Contents Section: Automatic HVAC System All sections

Automatic Air Conditioner: Adjustments Nissan Altima L31 рестайлинг

Automatic HVAC System 1 illustration ~203 words

Lubricant Adjustment Procedure for Compressor Replacement

  1. Before connecting recovery/recycling equipment to vehicle, check recovery/recycling equipment gauges. No refrigerant pressure should be displayed. If NG, recover refrigerant from equipment lines.
  2. Connect recovery/recycling equipment to vehicle. Confirm refrigerant purity in supply tank using recovery/recycling equipment and refrigerant identifier. If NG, refer to " «CONTAMINATED REFRIGERANT»(ref-232736-S11300872202006052000000) ".
  3. Confirm refrigerant purity in vehicle A/C system using recovery/recycling equipment and refrigerant identifier. If NG, refer to " «CONTAMINATED REFRIGERANT»(ref-232736-S11300872202006052000000) ".
  4. Discharge refrigerant into the refrigerant recovery/recycling equipment. Measure lubricant discharged into the recovery/recycling equipment.
  5. Drain the lubricant from the "old" (removed) compressor into a graduated container and recover the amount of lubricant drained.
  6. Drain the lubricant from the "new" compressor into a separate, clean container.
  7. Measure an amount of new lubricant installed equal to amount drained from "old" compressor. Add this lubricant to "new" compressor through the suction port opening.
  8. Measure an amount of new lubricant equal to the amount recovered during discharging. Add this lubricant to "new" compressor through the suction port opening.
  9. If the liquid tank also needs to be replaced, add an additional 5 m l (0.2 US fl oz, 0.2 lmp fl oz) of lubricant at this time.
CAUTIONDo not add the 5 m l (0.2 US fl oz, 0.2 lmp fl oz) of lubricant if only replacing the compressor and not the liquid tank.

Scheme 27

Scheme 27