPM limited to 1300 rpm.
Minimum clutch torque monitor
0x2D58
11608
DME, internal fault: monitoring, nominal torque
ECM Self-Test
Torque Loss
Control module monitor. Throttle valve not without current. Calculation fault, calculated torque loss too high.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault, implausible thermal conditions.
Check temperature sensors (oil/coolant). If frequency is >=3 Replace DME.
MIL OFF, EML ON, CC: Reduced power, engine malfunction RPM limited to 1300 rpm.
Torque loss monitor
0x2D58
11608
DME, internal fault: monitoring, nominal torque
ECM Self-Test
Driving Dynamics
Always SPORT switch monitor. Sport switch voltages are not plausible and not detected by diagnosis utility.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault
If frequency >=3 Replace DME
MIL OFF EML ON CC: Reduced power, engine malfunction RPM limited to 1300 rpm
Sport button monitor
0x2D59
11609
DME, internal fault: monitoring, actual torque
ECM Self-Test
Engine Torque
Throttle valve not without current. Driver torque demand is being exceeded.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault, major variation between specified and actual mass airflow
Check mass airflow system (vacuum leaks, VVT, VANOS, throttle valve...). If frequency is >=3 Replace DME
MIL OFF, EML ON, CC: Reduced power, engine malfunction RPM limited to 1300 rpm.
Current induced engine torque monitor
0x2D5A
11610
Monitoring engine torque limiting
No Info
No Info
No interruption of current to throttle valve
Driver torque demand is exceeded => Torque limitation; fault entry after 7s
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
7 sec.
none
none
Y
Internal control-module fault, major variation between specified and actual mass airflow
Check mass airflow system (HFM, vacuum leak, VVT, VANOS, throttle valve...)
MIL OFF, EML OFF, Brief torque restriction.
Limit on current induced engine torque
0x2D53
11603
DME, internal fault: monitoring, engine speed limitation
ECM Self-Test
RPM Limitation
Control module monitor. Currently defined RPM limit is exceeded and injection is still active.
480 ms
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
480 ms
none
none
Y
Internal control-module fault
Replace DME
MIL OFF, EML ON, CC: Reduced power, engine malfunction Reset, RPM limited to 1300 RPM.
RPM governor monitor
0x2ACC
10956
DME master relay, shift delay
ECM/PCM Power Relay
Switching Delay
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2E81
11905
Electrical coolant pump, speed deviation
No Info
No Info
Comparison of specified/actual RPM. No BSD fault.
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
Engine temperature above 20°C
8 sec.
none
none
Y
- Wiring
- Binding
- Problem diagnosis with wiring check
- Plug corrosion
- EWP component fault
CC status report: none EWP fails to reach specified rotation rate
none
0x2E82
11906
Electric coolant pump, cutoff
No Info
No Info
Comparison of specified/actual RPM. No BSD fault
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
10 sec.
none
none
Y
EWP component fault
EWP component fault
CC status report: none EWP not operating. Heat management initiates emergency cooling action
none
0x2E83
11907
Electric coolant pump, power-reduced operation
No Info
No Info
Comparison of specified/actual RPM. No BSD fault
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
10 sec.
none
none
Y
Air in system
Bleed cooling system/leak check
CC status report: None Limit on EWP rotation rate
none
0x2E82
11906
Electric coolant pump, cutoff
No Info
No Info
Comparison of specified/actual RPM. No BSD fault
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
10 sec.
none
none
N
Jump start with truck battery
Clear fault memory or, if fault is permanent, replace EWP components without jump starting.
CC status report. No EWP inoperative during power supply. Heat management initiates emergency cooling action.
none
0x2E83
11907
Electric coolant pump, power-reduced operation
No Info
No Info
Comparison of specified/actual RPM. No BSD fault
10 sec.
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
10 sec.
none
none
N
- Wiring
- Battery charge status
- Charge battery
- Problem diagnosis with wiring check
- Plug corrosion
- Component fault in EWP
CC status report: none. EWP fails to reach specified rotation rate.
none
0x2E83
11907
Electric coolant pump, power-reduced operation
No Info
No Info
Comparison of specified/actual RPM. No BSD fault
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
10 sec.
none
none
Y
EWP component fault
EWP component fault
CC status report: None Limit on EWP rotation rate
none
0x2E85
11909
Electric coolant pump, communication
No Info
No Info
Compare EWP status report with main relay activation. No BSD fault.
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
10 sec.
none
none
N
Terminal 87 to EWP shorted to positive or ground, or open
Problem diagnosis wiring check
CC status report: none. EWP runs based on BSD request.
none
0x2E7C
11900
Bit-serial data interface, signal
No Info
No Info
BSD bus monitor
Via event counter. Total failure between BSD bus and all components (water pump, oil sensor, alternator, battery sensor over approximately 3 sec.
Terminal 15 ON
Terminal 87 >10.0 V
none
approximately 3 sec.
none
none
N
Short circuit on the BSD_BUS. Either to ground or positive, rendering communications impossible. Or no BSD_components connected to the DME.
- Disconnect all BSD_components (alternator, battery sensor, water pump) except for the oil sensor. Clear fault memory. Ignition off/on. If fault code is stored again: QLT is defective and must be replaced. Repeat test.
- If fault code is entered again after QLT replacement: -> Check wiring harness (BSD_BUS) and all plug-in connections for corrosion and shorts to ground/UBatt.
- If fault code no longer appears after QLT replacement: -> QLT was defective.
- If no fault code is stored after all components (except QLT, as in 1.) are disconnected: -> The fault lies with one of the
No oil level display/no oil temperature display available. Service interval calculations for next visit are based on model. Water pump runs at 100% cooling capacity and draws continuous current of approximately 15A. Power management fails to operate correctly because it is not possible to read battery sensor.
ATTENTION: Simply switching the ignition on/off is enough for problem diagnosis. Because the water pump may not be connected, and the engine could overheat, you should avoid starting the engine. Fault status can be reset by clearing fault memory.
0x2E82
11906
Electric coolant pump, cutoff
No Info
No Info
Comparison of specified/actual rpm. No BSD fault.
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
10 sec.
none
none
Y
Contamination, Binding, Incorrect coolant mixture ratio.
Respond to intermittent fault by triggering actuators for operational test and by checking concentration of coolant. Permanent fault indicates foreign objects or EWP component fault.
CC status report none EWP briefly/continuously without function. Heat management initiates emergency cooling strategy.
none
0x2E83
11907
Electric coolant pump, power-reduced operation
No Info
No Info
Comparison of specified/actual RPM. No BSD fault.
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
10 sec.
none
none
Y
EWP component fault
EWP component fault
CC status report: None. Limit on EWP rotation rate.
none
0x2E84
11908
Electric coolant pump, communication
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2DE0
11744
No message from electric fuel pump
No Info
No Info
EKP recognized
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
40 sec.
none
none
N
Unable to receive CAN message.
Check CAN link between EKP and DME
none
Timeout on CAN message
0x2DE1
11745
Tank fill level, left, signal
Fuel Level Sensor
Electrical
Left-side level sensor shorted, sensor resistance too low.
90 sec.
Terminal 15, engine on
none
none
none
none
none
N
Sensor value too low
Check sensor resistance, determine location of open wire/short circuit (wiring harness, plug, cluster, junction box, tank)
NO
none
0x2DE1
11745
Tank fill level, left, signal
Fuel Level Sensor
Electrical
Open circuit in wire to left-side level sensor, sensor resistance too high.
90 sec.
Terminal 15, engine on
none
none
none
none
none
N
Sensor value too high
Check sensor resistance, determine location of open wire/short circuit (wiring harness, plug, cluster, junction box, tank)
NO
none
0x2A80
10880
Intake VANOS, activation
Camshaft Position Actuator
Intake
Monitoring of VANOS control Engine. speed > 500 rpm
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
none
N
Short circuit to ground in wire or component.
Check wiring, repair if defective. If wiring is OK, proceed to check component.
MIL ON
none
0x2A80
10880
Intake VANOS, activation
Camshaft Position Actuator
Intake
Monitoring of VANOS control, Engine speed > 500 rpm
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
none
N
Wire is shorted to positive, or a short to positive is present in the component.
Check wiring. Repair if defective. If wiring is OK, proceed to check component
MIL ON
none
0x2A85
10885
Exhaust VANOS, activation
Camshaft Position Actuator
Exhaust
Monitoring of VANOS control. Engine speed > 500 rpm.
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
none
N
Short circuit to ground in wire or component.
Check wiring. Repair if defective. If wiring is OK, proceed to check component.
