CHECK BATTERY CURRENT SENSOR UNIT
| CAUTION | Pay attention to polarity when measuring the resistance in the battery current sensor. |
Check the resistance between the battery current sensor terminals.
Scheme 90
| Terminal No. | Standard |
|---|---|
| 2 (+) and 3 (-) | 0 - 0.5 kohms |
| 2 (+) and 4 (-) | 3 - 10 kohms |
| 3 (+) and 4 (-) | 3 - 10 kohms |