Information saved in
DDE
Fault code
3FC0 - P0101
Condition for fault memory entry
No debouncing. None.
Action in service
Check for leaks in mass airflow system between the mass-airflow sensor and the intake manifold/plenum.
If the mass airflow system is sealed
Replace mass-airflow sensor.
Fault effect and breakdown warning
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Driver information
Warning light
MIL
Service instruction
none
DDE
3FD0 - P0101
No debouncing. None.
Replace mass-airflow sensor.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4C2D - P0102
Debounce (1000 ms)
Warning light
MIL
none
DDE
4C2C - P0103
Debounce (1000 ms)
Check mass-airflow sensor.
Warning light
MIL
none
DDE
4BC0 - P0103
Debounce (150 ms)
- Check wires, plug connections and electrical power supply.
- If the wires, plugs and voltage supply are all ok: Replace mass-airflow sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4BC1 - P0102
Debounce (150 ms)
- Check wires, plug connections and electrical power supply.
- If the wires, plugs and voltage supply are all ok: Replace mass-airflow sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
3FF0 - P0101
Debounce (4000 ms)
- Check boost-air temperature sensor for plausibility (possibly indicates excessively high values, usually without any DTC entry).
- Check for leaks in the air-induction system between the intake-air noise attenuator, mass-airflow sensor and turbocharger.
- Check air filter.
- Examine EGR valve for sticking and to verify that it seals when closed.
- Check swirl valves for sticking.
- Check intake passages and ports and exhaust valves for carbon deposits.
If results of the tests are OK
Replace mass-airflow sensor.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
3FF1 - P0101
Debounce (4000 ms)
- Check air-induction tract between turbocharger and intake-air plenum.
- Check swirl valves for sticking.
If results of the tests are OK
Replace mass-airflow sensor.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4BC2 - P0101
Debounce (50 ms)
- Check wires and plug connections. (open circuit or short circuits in the signal wire, interruption of power supply to the mass-airflow sensor)
- If wiring and plug connections are OK: Replace mass-airflow sensor.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4C87 - P14D0
Debounce (10000 ms)
Check low-pressure EGR cooler for contamination, replace low-pressure EGR cooler as indicated.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
491E - P0607
No debouncing. None.
Replace DDE control module.
Warning light
MIL
none
DDE
4919 - P0607
No debouncing. None.
Replace DDE control module.
Warning light
MIL
none
DDE
48D9 - P0607
No debouncing. None.
Replace DDE control module.
Warning light
MIL
none
DDE
48CE - P0607
No debouncing. None.
Replace DDE control module.
Warning light
MIL
none
DDE
4B82 - P0401
Debounce (4000 ms)
Check the following potential problem sources
- Mass airflow system on engine-side of compressor is leaking.
- Leak in exhaust system upstream from turbine.
- Defective boost pressure actuator/exhaust turbocharger (in combination with errors related to the boost pressure actuator).
- Defective EGR valve (in combination with EGR valve errors).
- Throttle valve defect (in combination with throttle valve faults).
- Severe EGR cooler soot accumulation.
Applies to engines with single-stage boost: Conduct mass airflow system test.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Check diagnostic trouble codes for the named components.
DDE
4507 - P0402
Debounce (4000 ms)
Check the following potential problem sources
- Leaks in mass airflow system between the mass-airflow sensor and the compressor.
- Contaminated air filter.
- Defective mass-airflow sensor.
- Swirl valves sticking in closed position.
- Carbon deposits on intake valves.
- Defective throttle valve (in combination with throttle valve faults).
- Defective EGR valve (in combination with EGR valve faults).
- Defective turbocharger (in combination with turbocharger faults).
Applies to engines with single-stage boost: Conduct mass airflow system test.
It is possible to continue driving the vehicle, emissions deteriorate.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
Note collateral effects with boost-pressure control. Problems related to EGR can affect the boost-pressure control.
DDE
4B81 - P0402
Debounce (3000 ms)
Check the following potential problem sources
- Leak in mass airflow system between mass-airflow sensor and compressor.
- Contaminated air filter.
- Defective mass-airflow sensor.
- Swirl valves sticking in closed position.
- Carbon deposits on intake valves.
- Defective throttle valve (in combination with throttle valve faults).
- Defective EGR valve (in combination with EGR valve faults).
- Defective turbocharger (in combination with turbocharger faults).
Applies to engines with single-stage boost: Conduct mass airflow system test.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
Check diagnostic trouble codes for the named components.
DDE
4501 - P0401
Debounce (7500 ms)
Check the following potential problem sources
- Leaks in mass airflow system on engine side of compressor
- Leaks in exhaust system on engine side of turbine (combined with mass airflow plausibility errors).
- Throttle valve defect (in combination with throttle valve faults).
- Defective EGR valve (in combination with EGR valve errors).
- Defective turbocharger (in combination with turbocharger faults).
- Severe EGR cooler soot accumulation.
Applies to engines with single-stage boost: Conduct mass airflow system test.
It is possible to continue driving the vehicle, emissions deteriorate.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Note collateral effects on boost-pressure control (faults in the exhaust-gas recirculation system can affect the boost-pressure control system).
Check diagnostic trouble codes for the named components.
DDE
4B8C - P0403
Debounce (20000 ms)
Warning light
KEINE
none
DDE
4C5B - P0070
Debounce (50 ms)
Replace outside temperature sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4C52 - P007B
Debounce (50 ms)
Replace charge-air temperature sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4C51 - P040B
Debounce (50 ms)
Replace exhaust-gas temperature sensor downstream from EGR cooler.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4C50 - P041B
Debounce (50 ms)
Replace exhaust-gas temperature sensor downstream from low-pressure EGR cooler.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
3F25 - P2279
No debouncing.
On engines with multi-stage boost
Check the following potential problem sources
Leak in mass airflow system on engine-side of compressor (boost-air hose, boost-pressure sensor, intake manifold/plenum).
Applies to engines with single-stage boost
Check the following potential problem sources
Leak in mass airflow system on engine-side of compressor (boost-air hose, boost-pressure sensor, intake manifold/plenum).
Conduct mass airflow system test.
Power loss owing to lack of air mass.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
3F35 - P2279
No debouncing.
Check the following potential problem sources
- Leak in mass airflow system on engine-side of compressor (boost-air hose, boost-pressure sensor, intake manifold/plenum).
- Defective mass-airflow sensor.
Power loss owing to lack of air mass.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
- Check air mass system for leaks.
- Perform mass airflow system test.
DDE
CD87 - U0028
Debounce (400 ms)
Conduct CAN system analysis.
Check wires and plug-in connections for short circuits and opens.
Warning light
MIL
none
DDE
49F1 - U029D
Debounce (400 ms)
Conduct CAN system analysis.
Warning light
MIL
none
DDE
48F2 - P3200
Debounce (300 ms)
Replace DDE control module.
Warning light
MIL
none
DDE
474D - P026A
The intercooler's effective cooling capacity is too low.
Check air flow to the intercooler. Check cooling fins for contamination and clean as indicated.
If the air-supply duct is OK and no contamination is present
Replace intercooler.
Warning light
MIL
If contaminant deposits are discovered on/in the intercooler then the engine radiator should also be inspected for contamination.
DDE
46D7 - P0033
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace switch valve for compressor bypass valve.
Warning light
MIL_SVS
none
DDE
46D8 - P0039
Debounce (220 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE control module.
Warning light
MIL_SVS
none
DDE
46D5 - P0035
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace switch valve for compressor bypass valve.
Warning light
MIL_SVS
none
DDE
46D6 - P0034
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace switch valve for compressor bypass valve.
Warning light
MIL
none
DDE
3EF0 - P0115
None.
Replace coolant temperature sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
434A - P0117
Debounce (4000 ms)
Replace coolant temperature sensor.
Warning light
MIL
none
DDE
3EE0 - P0118
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace coolant temperature sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
3EE1 - P0117
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace coolant temperature sensor.
Warning light
MIL
none
DDE
4585 - U059E
Debounce (50 ms)
Warning light
MIL
none
DDE
4583 - U059F
Debounce (50 ms)
Warning light
MIL
none
DDE
4AEF - U0101
Debounce (100 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none
DDE
4A89 - U0101
Debounce (100 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none
DDE
4BE2 - U0101
Debounce (100 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none
DDE
4BE3 - U0101
Debounce (100 ms)
Conduct CAN system analysis.
Warning light
MIL
none
DDE
497B - P110F
Debounce (12000 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none
DDE
4C82 - P110F
Debounce (12000 ms)
Conduct CAN system analysis.
Warning light
MIL
none
DDE
481F - U029D
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx control module 1 (before SCR converter).
Warning light
MIL
none
DDE
4872 - P124E
Debounce (500 ms)
Install correct NOx sensor behind SCR converter.
Warning light
MIL
none
DDE
4871 - P124C
Debounce (500 ms)
Install correct NOx sensor before SCR converter.
Warning light
MIL
none
DDE
480F - U029E
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx control module 2 (behind SCR converter).
Warning light
MIL
none
DDE
49A2 - U0155
Debounce (6000 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none
DDE
49A3 - U0155
Debounce (6000 ms)
Conduct CAN system analysis.
Warning light
MIL
none
DDE
4DF0 - U0101
Debounce (50 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none
DDE
4DF1 - U0101
Debounce (50 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none
DDE
4DF2 - U0101
Debounce (50 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none
DDE
4DF3 - U0101
Debounce (50 ms)
Conduct CAN system analysis.
Warning light
MIL
none
DDE
49F3 - P0500
Debounce (150 ms)
Conduct CAN system analysis.
Warning light
MIL
none
DDE
486C - P124E
Debounce (500 ms)
Replace NOx sensor behind SCR converter.