MIL ON
none
0x2A85
10885
Exhaust VANOS, activation
Camshaft Position Actuator
Exhaust
Monitoring of VANOS control Engine speed > 500 rpm
none
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
0.5 sec.
none
none
N
Wire is shorted to positive, or a short to positive is present in the component.
Check wiring. Repair if defective. If wiring is OK proceed to check component.
MIL ON
none
0x2C31
11313
Oxygen sensor before catalytic converter, trim control
Fuel System
Post Catalyst
O2 sensor trim control. No fault memories. Drive at 50 - 80 km/h and at moderate engine speed..
Trim controller pegged
Terminal 15, engine on
none
Engine at operating temperature
1 - 2 h steady-state operation; otherwise #11390 may occur
none
none
N
Defective wiring. Exhaust system leak. Pre-cat or downstream (post-cat) O2 sensor defective.
This malfunction automatically triggers an active test (collateral fault stored in the control module's fault memory!).
- Read out results of active test (are other faults still stored in the control module's fault memory)? => Then continue at this point!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then
- Visual inspection of wiring and plugs
- Electrical check of wiring
- Replace wiring or plugs as indicated
- Check exhaust system forward of downstream (post-cat) O2 sensor for leaks
- Replace upstream (pre-cat) O2 sensor
MIL ON
none
0x2C31
11313
Oxygen sensor before catalytic converter, trim control
Fuel System
Post Catalyst
O2 sensor trim control. No fault memories. Drive at 50 - 80 km/h and at moderate engine speed.
Trim controller pegged
Terminal 15, engine on
none
Engine at operating temperature
1 - 2 h steady-state operation; otherwise #11390 may occur
none
none
N
Drift in upsteam (pre-cat) O2 sensor - Fault in wiring to downstream (post-cat) O2 sensor - Leakage in exhaust system - Defective pre-cat or downstream (post-cat) O2 sensor
This malfunction automatically triggers an active test (collateral fault stored in the control module's fault memory!).
- Read out results of active test (are other faults still stored in the control module's fault memory)? => Then continue at this point!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then
- Visual inspection of wiring and plugs
- Electrical check of wiring
- Replace wiring or plugs as indicated
- Check exhaust system forward of downstream (post-cat) O2 sensor for leaks
- Replace upstream (pre-cat) O2 sensor
MIL ON
none
0x2C32
11314
Oxygen sensor before catalytic converter 2, trim control
Fuel System
Post Catalyst
O2 sensor trim control No fault memories Drive at 50 - 80 km/h and at moderate engine speed.
Trim controller pegged
Terminal 15, engine on
none
Engine at operating temperature
1 - 2 h steady-state operation; otherwise #11391 may occur
none
none
N
Defective wiring. Exhaust system leak. Pre-cat or downstream (post-cat) O2 sensor defective.
This malfunction automatically triggers an active test (collateral fault stored in the control module's fault memory!).
- Read out results of active test (are other faults still stored in the control module's fault memory)? => Then continue at this point!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then
- Visual inspection of wiring and plugs
- Electrical check of wiring
- Replace wiring or plugs as indicated
- Check exhaust system forward of downstream (post-cat) O2 sensor for leaks
- Replace upstream (pre-cat) O2 sensor
MIL ON
none
0x2C32
11314
Oxygen sensor before catalytic converter 2, trim control
Fuel System
Post Catalyst
O2 sensor trim control. No fault memories. Drive at 50 - 80 km/h and at moderate engine speed.
Trim controller pegged
Terminal 15, engine on
none
Engine at operating temperature
1 - 2 h steady-state operation; otherwise #11391 may occur
none
none
N
Defective wiring. Exhaust system leak. Pre-cat or downstream (post-cat) O2 sensor defective.
This malfunction automatically triggers an active test (collateral fault stored in the control module's fault memory!).
- Read out results of active test (are other faults still stored in the control module's fault memory)? => Then continue at this point!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then
- Visual inspection of wiring and plugs
- Electrical check of wiring
- Replace wiring or plugs as indicated
- Check exhaust system forward of downstream (post-cat) O2 sensor for leaks
- Replace upstream (pre-cat) O2 sensor
MIL ON
none
0x2D1F
11551
Accelerator-pedal module, pedal-position sensor potentiometer, signal
Pedal Position Sensor
D Electrical
Pedal-position sensor monitor
0.02 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
220 ms
none
none
N
Dual fault in pedal-position sensor
- Read out the two root faults from the control module's fault memory
- Process using prescribed test plan
- Check main relay and overall vehicle electrical system voltage supply
- Replace DME
CC status report: Reduced engine power! EML ON, MIL ON, PW = 0, fast idle when brake pedal is not depressed.
Pedal reading 0, slightly high idle if brake pedal is not depressed
0x2D1B
11547
Accelerator pedal module, pedal-position sensor, signal 1
Pedal Position Sensor
D Electrical
Pedal-position sensor monitor. No fault code currently registered.
0.02 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
240 ms
none
none
N
Sensor wire shorted to ground or open circuit in wire
- Perform electrical check on sensor wire and power-supply wires
- Visual inspection of plug-in contacts (on component and DME ends)
- Replace PWG
CC status report: ??? EML ON, restricted PW gradient, and PW limit via rpm.
Voltage range diagnosis
0x2D1B
11547
Accelerator pedal module, pedal-position sensor, signal 1
Pedal Position Sensor
D Electrical
Pedal-position sensor monitor. No fault code currently registered
0.02 sec.
Terminal 15 ON
Voltage in onboard electrical system > = 10 V
none
240 ms
none
none
N
Sensor wire shorted to positive
- Perform electrical check on sensor wire and power-supply wires
- Visual inspection of plug-in contacts (on component and DME ends)
- Replace PWG
CC status report: Reduced engine power! EML ON restricted PW gradient and PW limit via rpm
Voltage range diagnosis
0x2D1C
11548
Accelerator pedal module, pedal-position sensor, signal 2
Pedal Position Sensor
E Electrical
Pedal-position sensor monitor. No fault code currently registered.
0.02 sec.
Terminal 15 ON
Voltage in onboard electrical system > = 10 V
none
240 ms
none
none
N
Sensor wire shorted to ground or open circuit in wire.
- Perform electrical check on sensor wire and power-supply wires
- Visual inspection of plug-in contacts (on component and DME ends)
- Replace PWG
CC status report: Reduced engine power! EML ON restricted PW gradient and PW limit via rpm.
Voltage range diagnosis
0x2D1C
11548
Accelerator pedal module, pedal-position sensor, signal 2
Pedal Position Sensor
E Electrical
Pedal-position sensor monitor. No fault code currently registered
0.02 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
240 ms
none
none
N
Sensor wire shorted to positive
- Perform electrical check on sensor wire and power-supply wires.
- Visual inspection of plug-in contacts (on component and DME ends).
- Replace PWG.
CC status report: Reduced engine power! EML ON, restricted PW gradient, and PW limit via RPM.
Voltage range diagnosis
0x2D20
11552
Accelerator-pedal module, pedal-position sensor, plausibility between signal 1 and signal 2
Pedal Position Sensor
D/E Correlation
Pedal-position sensor monitor
0.02 sec.
Terminal 15 ON
Voltage in onboard electrical system >= 10 V
none
340 ms
none
none
N
Contact resistance in wiring or plug-in connections for PWG, electrical PWG problem (defective Hall-effect sensor).
- Check: Pedal-position sensor voltages [Pot voltage 2 = (Pot voltage1)/2]
- Check wires from DME to PWG
- Visual inspection of plug terminals (on components, wiring harness and DME)
- Replace PWG
CC status report: Reduced engine power! EML ON restricted PW gradient and PW limit via rpm.
Implausible spread between the two PWG voltages.
0x2AAD
10925
Fuel pump, emergency shutoff
Fuel Regulators/Valves/Sensors
Fuel Pump
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2EEC
12012
Temperature sensor cooler outlet, plausibility
Engine Coolant Temperature Sensor
2 Plausibility
Engine must be running
no invariable debounce time, constant sensor data reading during engine warm-up produces entry
Terminal 15 ON
11 V < electrical system voltage < 26 V
10°C < Coolant temperature at engine start < 65°C, -10°C < Induction air temperature at engine start < 69°C
600 ms
none
none
N
Temperature sensor seizing, sensor manipulation
- Visual inspection of sensor
- Perform electrical check on sensor and power-supply wires 2) Test to determine whether the temperature really changes when the thermostat opens
- Replace sensor
MIL ON in US versions only
temperature condition defined by data entry
0x2EEA
12010
Temperature sensor cooler outlet, signal
Engine Coolant Temperature Sensor
2 Electrical
Radiator discharge temperature signal monitor
5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9.15 V
none
5 sec.
none
none
N
Short to ground in sensor wire
- Perform electrical check on sensor wire and power-supply wires
- Visual inspection of plug-in contacts (on component and DME ends)
- Replace sensor
MIL ON in US versions only
Voltage range diagnosis
0x2EEA
12010
Temperature sensor cooler outlet, signal
Engine Coolant Temperature Sensor
2 Electrical
Radiator discharge temperature signal monitor
No compliance with temperature condition and time after end of start > 120 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9.15 V
Intake air temperature >= -5.25°C OR if less than -5.25°C, then time after end of start phase > 120 sec.
