Home/Toyota/Camry/Toyota Camry XV50 (2011-2014)/Repair manual/Engine Control Systems/Engine Control System (Service Specifications) (2GR-FE): Ot…
Contents Wiring diagrams Section: Engine Control Systems All sections

Engine Control System (Service Specifications) (2GR-FE): Other Toyota Camry XV50

SERVICE DATA

Spark plug
Spark plug typeDENSO madeFK20HR11
Standard electrode gapFor new spark plug1.0 to 1.1 mm (0.0394 to 0.0433 in.)
Maximum electrode gapFor used spark plug1.4 mm (0.0551 in.)
Camshaft timing oil control valve assembly
ResistanceAt 20°C (68°F)6.9 to 7.9 ohms
Throttle body
Resistance2 (M+) - 1 (M-)0.3 to 100 ohms at 20°C (68°F)
Vacuum switching valve (for Engine Mounting)
ResistanceAt 20°C (68°F)19 to 21 ohms
Acceleration pedal sensor
Standard voltage (Accelerator Position No.1)Released0.5 to 1.1 V
Depressed2.6 to 4.5 V
Standard voltage (Accelerator Position No.2)Released1.2 to 2.0 V
Depressed3.4 to 4.8 V
Mass air flow meter
Resistance1 (THA) - 2 (E2)13.6 to 18.4 kohms at -20°C (-4°F)
1 (THA) - 2 (E2)2.21 to 2.69 kohms at 20°C (68°F)
1 (THA) - 2 (E2)0.49 to 0.67 kohms at 60°C (140°F)
Crankshaft position sensor
ResistanceCold1630 to 2740 ohms
Hot2065 to 3225 ohms
Engine coolant temperature sensor
Resistance20°C (68°F)2.32 to 2.59 kohms
80°C (176°F)0.310 to 0.326 kohms
Knock sensor
ResistanceAt 20°C (68°F)120 to 280 kohms
Air fuel ratio sensor
Resistance1 (HA1A) - 2 (+B)1.6 to 3.2 ohms at 20°C (68°F)
1 (HA1A) - 4 (A1A-)10 kohms or higher
Oxygen sensor
Resistance (for Bank 1 Sensor 2)2 (HT1B) - 1 (+B)11 to 16 ohms at 20°C (68°F)
2 (HT1B) - 3 (E2)10 kohms or higher
Resistance (for Bank 2 Sensor 2)1 (HT2B) - 2 (+B)11 to 16 ohms at 20°C (68°F)
1 (HT2B) - 4 (E2)10 kohms or higher
EFI MAIN relay
Specified ConditionNo. 1 integration relay B-1 - No. 1 integration relay A-8Battery voltage is not applied between terminals C-7 and E-2 10 kohms or higher
No. 1 integration relay B-1 - No. 1 integration relay A-8Battery voltage is applied between terminals C-7 and E-2 Below 1 ohms
No. 1 integration relay B-1 - No. 1 integration relay C-3
No. 1 integration relay B-1 - No. 1 integration relay C-4
No. 1 integration relay B-1 - No. 1 integration relay C-6
No. 1 integration relay B-1 - No. 1 integration relay C-9
No. 1 integration relay B-1 - No. 1 integration relay C-10
A/F HTR relay
Specified ConditionNo. 1 integration relay A-6 - No. 1 integration relay D-1Battery voltage is not applied between terminals A-8 and E-2 10 kohms or higher
No. 1 integration relay A-6 - No. 1 integration relay D-1Battery voltage is applied between terminals A-8 and E-2 Below 1 ohms
No. 1 integration relay A-7 - No. 1 integration relay D-1
IG2 relay
Specified ConditionNo. 1 integration relay A-1 - No. 1 integration relay D-3Battery voltage is not applied between terminals C-8 and E-2 10 kohms or higher
No. 1 integration relay A-1 - No. 1 integration relay D-3Battery voltage is applied between terminals C-8 and E-2 Below 1 ohms
No. 1 integration relay A-3 - No. 1 integration relay D-3
No. 1 integration relay A-5 - No. 1 integration relay D-3
No. 1 integration relay C-1 - No. 1 integration relay D-3
No. 1 integration relay C-2 - No. 1 integration relay D-3
No. 1 integration relay C-5 - No. 1 integration relay D-3