| CAUTION | If ECM replacement is instructed in following testing, always ensure ECM connectors and ground circuit are okay. If either are suspect, repair and repeat testing to confirm ECM malfunction. |
Note. Oxygen sensor No. 1 refers to sensor located in exhaust manifold. Oxygen sensor No. 2 refers to sensor located behind catalytic converter.
Circuit Description
The heated oxygen sensor monitors exhaust gas oxygen content and delivers an input signal to ECM. The ECM uses input signal to determine fuel injection system operation. DTC is set when sensor does not output a rich condition once engine is at normal operating temperature, engine speed of 1500 RPM or more, and vehicle speed is 25-62 MPH for at least 2 minutes. Possible causes are
- Open or short in heated oxygen sensor circuit.
- Heated oxygen sensor.