Seat Calibration
The DSM is calibrated using a scan tool. The calibration procedure automatically powers the driver power seat through its full range of motion and records the full stop positions by monitoring the motor position sensors. Once the full stop positions or range of the seat have been recorded, the DSM will only operate within the calibrated range. Any input attempting to drive the seat beyond the calibrated range will be ignored. This calibration is used for all seat control functions including manual switch control and memory recall positioning. During the seat calibration, the DSM may identify a function that is inoperative, such as a position sensor not changing. If the DSM identifies a concern that has a related diagnostic trouble code (DTC), the DSM will set the related DTC at the end of the validation procedure.
The calibration procedure powers the seat track adjustments to the end of their travel, which is determined by the DSM sensing a change of state in the motor position sensors. If there is a concern with the seat track or motor position sensor that limits the travel, the DSM will interpret the stopping point as the end of travel and store the position. The DSM is not able to determine if the seat has moved to its full travel position. It is only capable of monitoring and storing the amount of travel seen by the position sensor changing states.
For additional information on carrying out the power seat calibration procedure, refer to the scan tool operating manual.