- Disconnect the crankcase ventilation tube from the PCV valve.
- Rotate the PCV valve counterclockwise and remove from the valve cover. NOTE: A new Positive Crankcase Ventilation (PCV) valve must be installed if removed from the valve cover. Damage will occur to the locking mechanism on the PCV valve. NOTE: To install, apply clean engine oil to the O-ring seal. Discard the PCV valve.
- To install, reverse the removal procedure. Install a new PCV valve.
- If equipped, disconnect the PCV valve electrical connector.
- Disconnect the crankcase ventilation tube-to-PCV valve quick connect coupling. For additional information, refer to «QUICK CONNECT COUPLING»(ref-356642-S34050375382010022500000) .
- Rotate the PCV valve counterclockwise and remove from the crankcase vent oil separator. NOTE: A new Positive Crankcase Ventilation (PCV) valve must be installed if removed from the valve cover. Damage will occur to the locking mechanism on the PCV valve. NOTE: To install, apply clean engine oil to the O-ring seal. Discard the PCV valve.
- To install, reverse the removal procedure. NOTE: Upon installation, make sure the PCV valve electrical connector is pointing in the correct position to allow the wiring harness to be connected. Incorrect installation would require removal and installation of a new valve. Install a new PCV valve.
- Disconnect the PCV heater element electrical connector.
- Disconnect the crankcase ventilation tube-to-PCV heater element quick connect coupling. For additional information, refer to «QUICK CONNECT COUPLING»(ref-356642-S34050375382010022500000) .
- Remove the 2 PCV heater element bolts. To install, tighten to 6 N.m (53 lb-in).
- Remove the PCV heater element from the intake manifold.
- To install, reverse the removal procedure. NOTE: To install, apply clean engine oil to the O-ring seal. NOTE: When installing, make sure the PCV valve heater element electrical connector is in the correct position to allow the wiring harness to be connected.
- If equipped, disconnect the PCV valve electrical connector.
- Release the wire harness pin-type retainer from the crankcase vent oil separator.
- Disconnect the crankcase ventilation tube-to-PCV valve quick connect coupling. For additional information, refer to «QUICK CONNECT COUPLING»(ref-356642-S34050375382010022500000) .
- Remove the 3 crankcase vent oil separator bolts. To install, tighten to 8 N.m (71 lb-in).
- Remove the crankcase vent oil separator from the RH valve cover.
- To install, reverse the removal procedure.