Warning light
MIL
none
DDE
486B - P124C
Debounce (500 ms)
Replace NOx sensor before SCR converter.
Warning light
MIL
none
DDE
4B73 - P053A
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace crankcase ventilation heater.
Warning light
MIL
none
DDE
4B72 - P120D
Debounce (220 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE ECU.
Warning light
MIL
none
DDE
4B70 - P053C
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace crankcase ventilation heater.
Warning light
MIL
none
DDE
4B6C - P053B
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace crankcase ventilation heater.
Warning light
MIL
none
DDE
4C89 - P0128
Debounce (100 ms)
Warning light
MIL
none
DDE
4C8F - P0607
Debounce (50 ms)
Replace DDE control module.
Warning light
MIL
none
DDE
485C - P245A
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace switch valve for EGR cooler bypass valve.
Warning light
MIL
none
DDE
485D - P245B
Debounce (220 ms)
Inspect switch valve for EGR cooler bypass valve for short circuits.
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
485A - P245D
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace switch valve for EGR cooler bypass valve.
Warning light
MIL
none
DDE
485B - P245C
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace switch valve for EGR cooler bypass valve.
Warning light
MIL
none
DDE
4BDE - P062F
None.
Replace DDE control module.
Warning light
MIL
none
DDE
4AE9 - P062F
None, if debounce is defined as a constant 3.
Replace DDE control module.
Warning light
MIL
none
DDE
4AEE - P062F
None, if debounce is defined as a constant 3.
Replace DDE control module.
Warning light
MIL
none
DDE
4873 - P2457
- Check vacuum supply to the EGR cooler's bypass valve (vacuum lines and switch valve).
- If the vacuum supply is in satisfactory condition: Replace the EGR cooler (the bypass valve's return spring may be defective).
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4B39 - P0403
Debounce (220 ms)
- Check wires and plug connections. (open circuit)
- If wiring and plug connections are OK: Replace EGR actuator.
Warning light
MIL_SVS
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced.
DDE
4B3F - P0404
Debounce (220 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE control module.
Warning light
MIL_SVS
none
DDE
4B24 - P0490
Debounce (220 ms)
- Check wires and plug connections. (Short circuit)
- If wiring and plug connections are OK: Replace EGR actuator.
Warning light
MIL_SVS
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced.
DDE
4B29 - P0490
Debounce (220 ms)
- Check wires and plug connections. (Short circuit)
- If wiring and plug connections are OK: Replace EGR actuator.
Warning light
MIL_SVS
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced.
DDE
4B2E - P0489
Debounce (220 ms)
- Check wires and plug connections. (Short circuit)
- If wiring and plug connections are OK: Replace EGR actuator.
Warning light
MIL_SVS
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced.
DDE
4B2F - P0489
Debounce (220 ms)
- Check wires and plug connections. (Short circuit, leakage current)
- If wiring and plug connections are OK: Replace EGR actuator.
Warning light
MIL_SVS
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced.
DDE
4C9E - P042F
Debounce time for detection of positive control deviation 2500 ms+ time for break-away attempts with persistent control deviation 1 s or time to recognition of negative control deviation error 2500 ms+ time during which enable function is active 1 s.
With electric EGR valve
Replace EGR valve.
With pneumatic EGR valve
Check the vacuum system between the following components and repair as required
- Pressure converter for EGR valve.
- EGR valve.
If the vacuum system is OK
Replace EGR valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced.
DDE
4C9F - P042E
Debounce time for detection of a negative control deviation 2500 ms+ time for break-away attempts during persistent control deviation 1 s.
Replace EGR valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced.
DDE
478E - P045F
Debounce time for detection of a positive control deviation 5000 ms+ time for break-away attempts during persistent control deviation 3 s.
Or
Time for recognition of a negative control deviation error 5000 ms+ time during which the enable function is activated (3 s).
- Check low-pressure EGR valve.
- Replace sensors.
- Replace low-pressure EGR valve.
Warning light
MIL
none
DDE
478F - P045E
Debounce time for detection of a negative control deviation 5000 ms+ time for break-away attempts during persistent control deviation 3 s.
- Check low-pressure EGR valve.
- Replace sensors.
- Replace low-pressure EGR valve.
Warning light
MIL_SVS
none
DDE
4794 - P045A
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace low-pressure EGR actuator.
Warning light
MIL
none
DDE
4DA7 - P045B
Debounce (220 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE ECU.
Warning light
MIL
none
DDE
4799 - P045D
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace low-pressure EGR actuator.
Warning light
MIL
none
DDE
479E - P045C
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace low-pressure EGR actuator.
Warning light
MIL_SVS
none
DDE
4784 - P0408
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace low-pressure EGR actuator.
Warning light
MIL
none
DDE
4789 - P0407
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace low-pressure EGR actuator.
Warning light
MIL
none
DDE
4CA9 - P0406
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace EGR valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced
DDE
4CAE - P0405
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace EGR valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL
With some engine versions the appropriate service function must be used to reset the EGR valve's adaptation before the EGR valve is replaced.
DDE
4AD5 - P02CD
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4B15 - P02D5
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4AF5 - P02D1
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4B25 - P02D7
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4AE5 - P02CF
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4B05 - P02D3
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4AD6 - P02CC
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4B16 - P02D4
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4AF6 - P02D0
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4B26 - P02D6
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4AE6 - P02CE
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4B06 - P02D2
Event debounced (1)
Replace injector.
Warning light
MIL
none
DDE
4C6C - P244C
Debounce (20000 ms)
Check the following potential problem sources
- Mass airflow sensor contaminated/implausible air mass data.
- Pre-catalyst exhaust-gas temperature is implausible.
- Exhaust-gas temperature upstream from particulate filter is implausible. With engine cold check mutual plausibility of exhaust-gas temperatures.
- Fuel quantity drift at injectors.
Check for DTC entries related to the indicated components, repair faults.
Warning light
MIL
none
DDE
4BC3 - P244C
Event debounced (1)
Warning light
MIL
none
DDE
4DFB - P1515
Debounce (500 ms)
Start vehicle, switch it off, allow vehicle to enter sleep mode (can take up to 15 min), these steps must be carried out before the diagnostic trouble code can be deleted.
If the fault continues to appear respond by replacing the instrument cluster.
No hazard to components is present
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4D00 - P244B
Debounce (2000 ms)
- Check hose and electrical connections, test exhaust backpressure.
- If wiring and plug connections are OK: Replace differential-pressure sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4175 - P244D
Debounce (50000 ms)
- Check particulate filter and catalyst for damage.
- Check wires and plug-in connections, if OK: Replace pre-particulate filter exhaust-gas temperature sensor.
- Check EGR valve for leakage, clean as required.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4D01 - P244A
Debounce (2000 ms)
- Check sensor, hose and electrical connections, conduct backpressure test
- If wires/plug connections are OK, replace sensor.
Warning light
MIL
none
DDE
432A - P2229
Debounce (200 ms)
Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
432B - P2228
Debounce (200 ms)
Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4060 - P2229
Debounce (150 ms)
Replace DDE control module.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4061 - P2228
Debounce (50 ms)
Replace DDE control module.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4D95 - P009A
Debounce (15000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace outside-temperature sensor.
Warning light
MIL
none
DDE
4C1C - P0073
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace outside-temperature sensor.
Warning light
MIL
none
DDE
3F80 - P0073
Debounce (6000 ms) None.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace outside-temperature sensor.
Warning light
MIL
none
DDE
3F81 - P0072
Debounce (6000 ms) None.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace outside-temperature sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
42B5 - P0016
- Check bolt retaining sprocket on camshaft.
- Check sensor reluctor ring attachment.
- Check camshaft/valve timing.
- Check timing chain
Park vehicle.
Warning light
MIL
none
DDE
3E91 - P0336
200/10 Monitoring cycles
Check the following potential fault causes and repair as needed
- Intermittent contact at plug.
- Change in gap between sensor and reluctor ring (eccentric reluctor ring geometry, gap too wide, loose sensor, sensor movement).
- Crankshaft sensor defect stemming from collision with reluctor ring.
- Damaged reluctor ring.
Warning light
MIL
none
DDE
3E90 - P0335
Check the following potential fault causes and repair as needed
- The signal wire between the sensor and the control module is open or shorted to positive or ground.
- Open circuit in voltage supply or ground wire.
- Open circuit in one or both signal wires between sensor and control module.
- If the sensor is a passive sensor (inductive sensor) the gap between the crankshaft sensor and reluctor ring is too wide.
- Defective crankshaft sensor.
Warning light
MIL
none
DDE
4C04 - P0425
Debounce (60000 ms)
Replace exhaust-gas temperature sensor upstream from oxidation catalyst.
Warning light
MIL
Defective exhaust-gas temperature sensor upstream from oxidation catalyst.
DDE
4C09 - P042A
Debounce (60000 ms)
Replace pre-particulate filter exhaust-gas temperature sensor.
Warning light
MIL
Exhaust-gas temperature sensor before particulate filter defective.
DDE
4C0E - P242A
Debounce (60000 ms)
Replace exhaust-gas temperature sensor before SCR converter.
Warning light
MIL
Defective exhaust-gas temperature sensor before SCR cat.
DDE
4ABD - P0425
Debounce (100 ms)
Replace exhaust-gas temperature sensor upstream from oxidation catalyst.
Warning light
MIL
none
DDE
4ABB - P042A
Debounce (100 ms)
Replace pre-particulate filter exhaust-gas temperature sensor.
Warning light
MIL
none
DDE
4ABA - P242A
Debounce (100 ms)
Replace exhaust-gas temperature sensor before SCR converter.