No compliance with temperature condition and time after end of start >120 sec.
none
none
N
Sensor wire shorted to positive or open circuit in wire
- Perform electrical check on sensor wire and power-supply wires
- Visual inspection of plug-in contacts (on component and DME ends)
- Replace sensor
MIL ON in US versions only
Voltage range diagnosis
0x2C27
11303
Oxygen sensor before catalytic converter, system check
Oxygen Sensor, Front
Signal Check
After trim control fault; sensor indicates more than 18% too lean
Terminal 15, engine on
none
none
Approximately 300s after trim control fault
none
none
none
Y
Sensor contamination, hole in sensor, short circuit to positive or ground
Check sensor wiring for short circuit; otherwise replace the suspect sensor.
MIL ON
none
0x2C2B
11307
Oxygen sensor before catalytic converter, system check
Oxygen Sensor, Front
Signal Check
After trim control fault; sensor indicates more than 18% too rich
Terminal 15, engine on
none
none
Approximately 300s after trim control fault
none
none
none
Y
Hole in sensor, short circuit to positive or ground
Check sensor wiring for short circuit; otherwise replace the suspect sensor
MIL ON
none
0x2C28
11304
Oxygen sensor before catalytic converter 2, system check
Oxygen Sensor, Front
Signal Check
After trim control fault; sensor indicates more than 18% too lean.
Terminal 15, engine on
none
none
Approximately 300s after trim control fault
none
none
none
Y
Sensor contamination, hole in sensor, short circuit to positive or ground
Check sensor wiring for short circuit; otherwise replace the suspect sensor
MIL ON
none
0x2C2C
11308
Oxygen sensor before catalytic converter 2, system check
Oxygen Sensor, Front
Signal Check
Oxygen sensor before catalytic converter 2, system check End of start phase O2 sensor drifts toward rich
After trim control fault; sensor indicates more than 18% too rich
Terminal 15, engine on
none
none
Approximately 300s after trim control fault
none
none
Y
Hole in sensor, short circuit to positive or ground
Check sensor wiring for short circuit; otherwise replace the suspect sensor
MIL ON
none
0x2F76
12150
Ambient-pressure sensor, signal
Ambient Pressure Sensor
Electrical
Ambient pressure sensor signal monitor
0.5 sec.
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
500 ms
none
none
N
Short-circuit with respect to ground
Replace DME; this is an internal component
MIL on
none
0x2F76
12150
Ambient-pressure sensor, signal
Ambient Pressure Sensor
Electrical
Ambient pressure sensor signal monitor
0.5 sec.
Terminal 15, engine on
Voltage in onboard electrical system > 10 V
none
500 ms
none
none
N
Short to positive or open circuit
Replace DME; this is an internal component
MIL on
none
0x2C3D
11325
Oxygen sensor before catalytic converter, line fault
Oxygen Sensor, Front
Reference Voltage
O2 sensor wiring monitor (heater) O2 sensor temperature is too low and the sensor signal is implausible No fault memories
Sensor temperature < 680°C and sensor voltage < 0.2 V with oscillator deactivated
Terminal 15, engine on
none
Engine at operating temperature
approximately 15 sec.
none
none
N
Sensor not active - Open UN wire
- Visual inspection of wires, DME plug and O2 sensor for damage
- Inspect wires
- Check plug-in connections DME <=> Wiring harness <=> Upstream (pre-cat) O2 sensor for Bank 1 (water or corrosion in plug?) => Repeatedly disconnect the plug and then FIRMLY press it back in)
- Replace O2 sensor
- Replace DME
MIL ON
none
0x2C3E
11326
Oxygen sensor before catalytic converter 2, line fault
Oxygen Sensor, Front
Reference Voltage
O2 sensor wiring monitor O2 sensor signal freezes. No fault memories - Drive at 50 - 80 km/h at moderate engine speed
Voltage seizes at 2 V (Lambda = 1) OR voltage < 2.1 V with overrun injection deactivation active
Terminal 15, engine on
none
Engine at operating temperature
approximately 9s with overrun injection deactivation active
O2 sensors reversed
none
N
Sensor inactive Wire VG or IP is open Catalyst is plugged (rich exhaust at O2 sensor in overrun cut-off); oil or gasoline in the exhaust gases during operation in overrun cut-off phase
- Visual inspection of wires, DME plug and O2 sensor for damage
- Inspect wires
- Check plug-in connections DME <=> Wiring harness <=> Upstream (pre-cat) O2 sensor for Bank 1 (water or corrosion in plug?) => Repeatedly remove the plug and then reconnect it FIRMLY)
- Check catalytic converter (is FSD lean fault entered for the other bank?)
- Piston rings, injectors, positive crankcase ventilation OK? FSD fault? Then continue there!
- Replace O2 sensor
- Replace DME
MIL ON
none
0x2C6B
11371
Oxygen sensor behind catalytic converter, system check
Oxygen Sensor, Rear
Signal Check
O2 sensor system check O2 sensor voltage too high = Signal sticks at rich Trim controller diagnosis must have been executed, see Trim controller diagnosis. Detection of malfunctions during the trim control diagnosis triggers the active test. Engine running at idle is adequate for the active test
O2 sensor behind catalytic converter voltage > 0.7 V with lean O2 data specification in active test
Terminal 15, engine on
none
Engine at operating temperature
roughly 300 s following completion of trim control diagnosis
O2 sensors reversed
none
N
Downstream (post-cat) O2 sensor aged or downstream (post-cat) O2 sensor poisoned or downstream (post-cat) O2 sensor wire defective, pegging trim controller -> Trim controller diagnosis entry -> Activation of active test, entry of fault code #11371
This malfunction is detected during the active test. The active test is triggered by the trim control diagnosis function (trim controller fault code stored in the control module's fault memory!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then
- Visual inspection of wiring and plugs
- Electrical check of wiring
- Replace wires or plugs as indicated
- Check exhaust system upstream from downstream (post-cat) O2 sensor for leaks
- Replace downstream (post-cat) O2 sensor
- Replace upstream (pre-cat) O2 sensor
none
none
0x2C6B
11371
Oxygen sensor behind catalytic converter, system check
Oxygen Sensor, Rear
Signal Check
O2 sensor system check O2 sensor voltage too low = Signal sticks on lean Trim controller diagnosis must have been executed, see Trim controller diagnosis. Detection of faults during the trim control diagnosis triggers the active test. Engine running at idle is adequate for the active test.
