Removing
- Remove left and right plenum chamber covers.
- Remove dust and pollen filter --> «Dust and pollen filter, removing and installing»(ref-289225-S02097241612008062700000) .
- Remove dome brace with reinforcement to cowl panel trim. --> «40 - FRONT SUSPENSION»(ref-289219-S31806228072008062700000)
- Switch on ignition and set air conditioner to fresh-air mode (e.g. by "Defrost" setting on Climatronic Control Module J255)
Note. To gain access to bolts - A - , air flow flap must be open.
Scheme 43
- Remove bolts - A -.
- Switch off ignition.
- Now remove the remaining screws - arrows -.
Scheme 44
- Release fasteners for wiring harness - A - on left and right of air conditioner.
- Take off air intake shroud with air flow flap.
- If necessary for further work, open remaining wiring harness fasteners at air conditioner.
Scheme 45
- Remove bolts - A -.
- Remove cover - B -.
- Remove temperature sensor from intake housing --> «Fresh Air Intake Duct Temperature Sensor G89 removing and installing»(ref-289225-S40864103962008062700000)
- Remove Air Flow Flap Motor V71 --> «Air Flow Flap Motor V71 with Back Pressure Flap Motor Position Sensor G113 , removing and installing»(ref-289225-S28604062512008062700000) .