STARTER SPECIFICATIONS
| Application | In. (mm) | |||
|---|---|---|---|---|
| Brush Length | ||||
| 1.2 & 1.4 Kw | ||||
| Standard | .610 (15.5) | |||
| Minimum | .394 (10) | |||
| 1.8 & 2 Kw | ||||
| Standard | .591 (15) | |||
| Minimum | .354 (9) | |||
| Commutator | ||||
| Diameter | ||||
| 1.2 & 1.4 Kw | ||||
| Minimum | 1.142 (29) | |||
| Standard | 1.181 (30) | |||
| .8 & 2 Kw | ||||
| Minimum | 1.339 (34) | |||
| Standard | 1.378 (35) | |||
| Runout | .0020 (.05) | |||
| Undercut Depth | ||||
| Standard | ||||
| 1.2 & 1.4 Kw | .024 (.6) | |||
| 1.8 & 2 Kw | .028 (.7) | |||
| Minimum | .008 (.2) | |||
| Contact Plate Depth Of Wear | 0.35 (.9) | |||
| Magnetic Switch Contact Plate Discard Thickness | .035 (.9) | |||
| Shunt Coil Resistance | 1.5-1.9 ohms at 68° F (20° C) | |||
| Spring Load | ||||
| 1.2 Kw | ||||
| Installed Minimum | 2.2 Lb (1 Kg) | |||
| Installed Standard | 3.1-4.4 Lb (1.4-2 Kg) | |||
| 1.4 Kw | ||||
| Installed Minimum | 2.7 Lb. (1.2 Kg.) | |||
| Installed Standard | 4-5.3 Lb. (1.8-2.4 Kg.) | |||
| 1.8 & 2 Kw | ||||
| Installed Minimum | 2.9 Lb. (1.3 Kg.) | |||
| Installed Standard | 4.8-6.2 Lb. (2.2-2.8 Kg.) | |||
STARTER SPECIFICATIONS
TORQUE SPECIFICATIONS
| Application | Ft. Lbs. (N.m) | |
|---|---|---|
| Starter Mounting Bolts | 29 (39) | |
| Terminal Mounting Nuts | 13 (17) | |
| INCH Lbs. (N.m) | ||
| End Cover Screws | ||
| 1.2 & 1.4 Kw | 13 (1.5) | |
| 1.8 & 2 Kw | 34 (3.8) | |
| Magnetic Switch Bolts | ||
| 1.2 (V8) | 52 (5.9) | |
| 1.2 & 1.4 Kw (V6) | 22 (2.5) | |
| 1.8 Kw | 30 (3.6) | |
| 2 Kw | 82 (9.3) | |
| Starter Cable Nut | 78 (8.8) | |
| Starter Housing Bolts | ||
| 1.2 & 1.4 Kw | 52 (5.9) | |
| 1.8 & 2 Kw | 82 (9.3) | |
| Starter Wire Nut | 84 (9.8) | |
| Terminal "C" Nut | 52 (5.9) | |
| Through Bolts | ||
| 1.2 & 1.4 Kw | 52 (5.9) | |
| 1.8 & 2 Kw | 82 (9.3) | |
| Wire Protector Bolt | 84 (9.8) | |
TORQUE SPECIFICATIONS