Removal & Installation
Disconnect negative battery cable. Loosen air filter housing. Remove solenoid valve from air filter housing. Remove air filter housing. Remove starter motor bracket bolt. Disconnect electrical connector. Remove 2 mounting bolts. Remove starter. To install, reverse removal procedure. Tighten mounting bolts to 29.5 ft. lbs. (40 N.m). Tighten starter motor bracket bolt to 51 INCH lbs. (6 N.m).