Warning light
MIL
none
DDE
4674 - P323F
Debounce (5000 ms)
Warning light
MIL
none
DDE
4679 - P323F
Debounce (5000 ms)
- Check mass airflow system and exhaust system for leaks (also check before replacing parts) and repair leaks.
- If diagnostic trouble codes related to the oxygen sensor have been logged: Conduct fault diagnosis on the oxygen sensor based on the diagnostic trouble codes logged in the ECU.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Watch for leaks on exhaust-gas side behind exhaust-gas discharge for the EGR system.
DDE
435A - P0182
Debounce (4000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace fuel pressure and temperature sensor (on vehicles without closed-loop control of low-pressure fuel-delivery circuit: fuel-temperature sensor).
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4000 - P0183
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace fuel pressure and temperature sensor (on vehicles without closed-loop control of low-pressure fuel-delivery circuit: fuel-temperature sensor).
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4001 - P0182
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace fuel pressure and temperature sensor (on vehicles without closed-loop control of low-pressure fuel-delivery circuit: fuel-temperature sensor).
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4CF6 - P008F
None.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace fuel pressure and temperature sensor (on vehicles without closed-loop control of low-pressure fuel-delivery circuit: fuel-temperature sensor).
Warning light
MIL
none
DDE
4949 - P0670
Debounce (1200 ms)
Install correct glow plugs.
If the fault reoccurs: Replace glow-plug preheating control module.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A7F - P0670
Debounce (1200 ms)
Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
4A7E - P0670
Debounce (1200 ms)
- Check wires and plug connections on LIN bus.
- If wiring and plug connections are OK
- Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
4A79 - P064C
Debounce (1700 ms)
- Check wires and plug connections on LIN bus.
- If wiring and plug connections are OK: Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
4A74 - P064C
Debounce (1700 ms)
- Check wires and plug connections on LIN bus.
- If wiring and plug connections are OK: Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
4A6F - P066B
Debounce (1200 ms)
Replace glow-plug preheating control module.
Replace glow plug 1.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A6E - P0671
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 1.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A69 - P066A
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 1.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A64 - P0671
Debounce (1200 ms)
- Check wires and plug connections.
- Check part numbers of installed glow plugs, replace with correct glow plugs as indicated.
- If wiring and plug connections are OK: Replace glow plug 1.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A5F - P066D
Debounce (1200 ms)
Replace glow-plug preheating control module.
Replace glow plug 1.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A5E - P0672
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 2.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A59 - P066C
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 2.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A54 - P0672
Debounce (1200 ms)
- Check wires and plug connections.
- Check part numbers of installed glow plugs, replace with correct glow plugs as indicated.
- If wiring and plug connections are OK: Replace glow plug 2.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A4F - P066F
Debounce (1200 ms)
Replace glow-plug preheating control module.
Replace glow plug 1.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A4E - P0673
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 3.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A49 - P066E
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 3.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A44 - P0673
Debounce (1200 ms)
- Check wires and plug connections.
- Check part numbers of installed glow plugs, replace with correct glow plugs as indicated.
- If wiring and plug connections are OK: Replace glow plug 3.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A3F - P067B
Debounce (1200 ms)
Replace glow-plug preheating control module.
Replace glow plug 1.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A3E - P0674
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 4.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A39 - P067A
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 4.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A34 - P0674
Debounce (1200 ms)
- Check wires and plug connections.
- Check part numbers of installed glow plugs, replace with correct glow plugs as indicated.
- If wiring and plug connections are OK: Replace glow plug 4.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A2F - P067D
Debounce (1200 ms)
Replace glow-plug preheating control module.
Replace glow plug 1.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A2E - P0675
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 5.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A29 - P067C
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 5.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A24 - P0675
Debounce (1200 ms)
- Check wires and plug connections.
- Check part numbers of installed glow plugs, replace with correct glow plugs as indicated.
- If wiring and plug connections are OK: Replace glow plug 5.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A1F - P067F
Debounce (1200 ms)
Replace glow-plug preheating control module.
Replace glow plug 1.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A1E - P0676
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 6.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A19 - P067E
Debounce (1200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace glow plug 6.
If the fault reoccurs: Replace glow-plug preheating control module.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A14 - P0676
Debounce (1200 ms)
- Check wires and plug connections.
- Check part numbers of installed glow plugs, replace with correct glow plugs as indicated.
- If wiring and plug connections are OK: Replace glow plug 6.
Poor starting at low temperatures.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Remove glow plugs with engine warmed to normal operating temperature to avoid damage to the cylinder head.
DDE
4A0F - P0383
Debounce (1200 ms)
Check ground connections on glow-plug preheating control module and on engine.
If the fault persists: Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
4A0E - P064C
Debounce (1200 ms)
Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
4A09 - P064C
Debounce (1200 ms)
- Check wires and plug connections on LIN bus.
- If wiring and plug connections are OK: Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
494A - P0670
Debounce (1200 ms)
Check power-supply wires and plug connections at glow-plug preheating control module's Terminal 30.
If the fault reoccurs: Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
4A04 - P064C
Debounce (1200 ms)
- Check contact between glow-plug preheating control module and engine block.
- If no fault is detected: Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
49FF - P064C
Debounce (1200 ms)
- Check power-supply wires and plug connections at glow-plug preheating control module.
- If wiring and plug connections are OK: Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
4DEC - P0507
Debounce (3000 ms)
Warning light
MIL
none
DDE
4DED - P0506
Debounce (3000 ms)
Warning light
MIL
none
DDE
4BA8 - P268C
No debouncing. None.
- Repeat the injector quantity calibration for the injector and conduct a terminal status switch.
- If the fault is still present in repeat testing: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4BA6 - P2690
No debouncing. None.
- Repeat the injector quantity calibration for the injector and conduct a terminal status switch.
- If the fault is still present in repeat testing: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4BA5 - P268E
No debouncing. None.
- Repeat the injector quantity calibration for the injector and conduct a terminal status switch.
- If the fault is still present in repeat testing: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4BA3 - P2691
No debouncing. None.
- Repeat the injector quantity calibration for the injector and conduct a terminal status switch.
- If the fault is still present in repeat testing: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4BA2 - P268D
No debouncing. None.
- Repeat the injector quantity calibration for the injector and conduct a terminal status switch.
- If the fault is still present in repeat testing: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4B9D - P268F
No debouncing. None.
- Repeat the injector quantity calibration for the injector and conduct a terminal status switch.
- If the fault is still present in repeat testing: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4CE9 - P268C
No debouncing. None.
- Repeat the injector quantity compensation for the injector and conduct a terminal power-status switch.
- If the error is still present: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4CF9 - P2690
No debouncing. None.
- Repeat the injector quantity compensation for the injector and conduct a terminal power-status switch.
- If the error is still present: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4CEF - P268E
No debouncing. None.
- Repeat the injector quantity compensation for the injector and conduct a terminal power-status switch.
- If the error is still present: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4CFE - P2691
No debouncing. None.
- Repeat the injector quantity compensation for the injector and conduct a terminal power-status switch.
- If the error is still present: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4CEE - P268D
No debouncing. None.
- Repeat the injector quantity compensation for the injector and conduct a terminal power-status switch.
- If the error is still present: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4CF4 - P268F
No debouncing. None.
- Repeat the injector quantity compensation for the injector and conduct a terminal power-status switch.
- If the error is still present: Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
KEINE
none
DDE
4917 - P0611
Event debounced (4)
Replace DDE control module.
Following terminal status switch attempt to start the engine, and proceed to a service facility.
Warning light
MIL
none
DDE
4C59 - P0611
Event debounced (4)
Replace DDE control module.
Following terminal status switch attempt to start the engine, and proceed to a service facility.
Warning light
MIL
none
DDE
4B94 - P0611
Event debounced (4)
- Check wires and plug connections for all affected injectors.
- If wiring and plug connections are OK: Replace DDE control module.
Warning light
MIL
none
DDE
4B99 - P0611
Event debounced (4)
- Check wires and plug connections for all three affected injectors.
- If wiring and plug connections are OK: Replace DDE control module.
Warning light
MIL
none
DDE
4C0F - P0611
Event debounced (10)
Replace DDE control module.
Warning light
MIL_SVS
none
DDE
4C1F - P0611
Event debounced (10)
Replace DDE control module.
Warning light
MIL_SVS
none
DDE
441C - P0201
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
445C - P0205
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
443C - P0203
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
446C - P0206
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
442C - P0202
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
444C - P0204
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4BC4 - P3148
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Inspect injector: Measure resistance (at 20 - 40 °C).
Setpoint: 180 kOhm +/- 10 kOhm
If the specified value is not obtained: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL_SVS
none
DDE
4BD4 - P3160
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Inspect injector: Measure resistance (at 20 - 40 °C).
Setpoint: 180 kOhm +/- 10 kOhm
If the specified value is not obtained: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL_SVS
none
DDE
4BCE - P3154
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Inspect injector: Measure resistance (at 20 - 40 °C).
Setpoint: 180 kOhm +/- 10 kOhm
If the specified value is not obtained: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL_SVS
none
DDE
4BD9 - P3163
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Inspect injector: Measure resistance (at 20 - 40 °C).
Setpoint: 180 kOhm +/- 10 kOhm
If the specified value is not obtained: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL_SVS
none
DDE
4BC9 - P3151
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Inspect injector: Measure resistance (at 20 - 40 °C).
Setpoint: 180 kOhm +/- 10 kOhm
If the specified value is not obtained: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL_SVS
none
DDE
4BCF - P3157
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Inspect injector: Measure resistance (at 20 - 40 °C).
