Cooling System Specifications
| Application | Description | Unit | Standard |
|---|---|---|---|
| Cooling System | Cooling Capacity | Forced Water Cooling | |
| Coolant | Cooling Capacity | L/qt | 8.0/8.5 |
| Coolant Type | Dex-COOL Coolant or Silicate based Coolant | ||
| Thermostat | Thermostat Type | Wax Expansion Pellet Type | |
| Temperature (opened initially) | °C (°F) | 82 ± 2 (179.6 ± 35.6) | |
| Temperature (perfectly opened) | °C (°F) | 97 (206.6) | |
| Temperature (perfectly closed) | °C (°F) | 79 ± 2 (174.2 ± 35.6) | |
| Stroke (perfectly opened) | Mm (in.) | 8 (0.315) | |
| Surge Tank | Open Pressure of the Pressure Valve | KPa (psi) | 117.7 - 147.1 (17.07 - 21.34) |
| Open Pressure of the Vacuum Valve | KPa (psi) | 9.8 (1.42) | |
| Water Pump | Water Pump Type | Centrifugal | |
| Quantity Per Minute | L/min (qt/min) | 220 (232.5) @ 6,000 rpm | |
| Impeller Blade Number | EA | 6 |
COOLING SYSTEM SPECIFICATIONS
Tightening Torque Specifications
| Application | N.m | Lb-in. |
|---|---|---|
| Water Pump Mounting Bolts | 10 | 89 |
| Fan Assembly Mounting Bolts | 4 | 35 |
| Fan Motor Retaining Screws | 4 | 35 |
| Radiator Retaining Bolts, Upper Left and Upper Right | 14 | |
| Surge Tank Attaching Bolt | 8 | 71 |
| Thermostat Housing Mounting Bolts | 20 |
TIGHTENING TORQUE SPECIFICATIONS