Contents Wiring diagrams Section: Starter All sections

Starting System: Specifications Mercury Montego III

GENERAL SPECIFICATIONS

ItemSpecification
Normal engine cranking speed200-250 rpm
Starter motor no-load current draw60-80 amps
Starter motor normal load current draw130-190 amps
Starter motor maximum load current draw800 amps
Starting circuit maximum voltage drop (Engine at normal operating temperature)0.5 volts

GENERAL SPECIFICATIONS

TORQUE SPECIFICATIONS

DescriptionNmLb-ftLb-in
Transaxle roll restrictor bolt (1)4835
Transaxle roll restrictor cross brace bolts (1)5541
Starter motor solenoid S terminal (small nut)653
Starter motor solenoid B+ terminal (large nut)129
Starter motor bolts2518
(1) When reinstalling fasteners originally coated with threadlocker, clean with a wire brush prior to applying new threadlocker. Apply threadlocker to the threads of the bolt(s).
(1)When reinstalling fasteners originally coated with threadlocker, clean with a wire brush prior to applying new threadlocker. Apply threadlocker to the threads of the bolt(s).

TORQUE SPECIFICATIONS