Contents Wiring diagrams Section: Automatic HVAC System All sections

Automatic Air Conditioning: Overview Mitsubishi Eclipse IV

GENERAL DESCRIPTION

The heater and cooling units are combined in a single unit, which, with the mode film damper and flow rate control valve in the heater unit, reduces ventilation resistance, increases fan power, and decreases noise.

ITEMSPECIFICATION
Heater control assemblyDial type
CompressorMSC105CA
Compressor ModelScroll type
Refrigerant and quantity g (oz)R-134a (HFC-134a), 530 - 570 (18.7 - 20.1)

ITEM SPECIFICATIONS

TECHNICAL DESCRIPTION (COMMENT)

If the rear window defogger does not operate when the rear window defogger switch is turned on, the rear window defogger relay system may be defective.

CIRCUIT OPERATION

Turn ON the rear window defogger switch. If the rear window defogger does not shut off after about 16 minutes then the rear window defogger timer is malfunctioning.