Engine Controls - Sensor Operating Range Charts Volvo S70 I

Sensor Range Charts ~126 words

INTRODUCTION

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.

Note. Perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance unless otherwise instructed in test procedure.

SENSOR RANGE CHARTS

Pressure - psi (kPa)Voltage
2.9 (20).3
5.8 (40)1.5
8.7 (60)2.5
11.6 (80)3.5
14.5 (100)4.5

ATMOSPHERIC PRESSURE SENSOR VOLTAGE (C70, S70 & V70)

Temperature - °F (°C)Ohms
32 (0)7300
68 (20)2800
176 (80)300
212 (100)150

COOLANT TEMPERATURE SENSOR RESISTANCE

ApplicationOhms
S90 & V90 (1)1000
(1) Resistance is measured between terminals No. 1 and 3.
(1)Resistance is measured between terminals No. 1 and 3.

CO POTENTIOMETER RESISTANCE (S90 & V90)

ApplicationOhms
C70, S70 & V70260-340
S90 & V90240-400

ENGINE SPEED (RPM) SENSOR RESISTANCE

ApplicationOhms
All Models15.6-16.2

FUEL INJECTOR RESISTANCE

ApplicationOhms
All Models (1)10-14
(1) Resistance is measured between terminals No. 1 and 2, or No. 2 and 3.
(1)Resistance is measured between terminals No. 1 and 2, or No. 2 and 3.

IDLE AIR CONTROL VALVE (COIL) RESISTANCE

Temperature - °F (°C)Ohms
68 (20)2500

INTAKE AIR TEMPERATURE RESISTANCE (C70, S70 & V70)

ApplicationOhms
S90 & V90 (1)2.5-4
(1) Resistance is measured between terminals No. 2 and 3.
(1)Resistance is measured between terminals No. 2 and 3.

MASS AIRFLOW (MAF) SENSOR RESISTANCE (S90 & V90)

Temperature - °F (°C)Ohms
14 (-10)2190-2270
32 (0)1390-1420
50 (10)890-930
68 (20)590-630
86 (30)400-430
104 (40)270-300

OUTSIDE TEMPERATURE SENSOR RESISTANCE (C70, S70 & V70)

Temperature - °F (°C)Ohms
C70, S70 & V70 Turbo (1)
68 (20)1.5-2.5
660 (350)6-10
C70, S70 & V70 Non-Turbo, & S90 & V90 (1)
68 (20)3
660 (350)13
(1) Resistance is measured between terminals No. 4 and 3.
(1)Resistance is measured between terminals No. 4 and 3.

OXYGEN SENSOR HEATER RESISTANCE

ApplicationOhms
C70, S70 & V70 (1)
Idle900-1100
Full Load2300-2900
S90 & V90 (1)
Idle1000
Full Load2600
(1) Resistance is measured between terminals No. 1 and 3.
(1)Resistance is measured between terminals No. 1 and 3.

THROTTLE POSITION SENSOR RESISTANCE