TROUBLE SHOOTING
Note. See TROUBLE SHOOTING article in GENERAL INFORMATION.
TROUBLE SHOOTING PRECAUTIONS
Observe the following precautions when trouble shooting or testing charging system
- Obtain code number and deactivate audio anti-theft system before disconnecting battery (if equipped).
- DO NOT reverse battery cable connections. Rectifier will be damaged.
- Battery voltage should always exist at generator terminal "B".
- DO NOT ground generator terminal "L" while engine is running.
- DO NOT start engine with generator disconnected.
ON-VEHICLE TESTING
Note. Check generator wiring harness connections and drive belt tension. Fully charge battery before testing. Wait at least 30 seconds after starting engine before measuring system voltage.