INTRODUCTION
Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a diagnostic trouble code, but it may cause driveability problems.
Note. Unless stated otherwise in test procedure, perform all resistance and voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
| Temperature °F (°C) | Ohms |
|---|---|
| 86 (30) | 1500-2000 |
| 104 (40) | 1000-1500 |
| 122 (50) | 800-1000 |
| 140 (60) | 500-700 |
| 158 (70) | 375-500 |
| 176 (80) | 275-375 |
| 194 (90) | 225-275 |
ENGINE COOLANT TEMPERATURE (ECT) SENSOR RESISTANCE
| Temperature °F (°C) | (1) Ohms |
|---|---|
| 86 (30) | 1500-2000 |
| 104 (40) | 1000-1500 |
| 122 (50) | 800-1000 |
| 140 (60) | 500-700 |
| 158 (70) | 375-500 |
| 176 (80) | 275-375 |
| 194 (90) | 225-275 |
| (1) Measure resistance between terminals No. 4 and 7 at fuel temperature sensor connector. | |
| (1) | Measure resistance between terminals No. 4 and 7 at fuel temperature sensor connector. |
FUEL TEMPERATURE SENSOR RESISTANCE (DIESEL)
| Terminals No. | Ohms |
|---|---|
| 1 & 2 | 0.0-19.9 |
HEATED OXYGEN SENSOR (HO2S) HEATER RESISTANCE
| Temperature °F (°C) | Ohms |
|---|---|
| 86 (30) | 1500-2000 |
| 104 (40) | 1000-1500 |
| 122 (50) | 800-1000 |
| 140 (60) | 500-700 |
| 158 (70) | 375-500 |
| 176 (80) | 275-375 |
| 194 (90) | 225-275 |
INTAKE AIR TEMPERATURE (IAT) SENSOR RESISTANCE
| Terminals No. | Ohms | |
|---|---|---|
| Passat | ||
| 1 & 2 | 3-200 | |
THROTTLE VALVE CONTROL MODULE (TCVM) RESISTANCE