COOLING SYSTEM DRAINING
Note. Less than 80 percent of coolant capacity can be recovered with engine in vehicle. Dirty, rusty or contaminated coolant should be drained and filled with NEW coolant.
Release pressure in cooling system by slowly turning pressure relief cap 1/2 turn counterclockwise or radiator cap counterclockwise to first stop. When pressure is released, remove pressure relief cap/radiator cap. Raise and support vehicle. Remove 7 bolts and 3 nuts retaining front splash shield and remove front splash shield. Place a suitable container below radiator draincock. Open draincock and drain engine coolant. Close radiator draincock.
Inertia Fuel Shutoff Switch Reset Procedure
| WARNING | If you see or smell gasoline at any time other than during fueling, DO NOT reset Inertia Fuel Shutoff (IFS) switch. |
Note. With IFS in CLOSED position, reset button can be depressed an additional 1/16" against the spring.
Turn ignition off. Check for fuel leaks in engine compartment. If no leak is present, reset IFS switch by pushing reset button on top of switch. Turn ignition switch on for a few seconds, then off again. Again, check for leaking fuel.