SERVICE DATA
| Starter | Rated voltage & output power | 12 V 2.0 kW |
|---|---|---|
| Starter | No-load characteristics - Current | 100 A or less at 11.5 V |
| Starter | No-load characteristics - rpm | 2,500 rpm or less |
| Starter | Brush length - STD | 15.0 mm (0.591 in.) |
| Starter | Brush length - Minimum | 9.0 mm (0.354 in.) |
| Starter | Spring installed load - STD | 21.5 - 27.5 N (2.2 - 2.8 kgf, 4.8 - 6.2 lbf) |
| Starter | Spring installed load - Minimum | 12.7 N (1.3 kgf, 2.9 lbf) |
| Starter | Commutator Diameter - STD | 35.0 mm (1.378 in.) |
| Starter | Commutator Diameter - Minimum | 34.0 mm (1.339 in.) |
| Starter | Commutator Undercut depth - STD | 0.7 mm (0.028 in.) |
| Starter | Commutator Undercut depth: Minimum | 0.2 mm (0.008 in.) |
| Starter | Commutator Circle runout Maximum | 0.05 mm (0.0020 in.) |
| Starter | Field frame Shunt coil resistance - at 20°C (68°F) | 1.5 - 1.9 ohm |
| Starter | Magnetic switch Contact plate for wear - Maximum | 0.9 mm (0.035 in.) |
STARTING SERVICE DATA
TORQUE SPECIFICATION
| Part tightened | N.m | Kgf.cm | Ft.lbf |
|---|---|---|---|
| Terminal 30 nut, Terminal C nut x Terminal bolt | 17 | 170 | 13 |
| End cover x Magnetic switch housing | 3.6 | 37 | 32 in.lbf |
| End cover x Brush holder | 3.8 | 39 | 34 in.lbf |
| Starter hosing x Magnetic switch | 9.3 | 95 | 82 in.lbf |
| End cover with field frame x Magnetic switch | 9.3 | 95 | 82 in.lbf |
| Lead wire of field coil x Terminal C | 5.9 | 60 | 52 in.lbf |
| Wire clamp, Starter wire x Starter | 9.81 | 100 | 87 in.lbf |
| Starter x Cylinder block | 39 | 400 | 29 |
STARTING TORQUE SPECIFICATION