Leak Detection
| CAUTION | Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is contaminated with refrigerant gas, the leak detector will indicate this gas all the time. Odors from other chemicals such as antifreeze, diesel fuel, disc brake cleaner or other cleaning solvents can cause the same problem. Using a fan to ventilate the area to be tested before proceeding with the leak detection procedure is helpful in removing small traces of contamination from the air, but the fan should be turned off during actual testing. |
Scheme 221
- Leak test the refrigerant system using the leak detector. Follow the instructions included with the leak detector for handling and operation techniques.
- If a leak is found, recover the refrigerant. For additional information, refer to «AIR CONDITIONING (A/C) SYSTEM RECOVERY, EVACUATION AND CHARGING»(ref-233047-S15013960892006052400000) . Repair the system. Test the system for normal operation.