Typical malfunction thresholds
| P0712 |
|---|
| Input signal < 0.05 V |
| P0713 |
| Input signal > 4.9 V |
TRANSMISSION FLUID TEMPERATURE SENSOR TYPICAL MALFUNCTION THRESHOLDS
| DTC | P0962/P0963 |
|---|---|
| Monitor execution | Continuous |
| Monitoring duration | 0.5 seconds |
PRESSURE CONTROL SOLENOID A OPERATION CHART
| Parameter | Minimum | Maximum |
|---|---|---|
| Battery voltage | 10.5 V |
PRESSURE CONTROL SOLENOID A ENABLE CONDITIONS
| P0962 |
|---|
| Monitor voltage < or = 0.02 V |
| P0963 |
| Monitor voltage > or = 0.26 V |
PRESSURE CONTROL SOLENOID A TYPICAL MALFUNCTION THRESHOLDS
| DTC | P0973/P0974 |
|---|---|
| Monitor execution | Continuous |
| Monitoring duration | 0.5 seconds |
SHIFT SOLENOID A OPERATION CHART
| Parameter | Minimum | Maximum |
|---|---|---|
| Battery voltage | 10.5 V | |
| Shift solenoid valve "A" (P0973) | ON | |
| Shift solenoid valve "A" (P0974) | OFF | |
SHIFT SOLENOID A ENABLE CONDITIONS
| P0973 |
|---|
| Monitor signal (monitor solenoid condition) < 0.01 V |
| P0974 |
| Monitor signal (monitor solenoid condition) > 12 V |
SHIFT SOLENOID A TYPICAL MALFUNCTION THRESHOLDS
| DTC | P0976/P0977 |
|---|---|
| Monitor execution | Continuous |
| Monitoring duration | 0.5 seconds |
SHIFT SOLENOID B OPERATION CHART
| Parameter | Minimum | Maximum |
|---|---|---|
| Battery voltage | 10.5 V | |
| Shift solenoid valve "B" (P0976) | ON | |
| Shift solenoid valve "B" (P0977) | OFF | |
SHIFT SOLENOID B ENABLE CONDITIONS
| P0976 |
|---|
| Monitor signal (monitor solenoid condition) < 0.01 V |
| P0977 |
| Monitor signal (monitor solenoid condition) > 12 V |
SHIFT SOLENOID B TYPICAL MALFUNCTION THRESHOLDS
| DTC | P1723 |
|---|---|
| Monitor execution | Continuous |
| Monitor duration | 10 seconds |
3 POSITION SWITCH OPERATION CHART
| Parameter | Minimum | Maximum |
|---|---|---|
| Battery voltage | 10.5 V |
3 POSITION SWITCH ENABLE CONDITIONS
| P1723 |
|---|
| Monitor voltage > or = 4.2 V or < 0.9 V |
3 POSITION SWITCH TYPICAL MALFUNCTION THRESHOLDS
| DTC | P2763/P2764 |
|---|---|
| Monitor execution | Continuous |
| Monitor duration | 0.5 seconds (P2763)/0.5 seconds (P2764) |
TCC SOLENOID VALVE OPERATION CHART
| Parameter | Minimum | Maximum |
|---|---|---|
| Battery voltage | 10.5 V |
TCC SOLENOID VALVE ENABLE CONDITIONS
| P2763 |
|---|
| Monitor voltage > or = 0.26 V |
| P2764 |
| Monitor voltage < or = 0.02 V |
TCC SOLENOID VALVE TYPICAL MALFUNCTION THRESHOLDS
Input signal of transmission range sensor (P0707), transmission range sensor (P0705), transmission fluid temperature sensor (P0711), input shaft speed sensor (P0717), output shaft speed sensor (P0722), TCC lock-up solenoid valve (P0741, P0742), shift solenoid valve (P0751, P0752, P0756, P0757), TCM (P1702), 4L/N switch (P1874, P1875) CAN communication (U0073, U0100) are checked for circuit rationality by monitoring each sensor and vehicle condition.