Setpoint: 180 kOhm +/- 10 kOhm
If the specified value is not obtained: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL_SVS
none
DDE
4934 - P0261
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4924 - P0273
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
492E - P0267
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
491F - P0276
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
492F - P0264
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4929 - P0270
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4BAE - P0262
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL
none
DDE
4BBE - P0274
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL
none
DDE
4BB4 - P0268
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL
none
DDE
4BBF - P0277
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL
none
DDE
4BAF - P0265
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL
none
DDE
4BB9 - P0271
Event debounced (4)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace injector.
Perform terminal power-status switch and attempt engine start.
Warning light
MIL
none
DDE
4954 - P0611
No debouncing. None.
Replace DDE control module.
Warning light
MIL
none
DDE
4959 - P0611
No debouncing. None.
Replace DDE control module.
Warning light
MIL
none
DDE
46E6 - P026B
Event debounced (50)
Warning light
MIL
none
DDE
46E7 - P026B
Event debounced (50)
Warning light
MIL
none
DDE
49A5 - U0106
Debounce (1200 ms)
Check LIN bus.
If LIN bus is OK
Replace glow-plug preheating control module.
Warning light
MIL
none
DDE
41D7 - P2243
Debounce (500 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
41E7 - P2237
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
41F7 - P2251
Debounce (500 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
43FD - P0133
Event debounced (2) Number 2 of consecutive defect detections. In service test diagnosis the debounce is divided by the factor 2.
- Check wires and plug connections.
- Check exhaust system for leaks, check installation of oxygen sensor.
- If wires and exhaust system are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
4205 - P0032
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
4206 - P0031
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
4207 - P0030
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
4235 - P0607
Event debounced (10) Event debounce with the counter limit 10 for defect detection as. In the service test diagnosis the debounce is divided by the factor 2.
Replace DDE control module.
Warning light
MIL
none
DDE
4236 - P0607
Event debounced (10) Event debounce with the counter limit 10 for defect detection as. In the service test diagnosis the debounce is divided by the factor 2.
Replace DDE control module.
Warning light
MIL
none
DDE
4225 - P0132
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
4226 - P0131
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
447A - P2297
Event debounced (100) The diagnostic trouble code is logged when at least 100 error events have been counted. During service test diagnosis the debounce is divided by 2.
- Check exhaust system for leaks.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
448A - P2A00
Event debounced (100) The diagnostic trouble code is logged when at least 100 error events have been counted. During service test diagnosis the debounce is divided by 2.
- Check exhaust system for leaks.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
447B - P2297
Event debounced (100) The diagnostic trouble code is logged when at least 100 error events have been counted. During service test diagnosis the debounce is divided by 2.
- Check exhaust system for leaks.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
448B - P2A00
Event debounced (100) The diagnostic trouble code is logged when at least 100 error events have been counted. During service test diagnosis the debounce is divided by 2.
- Check exhaust system for leaks.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
4258 - P3022
No debouncing.none
Replace DDE control module.
Warning light
MIL
none
DDE
49E4 - P2239
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
49EF - P2238
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace oxygen sensor.
Warning light
MIL
none
DDE
4275 - P0135
Debounce (60000 ms) 60000 ms. For brief diagnosis the time is divided by 2.
Replace oxygen sensor.
Warning light
MIL
none
DDE
4276 - P0135
Debounce (60000 ms) 60000 ms. For short-distance diagnosis the time is divided by 2.
Replace oxygen sensor.
Warning light
MIL
none
DDE
4121 - P0685
- None.
Determine whether the error is a collateral error stemming from undervoltage. If the error was not caused by undervoltage
Replace the DDE main relay.
Warning light
MIL
If this error is logged together with other errors that trigger an ECU recovery or indicate undervoltage then these problems should be resolved. The main relay malfunction may be a collateral malfunction.
DDE
4120 - P0685
- None.
Replace the DDE main relay.
Warning light
MIL
none
DDE
4300 - P0001
Debounce (100 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace fuel-quantity control valve.
If the fault reoccurs
Replace DDE control module.
Warning light
MIL_SVS
none
DDE
4310 - P0004
Debounce (100 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace fuel-quantity control valve.
Warning light
MIL_SVS
none
DDE
4320 - P0003
Debounce (100 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace fuel-quantity control valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4CE1 - P0301
- None.
Check injector.
If injector is OK: Check injector wiring and plug connections for open circuit or short (possible additional diagnostic trouble codes logged?)
Warning light
MIL
none
DDE
4CE2 - P0305
- None.
Check injector.
If injector is OK: Check injector wiring and plug connections for open circuit or short (possible additional diagnostic trouble codes logged?)
Warning light
MIL
none
DDE
4CE3 - P0303
- None.
Check injector.
If injector is OK: Check injector wiring and plug connections for open circuit or short (possible additional diagnostic trouble codes logged?)
Warning light
MIL
none
DDE
4CE6 - P0306
- None.
Check injector.
If injector is OK: Check injector wiring and plug connections for open circuit or short (possible additional diagnostic trouble codes logged?)
Warning light
MIL
none
DDE
4CE7 - P0302
- None.
Check injector.
If injector is OK: Check injector wiring and plug connections for open circuit or short (possible additional diagnostic trouble codes logged?)
Warning light
MIL
none
DDE
4CE8 - P0304
- None.
Check injector.
If injector is OK: Check injector wiring and plug connections for open circuit or short (possible additional diagnostic trouble codes logged?)
Warning light
MIL
none
DDE
4CF0 - P0300
- None.
Check injectors.
If injectors are OK: Examine injector wiring and plug connections for open or short circuits (other diagnostic trouble codes logged in ECU?)
Warning light
MIL
none
DDE
4976 - P2201
Event debounced (2000)
Warning light
MIL
DDE
496D - P2201
Debounce (2000 ms)
Warning light
MIL
DDE
496C - P229F
Event debounced (1)
- Delete the DTC if the error frequency is 1.
- Respond to multiple occurrences of this error by replacing the pre-SCR-cat NOx sensor.
Warning light
MIL
DDE
496B - P229F
Event debounced (1)
Determine whether multiple occurrences of the error are present. If the error occurs once then the DTC can simple be deleted. Respond to multiple occurrences by replacing the NOx sensor.
Warning light
MIL
DDE
4B6A - P2201
Event debounced (1)
- Delete the DTC if the error frequency is 1.
- Respond to multiple occurrences of this error by replacing the pre-SCR-cat NOx sensor.
Warning light
MIL
DDE
4BF5 - P124D
Event debounced (10)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Check NOx sensor 1 (before SCR converter).
Warning light
MIL
Replace NOx sensor 1 (before SCR catalyst)
DDE
46B4 - P2201
Event debounced (1)
Use SCR converter system check to analyze NOx sensor 1 (before SCR).
ID0004
ID0005
- 3. Replace NOx sensor 1 (before SCR).
Proceed to the nearest BMW Service facility.
Warning light
MIL
Perform metering diagnosis if indicated.
DDE
46B9 - P2201
Event debounced (1)
Use SCR converter system check to analyze NOx sensor 1 (before SCR).
ID0004
ID0005
- 3. Replace NOx sensor 1 (before SCR).
Proceed to the nearest BMW Service facility.
Warning light
MIL
DDE
4922 - P2209
Event debounced (2)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 1 (before SCR converter).
Warning light
MIL
none
DDE
4754 - P2203
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 1 (on front side of SCR converter).
Warning light
MIL
none
DDE
4759 - P2202
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 1 (on front side of SCR converter).
Warning light
MIL
none
DDE
475E - P2200
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 1 (on front side of SCR converter).
Warning light
MIL
none
DDE
475F - P122C
Debounce (2000 ms)
Replace wire (supply NOx sensor ECU or between NOx sensor ECU and NOx sensor)/check plug and/or replace NOx sensor 1 (before SCR converter).
Warning light
MIL
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 1 (on front side of SCR converter).
DDE
4BF0 - P124F
Event debounced (10)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Check NOx sensor 2 (behind SCR converter).
Warning light
MIL
Replace NOx sensor 2 (behind SCR catalyst).
DDE
4B3B - P229F
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 2 (behind SCR converter).
Warning light
MIL
none
DDE
4B3A - P229F
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace NOx sensor 2 (behind SCR converter).
Warning light
MIL
none
DDE
4724 - P229F
Debounce (2000 ms)
Replace NOx sensor 2 (behind SCR converter).
Warning light
MIL
Replace NOx sensor 2 (behind SCR converter).
DDE
4729 - P229F
Debounce (2000 ms)
Check of NOx sensor.
Warning light
MIL
none
DDE
46A4 - P229F
Event debounced (1)
Use SCR converter system check to analyze NOx sensor 2 (behind SCR converter).
ID0004
ID0005
- 3. Replace NOx sensor 2 (behind SCR converter).
Proceed to the nearest BMW Service facility.
Warning light
MIL
Perform metering diagnosis if indicated.
DDE
46A9 - P229F
Event debounced (1)
Use SCR converter system check to analyze NOx sensor 2 (behind SCR converter).
ID0004
ID0005
- 3. Replace NOx sensor 2 (behind SCR converter).
Proceed to the nearest BMW Service facility.
Warning light
MIL
DDE
4926 - P22A7
Event debounced (2)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 2 (behind SCR converter).
Warning light
MIL
none
DDE
472E - P22A1
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 2 (behind SCR converter).
Warning light
MIL
none
DDE
472F - P22A0
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace NOx sensor 2 (behind SCR converter).
Warning light
MIL
none
DDE
4744 - P229E
Debounce (2000 ms)
- Check wiring and plug-in connections (power supply to NOx sensor control module and NOx sensor).
- Replace NOx sensor 2 (behind SCR converter).
