TROUBLE SHOOTING
Note. See TROUBLE SHOOTING - BASIC PROCEDURES article in the GENERAL TROUBLE SHOOTING section.
WIRING CONTINUITY TEST
- Connect voltmeter between generator B+ terminal and ground. Voltmeter should indicate battery voltage. If battery voltage is not indicated, check wiring between generator and battery.
- Turn ignition on and ensure generator indicator light comes on. If light does not come on, check indicator light bulb and wiring between generator and warning light.
OUTPUT TEST
- Ensure connections at battery, generator, and starter are clean and tight. Ensure generator, engine and body are properly grounded.
- Ensure generator drive belt is tight and in good condition. Connect charging system tester according to manufacturer's instructions. Connect voltmeter leads to battery terminals.
- Start and operate engine at 3000 RPM. Adjust carbon pile on tester to obtain maximum generator output. DO NOT allow voltage to drop to less than 12.6 volts.
- Generator output should equal generator rated output. If reading is 16-20 amps less than generator rating, replace regulator and retest. If output is still low, repair or replace generator.
REGULATOR CONTROL VOLTAGE TEST
- Connect charging system tester according to manufacturer's instructions. Connect voltmeter leads to battery terminals. Start and operate engine at 3000 RPM.
- Operate engine until voltage stops rising. Voltage should be 13.5-14.2 volts. If reading is incorrect, remove regulator and ensure brushes are longer than 0.198" (5.0 mm). Replace if necessary.
- If brushes are okay and regulator fails to keep voltage within specified limits, replace regulator and retest. If voltage is still incorrect, repair or replace generator.