15.28.1 System Overview
Regarding the boost pressure control system the following comprehensive components are monitored
Scheme 78
- Electrical monitoring of all solenoid valves
- Functional response check of control flaps Control flap high pressure charger: Failure recognition with boost pressure governor deviation Control flap high pressure bypass: Failure recognition with boost pressure governor deviation
- Control flap wastegate (not emission relevant)