Warning light
MIL
none
DDE
4749 - P122D
Debounce (2000 ms)
- Check wiring and plug-in connections (power supply to NOx sensor control module and NOx sensor).
- Replace NOx sensor 2 (behind SCR converter).
Warning light
MIL
none
DDE
4D03 - P14A3
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas backpressure sensor.
Warning light
MIL
none
DDE
4B91 - P0420
Event debounced (1)
Replace oxidation catalyst/particulate filter.
Warning light
MIL
none
DDE
429A - P02CB
Debounce (6000 ms)
- Check mass airflow system behind large compressor for leaks.
- Check throttle valve for malfunctions.
- Check EGR valve for malfunctions.
- Check boost pressure actuator for faults.
- Check exhaust system for flow obstructions and leaks (gasket between the turbines and the exhaust manifold).
- Check compressor bypass valve for faults and sticking.
- Check turbine control flap for faults and tight sealing when closed.
- Check wastegate valve for malfunctions and to ensure that it seals when closed.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
Check diagnostic trouble codes for the named components.
DDE
428B - P02CA
Debounce (3000 ms)
- Check mass airflow system for leaks.
- Check boost pressure sensor.
- Check operation of the following components and inspect for tampering: Turbine control flap. Wastegate valve (can seize in closed position).
Active torque reduction.
Do not drive at WOT/full throttle, component hazard possible.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
- Check for diagnostic trouble codes for the named components.
DDE
4530 - P0299
Debounce (7000 ms)
Engine with single-stage boost
- Check air-induction system for leaks.
- Inspect exhaust system on engine side of turbine for leaks.
- Check throttle valve.
- Perform mass airflow system test.
Engine with multi-stage boost
- Check air-induction system for leaks.
- Inspect exhaust system on engine side of turbines for leaks. Note: An internal exhaust leak at the joint between the large turbine and exhaust manifold is possible (at sealing ring for turbine control flap).
- Check throttle valve (DTCs logged in error memory).
- Check turbine control flap.
- Check boost pressure actuator's high-pressure stage.
- Check turbocharger high-pressure stage for damage to compressor and turbine blades.
- Check wastegate valve.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL
Check diagnostic trouble codes for the named components.
Note. On the F01 with N57D30T0 manufactured up to February, 2010 the vacuum actuators for the turbine control flap may display the following damage with the passage of time
- Leaking vacuum diaphragm.
- Linkage separates from the vacuum actuator.
In this case the vacuum actuator must be replaced.
DDE
4521 - P0234
Debounce (4000 ms)
Engine with single-stage boost
- Check air-induction system for leaks.
- Check boost pressure actuator for signs of tampering.
- Perform mass airflow system test.
Engine with multi-stage boost
- Check air-induction system for leaks.
- Check turbine control flap (tampering).
- Check boost pressure actuator high-pressure stage (tampering).
Active torque reduction.
Do not drive at WOT/full throttle, component hazard possible.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
Check diagnostic trouble codes for the named components.
DDE
4330 - P0090
Debounce (100 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace rail pressure control valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4340 - P0092
Debounce (100 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace rail pressure control valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4350 - P0091
Debounce (50 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace rail pressure control valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4C4E - P228F
No debouncing. None.
Replace rail pressure control valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4C4F - P228E
No debouncing. None.
Replace rail pressure control valve.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
48E1 - P321E
Debounce (500 ms)
Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
48E0 - P321F
Debounce (500 ms)
Replace DDE control module.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
48DD - P0069
Debounce (500 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace boost-pressure sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
48DC - P0069
Debounce (500 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace boost-pressure sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4C5E - P2002
Debounce (2500 ms)
E90-M57D30T2-AT-LEVII
Debounce (4000 ms)
- Inspect to determine whether filter could be removed (carbon accumulation at tailpipe tip).
- If soot is present on the end of the tailpipe and the end of the filter then the filter is defective.
- If no soot is present on the end of the filter and at the tailpipe tip but the diagnostic trouble code has still been logged: Hose to differential-pressure sensor has fallen off or the sensor is defective (in which case a diagnostic trouble code for the differential-pressure sensor would also be logged).
Proceed to the nearest BMW Service facility.
Warning light
MIL
If the differential-pressure sensor is defective then a diagnostic trouble code for the differential-pressure sensor would also be stored.
DDE
4D99 - P14A6
Debounce (1000 ms)
Warning light
MIL
none
DDE
4B9C - P2002
- None.
- Inspect to determine whether filter could be removed (carbon accumulation at tailpipe tip).
- If soot is present on the end of the tailpipe and the end of the filter then the filter is defective.
- If no soot is visible in these places, but the diagnostic trouble code is still logged, the hose may have separated from the differential-pressure sensor or the differential-pressure sensor may be defective (in which case a diagnostic trouble code would also have to be logged for the differential-pressure sensor).
Proceed to the nearest BMW Service facility.
Warning light
KEINE
If the differential-pressure sensor is defective then a diagnostic trouble code for the differential-pressure sensor would also be stored.
DDE
4C63 - P2459
Debounce (100 ms)
- Check oil level and oil change intervals.
- Conduct exhaust-gas backpressure test to allow assessment of particulate filter condition.
- Test of swirl valves/throttle valve using activation and visual inspection.
- Check mass-airflow sensor (the error can occur if the HFM is measuring too much air).
- Perform mass airflow system test (on engines with single-stage boost).
- If swirl valves, throttle valve and mass-airflow sensor are OK: Request/conduct service regeneration if customer engages in short-distance driving.
Warning light
MIL
none
DDE
481A - P14A7
Debounce (20000 ms)
- Check oil level and change intervals, correct oil level or perform oil change as indicated.
- Check swirl valves.
- Check exhaust backpressure.
- Check particulate filter (visual inspection of end pipe and ceramic filter element).
- Conduct regeneration (possible only during steady-state operation lasting at least 30 minutes. The appropriate service function must be employed to trigger regeneration when this error is present).
Proceed to the nearest BMW Service facility.
Warning light
MIL
After replacing the particulate filter carry out the corresponding service function!
DDE
48D1 - P0471
Debounce (500 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas pressure sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
| IMPORTANT | If additional diagnostic trouble codes related to the engine have been logged (boost pressure hose fallen off, mass airflow control deviation, defect in air-induction system) then these should receive priority attention, because this fault can also occur as a collateral error! |
DDE
48D0 - P0471
Debounce (500 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas pressure sensor.
Warning light
MIL
| IMPORTANT | If additional diagnostic trouble codes related to the engine have been logged (boost pressure hose fallen off, mass airflow control deviation, defect in air-induction system) then these should receive priority attention, because this fault can also occur as a collateral error! |
DDE
4B93 - P2458
Event debounced (1)
Check particulate filter (aging, defect).
Torque limitation, power reduction.
Warning light
MIL
none
DDE
433A - P0238
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace boost-pressure sensor.
Proceed to the nearest BMW Service facility.
Component hazard possible, avoid WOT/full throttle operation.
Warning light
MIL
none
DDE
433B - P0237
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace boost-pressure sensor.
Proceed to the nearest BMW Service facility.
Component hazard possible, avoid WOT/full throttle operation.
Warning light
MIL
none
DDE
3F00 - P0238
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace boost-pressure sensor.
Power reduction.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
3F01 - P0237
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace boost-pressure sensor.
Power reduction.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4D96 - P0473
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas pressure sensor before turbocharger.
Proceed to the nearest BMW Service facility.
Component hazard possible, avoid WOT/full throttle operation.
Warning light
MIL
none
DDE
4D97 - P0472
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas pressure sensor before turbocharger.
Warning light
MIL
none
DDE
4560 - P0087
Debounce (900 ms)
Check the following potential problem sources
- Fuel presupply pressure (low-pressure delivery circuit) is too low (filter obstructed, leak in low-pressure circuit).
- Rail-pressure sensor indicates incorrect value.
- Leakage in high-pressure circuit.
- Injector is sticking open.
- Worn high-pressure pump.
- Worn injector.
- Internal leakage in common rail system.
- External leakage in common rail system.
- Air in common rail system.
Investigate potential problem sources, conduct rail-pressure control system test.
Output governed.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4580 - P0088
Debounce (2000 ms)
Check the following potential problem sources
- Possible faults in fuel pre-supply system: pre-supply pressure is too high.
- Fuel-quantity control valve sticking in open position.
- Fuel-quantity control valve has no power owing to electrical malfunction.
Investigate potential problem sources, conduct rail-pressure control system test.
Output governed.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4590 - P0087
Debounce (300 ms)
Check the following potential problem sources
- Fuel presupply pressure (low-pressure delivery circuit) is too low (filter obstructed, leak in low-pressure circuit).
- Rail-pressure sensor indicates incorrect value.
- Leakage in high-pressure circuit.
- Injector is sticking open.
- Worn high-pressure pump.
- Worn injector.
- Internal leakage in common rail system.
- External leakage in common rail system.
- Air in common rail system.
Investigate potential problem sources, conduct rail-pressure control system test.
Output governed.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
45A0 - P0088
Debounce (240 ms)
Check the following potential problem sources
- Possible faults in fuel pre-supply system: pre-supply pressure is too high.
- Fuel-quantity control valve sticking in open position.
- Fuel-quantity control valve has no power owing to electrical malfunction.
Investigate potential problem sources, conduct rail-pressure control system test.
Output governed.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4600 - P0087
Debounce (800 ms)
Check the following potential problem sources
- Fuel presupply pressure (low-pressure delivery circuit) is too low (filter obstructed, leak in low-pressure circuit).
- Rail-pressure sensor indicates incorrect value.
- Leakage in high-pressure circuit.
- Injector is sticking open.
- Worn high-pressure pump.
