Contents Wiring diagrams Section: Cooling System (Mechanical) All sections

Engine Cooling System: Specifications Suzuki Forenza I

Capacity

ApplicationDescriptionUnitStandard
Cooling SystemCooling TypeForced Water Cooling
CoolantCoolant CapacityL/qt7.5/7.93
ThermostatThermostat TypeWax Expansion Pellet Type
Temperature (opened initially)°C (°F)87 (188.6)
Temperature (perfectly opened)°C (°F)102 (216)
Temperature (perfectly closed)°C (°F)82 (179.6)
Stroke (perfectly opened)Mm (in.)7 (0.280)
Surge TankOpen Pressure of The Pressure ValveKPa (psi)117.7 - 147.1 (17.07 - 21.34)
Open Pressure of The Vacuum ValveKPa (psi)9.8 (1.42)
Coolant PumpWater Pump TypeCentrifugal
Impeller DiameterMm (in.)55 (2.17)
Impeller Blade NumberEA6

SPECIFICATIONS

Tightening Torque Specifications

ApplicationN.m
Water Pump Mounting Bolts25
Fan Assembly Mounting Bolts4
Fan Motor Nut3.2
Fan Motor Retaining Screws4
Radiator Retaining Bolts8
Surge Tank Attaching Bolt5
Thermostat Housing Mounting Bolts15

TIGHTENING TORQUE SPECIFICATIONS