| C�02, Hardware and software control unit | |||
|---|---|---|---|
| Test | Instructions | Nominal value | |
| T01 | Fault recognition | ||
| Control unit defective | Fault code 55 | ||
| - | RAM/ROM fault | ||
| - | Fault in �release� relay | ||
| - | Fault in �lock� relay | ||
| - | Fault in �anti�theft protection� relay | ||
| - | Fault in HF�receiver | ||
| Yes: E01 | No: T02 | ||
| T02 | Fault recognition | ||
| EEPROM defective (malfunction) | Fault code 51 | ||
| Yes: E01 | No: T03 | ||
| T03 | Fault recognition | ||
| EEPROM not programmed | Fault code 52 | ||
| Yes: E02 | No: T04 | ||
| T04 | Fault recognition | ||
| Security code not programmed | Fault code 13 | ||
| Yes: E03 |
| C�02, Hardware and software control unit | |
|---|---|
| No. | Result |
| E01 | Anti�theft warning system control unit & central door locking K94 defective |
| E02 | Reprogramme anti�theft warning system control unit & central door locking K94 |
| E03 | Programme security code, anti�theft warning system control unit & central door locking K94 |
| Note: | |
| The number of security code entries is counted down from 10 after a false entry. After correct entry of the security code, the number of entries returns to 10. Waiting times after faulty entries: After the 1st and 2nd faulty entry 10 s After the 3rd faulty entry 10 min, The time is then doubled up to the 10th faulty entry at 1280 min |