64 11 Housing, Heater/Air Conditioner
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ Bulkhead adapter | E85, E86 | 1.0 ± 0.3 Nm | ||
| 2AZ Fan for heater/air conditioner | E85, E86 | 1.5 ± 0.3 Nm | ||
| 3AZ Controller for heater - A/C system fan | E85, E86 | 1.0 ± 0.3 Nm | ||
| 4AZ Air conditioner to bulkhead | E60, E61, E63, E64, E83, E81, E87, E90, E91, E92, E93 | 6 Nm | ||
| E70 | 6.5 Nm | |||
| 5AZ Cooler box to luggage compartment partition wall | E65, E66, E67 | 4.5 Nm | ||
| 6AZ Air conditioner to support tube | E81, E87, E90, E91, E92, E93 | 9 Nm | ||
| 7AZ Mounting, positive/negative lead, to electric auxiliary heater | E83 | 8.8 Nm |
TIGHTENING TORQUES - HOUSING, HEATER/AIR CONDITIONER
64 12 Additional Heater with Controls
| Type | Thread | Tightening specification | Dimension | |
|---|---|---|---|---|
| 1AZ Additional heater to body floor | All | 4.5 Nm | ||
| 2AZ Glow plug | E24 | 17.5 Nm | ||
| E31 / E32 / E34 | 4 Nm | |||
| 3AZ Temperature sensor | E31 / E32 / E34 | 0.5 Nm | ||
| 4AZ Oil control plug and oil filler plug | All | 16 Nm | ||
| 5AZ Mounting screws | All | M5 | 6 Nm | |
| All | M6 | 10 Nm | ||
| All | M8 | 24 Nm | ||
| All | M10 | 48 Nm | ||
| 6AZ Screws for filter cover | All | 0.9 Nm | ||
| 7AZ Central cover on heater | All | 1.5 Nm | ||
| 8AZ Combustion air fan unit on heater | All | 1.5 Nm | ||
| 9AZ Recirculating pump on heater | All | 1.5 Nm | ||
| 10AZ Control unit/transfers heat to heater Install screws with Loctite 243 | All | 4.5 Nm |
TIGHTENING TORQUES - ADDITIONAL HEATER WITH CONTROLS
64 12 Independent Heater
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ Exhaust muffler to floor pan | E70 | 2.5 Nm | ||
| 2AZ Bracket, independent heater, to floor plate | E70 | 7.6 Nm | ||
| 3AZ Bracket, auxiliary water pump, to independent heater | E70 | 8.0 Nm | ||
| 4AZ Rubber mount to independent heater | E70 | 8.0 Nm | ||
| 5AZ Bracket, fuel pump, to floor pan | E70 | 7.6 Nm |
TIGHTENING TORQUES - INDEPENDENT HEATER
64 51 Air Conditioner (Evaporator) Control Units
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ High/medium pressure pressostat Bolt cement, Part No. 81 22 9 407 144. | E32 / E34 | 25 Nm | ||
| 2AZ Low pressure pressostat. Bolt cement, Part No. 81 22 9 407 144 | E32 / E34 | 19 Nm | ||
| 3AZ Three-way safety switch | E32 / E34 | 25 Nm |
TIGHTENING TORQUES - AIR CONDITIONER (EVAPORATOR) CONTROL UNITS
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ Bulkhead adapter | E85, E86 | 1.0 ± 0.3 Nm | ||
| 2AZ Fan for heater/air conditioner | E85, E86 | 1.5 ± 0.3 Nm | ||
| 3AZ Controller for heater - A/C system fan | E85, E86 | 1.0 ± 0.3 Nm | ||
| 4AZ Air conditioner to bulkhead | E60, E61, E63, E64, E83, E81, E87, E90, E91, E92, E93 | 6 Nm | ||
| E70 | 6.5 Nm | |||
| 5AZ Cooler box to luggage compartment partition wall | E65, E66, E67 | 4.5 Nm | ||