- Worn injector.
- Leak in rail-pressure control valve.
- Internal leakage in common rail system.
- External leakage in common rail system.
- Air in common rail system.
Investigate potential problem sources, conduct rail-pressure control system test.
Output governed.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4620 - P0088
Debounce (2000 ms)
Check the following potential problem sources
- Rail-pressure control valve sticking shut.
- Electrical malfunction results in continuous power to the rail-pressure control valve.
- Filter screen in rail-pressure control valve is obstructed.
Investigate potential problem sources, conduct rail-pressure control system test.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4630 - P0087
Debounce (300 ms)
Check the following potential problem sources
- Fuel presupply pressure (low-pressure delivery circuit) is too low (filter obstructed, leak in low-pressure circuit).
- Rail-pressure sensor indicates incorrect value.
- Leakage in high-pressure circuit.
- Injector is sticking open.
- Worn high-pressure pump.
- Worn injector.
- Leak in rail-pressure control valve.
- Internal leakage in common rail system.
- External leakage in common rail system.
- Air in common rail system.
Investigate potential problem sources, conduct rail-pressure control system test.
Attempt to restart the engine after a terminal power-status switch.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4640 - P0088
Debounce (240 ms)
Check the following potential problem sources
- Rail-pressure control valve sticking shut.
- Electrical malfunction results in continuous power to the rail-pressure control valve.
- Filter screen in rail-pressure control valve is obstructed.
Investigate potential problem sources, conduct rail-pressure control system test.
Output governed.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
3F40 - P3000
- At start: 30 ms
In post-operational shutdown phase: 100 ms
- Check wires and plug connections. Check connections for corrosion!
- If wiring and plug connections are OK: Replace rail-pressure sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
3F41 - P3001
- At start: 30 ms
In post-operational shutdown phase: 100 ms
- Check wires and plug connections. Check connections for corrosion!
- If wiring and plug connections are OK: Replace rail-pressure sensor.
Warning light
MIL
none
DDE
3F30 - P0193
Debounce (140 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace rail-pressure sensor.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
3F31 - P0192
Debounce (140 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace rail-pressure sensor.
The error disables regeneration in the particulate filter.
Proceed to the nearest BMW Service facility.
Warning light
MIL_SVS
none
DDE
4BD3 - P207F
Debounce (2000 ms)
- Consult customer to clarify whether water may have used to refill the tank.
If yes: Extract all content from tanks and then refill.
If tanks have not yet been filled an efficiency error is present. This is then an exhaust-gas emissions problem. Fault rectification as for DTC 4D17 which will also be present in this case.
Warning light
MIL
none
DDE
4D11 - P20EE
Event debounced (10)
Depending upon the problem source
- Refill tank (quality of reduction agent).
- Clean/replace (metering module/NOx sensor/SCR converter/particulate filter).
Warning light
MIL
none
DDE
4D12 - P20EE
Event debounced (10)
Depending upon the problem source
- Refill tank.
- Clean/replace (metering valve/NOx sensor/SCR converter/particulate filter).
Warning light
MIL
DDE
4D17 - P20EE
Event debounced (4)
- Refill tank with new fluid
- Use diagnostic system to test SCR converter.
- Check metering valve.
- Check NOx sensors.
- Replace SCR converter
Warning light
KEINE
- Quality (quality determination): Extract contents from tank and then refill.
- NOx sensor before or behind SCR converter (identified by corresponding diagnostic trouble code entry in ECU error memory) furnishing implausible data
- Defective SCR converter, check with SCR converter system test
- Coating on diesel particulate filter (indicated by DTC 4B91)
- Check operation of metering valve.
DDE
4D18 - P20EE
Event debounced (4)
Warning light
KEINE
none
DDE
46E8 - P20EE
Event debounced (8)
Warning light
KEINE
none
DDE
4D16 - P20EE
Event debounced (4)
- Refill SCR system tank with new fluid
- Use diagnostic system to test SCR converter.
- Check metering valve.
- Check NOx sensors.
- Inspect metering module for correct installation position and contamination.
If results of all tests are OK
Replace SCR converter.
Warning light
MIL
- Quality determination: Extract contents from tank and then refill.
- NOx sensor before or behind SCR converter (identified by corresponding diagnostic trouble code entry in ECU error memory) furnishing implausible data
- Defective SCR converter, check with SCR converter system test
- Coating on diesel particulate filter (indicated by DTC 4B91)
- Check operation of metering valve.
DDE
4955 - P229F
Event debounced (1)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace NOx sensor behind SCR converter.
Warning light
MIL
none
DDE
4BB3 - P2201
Event debounced (1)
Warning light
MIL
none
DDE
4BB2 - P2201
Event debounced (1)
Warning light
MIL
none
DDE
46F2 - P204F
Debounce (1000 ms)
- Use diagnostic system to check temperature upstream from SCR converter and then replace as indicated.
- SCR metering system, check pressurization function, replace as indicated.
- If the fault source is a battery replacement or undervoltage: Clear diagnostic trouble codes from ECU error memory.
Warning light
MIL
- Plausibility check on data after 5 minutes at idle: Temperature sensor on engine-side of SCR converter, temperature sensor before oxidation catalyst, temperature sensor before diesel particulate filter
- Check pressure build-up in the SCR metering system test module
DDE
4952 - P20E9
Debounce (0 ms)
- Use diagnostic system to check pressurization level.
- Check plausibility of temperature and pressure levels within the active tank, if implausible values are present: Check ground wires for short circuits to B+. Replace wires and plug connections.
- Replace delivery module.
Warning light
MIL
none
DDE
4D02 - P20E8
Debounce (0 ms)
Depends on cause
- Refill reduction medium.
- Replace any leaking components.
- Replace delivery module.
Warning light
MIL
Is reduction agent in the tank (check tank levels)?
In winter: Is the tank completely frozen, meaning that no reduction agent is at the pick-up point?
Is the delivery module drawing air between the pick-up point in the tank and the delivery module? Is a major leak present in the metering system (perform SCR system test and visual inspection for leaks)? Is the metering module sticking open?
DDE
463E - P20E9
Event debounced (3)
If ice has formed, thaw system
- Allow the engine to idle while the vehicle remains parked, the heater units will be activated automatically. Determine whether the fault is still present once the system has thawed.
If no ice is present
- Replace delivery module.
Warning light
MIL
none
DDE
4804 - P20E8
Event debounced (1)
Depends on cause
- Refill reduction medium.
- Replace leaking components.
- Replace delivery module.
Warning light
MIL
Is reduction agent in the tank (check tank levels)?
In winter: Is the tank completely frozen, meaning that no reduction agent is at the suction point?
Is the delivery module drawing air between the suction point in the tank and the delivery module? Is a major leak present in the metering system (perform SCR system test and visual inspection for leaks)? Is the metering module sticking?
DDE
4809 - P20A5
Event debounced (3)
Replace delivery module.
Warning light
MIL
If the error occurs in combination with 4D02 and 4804 then the pump in the delivery module is defective (the pump is also employed for rapid depressurization).
DDE
4D35 - P208E
Event debounced (150)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use the diagnostic tester to activate the metering module and then listen for a ticking sound.
- If an audible noise is present delete the stored DTCs from the error memory. The metering module is not defective.
- If no sound is heard, remove the metering module and rinse it with water to remove crytallized deposits. Install the module again and activate it using the diagnostic tester. If a ticking sound is now audible the module is once again operational. Delete stored DTCs from error memory.
- No noise is audible replace the metering module.
Warning light
MIL
none
DDE
4D20 - P20A5
Event debounced (1)
- Use the diagnostic system to activate the suction valve.
- Replace delivery module.
Warning light
MIL
none
DDE
4D10 - P209F
No debouncing.
- Use diagnostic system to check active tank temperature sensor's transmitted data for plausibility.
- Check active tank heating system: Transmit activation signal to heater and check current.
- Check wires and plug connections at active tank heater and active tank temperature sensor.
- Replace the active tank.
Warning light
MIL
Specified current during activation: at least 400 uA.
If defects related to the temperature sensor and/or wiring are present, then diagnostic trouble codes for the sensors must also be logged.
DDE
4BF4 - P244B
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas differential-pressure sensor.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4B7E - P0473
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas pressure sensor before turbocharger.
Proceed to the nearest BMW Service facility.
Component hazard possible.
Warning light
MIL
none
DDE
4020 - P2033
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor before particulate filter.
Warning light
MIL
none
DDE
4714 - P242D
Debounce (1000 ms) 1000 ms.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor before the SCR converter.
Warning light
MIL
none
DDE
4704 - P204D
Debounce (400 ms)
- Check wires and plug connections. The power-supply voltage is up to 4.9V.
- If wiring and plug connections are OK
- Check pressure sensor.
- Replace delivery module.
Warning light
MIL
For access reasons, start by checking wires between transfer plug and DDE (E70): behind the front bumper, E90): behind left rear wheel).
DDE
4BF9 - P244A
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas differential-pressure sensor.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4B7F - P0472
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas pressure sensor before turbocharger.
Proceed to the nearest BMW Service facility.
Component hazard possible.
Warning light
MIL
none
DDE
4021 - P2032
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor before particulate filter.
Warning light
MIL
none
DDE
4719 - P242C
Debounce (1000 ms) 1000 ms.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor before the SCR converter.
Warning light
MIL
none
DDE
4709 - P204C
Debounce (400 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Check pressure sensor.
- Replace delivery module.
Warning light
MIL
When no pressure is present the sensor transmits a signal of 500 mV. If the value is not transmitted then the sensor or the power supply is defective.
For access reasons, start by checking wires between transfer plug and DDE (E70): behind the front bumper, E90): behind left rear wheel).