O2 sensor behind catalytic converter voltage < 0.2 V with rich data specification for active test
Terminal 15, engine on
none
Engine at operating temperature
roughly 300 s following completion of trim control diagnosis
O2 sensors reversed
none
N
Downstream (post-cat) O2 sensor aged or downstream (post-cat) O2 sensor poisoned or downstream (post-cat) O2 sensor wire defective or exhaust system forward of downstream (post-cat) O2 sensor is leaking, pegging trim controller -> Trim controller diagnosis entry -> Activation of active test, entry of fault code #11371
This malfunction is detected during the active test. The active test is triggered by the trim control diagnosis function (trim controller fault code stored in the control module's fault memory!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then
- Visual inspection of wiring and plugs
- Electrical check of wiring
- Replace wires or plugs as indicated
- Check exhaust system upstream from downstream (post-cat) O2 sensor for leaks
- Replace downstream (post-cat) O2 sensor
- Replace upstream (pre-cat) O2 sensor
MIL ON
none
0x2C6C
11372
Oxygen sensor behind catalytic converter 2, system check
Oxygen Sensor, Rear
Signal Check
O2 sensor system check O2 sensor voltage too high = Signal sticks at rich Trim controller diagnosis must have been executed, see Trim controller diagnosis. Detection of malfunctions during the trim control diagnosis triggers the active test. Engine running at idle is adequate for the active test
O2 sensor behind catalytic converter voltage > 0.7 V with lean O2 data specification in active test
Terminal 15, engine on
none
Engine at operating temperature
roughly 300s following completion of trim control diagnosis
O2 sensors reversed
none
N
Downstream (post-cat) O2 sensor aged or downstream (post-cat) O2 sensor poisoned or downstream (post-cat) O2 sensor wire defective, pegging trim controller at limit -> Trim controller diagnosis entry -> Activation of active test, entry of fault code #11372
This malfunction is detected during the active test. The active test is triggered by the trim control diagnosis function (trim controller fault code stored in the control module's fault memory!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then
- Visual inspection of wiring and plugs
- Electrical check of wiring
- Replace wires or plugs as indicated
- Check exhaust system upstream from downstream (post-cat) O2 sensor for leaks
- Replace downstream (post-cat) O2 sensor
- Replace upstream (pre-cat) O2 sensor
none
none
0x2C6C
11372
Oxygen sensor behind catalytic converter 2, system check
Oxygen Sensor, Rear
Signal Check
O2 sensor system check O2 sensor voltage too low = Signal sticks on lean - Trim controller diagnosis must have been executed, see Trim controller diagnosis. Detection of faults during the trim control diagnosis triggers the active test. Engine running at idle is adequate for the active test
O2 sensor behind catalytic converter voltage < 0.2 V with rich data specification for active test
Terminal 15, engine on
none
Engine at operating temperature
roughly 300s following completion of trim control diagnosis
O2 sensors reversed
none
N
Downstream (post-cat) O2 sensor aged or downstream (post-cat) O2 sensor poisoned or downstream (post-cat) O2 sensor wire defective or exhaust system forward of cat-back O2 sensor is leaking, pegging trim controller -> Trim controller diagnosis entry -> Activation of active test, entry of fault code #11372
This malfunction is detected during the active test. The active test is triggered by the trim control diagnosis function (trim controller fault code stored in the control module's fault memory!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then
- Visual inspection of wiring and plugs
- Electrical check of wiring
- Replace wires or plugs as indicated
- Check exhaust system upstream from downstream (post-cat) O2 sensor for leaks
- Replace downstream (post-cat) O2 sensor
- Replace upstream (pre-cat) O2 sensor
MIL ON
none
0x2C2D
11309
Oxygen sensor before catalytic converter, overrun check
Oxygen Sensor, Front
Deceleration
Implausible O2 sensor signal in overrun cutoff phase, no fault memories
Bank 1 O2 sensor before catalytic converter voltage less than 3.1 V or greater than 2.1 V with overrun injection deactivation active
Terminal 15, engine on
none
Engine warm (exhaust-gas temperature > 380°C)
approximately 9 sec. with overrun cutoff active
none
none
N
Catalytic converter obstructed (rich exhaust gas on O2 sensor during overrun cutoff); oil or gasoline in exhaust gas during overrun cutoff; defective wiring; Defective pre-cat O2 sensor
- Visual inspection of wiring and plugs (water or corrosion in plug?) Repeatedly remove the plug and then FIRMLY insert it again
- Electrical check of wiring
- Check catalytic converter (FSD lean fault may be entered for the other bank)
- Piston rings, injector valves, positive crankcase ventilation OK? FSD fault? Then continue there!
- Replace wires or plugs on O2 sensors as indicated
- Replace O2 sensor
MIL ON
none
0x2C2E
11310
Oxygen sensor before catalytic converter 2, overrun check
Oxygen Sensor, Front
Deceleration
Implausible O2 sensor signal in overrun cutoff phase, no fault memories
Bank 2 O2 sensor before catalytic converter voltage less than 3.1 V or greater than 2.1 V with overrun injection deactivation active
Terminal 15, engine on
none
Engine warm (exhaust-gas temperature > 380°C)
approximately 9 sec. with overrun cutoff active
none
none
N
Catalytic converter obstructed (rich exhaust gas on O2 sensor during overrun cutoff); oil or gasoline in exhaust gas during overrun cutoff; defective wiring; Defective pre-cat O2 sensor
- Visual inspection of wiring and plugs (water or corrosion in plug?) Repeatedly remove the plug and then FIRMLY insert it again
- Electrical check of wiring
- Check catalytic converter (FSD lean fault may be entered for the other bank)
- Piston rings, injector valves, positive crankcase ventilation OK? FSD fault? Then continue there!
- Replace wires or plugs on O2 sensors as indicated
- Replace O2 sensor
MIL ON
none
0x2F8F
12175
Accelerator pedal module and brake pedal, plausibility
No Info
No Info
Accelerator pedal module and brake pedal plausibility monitor
1.5 sec.
Terminal 15 ON
none
none
none
none
none
N
Continuous simultaneous pressure on accelerator and brake, seizing accelerator pedal
- Discuss driving habits with customer (driving with both feet)
- Visual and operational check on PWG
none
Can lead to substantial reductions in vehicle throttle response
0x2A13
10771
DMTL leak diagnosis pump, activation
EVAP System
Pump
Monitoring of control activation when pump is triggered
0.5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
DMTL Check
none
N
Open circuit
Check wiring - Repair if defective - If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2A13
10771
DMTL leak diagnosis pump, activation
EVAP System
Pump
Monitoring of control activation when pump is triggered
0.5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
DMTL Check
none
N
Short to ground
Check wiring - Repair if defective - If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2A13
10771
DMTL leak diagnosis pump, activation
EVAP System
Pump
Monitoring of control activation when pump is triggered
0.5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
DMTL Check
none
N
Short to positive
Check wiring - Repair if defective - If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2A18
10776
DMTL, heater: activation
EVAP System
DMTL Heater
Control monitoring when DMTL heater is being triggered.
5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
5 sec.
DMTL Check
none
N
Open circuit
Check wiring - Repair if defective - If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2A18
10776
DMTL, heater: activation
EVAP System
DMTL Heater
Control monitoring when DMTL heater is being triggered.
5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
5 sec.
DMTL Check
none
N
Short to ground
Check wiring - Repair if defective - If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2A18
10776
DMTL, heater: activation
EVAP System
DMTL Heater
Control monitoring when DMTL heater is being triggered.
5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
5 sec.
DMTL Check
none
N
Short to positive
Check wiring - Repair if defective - If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2C3B
11323
Oxygen sensor before catalytic converter, not connected
Oxygen Sensor, Front
Exhaust Sample Error
O2 sensor test O2 sensor indicates lean mixture although engine operates at part or full load
O2 sensor voltage >4.8 V at part-load (sensor registers air)
Terminal 15, engine on
none
none
25 sec.
none
none
N
O2 sensor not screwed in
Determine whether sensor is corrected threaded into place - Check exhaust system for leaks - Check the plug-in connection
MIL ON
none
0x2C3C
11324
Oxygen sensor before catalytic converter 2, not connected
Oxygen Sensor, Front
Exhaust Sample Error
O2 sensor test O2 sensor indicates lean mixture although engine operates at part or full load
O2 sensor voltage >4.8 V at part-load (sensor registers air)
Terminal 15, engine on
none
none
25 sec.
none
none
N
O2 sensor not screwed in
Determine whether sensor is corrected threaded into place Check exhaust system for leaks Check the plug-in connection
MIL ON
none
0x2A12
10770
DMTL solenoid valve, activation
EVAP System
Switching Valve
Monitoring of control activation when solenoid is triggered
0.5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
DMTL Check
none
N
Open circuit
Check wiring - Repair if defective - If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2A12
10770
DMTL solenoid valve, activation
EVAP System
Switching Valve
Monitoring of control activation when solenoid is triggered
0.5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
DMTL Check
none
N
Short to ground
1Check wiring Repair if defective If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2A12
10770
DMTL solenoid valve, activation
EVAP System
Switching Valve
Monitoring of control activation when solenoid is triggered
0.5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
0.5 sec.
DMTL Check
none
N
Short to positive
1Check wiring Repair if defective If wiring is OK proceed to check component
MIL ON
Installed in US only (initialization version)
0x2F9E
12190
Thermal oil-level sensor
Engine Oil Level Sensor
Electrical
No communications with sensor
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9 V
none
none
none
none
N
Defective oil sensor (no communications)
Wiring harness check/sensor replacement
CC message 182 - suppressed starting with E90 with BN2000
not used
0x2F9E
12190
Thermal oil-level sensor
Engine Oil Level Sensor
Plausibility
Implausible sensor signal
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9 V
none
none
none
none
N
Interference in oil sensor signal
Wiring harness check/sensor replacement
CC message 182 - suppressed starting with E90 with BN2000
not used
0x2F9E
12190
Thermal oil-level sensor
Engine Oil Level
Level
Oil level below 5 liters
10 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9 V
Oil temperature > 0
none
none
none
N
Oil level too low (substantially below MIN)
Add 1l engine oil
CC message 28
not used
0x2EC2
11970
LIN bus, communication
No Info
No Info
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME
2.4 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
none
- Incident electromagnetic radiation
- Internal driver chip in DME defective
- Check routing of wiring and exclude electromagnetic interference problem as possible cause
- Replace DME
none
none
0x2EC2
11970
LIN bus, communication
No Info
No Info
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME
2.4 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
none
- Incident electromagnetic radiation
- Internal driver chip in DME defective
- Check routing of wiring and exclude electromagnetic interference problem as possible cause
- Replace DME
none
none
0x2EA1
11937
Oil condition sensor, communication
Engine Oil Quality Sensor
Electrical
Oil status sensor communications monitor
20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 9 V
none
approximately 10 sec.
none
none
N
- Oil sensor (BSD BUS) not connected
- Open wire (BSD BUS) between oil sensor and DME
- Defective oil sensor
- Check wire (BSD_BUS) connecting oil sensor (QLT) and DME.