| 6AZ Air conditioner to support tube | E81, E87, E90, E91, E92, E93 | 9 Nm | ||
| 7AZ Mounting, positive/negative lead, to electric auxiliary heater | E83 | 8.8 Nm |
TIGHTENING TORQUES - HOUSING, HEATER/AIR CONDITIONER
64 52 A/C Compressor
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ Refrigerant lines to A/C compressor | E70 | M8 | 21 Nm | |
| E60 / N47, E61 / N47, E81, E87, E82, E90 / N47, E91 / N47, E92 / N47 | M8 | 18.5 Nm | ||
| E92 / S65 | M8 | 21 Nm | ||
| 2AZ Filler plug, A/C compressor | E70 | 30 ±1 Nm | ||
| E81 / N43, E82 | 25 Nm | |||
| 3AZ A/C compressor to carrier | N52, N52K | M8 x 87 | Replace aluminium screw/bolt | 10 Nm + 180±15 ° |
| M8 x 87 | Replace aluminium screw/bolt | 10 Nm + 90±15 ° | ||
| N43 | M8 | 23 Nm | ||
| N47 | M8 | 19 Nm | ||
| N54 | M8 | 19 Nm | ||
| N55 | M8 | 19 Nm | ||
| M57 | M8 | 19 Nm | ||
| N62 | M8 | 21.4 ± 3.2 Nm | ||
| N63 | M8 | 21.4 ± 3.2 Nm | ||
| S63 | M8 | 21.4 ± 3.2 Nm | ||
| 5AZ Bearing support, compressor, to crankcase | E70 / E71 | 19 Nm | ||
TIGHTENING TORQUES - A/C COMPRESSOR
64 53 Refrigerant Lines and Expansion Valve
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ Refrigerant lines to expansion valve/double pipe | E70 | M6 | 8.8 Nm | |
| 2AZ Expansion valve to heater - A/C | E70 | M6 | 5.5 Nm | |
| 3AZ Refrigerant lines to condenser | E70 | M8 | 18 Nm | |
| 4AZ Refrigerant lines to A/C compressor | E70 | M8 | 21 Nm | |
| 5AZ Pressure/suction lines to double pipe | E70 | M8 | 18 Nm | |
| 6AZ Pressure sensor in refrigerant line | E70 | 10 Nm |
TIGHTENING TORQUES - REFRIGERANT LINES AND EXPANSION VALVE
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ Bulkhead adapter | E85, E86 | 1.0 ± 0.3 Nm | ||
| 2AZ Fan for heater/air conditioner | E85, E86 | 1.5 ± 0.3 Nm | ||
| 3AZ Controller for heater - A/C system fan | E85, E86 | 1.0 ± 0.3 Nm | ||
| 4AZ Air conditioner to bulkhead | E60, E61, E63, E64, E83, E81, E87, E90, E91, E92, E93 | 6 Nm | ||
| E70 | 6.5 Nm | |||
| 5AZ Cooler box to luggage compartment partition wall | E65, E66, E67 | 4.5 Nm | ||
| 6AZ Air conditioner to support tube | E81, E87, E90, E91, E92, E93 | 9 Nm | ||
| 7AZ Mounting, positive/negative lead, to electric auxiliary heater | E83 | 8.8 Nm |
TIGHTENING TORQUES - HOUSING, HEATER/AIR CONDITIONER
| Type | Thread | Tightening specification | Measure | |
|---|---|---|---|---|
| 1AZ Refrigerant lines to expansion valve/double pipe | E70 | M6 | 8.8 Nm | |
| 2AZ Expansion valve to heater - A/C | E70 | M6 | 8.8 Nm | |
| 3AZ Refrigerant lines to condenser | E70 | M8 | 18 Nm | |
| 4AZ Refrigerant lines to A/C compressor | E70 | M8 | 21 Nm | |
| 5AZ Pressure/suction lines to double pipe | E70 | M8 | 18 Nm | |
| 6AZ Pressure sensor in refrigerant line | E70 | 10 Nm |
TIGHTENING TORQUES - REFRIGERANT LINES AND EXPANSION VALVE