MAINTENANCE OF LUBRICANT LEVEL

The compressor lubricant is circulating in the system together with the refrigerant. It is necessary to fill compressor with lubricant when replacing A/C system parts or when a large amount of refrigerant leakage is detected. It is important to always maintain lubricant level within the specified level. Otherwise, the following conditions may occur.

  1. Insufficient lubricant amount: Stuck compressor
  2. Excessive lubricant amount: Insufficient cooling (caused by insufficient heat exchange) Name: A/C system Oil Type R