Home/Subaru/SVX/Subaru SVX I (1991-1997)/Repair manual/Cooling System (Mechanical)/Cooling System Specifications & Component Removal & Install…
Contents Wiring diagrams Section: Cooling System (Mechanical) All sections

Cooling System Specifications & Component Removal & Installation: Specifications Subaru SVX I

Cooling System (Mechanical) 2 illustrations

TORQUE SPECIFICATIONS

ApplicationFt. Lbs. (N.m / kg.m)
Water Pump Mounting Bolts
Step 17-10 (10-14 / 1-1.4)
Step 27-10 (10-14 / 1-1.4)

TORQUE SPECIFICATIONS

Scheme 1

Scheme 1: COOLING SYSTEM SPECIFICATIONS
ApplicationSpecification
Coolant Replacement Interval30,000 Miles Or 30 Months
Coolant Capacity (Includes Heater & Reserve Tank)7.9 Qts. (7.5L)
Pressure Cap11.6-14.4 psi
Thermostat Opening Temperature
Thermostat Starts To Open169-176°F (84-87°C)
Thermostat Fully Open196°F (91°C)

COOLING SYSTEM SPECIFICATIONS

Electric Cooling Fan System Wiring Diagram. Scheme 2

Scheme 2: Electric Cooling Fan System Wiring Diagram