Contents Section: On Board Diagnostic (OBD) - 5 Spd. Automatic Transmission (01l, Awd) All sections

Electrical testing Audi A8 D2 рестайлинг

Electrical testing

  1. For testing use a Fluke 83 multimeter or equivalent.
  2. The specified values are valid for an ambient temperature of 10-40° C (50-104° F).
  3. If measured values deviate from specified values, determine the malfunction using the appropriate wiring diagram.
  4. If measured values deviate only slightly from specified values, clean the sockets and connectors of the test unit and test leads and repeat the test.
  5. Before replacing components, check the respective wiring and connectors. Repeat resistance tests when values are below 10°.
  6. To connect test units, use test box VAG 1598/20.
  7. The terminal numbers of the connector and the socket numbers of test box VAG 1598/20 must be uniform. See «MULTI-PIN CONNECTOR (88-PIN CONNECTOR) OF TCM -J217- (SOCKET NUMBERS ON VAG 1598/20)»(/audi/a8/d2-1999-2002/remont/automatic-trans/#on-board-diagnostic-obd-5-spd-automatic-transmission-01l-awd__multi-pin-connector-88-pin-connector-of-tcm) .
CAUTIONIn order to avoid interference with electronic components, switch to the correct test range on the multimeter before connecting the test leads.
  1. Battery Positive Voltage (B+) OK
  2. Fuses for Transmission Control Module (TCM) OK
  3. Fuses for components to be checked OK
  4. Ground (GND) connections OK
  1. Check battery GND strap and GND strap between body and transmission.
  2. Check GND connectors for TCM.

See appropriate System Wiring Diagrams article.