Contents Section: Cooling - Lancer All sections

DIAGNOSIS Mitsubishi Lancer Evolution IX

Cooling - Lancer 21 illustrations ~967 words

DIAGNOSIS

Required Special Tools

  1. MB991223: Harness Set
  2. MB992006: Extra Fine Probe

Scheme 11

Scheme 11

Scheme 12

Scheme 12

Scheme 13

Scheme 13

Scheme 14

Scheme 14

Scheme 15

Scheme 15

Scheme 16

Scheme 16

Scheme 17

Scheme 17

Scheme 18

Scheme 18

Scheme 19

Scheme 19

Scheme 20

Scheme 20

Scheme 21

Scheme 21

Scheme 22

Scheme 22

Scheme 23

Scheme 23

Scheme 24

Scheme 24

Scheme 25

Scheme 25

Scheme 26

Scheme 26

Scheme 27

Scheme 27

Scheme 28

Scheme 28

Scheme 29

Scheme 29

Scheme 30

Scheme 30

Scheme 31

Scheme 31
  1. STEP 1. Check the circuit at fan control module connector A-17 (terminal 3). Disconnect fan control module connector A-17, and measure at the harness side connector. Measure the voltage between terminal number 3 and ground. When the ignition switch is turned to the "ON" position, voltage should measure battery positive voltage. Q: Is there voltage battery positive voltage when the ignition switch is turned to the "ON" position? YES : Go to Step 8 . NO : Go to Step 2.
  2. STEP 2. Check the fan control relay. Refer to «FAN CONTROL RELAY CONTINUITY CHECK»(/mitsubishi/lancer-evolution/ix-2005-2007/remont/cooling-system-mechanical/#cooling-lancer__fan-control-relay-continuity-check) . Q: Is the fan control relay in good condition? YES : Go to Step 3. NO : Replace it, then go to Step 1.
  3. STEP 3. Check the MFI relay. Refer to «MULTIPORT FUEL INJECTION (MFI) RELAY CONTINUITY CHECK»(/mitsubishi/lancer-evolution/ix-2005-2007/remont/removal-installation/#multiport-fuel-injection-mfi-lancer-20l) . Q: Is the MFI relay in good condition? YES : Go to Step 4. NO : Replace it, then go to Step 1 .
  4. STEP 4. Check for harness damage between fusible link number 2 and fan control relay connector A-09X (terminal 4). Q: Are the harness wires between fusible link number 2 and fan control relay connector A-09X damaged? YES : Repair or replace them, then go to Step 13 . NO : Go to Step 5.
  5. STEP 5. Check for harness damage between fan control relay connector A-09X (terminal 2) and fan control module connector A-17 (terminal 3). Q: Are the harness wires between fan control relay connector A-09X (terminal 2) and fan control module connector A-17 (terminal 3) damaged? YES : Repair or replace them, then go to Step 13 . NO : Go to Step 6.
  6. STEP 6. Check for harness damage between MFI relay connector B-16X and fan control relay connector A-09X. NOTE: After inspecting intermediate connector A-13 terminal 8 and joint connector C-105 terminal 28, 33 inspect the wires. If intermediate connector A-13 and joint connector C-105 are damaged, repair or replace them. Refer to «HARNESS CONNECTOR INSPECTION»(/mitsubishi/lancer-evolution/ix-2005-2007/remont/body-electrical/#general-electrical-lancer) . Q: Are the harness wires between MFI relay connector B-16X (terminal 4) and fan control relay connector A-09X (terminal 1) damaged? YES : Repair or replace them, then go to Step 13 . NO : Go to Step 7.
  7. STEP 7. Check for harness damage between fan control relay connector A-09X (terminal 3) and ground. Q: Are the harness wires between fan control relay connector A-09X (terminal 3) and ground damaged? YES : Repair or replace them, then go to Step 13 . NO : Go to Step 8.
  8. STEP 8. Check the circuit at fan control module connector A-17 (terminal 1). Disconnect fan control module connector A-17, and measure at the harness side connector. Measure the resistance between terminal number 1 and ground. Q: Is the resistance less than 2 ohms? YES : Go to Step 10 . NO : Go to Step 9.
  9. STEP 9. Check the harness wire between fan control module connector A-17 and ground. Q: Are the harness wires between fan control module connector A-17 and ground damaged? YES : Repair or replace them, then go to Step 13 . NO : Go to Step 10.
  10. STEP 10. Measure the output circuit voltage at ECM connector C-119 (terminal 18) < 2.0L-M/T >, C-133 (terminal 17) < 2.4L-M/T > or PCM connector C-120 (terminal 18) < 2.0L-A/T >, C-134 (terminal 17) < 2.4L-A/T > by backprobing. Do not disconnect ECM connector C-119 (terminal 18) < 2.0L-M/T >, C-133 (terminal 17) < 2.4L-M/T > or PCM connector C-120 (terminal 18) < 2.0L-A/T >, C-134 (terminal 17)< 2.4L-A/T >. Start the engine and allow it to idle. Measure the voltage between terminal number 18 < 2.0L > or 17 < 2.4L > and ground by backprobing. Q: Is the voltage 0.7 volt or more when the radiator fan is operating? YES : Go to Step 12 . NO : Go to Step 11.
  11. STEP 11. Check the harness wire between ECM connector C-119 (terminal 18) < 2.0L-M/T >, C-133 (terminal 17) < 2.4L-M/T > or PCM connector C-120 (terminal 18) < 2.0L-A/T >, C-134 (terminal 17) < 2.4L-A/T > and fan control module connector A-17. NOTE: If intermediate connector A-13 terminal 1 is damaged, repair or replace it. Refer to «HARNESS CONNECTOR INSPECTION»(/mitsubishi/lancer-evolution/ix-2005-2007/remont/body-electrical/#general-electrical-lancer) . Q: Are the harness wires between ECM connector C-119 (terminal 18) < 2.0L-M/T >, C-133 (terminal 17) < 2.4L-M/T > or PCM connector C-120 (terminal 18) < 2.0L-A/T >, C-134 (terminal 17) < 2.4L-A/T > and fan control module connector A-17 (terminal 2) damaged? YES : Repair or replace them, then go to Step 13 . NO : Go to Step 12.
  12. STEP 12. Check the fan control module at ECM connector C-119 (terminal 18) < 2.0L-M/T >, C-133 (terminal 17) < 2.4L-M/T > or PCM connector C-120 (terminal 18) < 2.0L-A/T >, C-134 (terminal 17) < 2.4L-A/T >. Disconnect ECM connector C-119 (terminal 18) < 2.0L-M/T >, C-133 (terminal 17) < 2.4L-M/T > or PCM connector C-120 (terminal 18) < 2.0L-A/T >, C-134 (terminal 17) < 2.4L-A/T >. Turn the ignition switch to the "ON" position. Q: Do the radiator fan motor and condenser fan motor operate? YES : Replace the ECM < M/T > or PCM < A/T >. Then go to Step 13. NO : Replace the fan control module. Then go to Step 13.
  13. STEP 13. Check the symptoms. Q: Do the radiator fan and condenser fan operate correctly? YES : The procedure is complete. NO : Return to Step 1 .