HVAC Control System - General Information: Specifications Mercury Montego III

GENERAL SPECIFICATIONS CHART

ItemSpecification
A/C Compressor
TypeSC100 variable scroll
Displacement100 cc (6.1 cu in)
RotationClockwise
A/C Pressure Relief Valve (1)
Open pressures3,792-4,137 kPa (550-600 psi)
Close pressure3103 kPa(450 psi)
Magnetic Clutch
Air gap clearance0.35-0.75 mm (0.014-0.030 in)
Evaporator Discharge Air Temperature Sensor
On temperature5°C (41°F)
Off temperature4°C (39°F)
Refrigerant Lubricant and Capacity
PAG Refrigerant Compressor Oil (R-134a Systems) YN-12-DWSH-M1C231-B
Capacity without auxiliary climate control207 ml (7 oz)
Capacity with auxiliary climate control266 ml (9 oz)
Refrigerant and Capacity
R-134a Refrigerant YN-19 (US); CYN-16-P or CYN-16-R (Canada)WSH-M17B19-A
Capacity without auxiliary climate control0.82 kg (29 oz)
Capacity with auxiliary climate control1.08 kg (38 oz)
Refrigerant System Cleaner
A/C System Flushing Solvent YN-23
(1) Manifold gauge set pressures may vary slightly depending on the distance between the service gauge port valve and the A/C pressure relief valve, the A/C cycling switch or the pressure cutoff switch location.