DDE
4670 - P0641
Debounce (80 ms)
Check all of the components connected to sensor power-supply voltage 1 for corresponding diagnostic trouble codes (short circuit).
If this kind of diagnostic trouble code is entered in the ECU
Conduct fault diagnosis for the affected component.
If no diagnostic trouble code of this type has been logged
Replace DDE control module.
Warning light
MIL_SVS
none
DDE
4680 - P0651
Debounce (80 ms)
Check all of the components connected to sensor power-supply voltage 2 for corresponding diagnostic trouble codes (short circuit).
If this kind of diagnostic trouble code is entered in the ECU
Conduct fault diagnosis for the affected component.
If no diagnostic trouble code of this type has been logged
Replace DDE control module.
Warning light
MIL
none
DDE
4690 - P0697
Debounce (80 ms)
Check all of the components connected to sensor power-supply voltage 3 for corresponding diagnostic trouble codes (short circuit).
If this kind of diagnostic trouble code is entered in the ECU
Conduct fault diagnosis for the affected component.
If no diagnostic trouble code of this type has been logged
Replace DDE control module.
Warning light
MIL
none
DDE
4830 - P0113
Debounce (200 ms)
Warning light
MIL
none
DDE
4831 - P0112
Debounce (200 ms)
Warning light
MIL
none
DDE
4BA0 - P0113
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace mass-airflow sensor.
Warning light
MIL
none
DDE
436A - P007C
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace charge-air temperature sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4390 - P007D
Debounce (150 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace charge-air temperature sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4391 - P007C
Debounce (150 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace charge-air temperature sensor.
Proceed to the nearest BMW Service facility.
Warning light
MIL
none
DDE
4D76 - P007B
- None.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace charge-air temperature sensor.
Warning light
MIL
If electrical sensor faults are present (short circuit, open circuit) these should also be logged.
DDE
4D90 - P040C
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor behind EGR cooler.
Warning light
MIL
none
DDE
4D87 - P040D
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor behind EGR cooler.
Warning light
MIL
none
DDE
4D88 - P040C
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor behind EGR cooler.
Warning light
MIL
none
DDE
498C - P041C
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor behind low-pressure EGR cooler.
Warning light
MIL
none
DDE
4D82 - P041D
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor behind low-pressure EGR cooler.
Warning light
MIL
none
DDE
4D83 - P041C
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor behind low-pressure EGR cooler.
Warning light
MIL
none
DDE
4D71 - P0545
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor before catalytic converter.
Warning light
MIL
none
DDE
4987 - P0546
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Exhaust-gas temperature sensor before oxidation catalyst.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4986 - P0545
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Exhaust-gas temperature sensor before oxidation catalyst.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4D6C - P2032
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Exhaust-gas temperature sensor before the particulate filter.
Warning light
MIL
none
DDE
4677 - P0638
Debounce (0 ms)
Warning light
MIL
none
DDE
4687 - P0638
Debounce (0 ms)
Warning light
MIL
none
DDE
4697 - P0638
Debounce (0 ms)
Warning light
MIL
none
DDE
49E7 - P0638
Debounce (0 ms)
Warning light
MIL
none
DDE
43E2 - P2620
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace throttle-valve actuator.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
43E3 - P0638
Debounce (50 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE ECU.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
43C0 - P2622
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace throttle-valve actuator.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
43D1 - P2621
Debounce (2400 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace throttle-valve actuator.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4707 - P0243
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace wastegate valve vacuum converter.
The error disables regeneration in the particulate filter.
Warning light
MIL_SVS
none
DDE
4708 - P0244
Debounce (50 ms)
E90-M57D30T2-AT-LEVII
Debounce (220 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE control module.
The error disables regeneration in the particulate filter.
Warning light
MIL_SVS
none
DDE
46E5 - P0246
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace wastegate valve vacuum converter.
The error disables regeneration in the particulate filter.
Warning light
MIL_SVS
none
DDE
46F6 - P0245
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace wastegate valve vacuum converter.
The error disables regeneration in the particulate filter.
Warning light
MIL_SVS
none
DDE
41A2 - P0045
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: With single-stage boost: Replace charge-air pressure controller. With multi-stage boost: Replace turbine control flap pressure converter.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
41A3 - P0046
Debounce (220 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE control module.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4180 - P0048
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: With single-stage boost: Replace charge-air pressure controller. With multi-stage boost: Replace turbine control flap pressure converter.
The error disables regeneration in the particulate filter.
Warning light
MIL
none
DDE
4191 - P0047
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: With single-stage boost: Replace charge-air pressure controller. With multi-stage boost: Replace turbine control flap pressure converter.
The error disables regeneration in the particulate filter.
Warning light
MIL_SVS
none
DDE
4D5C - P242C
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace exhaust-gas temperature sensor before the SCR converter.
Warning light
MIL
none
DDE
47FE - P2062
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace metering module.
Warning light
MIL
none
DDE
47FF - P202F
Debounce (1000 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
- 2. Replace DDE control module.
Warning light
MIL
none
DDE
4C7C - P2064
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace SCR metering module.
Warning light
MIL
none
DDE
47F4 - P2064
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to check metering module.
- Replace metering module.
Warning light
MIL
none
DDE
4C7B - P2063
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace SCR metering module.
Warning light
MIL
none
DDE
47F9 - P2063
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic tester to test metering module.
- Replace metering module.
Warning light
MIL
none
DDE
4603 - P10DA
Event debounced (1)
- If the DTC 45F1 also appears: Replace power switch.
- Repair sources of electrical tracking and arcing (moisture in the wiring or plug connections).
- Check the resistance in the metering line heating system.
- Replace power switch.
- Replace the metering line.
Warning light
MIL
Resistance in the metering line heating system
E70: 3.8 - 4.4 ohms
E90: 1.5 - 1.7 ohms
DDE
4602 - P10DB
Event debounced (1)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Check resistance in the metering line heating unit
- Replace metering line heating unit.
Warning light
MIL
Resistance in the metering line heating system
E70: 3.8 - 4.4 ohms
E90: 1.5 - 1.7 ohms
DDE
4601 - P20B5
Event debounced (1)
- Check resistance of delivery module heater unit.
- Replace delivery module.
Warning light
MIL
Delivery module heating unit resistance
2.9 - 5.5 ohms
DDE
45F1 - P20B8
Event debounced (1)
- If the DTC 4603 also appears at the same time: Replace power switch. Repair sources of electrical tracking and arcing (moisture in the wiring or plug connections).
- Check resistance of the delivery module's heating system.
- Replace power switch.
Warning light
MIL
If the new version of the power switch is installed measure the resistance of the delivery module heating system's circuits.
Delivery module heater resistance
2.9 - 5.5 ohms
DDE
4C72 - P20B5
Debounce (15000 ms)
- Check the control wire and the diagnostic wire.
- If wiring and plug connections are OK
- Check plug connections for moisture.
- Use diagnostic system to test heating systems.
- Replace power switch.
Warning light
MIL
The power switch transmits an activation signal to all heaters. The first heater circuit is for the active tank heater, the second heater circuit is for the delivery module and the metering line.
The control wire should not be in contact with ground or B+ when the DDE and power switch are unplugged.
DDE
49E5 - P20B6
Debounce (2200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to activate the heater.
- Replace metering line.
Warning light
MIL
Measure resistance in the metering line
Can only occur with earlier power switch installed prior to 09/2009.
DDE
4968 - P20B6
Event debounced (1)
- 1.a) If this error appears together with DTC 49E5: Fault in metering wire, check resistance.
- 1.b) If the error appears alone check the resistance in the delivery module heating system.
- 2. Defective delivery module heating system.
- 3. Metering line heater defective.
Warning light
MIL
none
DDE
49E2 - P20B5
Event debounced (1)
- Check resistance of heater elements.
- Check heater wires for short circuits to ground.
Warning light
MIL
none
DDE
49ED - P202A
Debounce (15000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace power switch.
Warning light
MIL
Check the control-activation wire for a short circuit to ground. The power switch transmits an activation signal to all heaters. The first heater circuit is for the active tank heater, the second heater circuit is for the delivery module and the metering line.
The control-activation wire should have no continuity with either ground or positive when disconnected from the DDE and the power switch.
DDE
49E1 - P209F
Debounce (2200 ms)
Top up reduction agent and check fluid level using the diagnostic system.
If it is not possible to repair the problem by refilling with reduction agent
- Check wires and plug connections.
- If wiring and plug connections are OK
- Check the heating system using the diagnostic system.
- Determine the level of electrical resistance in the tank's heating system.
- Check active tank heating system
- Replace power switch.
Warning light
MIL
Refill reduction agent to avoid air bubble. Repeat activation of heater and check current signal (specified: 5 - 9 A) Check with tester.
Tank heating system resistance specifications
1.5 - 2.4 ohms
DDE
49DC - P202C
Event debounced (1)
- Check resistance of heater elements.
- Check heater wires for short circuits to ground.
Warning light
MIL
Measure the resistance of the active tank's heating system at the power switch: Specified readings: 1.5 - 2.4 ohms
DDE
46C4 - P20BD
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Inspect fuse.
- Replace relay.
- Replace power switch.
Warning light
MIL
Heater circuit 2 is for the metering wire and delivery module.
If DTC 4C72 or 49ED is logged, this is a collateral error and shuts down the relay. Repair this malfunction and delete stored DTCs from the error memory.
DDE
46C9 - P20C0
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to activate the heater.
- Replace power switch.
Warning light
MIL
Heater circuit 2 is for the metering wire and delivery module.
DDE
46CE - P20BF
Debounce (1000 ms)
- Check wires and plug connections.
