KEYLESS POWER WINDOW DOWN FUNCTION
All power windows open when the unlock button on Intelligent Key is activated and kept pressed for more than 3 seconds NOTE with the ignition switch OFF. The windows keep opening if the unlock button is continuously pressed.
The power window opening stops when the following operations are performed.
- When the unlock button is kept pressed more than 15 seconds.
- When the ignition switch is turned ON while the power window opening is operated.
- When the unlock button is released.
While retained power operation is active, keyless power window down function cannot be operated. Keyless power window down operation mode can be changed by "PW DOWN SET" mode in "WORK SUPPORT". Refer to " INTELLIGENT KEY : CONSULT-III FUNCTION (BCM - INTELLIGENT KEY) ".
Note. Use CONSULT-III to change settings. MODE 1 (3 sec) / MODE 2 (OFF) / MODE 3 (5 sec)
Scheme 208
APPLICATION ITEM
CONSULT-III performs the following functions via CAN communication with BCM.
| Direct Diagnostic Mode | Description |
|---|---|
| ECU Identification | The BCM part number is displayed. |
| Self Diagnostic Result | Displays the diagnosis results judged by BCM. |
| Data Monitor | The BCM input/output signals are displayed. |
| Active Test | The signals used to activate each device are forcibly supplied from BCM. |
| Work support | Changes the setting for each system function. |
| Configuration | Enables to read and save the vehicle specification. Enables to write the vehicle specification when replacing BCM. |
| CAN Diag Support Mntr | Monitors the reception status of CAN communication viewed from BCM. |
CONSULT-III FUNCTION DESCRIPTION CHART
SYSTEM APPLICATION
BCM can perform the following functions.
Scheme 209
DATA MONITOR
| Monitor Item [Unit] | Description |
|---|---|
| DOOR SW-DR [On/Off] | Indicates condition of front door switch LH |
| DOOR SW-AS [On/Off] | Indicates condition of front door switch RH |
DATA MONITOR CHART
- REQUIRED WORK WHEN REPLACING BCM Initialize control unit. Refer to " «CONFIGURATION (BCM) : SPECIAL REPAIR REQUIREMENT»(ref-388072-S30068493832011022800000) ". Work End.
- PERFORM INITIALIZATION PROCEDURE Perform initialization procedure. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". GO TO 2
- CHECK ANTI-PINCH OPERATION Check anti-pinch operation. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". End.
- PERFORM INITIALIZATION PROCEDURE Perform initialization procedure. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". GO TO 2
- CHECK ANTI-PINCH OPERATION Check anti-pinch operation. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". End.
- PERFORM INITIALIZATION PROCEDURE Perform initialization procedure. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". GO TO 2
- CHECK ANTI-PINCH OPERATION Check anti-pinch operation. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". End.
- CHECK POWER WINDOW MOTOR Check that front power window motor LH operates with main power window and door lock/unlock switch. Is the inspection result normal? YES >> Front power window motor LH is OK. NO >> Refer to " «DRIVER SIDE : DIAGNOSIS PROCEDURE»(ref-388086-S33403898392011022800000) ".
- PERFORM INITIALIZATION PROCEDURE Perform initialization procedure. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". GO TO 2
- CHECK ANTI-PINCH OPERATION Check anti-pinch operation. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". End.
- CHECK POWER WINDOW MOTOR CIRCUIT Check that front power window motor RH operates with main power window and door lock/unlock switch or power window and door lock/unlock switch RH. Is the inspection result normal? YES >> Front power window motor RH is OK. NO >> Refer to " «PASSENGER SIDE : DIAGNOSIS PROCEDURE»(ref-388086-S11438862242011022800000) ".
- PERFORM INITIALIZATION PROCEDURE Perform initialization procedure. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". GO TO 2
- CHECK ANTI-PINCH OPERATION Check anti-pinch operation. Refer to " «ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : SPECIAL REPAIR REQUIREMENT»(ref-388086-S21739610572011022800000) " and " «ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : SPECIAL REPAIR REQUIREMENT»(ref-388086-S17366526132011022800000) ". End.
- CHECK POWER WINDOW MOTOR CIRCUIT Check that rear power window motor LH operates with main power window and door lock/unlock switch or rear power window switch LH. Is the inspection result normal? YES >> Rear power window motor LH is OK. NO >> Refer to " «REAR LH : DIAGNOSIS PROCEDURE»(ref-388086-S27841854252011022800000) ".