Remove
- 1. Disconnect harness connector (3) from mass air flow meter (5)
- 2. Release cover (2) from air cleaner assembly • Release 4x screw
- 3. Remove air cleaner element from air cleaner assembly
- 4. Release outlet hose (1) to coolant expansion tank from air cleaner assembly • Release clip
- 5. Release harness for mass air flow meter from air cleaner assembly • Release clip
- 6. Remove air cleaner assembly from battery tray and upper front panel • Remove 2x bolt (4) • Pull up to release 2x locator from battery tray
- 7. Disconnect harness connector (1) from reverse lamp switch (2)
- 8. Remove reverse lamp switch with sealing washer from transmission • Remove O ring from reverse lamp switch
Install
- 9. Install new O ring to new reverse lamp switch (2) • Apply suitable lubricant to O ring, then slide on
- 10. Install reverse lamp switch with sealing washer to transmission • Secure reverse lamp switch to 23 Nm
- 11. Connect harness connector (1) to reverse lamp switch
- 12. Install air cleaner assembly to battery tray and upper front panel • Push down to secure 2x locator to battery tray • Install 2x bolt (4)
- 13. Secure harness for mass air flow meter to air cleaner assembly • Secure clip
- 14. Secure outlet hose (1) to coolant expansion tank to air cleaner assembly • Secure clip
- 15. Install air cleaner element to air cleaner assembly
Note. Before installing the air cleaner element, remove all debris from the air cleaner assembly.
- 16. Secure cover (2) to air cleaner assembly • Secure 4x screw
- 17. Connect harness connector (3) to mass air flow meter (5)