- Defective power switch.
- Defective fuse.
- Defective relay.
Warning light
MIL
Heater circuit 2 is for the metering wire and delivery module.
If DTC 4C72 or 49ED is logged, this is a collateral error and shuts down the relay. Repair this malfunction and delete stored DTCs from the error memory.
DDE
46DE - P20C0
Debounce (50 ms)
E90-M57D30T2-AT-LEVII
Debounce (500 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Check resistances in heating circuit.
- Inspect fuse.
- Use diagnostic system to test heating systems.
- Replace power switch.
- Replace metering line heater.
Warning light
MIL
Heater circuit 2 is for the metering wire and delivery module.
Perform electrical checks of resistances in heater circuit at power switch. Heater circuit metering wire specifications
E70: 3.8 - 4.4 ohms
E90: 1.5 - 1.7 ohms
Heater circuit delivery module specifications
2.9 - 5.5 ohms
DDE
46E4 - P202A
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnosis to activate heating systems.
- Inspect fuse.
- Replace power switch (relay).
Warning light
MIL
Heater circuit 2 is for the metering wire and delivery module.
If DTC 4C72 or 49ED is logged, this is a collateral error and shuts down the relay. Repair this malfunction and delete stored DTCs from the error memory.
DDE
46E9 - P202C
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnosis to activate heating systems.
- Replace power switch.
Warning light
MIL
none
DDE
46EE - P202B
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnosis to activate heating systems.
- Check fuses.
- Replace power switch.
Warning light
MIL
Heater circuit 2 is for the metering wire and delivery module.
If DTC 4C72 or 49ED is logged, this is a collateral error and shuts down the relay. Repair this malfunction and delete stored DTCs from the error memory.
DDE
46D4 - P202A
Debounce (50 ms)
E90-M57D30T2-AT-LEVII
Debounce (500 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Check resistances in heating circuits.
- Inspect fuse.
- Use diagnostic system to test heating systems.
- Replace power switch.
- Check active tank heating system
Warning light
MIL
Perform electrical checks of resistances in heater circuit at power switch. Active tank heating circuit specifications
1.5 - 2.4 ohms
DDE
4BCD - P21A9
Debounce (30000 ms)
If the reduction agent is frozen: Allow the tank to thaw.
If the reduction agent is not frozen
Completely fill tank.
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to check fluid level.
- Replace passive tank.
Warning light
MIL
When a plausibility error is present the higher level sensor recognizes a fluid level (conductivity) while the lower level sensor does not.
In winter: For example, when a frozen passive tank is refilled, the lower sensor might be encapsulated in ice, while the upper sensor would recognize conductivity.
The level sensor's conductivity can also be assessed as follows
- Use the diagnostic system to read out the tank fluid level.
- Delete the DTCs from the error memory and carry out the quick-test procedure for the individual control modules. Watch for new DTC entries.
If the DTC 4BCB is present at the same time it must be repaired first.
DDE
4BCC - P21A8
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to check sensor signal.
- Replace passive tank.
Warning light
MIL
Measure the resistance levels at the fluid-level sensor between pins 1 and 2, and between pins 3 and 4. The tank must be empty for this measurement.
Normal resistance with empty tank: 10 kOhm.
Resistance levels in excess of 12 kOhms indicate that the fluid-level sensor is defective.
DDE
4BCB - P21A8
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace electronic processing circuitry for the passive tank's fluid-level sensors.
Warning light
MIL
none
DDE
47EE - P208A
Debounce (8000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Check fuse
- Use diagnostic system to check pressurization.
- Replace delivery module.
Warning light
MIL
- The wire that activates the delivery pump is open. No 12-volt power supply is present.
- Open circuit in voltage supply to active tank. In this case the DTC 46AF is also present.
DDE
47E4 - P208D
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to test delivery module.
- Replace delivery module.
Warning light
MIL
none
DDE
47E9 - P208C
Debounce (8000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to test delivery module.
- Replace delivery module.
Warning light
MIL
If the wires are OK and the pump indicates a short circuit to ground replace the delivery module.
DDE
4D51 - P204D
Debounce (10000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to check pressure sensor.
- Replace delivery module.
Warning light
MIL
This fault is the result of a wiring defect.
DDE
4D36 - P204B
Debounce (600 ms)
- Use diagnostic system to test the pressure sensor.
- Replace delivery module.
Warning light
MIL
none
DDE
46AF - P20A0
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to activate switch valve.
- Check switch valve resistance.
- Inspect fuse.
- Replace delivery module.
Warning light
MIL
Specification for coil resistance in the delivery module: 9-13 ohms.
DDE
46BF - P20A3
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace delivery module.
Warning light
MIL
none
DDE
46CF - P20A2
Debounce (1000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Replace delivery module.
Warning light
MIL
none
DDE
4BAD - P203B
Debounce (15000 ms)
- If the reduction agent is frozen: Allow the active tank to thaw. Delete the diagnostic trouble code from the ECU.
- If the reduction agent is not frozen: Check wires and plug connections. If wiring and plug connections are OK: Use diagnostic system to check fluid level in active tank. Check to determine whether DTC 4BAB is present. Repair this first. Replace the active tank.
Warning light
MIL
In winter: Allow the tank to thaw. Check level. Delete the diagnostic trouble code from the ECU.
If the DTC 4BAB is present at the same time it must be repaired first.
DDE
4BAC - P203A
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use the diagnostic system to check the fluid levels.
- Replace the active tank.
Warning light
MIL
Measure the resistance levels on the level sensor between reference (pin 1) and tank level 1-3 (pins 2-4). The tank must be empty for the measurement.
Nominal value with tank empty: 10 kOhm
Resistance levels in excess of 12 kOhms indicate a defective fluid-level sensor.
DDE
4BAB - P203A
Debounce (2000 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use the diagnostic system to check the fluid sensor.
- Replace the electronic processing circuitry for the active tank's fluid-level sensors.
Warning light
MIL
none
DDE
46F4 - P205D
Debounce (600 ms)
- 1. Check wires and plug connections.
- 2. If wiring and plug connections are OK
- 4. Use diagnostic module to test temperature sensor's plausibility.
- 3. Replace active tank temperature sensor.
Warning light
MIL
Specified active tank temperature sensor resistance: 12.3-12.6 kOhms at 20 °C.
DDE
46F9 - P205C
Debounce (600 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK
- Use diagnostic system to test temperature sensor.
- Replace sensor
Warning light
MIL
none
DDE
492C - P205B
Debounce (16000 ms)
- Fill active tank.
- Execute "refill recognition" service function.
- Use the diagnostic system to read out the tank's contents and temperature and the data for the transfer pump and then examine them. Delete the DTC is plausible figures are indicated.
- Replace temperature sensor.
- Replace the transfer-pump assembly.
Warning light
MIL
In winter
The temperature sensor is defective if a valid level signal is present at temperatures below -20°C.
DDE
4D32 - P205B
Debounce (2000 ms)
- Use diagnostic system to check temperature sensor for plausible reading.
- Replace temperature sensor.
Warning light
MIL
none
DDE
4D33 - P205B
Debounce (2000 ms)
- Use diagnostic system to check temperature sensor for plausible reading.
- Replace temperature sensor.
Warning light
MIL
none
DDE
46A7 - P200A
Debounce (0 ms) Following detection of an error window the error counter is raised and the error timer is started.
If an additional error is recognized within the time 6600 ms the error counter is raised again and the timer is restarted.
If no error is recognized within the time, the error counter is reset to zero and the timer is stopped.
The diagnostic trouble code is logged when the error counter reaches the limit 3.
Check the swirl-valve actuator for freedom of movement, replace as indicated.
Warning light
MIL_SVS
none
DDE
46B7 - P200A
Debounce (0 ms) Following detection of an error window the error counter is raised and the error timer is started.
If an additional error is recognized within the time 6600 ms the error counter is raised again and the timer is restarted.
If no error is recognized within the time, the error counter is reset to zero and the timer is stopped.
When the error counter reaches the limit 3 the diagnostic trouble code is logged.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace swirl-valve actuator.
Warning light
MIL
none
DDE
46C7 - P200A
Debounce (0 ms) Following detection of an error window the error counter is raised and the error timer is started.
If an additional error is recognized within the time 6600 ms the error counter is raised again and the timer is restarted.
If no error is recognized within the time, the error counter is reset to zero and the timer is stopped.
When the error counter reaches the limit 3 the diagnostic trouble code is logged.
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace swirl-valve actuator.
Warning light
MIL
none
DDE
49F7 - P200A
Debounce (0 ms) Following detection of an error window the error counter is raised and the error timer is started.
If an additional error is recognized within the time 6600 ms the error counter is raised again and the timer is restarted.
If no error is recognized within the time, the error counter is reset to zero and the timer is stopped.
When the error counter reaches the limit 1 the diagnostic trouble code is logged.
Check swirl-valve actuator.
Warning light
MIL
none
DDE
4152 - P2008
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace swirl-valve actuator.
Warning light
MIL
none
DDE
4153 - P200A
Debounce (220 ms)
Check E-Box fan/DDE cooling. If E-Box fan/DDE cooling are OK
Replace DDE control module.
Warning light
MIL
none
DDE
4130 - P2010
Debounce (220 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace swirl-valve actuator.
Warning light
MIL
none
DDE
4141 - P2009
Debounce (10200 ms)
- Check wires and plug connections.
- If wiring and plug connections are OK: Replace swirl-valve actuator.
Warning light
MIL
none
DDE
3F53 - P0501
Debounce (2000 ms)
Warning light
MIL
none
DDE
3F62 - P0500
Debounce (1500 ms)
Troubleshooting in transmitting control module.
Warning light
MIL
none