- Check plug-in connection at QLT.
- Replace QLT
No warning message. No oil level display or oil temperature measurement is possible without the BSD_BUS signal.
none
0x2EC2
11970
LIN bus, communication
No Info
No Info
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME
2.4 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
none
- Incident electromagnetic radiation
- Internal driver chip in DME defective
- Check routing of wiring and exclude electromagnetic interference problem as possible cause
- Replace DME
none
none
0x2ADA
10970
EAC sensor, electrical fault
Direct Ozone Reduction
Catalyst Temperature Sensor
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME
2.5 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
none
Fault in temperature measurement within sensor
Replace EAC sensor
MIL in second driving cycle
none
0x2ADA
10970
EAC sensor, electrical fault
Direct Ozone Reduction
Catalyst Temperature Sensor
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME.
2.5 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
none
Short to ground
Replace EAC sensor
MIL in second driving cycle
none
0x2ADA
10970
EAC sensor, electrical fault
Direct Ozone Reduction
Catalyst Temperature Sensor
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME.
2.5 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
none
Short to positive
Replace EAC sensor
MIL in second driving cycle
none
0x2C3D
11325
Oxygen sensor before catalytic converter, line fault
Oxygen Sensor, Front
Pumping Current
O2 sensor wire monitoring. Voltage of O2 sensor signal is too high during overrun cut-off phase, overrun injection deactivation.
Voltage >5.8 V during overrun injection deactivation
Terminal 15, engine on
none
Engine at operating temperature.
approximately 9s with overrun injection deactivation active
O2 sensors reversed
none
N
Sensor inactive. Wire IA is open. Catalyst is plugged (rich exhaust at O2 sensor in overrun cut-off); oil or gasoline in the exhaust gases during operation in overrun cut-off phase.
- Visual inspection of wires, DME plug and O2 sensor for damage
- Inspect wires
- Check plug-in connections DME <=> Wiring harness <=> Upstream (pre-cat) O2 sensor for Bank 1 (water or corrosion in plug?) => Repeatedly remove the plug and then reconnect it FIRMLY)
- Check catalytic converter (is FSD lean fault entered for the other bank?)
- Piston rings, injectors, positive crankcase ventilation OK? FSD fault? Then continue there!
- Replace O2 sensor
- Replace DME
MIL ON
none
0x2C3E
11326
Oxygen sensor before catalytic converter 2, line fault
Oxygen Sensor, Front
Pumping Current
O2 sensor wire monitoring. Voltage of O2 sensor signal is too high during overrun cut-off phase, overrun injection deactivation
Voltage > 5.8 V during overrun injection deactivation
Terminal 15, engine on
none
Engine at operating temperature
approximately 9s with overrun injection deactivation active
O2 sensors reversed
none
N
Sensor inactive Wire IA is open Catalyst is plugged (rich exhaust at O2 sensor in overrun cut-off); oil or gasoline in the exhaust gases during operation in overrun cut-off phase
- Visual inspection of wires, DME plug and O2 sensor for damage.
- Inspect wires
- Check plug-in connections DME <=> Wiring harness <=> Upstream (pre-cat) O2 sensor for Bank 1 (water or corrosion in plug?) => Repeatedly remove the plug and then reconnect it FIRMLY)
- Check catalytic converter (is FSD lean fault entered for the other bank?)
- Piston rings, injectors, positive crankcase ventilation OK? FSD fault? Then continue there!
- Replace O2 sensor
- Replace DME
MIL ON
none
0x2F0D
12045
Radiator blind, activation, (GLF)
No Info
No Info
AKKS must be initialized.
up to 20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
In the SGBD
PWM of 5-90%
N
- Wire from the DME to the AKKS is shorted to UBatt. PVE: Connect wire from DME to AKKS to UBatt.
- Check wire from the DME to the AKKS.
no external display
There is no hazard provided that the voltage supply to the AKKS is OK. (Failsafe circuit in the AKKS is active: both flaps remain open.)
0x2F0D
12045
Radiator blind, activation, (GLF)
No Info
No Info
AKKS must be initialized.
up to 20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
No info.
PWM of 5-90%
N
- Wire from the DME to the AKKS is shorted to ground.
- No voltage supply to the AKKS. PVE: Ground the wire from the DME to the AKKS.
- Determine whether a possible self-diagnosis fault at the AKKS or PKKS is stored as an fault in the fault memory. (If yes, start by repairing this.)
- Check wire from the DME to the AKKS
- Check voltage supply at the AKKS
no external display
There is no hazard provided that the voltage supply to the AKKS is OK. (Failsafe circuit in the AKKS is active: both flaps remain open.)
0x2F0D
12045
Radiator blind, activation, (GLF)
No Info
No Info
AKKS must be initialized.
up to 20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
No info.
PWM of 5-90%
N
- Wire from the DME to the AKKS is open. PVE: Open the wire from the DME to the AKKS.
- Check wire from the DME to the AKKS.
no external display
There is no hazard provided that the voltage supply to the AKKS is OK. (Fail-safe circuit in the AKKS is active: both flaps remain open.)
0x2C41
11329
DME, internal fault: oxygen sensor
Oxygen Sensor, Front
ECM Self-Test
Monitoring of O2 sensor chip. No fault memories.
Self-diagnosis processor chip: Communications fault with $mUC.
Terminal 15 ON
none
none
approximately 5 sec.
none
none
N
Communication fault between processor chip and microcontroller.
Replace DME
MIL ON
none
0x2C42
11330
DME, internal fault: oxygen sensor 2
Oxygen Sensor, Front
ECM Self-Test
Monitoring of O2 sensor chip. No fault memories.
Self-diagnosis processor chip: Communications fault with $mUC.
Terminal 15 ON
none
none
approximately 5 sec.
none
none
N
Communication fault between processor chip and microcontroller.
Replace DME
MIL ON
none
0x2C41
11329
DME, internal fault: oxygen sensor
Oxygen Sensor, Front
ECM Self-Test
Monitoring of O2 sensor chip. No fault memories.
Self-diagnosis processor chip: Communications fault with $mUC
Terminal 15 ON
none
none
approximately 100 sec.
none
none
N
Initialization fault
Replace DME
MIL ON
none
0x2C42
11330
DME, internal fault: oxygen sensor 2.
Oxygen Sensor, Front
ECM Self-Test
Monitoring of O2 sensor chip. No fault memories.
Self-diagnosis processor chip: Communications fault with $mUC
Terminal 15 ON
none
none
approximately 100 sec.
none
none
N
Initialization fault
Replace DME
MIL ON
none
0x2EE6
12006
Coolant-temperature sensor, measurement range
Engine Coolant
Temperature
Engine must be running, T_ES > 360 min, UBatt > 11 V, TIA at start between - 10°C and 60°C, TAM_ST > -10°C, cold start
immediately
Terminal 15 on and engine running
Voltage in onboard electrical system > 11 V
Induction air temperature at start between -10 and 60°C, ambient temperature > -10°C
Time parked > 360 min, time after start > 10 sec.
none
none
none
Temperature sensor sticks at upper end of temperature range, sensor tampering.
- Visual inspection of sensor and wiring
- Determine whether coolant temperature really remains constant while the engine warms up
- Replace sensor
MIL ON, electrical water pump and E fan at full power with engine running
none
0x2EEC
12012
Temperature sensor cooler outlet, plausibility
Radiator Coolant Temperature Sensor
Cold Start
Engine must be running
no debounce, fault code entered when engine is extremely cold (coolant temperature < -10°C) with excessively high sensor data reading immediately after engine start
Terminal 15 ON
11 V < electrical system voltage < 26 V
Coolant temperature < -10°C, induction air temperature < -10°C
none
none
none
N
Readings transmitted by temperature sensor too high (coolant temperature_2 > coolant temperature just after start in cold environment): Sticking sensor, sensor manipulation.
