GENERAL TOOL
| TOOL NAME | REMARKS |
|---|---|
| Chain sling | Used for holding and balancing the engine unit when removing and installing the MT gear select cable. Length: 0.8 - 1 m (2.6 - 3.3 ft) Load capacity: 1.2 t (2646 lb) or more Diameter: 6 mm (0.24 in) or 6.3 mm (0.25 in) Chain external width: 23.5 mm (0.93 in) or less Chain internal width: 8.5 mm (0.33 in) or more |
| Screw shackle | Used for holding and balancing the engine unit when removing and installing the MT gear select cable. Load capacity: 250 kg (551 lb) or more Use two pieces. |
| Circuit tester | Used for measuring resistance and voltage. |
Scheme 728
Scheme 729
Scheme 730
Scheme 731
Scheme 732
| Item | Connector No. | Terminal No. | Input/Output signal |
|---|---|---|---|
| Measured value and measuring conditions | |||
| Battery power supply | B281 | 6 | 9 - 16 V |
| I84 | 6 | ||
| Ignition power supply | I171 | 17 | 9 - 16 V when ignition switch is at ON or START. |
| 25 | 9 - 16 V when ignition switch is at ACC. | ||
| TCM ("P" range) | B281 | 20 | Pulse signal (CAN communication) |
| 28 | |||
| Stop light switch | B280 | 10 | 9 - 16 V when stop light switch is ON. Less than 1.5 V when stop light switch is OFF. |
| "P" range switch | B281 | 21 | Less than 1.5 V when select lever is in "P" range. 9 - 16 V when select lever is in other positions than "P" range. |
| Solenoid unit output | B281 | 5 | 8.5 - 16 V when shift lock is released. Less than 1.5 V when shift lock is operating. |
| Key warning switch signal (Model without push button ignition switch) | B280 | 4 | 9 - 16 V when key is inserted. Less than 1.5 V when key is removed. |
| Key lock solenoid output (Model without push button ignition switch) | B281 | 3 | 7 - 14 V (unlock) (1) |
| 4 | 7 - 14 V (lock) (1) | ||
| Ground | B280 | 1 | 1 V or less |
| B281 | 31 | ||
| I84 | 1 | ||
| I171 | 29 | ||
| (1) Measuring condition | |||
| (1) | Measuring condition |
| Key warning switch | "P" range switch | Ignition switch | Output |
|---|---|---|---|
| OFF | Unlock (Key can be removed) | ||
| ON | OFF | Lock (Key cannot be removed) | |
| ON | ON | OFF | Unlock |
| ON | ON | ON | Lock |
Scheme 733
Scheme 734
- Output Signal for Unlock
- Output Signal for Lock