Home/Toyota/Corolla/Toyota Corolla IX (2000-2004)/Repair manual/Testing & Diagnostics/DTC P0125: INSUFFICIENT COOLANT TEMPERATURE FOR CLOSED LOOP…
Contents Wiring diagrams Section: Testing & Diagnostics All sections

DTC P0125: INSUFFICIENT COOLANT TEMPERATURE FOR CLOSED LOOP FUEL CONTROL Toyota Corolla IX

CAUTIONIf ECM replacement is instructed in following testing, always ensure ECM connectors and ground circuits are okay. If either are suspect, repair and repeat testing to confirm ECM malfunction.

Note. Heated oxygen sensor No. 1 refers to oxygen sensor closest to engine block. Heated oxygen sensor No. 2 refers to oxygen sensor farthest from engine block.

Note. For component location, see appropriate illustration in THEORY & OPERATION article.

Note. This DTC may be caused by the vehicle running out of fuel.

Circuit Description

Heated oxygen sensor monitors exhaust gas oxygen content and delivers an input signal to ECM. ECM uses input signal to determine fuel injection system operation. Heated oxygen sensor includes a heater. DTC is set when heated oxygen sensor No. 1 does not output a rich condition once engine is at normal operating temperature, engine speed is more than 1400 RPM and vehicle speed is 25-62 MPH for at least 2 minutes. Possible causes are

  1. Fuel system malfunction.
  2. Defective fuel injector.
  3. Ignition system malfunction.
  4. Exhaust system leak.
  5. Heated oxygen sensor No. 1 circuit is open or shorted.
  6. Defective heated oxygen sensor No. 1.
  7. Vehicle run out of fuel.
  8. Defective ECM.

Diagnostic Aids

After confirming DTC P0125, use scan tool to access CURRENT DATA to confirm voltage output of heated oxygen sensor No. 1. If voltage displayed on scan tool is always less than .1 volt, heated oxygen sensor No. 1 circuit may be open or shorted. Using scan tool, read FREEZE FRAME data. Freeze frame data records engine conditions when malfunction is detected.