- Visual inspection of sensor
- Perform electrical check on sensor and power-supply wires
- Test to determine whether the temperature really changes when the thermostat opens
- Replace sensor
MIL ON in US versions only
temperature condition defined by data entry
0x2EEB
12011
Temperature sensor, radiator outlet, plausibility: gradient
Radiator Coolant
Temperature
Radiator discharge temperature plausibility monitor
600 msec.
Terminal 15 ON
Voltage in onboard electrical system > 9.15 V
Coolant temperature > -10°C, induction air temperature > -10°C OBD test conditions??
10 Min ?? OBD DC?
none
none
N
Creeping contact resistance or intermittent contact in sensor/power wires
- Perform electrical check on sensor wire and power-supply wires
- Visual inspection of plug-in contacts (on component and DME ends)
- Replace sensor
MIL ON in US versions only
none
0x2EE3
12003
Coolant temperature sensor, plausibility: gradient
Engine Coolant
Temperature
UBatt > 9.15 V Terminal 15 on
600 ms
Terminal 15 ON
Voltage in onboard electrical system > 9.15 V
none
none
none
none
N
Creeping contact resistance or intermittent contact in sensor/power wires.
- Perform electrical check on sensor wire and power-supply wires
- Visual inspection of plug-in contacts (on component and DME ends)
- Replace sensor
MIL ON, electrical water pump and E fan at full power with engine running
none
0x2EE2
12002
Coolant temperature sensor, plausibility: signal constant
Engine Coolant
Temperature
Engine must be running
immediately
Terminal 15 ON
Voltage in onboard electrical system > 9.15 V
Coolant temperature at start < 65°C
Entry registered when sensor reading remains constant during engine warm-up phase (up to 10 min)
none
none
N
Temperature sensor seizing, sensor manipulation
- Visual inspection of sensor
- Test to determine whether coolant temperature really remains constant as engine warms
- Sensor replacement
MIL ON, electrical water pump and E fan at full power with engine running.
Temperature condition defined indirectly by data entry
0xCD87
52615
PT-CAN communication fault
Communication
Powertrain
none
none
none
none
none
none
none
none
none
none
none
none
none
0xCD8B
52619
PT CAN bus communication fault
Communication
Local
Terminal 15 on and EKP control module connected to LoCan
Currently deactivated
none
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Short circuit in CAN bus
- Check CAN wires
- Check plugs to all CAN stations
none
CAN BUS OFF
0x2F77
12151
Ambient-pressure sensor, plausibility
Ambient Pressure Sensor
Pressure
Ambient pressure sensor monitor
Because an excessively steep ambient pressure gradient must be detected, no precise statements regarding debounce time are possible.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
N
ambient pressure rises too rapidly
- Plausibility check on barometric pressure (data range and sensor travel during mountain ascent and descent)
- Replace DME only if barometric pressure data are implausible (internal component)
MIL ON in US versions only
none
0x2F77
12151
Ambient-pressure sensor, plausibility
Ambient Pressure Sensor
Pressure
Ambient pressure sensor monitor
Because an excessively steep ambient pressure gradient must be detected, no precise statements regarding debounce time are possible.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
N
excessively rapid decline in ambient pressure
- Plausibility check on barometric pressure (data range and sensor travel during mountain ascent and descent)
- Replace DME only if barometric pressure data are implausible (internal component)
MIL ON in US versions only
none
0x2E97
11927
Generator
No Info
No Info
Mech. fault
Commercial vehicle >350 rpm, No communications fault
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
25 sec.
none
none
N
Alternator fails to turn => bearing damage, belt torn
Check bearings, replace belt
Charge indicator lamp
Can occur during vehicle servicing when external power source is connected, etc.
0x2F71
12145
Electronics-box fan, activation
No Info
No Info
E-module fan activation-control monitor. Component must be installed. Tester must be used to trigger component for at least 15 sec.
2 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
5 sec.
none
none
N
Wire is shorted to positive, or a short to positive is present in the component
Check wiring. Repair if defective. If wiring is OK proceed to check component.
No display
none
0x2F71
12145
Electronics-box fan, activation
No Info
No Info
E-module fan activation-control monitor. Component must be installed. Tester must be used to trigger component for at least 15 sec.
2 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
5 sec.
none
none
N
Short circuit to ground in wire or component.
Check wiring. Repair if defective. If wiring is OK proceed to check component.
No display
none
0x2F71
12145
Electronics-box fan, activation
No Info
No Info
E-module fan activation-control monitor. Component must be installed. Tester must be used to trigger component for at least 15 sec.
5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
5 sec.
none
none
N
Open circuit
Check wiring. Repair if defective. If wiring is OK proceed to check component.
No display
none
0x2FA4
12196
Incorrect data record
ECM Monitoring
Coding
Always active
none
Terminal 15 ON
none
none
none
none
none
N
Incorrect data set in DME or incorrect code entered in DME
Data programming, of fault remains active re-enter DME code, if then still active replace the DME.
Reduced output
OL/UL code: Codes for CAS and/or code in data set and/or DME code do not match.
0x2ED3
11987
Generator, type incorrect
No Info
No Info
Commercial vehicle > 350 rpm, No communications fault
25 sec.
Terminal 15 ON, no BSD fault
Voltage in onboard electrical system > 10 V
none
none
none
none
Y
Alternator not approved for use in this vehicle installed
Install alternator with approved detail number
none
If detail number is identical to approved number, information through VS to EA
0x2E97
11927
Generator
No Info
No Info
Implausible alternator version
Commercial vehicle >350 rpm, No communications fault
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
25 sec.
none
none
N
Alternator not approved for use in this vehicle installed
Install alternator with approved detail number
none
If detail number is identical to approved number, information through VS to EA
0x2ED0
11984
Generator, plausibility: temperature
No Info
No Info
Diagnosis not active, specific to application
Never, diagnosis not active
Terminal 15 ON, no BSD fault
none
none
none
none
none
Y
Alternator airflow obstructed. Thermal overload from unfavorable driving profile possible.
Inspect alternator for unobstructed air current.
none
none
0x2ED1
11985
Generator, mechanical
No Info
No Info
Commercial vehicle >350 rpm, No communications fault.
25 sec.
Terminal 15 ON, no BSD fault
Voltage in onboard electrical system > 10 V
none
none
none
none
N
Alternator fails to turn; bearing defect, belt slips or ruptures
Check alternator shaft for resistance to motion, replace belt
Charge indicator lamp
Can occur during vehicle servicing when external power source is connected, etc.
0x2ED2
11986
Generator, regulator incorrect
No Info
No Info
none
25 sec.
Terminal 15 ON, no BSD fault
none
none
none
none
none
Y
Installed regulator was not approved for this vehicle/this alternator.
Install regulator with approved detail number
none
If detail number is identical to approved number, information through VS to EA
0x2E96
11926
Generator, under-excitation
No Info
No Info
Commercial vehicle > 350 rpm, alternator underexcitation requested
Never, diagnosis not active
Terminal 15 ON
none
none
none
none
none
Y
Communications fault on BSD bus while PM is requesting alternator underexcitation.
- Alternator (BSD-BUS) not connected
- Open wire (BSD-BUS) between alternator and DME
- Alternator defect
- Check wire (BSD_BUS) connecting alternator and DME.
- Check plug-in connection at alternator.
- Replace alternator.
MIL relevance not yet defined
none
0x2ECE
11982
Generator, plausibility: electric
No Info
No Info
Specified alternator voltage > Application threshold 1 AND battery voltage < Application threshold 2; no electrical, mechanical or overheating faults, no active excitation current
Never, diagnosis not active
Terminal 15 ON
none
none
none
none
none
Y
B+ - Wire: Open or high contact resistance; Alternator defect. Battery defect.
Repair B+ wire Check alternator, repair as indicated Check battery, repair as indicated
none
none
0x2DC8
11720
No message from EGS, EGS 1
Communication
TCM
EGS detected
5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
5 sec.
none
none
N
Timeout on EGS message
Check CAN link to EGS control module
none
none
0x2DD2
11730
No message from SAS control module, SAS
No Info
No Info
- CAN 11 vehicle (E46, E85, E83)
- No short circuit on the PT CAN
- LWS1 message initialized
5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
400 ms
none
none
N
No reception of CAN message LWS1 possible.
Check CAN link between LWS and DME
none
LWS1-CAN message timeout
0xCDAF
52655
Message (status, trailer, 2E4)
No Info
No Info
Trailer module recognized
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between trailer module and DME
none
Timeout on CAN message
0x2DE3
11747
No message from instrument cluster, instrument cluster 7
Communication
Instrument Pack
- CAN 11 vehicle (E46, E85, E83)
- No short circuit on the PT CAN
- INSTR7 message initialized
500 sec.
