Vibration damper, removing and installing
Removing
- Remove front sound insulation by loosening fasteners - 1 -.
Note. Ignore items - 2, 3, 4 -.
- Remove bolts - arrows - and remove coolant pipes to ATF cooler with coolant hoses - 1 through 4 - connected from lock carrier.
- Loosen 8 bolts - arrow - on vibration damper several turns by counterholding on generator belt pulley centered nut with open end wrench.
- Remove ribbed belt --> «Ribbed belt, removing and installing»(ref-289203-S08720727742008062700000)
- Remove bolts - arrows - and remove vibration damper.
Installing
- Tightening torque --> «Vibration damper tightening sequence»(ref-289203-S31530453332009012200000)
Installation is in reverse order of removal, note the following
Note. Replace bolts which have been tightened to torque. Installation of harmonic balancer is only possible in one position - note alignment bushing.
- Install ribbed belt --> «Ribbed belt, removing and installing»(ref-289203-S08720727742008062700000) .