Performance Data
| Ambient temperature | High pressure | Low pressure | Inside temperature (air flow from vent nozzles) | Engine speed | ||
|---|---|---|---|---|---|---|
| °C | kPa | bar | kPa | bar | °C | rpm |
| 15 | 1400 - 2000* | 14 - 20* | 140 - 170 | 1,4 - 1,7 | 4 - 8 | |
| 20 | 1400 - 2000* | 14 - 20* | 155 - 185 | 1,55 - 1,85 | 5 - 10 | |
| 1500 | ||||||
| 25 | 1450 - 1650 | 14,5 - 16,5 | 175 - 215 | 1,75 - 2,15 | 8 - 13 | |
| 30 | 1650 - 1850 | 16,5 - 18,5 | 185 - 225 | 1,85 - 2,25 | 9 - 14 |
35
| 2000 - 2200 | 20 - 22 | 245 - 285 | 2,45 - 2,85 | 14 - 19 |
* Increased distribution range by switching radiator fan motors M 4 and M 11 between 1 st and 2nd speeds.