Terminal 15 on
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check instrument cluster/CAN link to instrument cluster control module
none
Timeout message 'INSTR_7 '
0x2F4C
12108
Message EWS-DME incorrect
No Info
No Info
EWS code request
2
Terminal 15 on without running engine
none
none
none
none
CAN bus telegrams
N
Messages are not received
Problem diagnosis through CAS and/or gateway.
none
none
0x2DCC
11724
No message from ASC/DSC, ASC 1
No Info
No Info
- CAN 11 vehicle (E46, E85, E83)
- No short circuit on the PT CAN
- ASR_1 Message initialized
0.8 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
400 ms
none
none
N
No reception of CAN message ASC1 possible.
Check CAN link between DSC and DME.
none
Timeout on ASC1 CAN message
0x2DCD
11725
No message from ASC/DSC, ASC 3
No Info
No Info
- CAN 11 vehicle (E46, E85, E83)
- No short circuit on the PT CAN
- ASR_3 Message initialized
0.8 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
400 ms
none
none
N
No reception of CAN message ASC3 possible.
Check CAN link between DSC and DME
none
Timeout on ASC3 CAN message
0x2DCE
11726
No message from ASC/DSC, ASC 4
No Info
No Info
- CAN 11 vehicle (E46, E85, E83)
- No short circuit on the PT CAN
- ASR_4 Message initialized
0.8 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
400 ms
none
none
N
No reception of CAN message ASC4 possible.
Check CAN link between DSC and DME
none
Timeout on ASC4 CAN message
0xCD94
52628
Message (outside temperature/relative time, 310)
Communication
Ambient Temperature/Relative Time
Instrument cluster recognized
20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN links between instrument cluster and DME.
none
Timeout on CAN message
0xCD95
52629
Message (operation, vehicle-speed controller/ACC, 194)
No Info
No Info
Cruise control lever recognized
1000 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check SZL control module
none
Incorrect alive counter transmission from SZL
0xCD95
52629
Message (operation, vehicle-speed controller/ACC, 194)
No Info
No Info
Cruise control lever recognized
1000 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between SZL and DME
none
Timeout on CAN message
0xCD95
52629
Message (operation, vehicle-speed controller/ACC, 194)
No Info
No Info
Cruise control lever recognized
1000 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check SZL control module
none
Incorrect check sum transmitted by SZL
0xCD96
52630
Message (torque request ACC, B7)
No Info
No Info
ACC recognized
80 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check ACC control module
none
Incorrect alive counter transmission from ACC.
0xCD96
52630
Message (torque request ACC, B7)
No Info
No Info
ACC recognized
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between ACC and DME
none
Timeout on CAN message
0xCD96
52630
Message (torque request ACC, B7)
No Info
No Info
ACC recognized
80 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check ACC control module
none
Incorrect check sum transmitted by ACC
0xCD97
52631
Message (torque request AFS, B9)
No Info
No Info
AFS recognized
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message.
Check AFS control module.
none
Incorrect alive counter transmission from AFS
0xCDB3
52659
Message (torque request, steering, B1h)
No Info
No Info
EHB3 recognized
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check EHB3 control module
none
Alive counter transmission fault in message from EHB3
0xCD97
52631
Message (torque request AFS, B9)
No Info
No Info
AFS recognized
800 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between AFS and DME
none
Timeout on CAN message
0xCDB3
52659
Message (torque request, steering, B1h)
No Info
No Info
EHB3 recognized
800 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between EHB3 and DME
none
Timeout on CAN message
0xCD97
52631
Message (torque request AFS, B9)
No Info
No Info
AFS recognized
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check AFS control module
none
Incorrect check sum transmitted by AFS
0xCDB3
52659
Message (torque request, steering, B1h)
No Info
No Info
EHB3 recognized
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check EHB3 control module
none
EHB3 has transmitted incorrect checksum
0xCD98
52632
Message (torque request DSC, B6)
No Info
No Info
Always active
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check DSC control module
none
Incorrect DSC alive counter transmission
0xCD98
52632
Message (torque request DSC, B6)
No Info
No Info
Always active
800 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between DSC and DME
none
Timeout on CAN message
0xCD98
52632
Message (torque request DSC, B6)
No Info
No Info
Always active
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check DSC control module
none
Incorrect check sum transmission from DSC
0xCD99
52633
Message (torque request EGS, B5)
Communication
Torque Request AT
EGS detected
200 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check EGS and replace as indicated (fault in EGS control module).
MIL ON
Incorrect alive counter transmission from EGS
0xCDB8
52664
not translated
Communication
Torque Request AT
none
none
none
none
none
none
none
none
none
none
none
none
none
0xCD99
52633
Message (torque request EGS, B5)
Communication
Torque Request AT
EGS detected
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check EGS/CAN link to EGS control module
MIL ON
Timeout on EGS message
0xCDB8
52664
not translated
Communication
Torque Request AT
none
none
none
none
none
none
none
none
none
none
none
none
none
0xCDB9
52665
Message (status EMF, 201)
No Info
No Info
Message 'STATUS_EMF ' recognized
2.2 sec.
Terminal 15 on
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check EHB3 and replace as indicated (fault in EHB3 control module)
none
Alive counter fault in transmission from EHB control module
0xCDBA
52666
Message (positioning request EMF, 1A7)
No Info
No Info
Message 'STAT_ZV_KLAPPEN ' recognized
11 sec.
Terminal 15 on
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check EHB3 and replace as indicated (fault in EHB3 control module)
none
Alive counter fault in transmission from EHB control module
0xCD99
52633
Message (torque request EGS, B5)
Communication
Torque Request AT
EGS detected
200 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check EGS and replace as indicated (fault in EGS control module)
MIL ON
Incorrect check sum transmission from EGS
0xCDB8
52664
not translated
Communication
Torque Request AT
none
none
none
none
none
none
none
none
none
none
none
none
none
0xCDB9
52665
Message (status EMF, 201)
No Info
No Info
Message 'STATUS_EMF ' recognized
2.2 sec.
Terminal 15 on
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check EHB3 and replace as indicated (fault in EHB3 control module)
none
Checksum from EHB control module not transmitted correctly
0xCDBA
52666
Message (positioning request EMF, 1A7)
No Info
No Info
Message 'STAT_ZV_KLAPPEN ' recognized
11 sec.
Terminal 15 on
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check EHB3 and replace as indicated (fault in EHB3 control module)
none
Checksum from EHB control module not transmitted correctly
0xCDB9
52665
Message (status EMF, 201)
No Info
No Info
Message 'STATUS_EMF ' recognized
2.2 sec.
Terminal 15 on
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check EHB3 or CAN link to EHB3 control module
none
Timeout message 'STATUS_EMF '
0xCDBA
52666
Message (positioning request EMF, 1A7)
No Info
No Info
Message 'STAT_ZV_KLAPPEN ' recognized
11 sec.
Terminal 15 on
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check EHB3 or CAN link to EHB3 control module
none
Timeout message 'EMF control request'
0xCDBE
52670
not translated
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0xCD9B
52635
Message (vehicle mode, 315)
No Info
No Info
Sport switch recognized
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check SZM control module
none
Alive counter from SZM transmitted incorrectly.
0xCD9B
52635
Message (vehicle mode, 315)
No Info
No Info
Sport switch recognized
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between SZM and DME
none
Timeout on CAN message
0xCD9B
52635
Message (vehicle mode, 315)
No Info
No Info
Sport switch recognized
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check SZM control module
none
SZM has transmitted incorrect check sum
0xCD9C
52636
Message (speed, 1A0)
No Info
No Info
Always active
800 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between DSC and DME
none
Timeout on CAN message
0xCD9D
52637
Message (transmission data, BA)
No Info
No Info
EGS/SMG recognized
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Timeout on transmission data message
Check EGS/SMG control module and CAN links
MIL ON
none
0xCD9E
52638
Message (transmission data 2, 1A2)
No Info
No Info
EGS detected
800 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check EGS and/or CAN link to EGS control module
none
Timeout on EGS message
0xCD9F
52639
Message (mileage/range, 330)
No Info
No Info
Instrument cluster recognized
120 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN links between instrument cluster and DME.
