Engine Controls - Sensor Operating Range Charts Acura Integra II

Sensor Range Charts ~101 words

INTRODUCTION

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.

Note. Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.

Temperature °F (°C)Resistance (Ohms)
-4 (-20)15,000-18,000
68 (20)2000-4000
176 (80)
Integra200-400
Legend300-400
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

COOLANT TEMP (TW) SENSOR RESISTANCE TEST (1)

ApplicationResistance (Ohms)
Integra
CRANK Sensor350-700
CYL Sensor350-700
TDC Sensor350-700
Legend
CRANK Sensor600-950
CYL Sensor600-950
(1) See appropriate SYSTEM/COMPONENT TESTS article in the ENGINE PERFORMANCE Section to identify sensor terminals.
(1)See appropriate SYSTEM/COMPONENT TESTS article in the ENGINE PERFORMANCE Section to identify sensor terminals.

DISTRIBUTOR SENSORS RESISTANCE TEST (1)

PositionApproximate Volts
Fully Closed1.0
Fully Open4.5
(1) On Integra, measure voltage between terminals C8 (positive) and C12 (negative). On Legend, measure voltage between terminals D12 (positive) and D22 (negative). Voltage should increase smoothly as vacuum is applied.
(1)On Integra, measure voltage between terminals C8 (positive) and C12 (negative). On Legend, measure voltage between terminals D12 (positive) and D22 (negative). Voltage should increase smoothly as vacuum is applied.

EGR LIFT SENSOR VOLTAGE TEST (1)

Temperature °F (°C)Resistance (Ohms)
-4 (-20)15,000-18,000
68 (20)2000-4000
176 (80)
Integra200-400
Legend300-400
(1) Measure resistance across sensor terminals.
(1)Measure resistance across sensor terminals.

INTAKE AIR TEMPERATURE (TA) SENSOR RESISTANCE TEST (1)

Vacuum Applied (In. Hg)Volts
02.8-3.0
52.3-2.5
101.8-2.0
151.3-1.5
20.8-1.0
25.3-.5
(1) On Integra, measure voltage between ECU terminals C11 (positive) and C12 (negative). On Legend, measure voltage between ECU terminals D17 (positive) and D21 (negative)
(1)On Integra, measure voltage between ECU terminals C11 (positive) and C12 (negative). On Legend, measure voltage between ECU terminals D17 (positive) and D21 (negative)

MAP SENSOR VOLTAGE TEST (1)

ConditionVolts
Lean.1
Rich.9
(1) Measure voltage between ground and O2 sensor terminal using a high- impedance DVOM.
(1)Measure voltage between ground and O2 sensor terminal using a high- impedance DVOM.

OXYGEN SENSOR VOLTAGE TEST (1)

PositionApproximate Volts
Fully Closed.1-.5
Fully Open4.5-4.8
(1) On Integra, measure resistance between terminals C7 (positive) and C12 (negative). On Legend, measure resistance between terminals D11 (positive) and D22 (negative). Voltage should increase smoothly as throttle is opened.
(1)On Integra, measure resistance between terminals C7 (positive) and C12 (negative). On Legend, measure resistance between terminals D11 (positive) and D22 (negative). Voltage should increase smoothly as throttle is opened.

THROTTLE ANGLE SENSOR VOLTAGE TEST (1)