Home/Mercury/Capri/Mercury Capri III (1990-1995)/Repair manual/Sensor Range Charts/Engine Controls - Sensor Operating Range Charts
Contents Section: Sensor Range Charts All sections

Engine Controls - Sensor Operating Range Charts Mercury Capri III

INTRODUCTION

Sensor operating range information can help determine if a sensor is out of calibration. An out-of-calibration sensor may not set a trouble code, but it may cause driveability problems.

Note. Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.

Vacuum: In. Hg.(2) Volts
03.84
53.36
102.66
151.93
201.26
25.58
(1) Measure voltage between breakout box test pins BP and SIGRTN on Capri, or between test pins BP and GND on Festiva. (2) Voltage may vary by plus or minus 15 percent.
(1)Measure voltage between breakout box test pins BP and SIGRTN on Capri, or between test pins BP and GND on Festiva.
(2)Voltage may vary by plus or minus 15 percent.

BAROMETRIC PRESSURE SENSOR OUTPUT VOLTAGE (1)

Temperature °F (°C)Ohms
4 (-20)14,600-17,800
68 (20)2200-2700
104 (40)1000-1300
140 (60)500-650
176 (80)290-350
(1) Measure resistance between breakout box test pins ECT and SIGRTN on Capri, or between test pins ECT and GND on Festiva.
(1)Measure resistance between breakout box test pins ECT and SIGRTN on Capri, or between test pins ECT and GND on Festiva.

ENGINE COOLANT TEMPERATURE SENSOR RESISTANCE (1)

RPMVolts
5001.103
10001.257
15001.542
20001.768
25002.06
30002.15
35002.26
40002.50
45002.47
50002.40
(1) Measure voltage between breakout box test pins IDM and VPWR.
(1)Measure voltage between breakout box test pins IDM and VPWR.

IGNITION DIAGNOSTIC MONITOR VOLTAGE (1)

Throttle Opening(2) (3) Ohms(2) (3) Volts
1/8989.998
1/411041.60
3/812782.37
1/214622.74
5/814803.15
3/414593.43
7/811443.60
Fully Open10724.02
(1) Measure resistance and voltage between breakout box test pins TP and SIGRTN on Capri. (2) Capri only. Festiva uses throttle position switch. (3) Resistance and voltage may vary by plus or minus 15 percent.
(1)Measure resistance and voltage between breakout box test pins TP and SIGRTN on Capri.
(2)Capri only. Festiva uses throttle position switch.
(3)Resistance and voltage may vary by plus or minus 15 percent.

THROTTLE POSITION SENSOR RESISTANCE & VOLTAGE (1)

Door Opening(2) (3) Volts
1/83.24
1/45.60
3/85.62
1/25.83
5/86.02
3/46.57
7/87.46
Fully Open7.87
(1) Measure voltage between breakout box test pins VAF and SIGRTN on Capri, or between test pins VAF and GND on Festiva. (2) Capri only. On Festiva, voltage should vary smoothly from .5-1.5 volts with door fully open, to 4.5-5 volts with door fully closed. (3) Voltage may vary by plus or minus 15 percent.
(1)Measure voltage between breakout box test pins VAF and SIGRTN on Capri, or between test pins VAF and GND on Festiva.
(2)Capri only. On Festiva, voltage should vary smoothly from .5-1.5 volts with door fully open, to 4.5-5 volts with door fully closed.
(3)Voltage may vary by plus or minus 15 percent.

VANE AIRFLOW METER VOLTAGE (1)

Temperature °F (°C)(2) Ohms
4 (-20)15,000
32 (0)5200
68 (20)2500
104 (40)1100
140 (60)600
176 (80)300
(1) Measure resistance between breakout box test pins VAT and SIGRTN on Capri, or between test pins VAT and GND on Festiva. (2) Resistance may vary by plus or minus 15 percent
(1)Measure resistance between breakout box test pins VAT and SIGRTN on Capri, or between test pins VAT and GND on Festiva.
(2)Resistance may vary by plus or minus 15 percent

VANE AIR TEMPERATURE RESISTANCE (1)