none
Timeout on CAN message
0xCDA0
52640
Message (terminal status, 130)
No Info
No Info
Always active
100 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check CAS and replace as indicated (fault in CAS control module)
none
Incorrect alive counter transmission from CAS
0xCDA0
52640
Message (terminal status, 130)
No Info
No Info
Always active
200 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAS and/or CAN link to CAS control module
none
Timeout on CAS terminal status message
0xCDA0
52640
Message (terminal status, 130)
No Info
No Info
Always active
100 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect checksum in CAN message
Check CAS and replace as indicated (fault in CAS control module)
none
Incorrect checksum transmitted by CAS
0xCDA1
52641
Message (steering wheel angle, C4)
No Info
No Info
Steering wheel angle message recognized at least once
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between DSC and DME
none
Timeout on CAN message
0xCDA2
52642
Message (power management, battery voltage, 3B4)
Communication
Powermanagement
Vehicle version is E65
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between power module and DME
none
Timeout on CAN message
0xCDA3
52643
Message (power management, charging voltage, 334)
No Info
No Info
Vehicle version is E65
20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between power module and DME
none
Timeout on CAN message
0xCDA4
52644
Message (status ARS module, 1AC)
No Info
No Info
ARS recognized
400 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message
Check ARS control module
none
Incorrect alive counter transmission from ARS
0xCDA4
52644
Message (status ARS module, 1AC)
No Info
No Info
ARS recognized
800 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between ARS and DME
none
Timeout on CAN message
0xCDA5
52645
Message (status DSC, 19E)
No Info
No Info
Always active
800 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between DSC and DME
none
Timeout on CAN message
0xCDA6
52646
Message (status el. fuel pump, 335)
No Info
No Info
EKP recognized
40 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between EKP and DME
none
Timeout on CAN message
0xCDA7
52647
Message (status, reverse gear, 3B0)
No Info
No Info
'Reverse gear status' recognized at least once
40 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
- With manual transmission: Not possible to receive CAN message.
- With automatic/SMG: Light module periodically transmits 'Reverse gear status' (owing to incorrect code entry, etc.)
- With manual transmission: Check CAN link between light module and DME.
- With automatic/SMG: Check code entry in light module, delete version in DME and re-initialize (Terminal 15 switch)
none
Timeout on CAN message or (temporary) incorrect light module code entry
0xCDA8
52648
Message (status, instrument cluster, 1B4)
Communication
Instrument Pack
Instrument cluster recognized
500 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Incorrect alive counter in CAN message.
Check instrument cluster control module.
none
Incorrect alive counter transmission from instrument cluster.
0x2DD0
11728
No message from instrument cluster, instrument cluster 2
Communication
Instrument Pack
- CAN 11 vehicle (E46, E85, E83)
- No short circuit on the PT CAN
- INSTR2 message initialized
20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
400 ms
none
none
N
No reception of CAN message INSTR2 possible.
Check CAN links between instrument cluster and DME
none
Timeout on INSTR2 CAN message
0x2DD1
11729
No message from instrument cluster, instrument cluster 3
Communication
Instrument Pack
- CAN 11 vehicle (E46, E85, E83)
- No short circuit on the PT CAN
- INSTR3 message initialized
20 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
400 ms
none
none
N
No reception of CAN message INSTR3 possible.
Check CAN links between instrument cluster and DME
none
Timeout INSTR3 CAN message
0xCDA8
52648
Message (status, instrument cluster, 1B4)
Communication
Instrument Pack
Instrument cluster recognized
700 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN links between instrument cluster and DME
none
Timeout on CAN message
0xCDA9
52649
Message (A/C request, 1B5)
No Info
No Info
Air conditioner recognized
40 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between IHKA and DME
none
Timeout on CAN message
0xCDAA
52650
Message (status, crash deactivation, el. fuel pump, 135)
No Info
No Info
EKP recognized
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between EKP and DME
none
Timeout on CAN message
0x2F11
12049
Radiator blind, top
No Info
No Info
- AKKS must be initialized. Operation of lower flap: 3 x open and 3 x closed. Or conduct the system test.
none
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
No info.
PWM of 5-90 %
N
Defective in valve control's electronic circuitry. PVE: Insert a 1K resistor in front of Terminal 87 at DME PIN 1--09.
- Check voltage supply to AKKS (focus especially on GND [PIN 2] at the valve)
- If OK, then replace AKKS
no external display
There is no danger with the AKKS provided the malfunction did not arise while it was closed.
0x2ECC
11980
Generator, communication
No Info
No Info
Commercial vehicle >350 rpm, No communications fault.
25 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
N
- Alternator (BSD-BUS) not connected
- Open wire (BSD-BUS) between alternator and DME
- Alternator defect
- Check wire (BSD_BUS) connecting alternator and DME.
- Check plug-in connection at alternator.
- Replace alternator.
No warning message. The alternator responds to loss of the BSD_BUS signal by charging at a constant 14.4 V battery.
none
0x2E98
11928
Generator, communication
No Info
No Info
Alternator communications monitor
Commercial vehicle >350 rpm, No communications fault.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
approximately 10 sec.
none
none
N
- Alternator (BSD-BUS) not connected
- Open wire (BSD-BUS) between alternator and DME
- Alternator defect
- Check wire (BSD_BUS) connecting alternator and DME.
- Check plug-in connection at alternator.
- Replace alternator.
No warning message. The alternator responds to loss of the BSD_BUS signal by charging at a constant 14.4 V battery.
none
0xCDAB
52651
Message (lamp status, 21A)
No Info
No Info
'Lamp status' message recognized at least once
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between light module and DME.
none
Timeout on CAN message
0xCDAC
52652
Message (status, water valve, 3B5)
No Info
No Info
'Water valve' status message recognized at least once
200 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between IHKA and DME
none
Timeout on CAN message
0xCDB1
52657
Message (status, central locking, 2FC)
No Info
No Info
Message 'STAT_ZV_KLAPPEN ' recognized
4 sec.
Terminal 15 on
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAS/CAN link to CAS control module
none
Timeout message 'STAT_ZV_KLAPPEN '
0xCDAE
52654
Message (time/date, 2F8)
No Info
No Info
Instrument cluster recognized
240 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN links between instrument cluster and DME.
none
Timeout on CAN message
0xCDAD
52653
Message (request, wheel torque, drivetrain, BF)
No Info
No Info
LDM recognized
80 ms
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check LDM and CAN link to LDM control module.
none
Timeout on CAN message
0xCDB0
52656
Message (display, transmission data)
No Info
No Info
EGS detected
8 sec
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check EGS and/or CAN link to EGS control module.
none
Timeout on EGS message
0x2DC9
11721
No message from EGS, EGS 2
Communication
TCM
EGS detected
5 sec.
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
5 sec.
none
none
N
Timeout on EGS message
Check CAN link to EGS control module
none
none
0x2DC9
11721
No message from EGS, EGS 2
Communication
TCM
Symptom is not used
none
none
none
none
none
none
none
none
none
none
none
none
0x2DC9
11721
No message from EGS, EGS 2
Communication
TCM
Symptom is not used
none
none
none
none
none
none
none
none
none
none
none
none
0xCDB4
52660
Message (gearbox data, 3B1)
No Info
No Info
Message 'Transmission data 3 ' recognized
Currently data content defined (pending)
Terminal 15 ON
Voltage in onboard electrical system > 10 V
none
none
none
none
none
Unable to receive CAN message.
Check CAN link between DME and EGS/DKG
none
Timeout on CAN message
0xCDB4
52660
Message (gearbox data, 3B1)
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0xCDB4
52660
Message (gearbox data, 3B1)
No Info
No Info
none
none
none
none
none
none
none
none
none
none
none
none
none
0x2F4C
12108
Message EWS-DME incorrect
No Info
No Info
EWS code request
2
Terminal 15 on without running engine
none
none
none
none
CAN bus telegrams
N
Telegram structure not as expected
Continue problem diagnosis with CAS
none
none
0x2ADB
10971
EAC sensor, communication
Communication
Direct Ozone Reduction Catalyst Temp. Sensor
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME.
2.5 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
N
Open wire from ground, Terminal 87 or LIN bus from the DME to the EAC sensor. Defective EAC sensor.
- Check ground wire from DME to EAC sensor
- Check positive wire from DME to EAC sensor
- Check bus wire from DME to EAC sensor
- Replace sensor
MIL comes on after 2nd driving cycle
none
0x2ADB
10971
EAC sensor, communication
Communication
Direct Ozone Reduction Catalyst Temp. Sensor
EAC sensor must be installed, and the correct data set (SULEV) must be programmed in the DME.
2.5 sec.
Terminal 15
Voltage in onboard electrical system > 9 V
none
none
none
LIN bus signal
N
Open wire from ground, Terminal 87 or LIN bus from the DME to the EAC sensor. Defective EAC sensor.
- Check ground wire from DME to EAC sensor
- Check positive wire from DME to EAC sensor
- Check bus wire from DME to EAC sensor
- Replace sensor
MIL comes on after 2nd driving cycle
none