Notes on application of sealant to coolant pump housing - AH20.10-P-0001-02RVK
Engine 113.990/991/992/993/995
Application of sealant to timing case cover
The sealing surface must be cleaned. The sealant must only be applied on the timing case cover to the specified surfaces in the form of a sealing compound bead 2.0 mm(± 0.5 mm) diameter. The sealing compound must be applied within 10 min. The sealing compound bead must not be spread. Only the sealing compound listed in the Repair Products may be used