Maximum time interval
This function is used to set a fixed maximum time in days in the instrument cluster for the SRI.
Indicated on display
VAG 1551 Scan Tool Display - Maximum Time Interval, Instrument Cluster With Maintenance Interval Extension (1 Of 9). Scheme 306
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
VAG 1551 Scan Tool Display - Maximum Time Interval, Instrument Cluster With Maintenance Interval Extension (2 Of 9). Scheme 307
- Press -Q- button to confirm input.
Indicated on display
VAG 1551 Scan Tool Display - Maximum Time Interval, Instrument Cluster With Maintenance Interval Extension (3 Of 9). Scheme 308
- Press buttons -4- and 4-.
- Press -Q- button to confirm input.
- Indicated on display. The display indicates the maximum time interval in days to the next service (for example, 365 represents 365 days).
Note. The adaptation value input must match the value in the table under MALFUNCTION MESSAGE "DEF" ON TRIP ODOMETER DISPLAY . The currently valid specifications can be found in the "Maintenance" book. Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day. When replacing instrument cluster, this value is already set. Values can only be input directly using the scan tool keypad. If an incorrect value is input, the "Adaptation" function is terminated and must be re-initiated.
- Press --> button.
- Indicated on display (Scheme 310): VAG 1551 Scan Tool Display - Maximum Time Interval, Instrument Cluster With Maintenance Interval Extension (5 Of 9)
- Input specified value using keypad, filling initial positions with "0".
Input value: for example 365 days
Keypad input: 00365
Scheme 309
Scheme 310
- Indicated on display see scheme 327: VAG 1551 Scan Tool Display - Maximum Time Interval, Instrument Cluster With Maintenance Interval Extension (6 Of 9)
- Press -Q- button to confirm input.
- Indicated on display see scheme 328: VAG 1551 Scan Tool Display - Maximum Time Interval, Instrument Cluster With Maintenance Interval Extension (7 Of 9)
- Press -Q- button to confirm input.
- Indicated on display see scheme 329: VAG 1551 Scan Tool Display - Maximum Time Interval, Instrument Cluster With Maintenance Interval Extension (8 Of 9)
- Press -Q- button to confirm input.
- Indicated on display see scheme 330: VAG 1551 Scan Tool Display - Maximum Time Interval, Instrument Cluster With Maintenance Interval Extension (9 Of 9)
- End adaptation of maximum time interval by pressing the --> button.